E
13
SPECIFICATION
TS-1500-112TS-1500-124TS-1500-148TS-1500-212TS-1500-224TS-1500-248
75A
21 ~ 30VDC
89%
37.5A
42 ~ 60VDC
89%
75A
21 ~ 30VDC
90%
37.5A
42 ~ 60VDC
91%
MODEL
AC VOLTAGE
MAXIMUM OUTPUT POWER (Typ.)
WAVEFORM Note.2
OUTPUT FREQUENCY
AC REGULATION (Typ.)
EFFICIENCY (Typ.) Note.2
DC CURRENT (Typ.) Note.5
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER TEMPERATURE
OUTPUT SHORT
REVERSE POLARITY
GFCI PROCTECTION
PROTECTION
PROTECTION
True sine wave (THD<3%)
150A
10.5 ~ 15VDC
88%
40A*5 30A*3 30A*2
30A*230A*3
±3.0%
10.5 ~ 15VDC
87%
150A
40A*5
82 5℃±
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recover
82 5℃± 96 5℃±
None
68 5℃± 68 5℃± 68 5℃±
By internal fuse open
U 458 (L only for "GFCI" receptacle-Type F ) None
Compliance to FCC class A
None
WORKING TEMP. Note.1
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
0 ~ +40 @ 100% load ; 60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RHo
U 458 (L only for "GFCI" receptacle-Type F )
Compliance to EN61000-4-2,3,8
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
True sine wave output (THD<3%)
High surge power up to 3000W
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software
3 years warranty
RATED POWER (Typ.) 1500W
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 125% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Features :
OTHERS
PACKING 6.81Kg; 2pcs/14.6Kg/1.61CUFT
DIMENSION 420*220*88mm (L*W*H)
NOTE 1.Output derating capacity referenced by curve 1.
2.THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Input derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
6.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V
→± →± →±
200 / 220 / 230 / 240VAC selectable by setting button
100 / 110 / 115 / 120VAC selectable by setting button
1725W for 180 sec. / 1875W for 10 sec. / surge power 3000W for 30 cycles
11.3 4%±22.5 4%±45 4%±45 4%±22.5 4%±
10.5 4%±21 4%±42 4%±42 4%±21 4%±
11.3 4%±
10.5 4%±
1500W True Sine Wave DC-AC Power Inverter TS-1500 series
File Name:TS-1500-SPEC 2015-05-27
50 0.1Hz 50/60Hz selectable by setting button S.W±
60 0.1Hz 50/60Hz selectable by setting button S.W±
FRONT PANEL INDICATOR
SAVING MODE (Typ.) Default disabled. Load 5W will be changed to standby mode
Battery voltage level, output load level, saving mode, fault and operation status
24V 48V 24V 48V
BAT. VOLTAGE 12V12V
NO LOAD DISSIPATION 18W @ standby saving mode
OFF MODE CURRENT DRAW 1mA
BATTERY TYPES Open & sealed Lead Acid
CONTROL WIRING RJ11 -RS232 (Option)
LVD None EN60950-1
EMC IMMUNITY
EMC EMISSION
VOLTAGE RANGE (Typ.)
Note.3,6
E
13
CURVE 1
CURVE 2
AMBIENT TEMPERATURE ( )
010203040506070
20
40
60
80
100
BATTERY INPUT VOLTAGE (V)
10.5VDC
21VDC
42VDC
11.5VDC
23VDC
46VDC
15VDC
30VDC
60VDC
20
40
60
80
100
(HORIZONTAL)
LOAD (%)
LOAD (%)
File Name:TS-1500-SPEC 2015-05-27
TS-1500 series
A :TYPE A OUTLET
B :TYPE B OUTLET
C :TYPE C OUTLET
D :TYPE D OUTLET
E :TYPE E OUTLET
F :TYPE F OUTLET
TS:True sine wave inverter 12:12VDC
24:24VDCBat. Voltage:
48:48VDC
1:110VAC
2:230VAC
Output:
O/P Wattage:1500W
TS 1500 112 A
207
Type-A
Type-B
220
203.2 108.4
712.1
48
10
Air flow
direction
420
Remote
port
15.6
11.05
27.45
36.25
57.75
WARNING:
Inverter
Inverter Inverter
Inverter
Reverse Polarity
Will Damage The
ENG POS
DC
INPUT
Chassis
Ground
Cat.No.(1GG1HS-212)
Wire Range(10-4AWG Str
Cu Soldered Wires)
Torque (17.7-26.5 in lb)
1500W True Sine Wave DC-AC Power Inverter
TYPE-A
Receptacle type
Country
Certificate
TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F
USA EUROPE AUSTRALIA U.K JAPAN GFCI
(Expect for 48V input)
AC Output Receptacles (optional)
EE
13 13
Mechanical Specification Derating Curve
Unit:mm
BATTERY
100
0
100
0
Saving
Bat Low
On
Setting
LOAD
INVERTER
Remote
port
AC OUTPUT
ON
OFF
AC OUTPUT
BATTERY
100
0
100
0
Saving
Bat Low
On
Setting
LOAD
INVERTER
ON
OFF
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
TS-1500-148F TS-1500-124F TS-1500-112F TS-1500-112A TS-1500-124A TS-1500-148A TS-1500-212B TS-
1500-224B TS-1500-248B