Rev.11.06.08_102
NLP65 Series
3 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
1 Naturalconvectioncooling.ModelsNLP65-X629J,NLP65-X608J,NLP65-
X610Jmustnotexceed62.5Wattscontinuousoutputpowerwithnatural
convection.ModelNLP65-X620Jnottoexceed65Wattscontinuousoutput
powerwithnaturalconvection.ModelNLP65-3322Jmustnotexceed60Watts
continuousoutputpowerwithnaturalconvection.
2 Whentheinputvoltageislessthan90Vactheoperatingtemperaturerangeis
0°Cto+40°C.Therippleandregulationspecicationsmaynotbemet.
3 Peakoutputcurrentlastinglessthan60secondswithdutycyclelessthan5%.
Duringpeakloading,outputvoltagemayexceedtotalregulationlimits.
4 Figureispeak-to-peakforconvectionpowerrating.Outputnoise
measurementsaremadeacrossa20MHzbandwidthusinga6inchtwisted
pair,terminatedwitha10µFelectrolyticcapacitoranda0.1µFceramic
capacitor.
5 Threeorthogonalaxes,randomvibration10minutesforeachaxes,2.4Grms5
Hzto500Hz.
6 Aminimumloadonthemainoutputisrequiredforproperstartup.For
multipleoutputsandsingle+5Voutput,theminimumloadonthe+5Vis
0.2A.Forsingleoutputsgreaterthan+5Vtheminimumloadis0.1A.To
maintainstatedregulationthen:
for single output units
I≥0.2A
for multiple output units
0.25 ≤ I(A)/I(B) ≤5,forI(A)≥0.2A.
7 Foroptimumreliability,nopartoftheheatsinkshouldexceed120oC, and no
semiconductorcasetemperatureshouldexceed130oC.
8 CAUTION:Allowaminimumof1secondafterdisconnectinglinepowerwhen
makingthermalmeasurements.
9 Thisproductisonlyforinclusionbyprofessionalinstallerswithinother
equipmentandmustnotbeoperatedasastandaloneproduct.
10 Maximumcontinuousoutputpowerforallmultipleoutputmodelsmustnot
exceed75Watts(70wattsforNLP65-3322J)with20CFMforcedaircooling.
11 ConductedemissionstestingwereperformedusingthestandardEN55022set-
upwithastandaloneNLP65unitplacedonagroundedmetalplatewithaline
chokeontheACinputandgroundwires(i.e.thewiresareloopedthroughan
EMIsuppressiontoroid).
Forsystemcomplianceitisusuallynecessarytoinstallan‘off-the-shelf’AC
inletwithanintegrallinelterinthesystemchassisortoinstallalinechoke
ontheinputwiresascloseaspossibletoACentrypointofthesystemchasssis.
PleasecontacttheapplicationsgroupforassistancewithEMIcompliance.
12 TheNLP65unitswiththesufx‘G’isthegroundpinandgroundchokeoption.
J2,L6andJP10areincluded.J2isasafetyagencyapprovedgroundingpin,L6
isagroundchokeandJP10isajumper.Thisoptionisintendedforuseinnon-
metallicchassisapplicationswheregroundingisnotpossibleviathemounting
screws.ThegroundchokeisprovidedtoassistsystemEMCcompliance.When
performingconductedemissionstestingonstandaloneunits,the‘G’option
isrequiredtomeetlevelB.Toordersimplyaddthesufx‘G’tothestandard
modelnumber,e.g.NLP65-7608GJ,NLP65-9608GJ.Thisoptionisavailablefor
boththePFCandnon-PFCversions.
13 Allmodelsrequireaminimummountingstand-offof0.25inches(6.35mm)in
theenduseproduct.
14 TheNLP65-9608Jisavailablewithanenclosure.Toorderanenclosedversion,
seemodelnumberingoptionsbelow.
15 NoPFCversion,EN61000-3-2isnotapplicabletothismodel.
16 The‘J’sufxindicatesthatthesepartsarePb-free(RoHS6/6)compliant.
17 NOTICE:Somemodelsdonotsupportalloptions.Pleasecontactyourlocal
EmersonNetworkPowerrepresentativeorusetheon-linemodelnumber
searchtoolathttp://www.powerconversion.com.
ModelNumberingOptions
1 Theenclosureversionincludes:IECconnector,on/offswitch,wireharness
outputconnectorandttedcover.Toorder,pleaseaddthesufx‘E’themodel
number,e.g.NLP65-9608EJ.SeeNLP65enclosurefordetails.
2 ASafetyearthgroundpinandgroundchokeareavailableasanoption.
Toorder,pleaseaddthesufx‘G’themodelnumber,e.g.NLP65-X608GJ.
3 Toorderanenclosurekit(untted),orderthepartnumberLPX80.
Output
Voltage
OutputCurrent
Ripple(4)
Total
Regulation(6)
Non-harmonic
Corrected
Harmonic
Corrected
Ground
Pin(12,14,17)
Max(1) Peak(3) Fan(10)
+5V(IA) 7.5A 9.1A 8A 50mV ±2.0% NLP65-7608J NLP65-9608J NLP65-X608GJ
+12V(IB) 2.5A 3.3A 3A 150mV ±5.0%
–12V 0.65A 0.81A 0.8A 120mV ±5.0%
+5V(IA) 7.5A 9.1A 8A 50mV ±2.0% NLP65-7610J NLP65-9610J NLP65-X610GJ
+15V(IB) 2.2A 2.9A 2.5A 150mV ±5.0%
–15V 0.65A 0.85A 0.8A 150mV ±5.0%
+5V 7.0A 9.1A 8.0A 50mV ±2.0% NLP65-3322J(15)
+24V 1.5A 2.6A 2.0A 240mV ±5.0%
+12V 0.7A 1.0A 1.0A 120mV ±5.0%
+5V(IA) 7A 9.1A 8A 50mV ±2.0% NLP65-7620J NLP65-9620J NLP65-X620GJ
+24V(IB) 2A 2.6A 2A 240mV ±5.0%
+5V(IA) 7A 9.1A 8A 50mV ±2.0% NLP65-7629J NLP65-9629J NLP65-X629GJ
+12V(IB) 2.5A 3.3A 3A 150mV ±5.0%
+5V 10A 13A 12A 50mV ±2.0% NLP65-7605J NLP65-9605J NLP65-X605GJ
+12V 5.4A 7A 6.5A 120mV ±2.0% NLP65-7612J NLP65-9612J NLP65-X612GJ
+15V 4.4A 5.7A 5.3A 150mV ±2.0% NLP65-7615J NLP65-9615J NLP65-X615GJ
+24V 2.7A 3.5A 3.5A 240mV ±2.0% NLP65-7624J NLP65-9624J NLP65-X624GJ
Notes