3.3 - 87
3.3
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Negative Regulators In Hermetic
JEDEC TO-3 Package
4 11 R0
HERMETIC TO-3 FIXED VOLTAGE NEGATIVE
REGULATORS APPROVED TO DESC DRAWINGS
FEATURES
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally to ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Similar To Industry Standards 7905, 7912, 7915
Hi-Rel Screening Available
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed TO-3
metal package . All protective features are designed into the circuit, including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, -15V. These
units are ideally suited for Military applications where a hermetically sealed package
is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8874601 YX OM1905NKM
5962-8874701 YX OM1912NKM
5962-8874801 YX OM1915NKM
OM1915NKMOM1905NKM
OM1912NKM
3.3 - 88
OM1905NKM - OM1915NKM
3.3
ELECTRICAL CHARACTERISTICS -5 Volt VIN = -10V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage VOUT TA= 25°C -4.95 -5.05 V
VIN = -7.5V to -20V -4.85 -5.15 V
IO = 5mA to 1.0 A, P< 20W
Line Regulation VRLINE VIN = -7.5V to -20V 12 mV
(Note 1) 25 mV
(Note 4) VIN = -8.0V to -12V 5 mV
12 mV
Load Regulation VRLOAD IO = 5mA to 1.5 Amp 20 mV
(Note 1) 25 mV
IO = 250mA to 750 mA 15 mV
30 mV
Standby Current Drain ISCD 2.5 mA
3.0 mA
Standby Current Drain DISCD VIN = -7.0V to -20V 0.4 mA
Change With Line (Line)
Standby Current Drain DISCD IO= 5mA to 1000mA 0.4 mA
Change With Load (Load)
Dropout Voltage VDO DVOUT = 100mV, IO=1.0A 2.5 V
Peak Output Current IO (pk) TA= 25°C 1.5 3.3 A
Short Circuit Current IDS VIN = -35V 1.2 A
(Note 2) 2.8 A
Ripple Rejection DVIN f =120 Hz, DVIN = -10V 63 dB
DVOUT (Note 3) 60 dB
Output Noise Voltage NOTA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability DVOUT TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) Dt
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6W
Thermal Resistance qJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
aa qJA .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W
3.3 - 89
OM1905NKM - OM1915NKM
3.3
ELECTRICAL CHARACTERISTICS -12 Volt VIN = -19V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage VOUT TA= 25°C -11.88 -12.12 V
VIN = -14.5V to -27V -11.64 -12.36 V
IO = 5mA to 1.0 A, PD< 20W
Line Regulation VRLINE VIN = -14.5V to -27V 20 mV
(Note 1) 50 mV
(Note 4) VIN = -16V to -22V 10 mV
30 mV
Load Regulation VRLOAD IO = 5mA to 1.5 Amp 32 mV
(Note 1) 60 mV
IO = 250mA to 750 mA 16 mV
30 mV
Standby Current Drain ISCD 3.5 mA
4.0 mA
Standby Current Drain DISCD VIN = -14.5V to -27V 0.8 mA
Change With Line (Line)
Standby Current Drain DISCD IO= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage VDO DVOUT = 100mV, IO=1.0A 1.8 V
Peak Output Current IO (pk) TA= 25°C, IO= 5mA to 1A 1.5 3.3 A
Short Circuit Current IDS VIN = -35V 1.2 A
(Note 2) 2.8 A
Ripple Rejection DVIN f =120 Hz, DVIN = -10V 56 dB
DVOUT (Note 3) 53 dB
Output Noise Voltage NOTA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability DVOUT TA= 25°C, t = 1000 hrs. 120 mV
(Note 3) Dt
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
1.197
1.177
0.675
0.655
0.188 R.
MAX.
0.440
0.420
0.161
0.151 0.525 R.
MAX.
0.225
0.205
SEATING
PLANE
0.312
MIN.
0.450
0.250
0.043
0.038
2 PLCS.
0.135
MAX.
0.875
MAX.
1.53
REF.
Pin Connection
Pin 1: Ground
Pin 2: Output
Case: Input
2
1
OM1905NKM - OM1915NKM
3.3
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246
205 Crawford Street, Leominster, MA 01 453 USA (508) 534-5776 FAX (508) 537-4246
ELECTRICAL CHARACTERISTICS -15 Volt VIN = -23V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage VOUT TA= 25°C -14.85 -15.15 V
VIN = -17.5V to -30V -14.55 -15.45 V
IO = 5 mA to 1.0 A, PD < 20 W
Line Regulation VRLINE VIN = -17.5V to -30V 25 mV
(Note 1) 50 mV
(Note 4) VIN = -20V to -26V 15 mV
25 mV
Load Regulation VRLOAD IO = 5mA to 1.5 Amp 35 mV
(Note 1) 75 mV
IO = 250mA to 750 mA 21 mV
45 mV
Standby Current Drain ISCD 6.0 mA
6.5 mA
Standby Current Drain DISCD VIN = -17.5V to -30V 0.8 mA
Change With Line (Line)
Standby Current Drain DISCD IO= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage VDO DVOUT = 100mV, IO=1.0A 2.5 V
Peak Output Current IO (pk) TA= 25°C 1.5 3.3 A
Short Circuit Current IDS VIN = -35V 1.2 A
(Note 2) 2.8 A
Ripple Rejection DVIN f =120 Hz, DVIN = -10V 53 dB
DVOUT (Note 3) 50 dB
Output Noise Voltage N OTA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability DVOUT TA= 25°C, t = 1000 hrs. 150 mV
(Note 3) Dt
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5
3
2.5
2
1.5
1
0.5
00 5 10 15 20 25 30 35
PEAK OUTPUT CURRENT
DVOUT = 100mV
Tj=
Tj= 25°C
Tj= 150°C
Input To Output Differential (V)
2.5
2
1.5
1
0.5
0-75-50 -25 0 25 50 75 100 125 150
DROPOUT VOLTAGE
DVOUT = 100MV
IOUT = 0A
IOUT = 500mA
IOUT = 1A
Junction Temperature (°C)
100
80
60
40
20
010 100 1k 10k 100k
RIPPLE REJECTION
VOUT = 5V
VIN - V = 8VDC +3.5Vrms
IOUT = 1A
Tj= 25°C
Frequency (Hz)
TYPICAL PERFORMANCE CHARACTERISTICS
Output Current (A)
Output Current (A)
Ripple Rejection (dB)