SINGLE PHASE 35 AMP BRIDGE RECTIFIERS
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Tc=55 C
Dimensions in inches and (millimeters)
FEATURES
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 17.5AD.C.
Maximum DC Reverse Current Ta=25 C
at Rated DC Blocking Voltage Ta=100 C
MB3505W MB351W MB352W MB354W MB356W MB358W MB3510W UNITS
50 100 200 400 600 800 1000 V
50 100 200 400 600 800 1000 V
35 70 140 280 420 560 700
35
400
10
500
-65 +150
-65 +125
V
A
A
V
* 400 amperes surge capability
* Superior thermal design
* Mounting: Hole thru for #8 screw
MB3505W THRU MB3510W
1.1
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
MB-35W
.468(11.9)
.429(10.9)
.591
(15.0)
.732(18.6)
.692(17.6)
.732(18.6)
.692(17.6)
1.181(30.0)
1.102(28.0)
1.181(30.0)
1.102(28.0)
HOLE FOR
NO. 8 SCREW
.452
(11.5)
.673(17.1)
.633(16.1)
MAX.
MIN.
+
AC
AC
.042(1.1)
.039(1.0)DIA.
TYP.
35.0 Amperes
Storage Temperature Range, TSTG
Operating Temperature Range, TJ
C
C
A
A
0.1
1.0
.01
0
10
50
RATING AND CHARACTERISTIC CURVES (MB3505W THRU MB3510W)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
FIG.1-TYPICAL FORWARD CURRENT
AVERAGE FORWARD CURRENT,(A)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT,(A)
0
10
20
30
40
50
60
0
200
100
300
500
400
20 40 60 80 100 120 140
3.0
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
DERATING CURVE
0.1
1.0
.01
10
50
FIG.3-TYPICAL FORWARD
CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT,(A)
FORWARD VOLTAGE,(V)
Pulse Width 300us
1% Duty Cycle
0 .2 .4 .6 .8 1.0 1.2 1.4
3.0
0 25 50 75 100 125 150 175
Tj=25 C
Tj=25 C
NUMBER OF CYCLES AT 60Hz
1 10 5 50 100
Tj=25 C 8.3ms Single Half
Sine Wave
JEDEC method
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
CASE TEMPERATURE,( C)
REVERSE LEAKAGE CURRENT, ( A)