Rev. 3.8.10_#43
LPQ200-M Series
1 of 3
Embedded Power for
Business-Critical Continuity
LPQ200-M Series
200 Watts
Special Features
Medical and ITE safeties
Active power factor correction
3” x 5” footprint
Less than 1U high
EN61000-3-2 compliant
Remote sense
Power fail
Adjustable outputs
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Thermal overload protection
LPX200 enclosure kit available
Total Power: 100 - 200 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Quad
Electrical Specifications
Safety
Input
Input ra nge: 90 - 264 Vac; 120 - 300 Vdc
Frequency: 47 - 63 Hz
Inrush current: 50 A max., cold start @ 25 °C, 230 Vac input
Efficiency: 84% typical at full load
EMI/RFI: FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current:
275 uA @ 50/60 Hz, 264 Vac input
Output
Maximum power: 100 W for convection ; 200 W with 30CFM forced air
Adjustment range: All outputs -20%, +10%, except for the 3V3 output which will be -15%, +10%
(LPQ201-M)
Hold-up time: 16 ms @ 200 W load, 120 Vac input
Overload protection: Short circuit protection on all outputs. V1, V2 & V3 overload protected @
110 - 160%. V4 is 150 - 250% above rating
Overvoltage protection: 30 - 50% above nominal output on V1 (and V2 on LPQ202)
Logical Control
Power failure: Active low logic signal goes high 100-500 msec after main output; it goes
low at least 6 msec before loss of regulation
Remote sense: Compensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
TUV 60950, 60601-1
UL 60950, 60601-1
CSA 60950, 60601-1
CB Certificate & report
CE Mark (LVD)
Embedded Power for
Business-Critical Continuity
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air
Peak
Load Regulation2Ripple
P/P (PARD)3
LPQ201-M
+3V3 0 A 13 A 18 A 20 A ± 2% 50 mV
+5 V 0 A 13 A 18 A 20 A ± 5% 50 mV
+12 V 0 A 5 A 9 A 10 A ± 5% 120 mV
-12 V 0 A 1 A 2 A 2.5 A ± 5% 120 mV
LPQ202-M
+5 V 0 A 13 A 18 A 20 A ± 2% 50 mV
+12 V 0 A 5 A 9 A 10 A ± 5% 120 mV
+24 V 0 A 1.5 A 3 A 3.5 A ± 7% 240 mV
-12 V 0 A 1 A 2 A 2.5 A ± 5% 120 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3 . Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Rev. 3.8.10_#43
LPQ200-M Series
2 of 3
Operating temperature: 0° to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C. -20 °C
start up
Storage temperature: -40 °C to +85 °C
Electromagnetic
susceptibility:
Designed to meet EN61000-4;
-2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10 - 95%
Vibration: IEC68-2-6 to the levels of IEC721-3-2
MTBF calculated: 516,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore
Environmental Specifications
Pin Assignments
Connector LPQ200-M
SK1 Pin 1 Neutral
Pin 3 Line
SK2 Pin 1 V1 OUT
Pin 2 V2 OUT
Pin 3 GND OUT
Pin 4 GND OUT
Pin 5 GND OUT
Pin 6 GND OUT
Pin 7 V3 OUT
Pin 8 V4 OUT
SK3 Pin 1 +V1 Remote sense
Pin 2 -V1 Remote sense
Pin 3 N/C
Pin 4 N/C
Pin 5 +Power fail
Pin 6 Common
Pin 7 N/C
Pin 8 Common
Pin 9 +V2 Remote Sense (LPQ201-M only)
Pin 10 -V2 Remote Sense (LPQ201-M only)
Mating Connectors
AC Input (SK1): Molex 09-50-8031 (connector)
PINS: 08-52-0113
AC Ground: Molex 01-90020001
DC Output (SK2): Terminal block
Wire size based on Cable Ampacity/AWG
Control Signals
(SK3):
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Emerson Network Power Connector Kit #70-841-027, includes all of the above.
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± 0.02” (± 0.5 mm)
3. Mounting holes MH1 and MH2 should be grounded for EMI purposes.
4. Mounting hole MH1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC input, 25
°C unless otherwise stated.
6. This power supply requires mounting on metal
standoffs 0.20” (5 m) in height.
7. Warranty: 2 years
8. Weight: 1.5 lbs/0.68 kg
Rev. 3.8.10_#43
LPQ200-M Series
3 of 3
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
100W
Output Voltage
Adjust POT
2.55 (64.8)
3.00 (76.2)
0.224 (5.7) (4X)
0.224 (5.7) (4X)
5.00 (127)
4.55 (115.6)
PIN - 5
PIN - 10
PIN - 1
PIN - 8
SK3
SK2
Ø4 (4X)
Mounting Hole
Output Voltage
Adjust POT
PIN - 1
Ground Tab
PIN - 3
SK1
0.06 (1.5) (2X)
0.472 (12) 1.32 (33.6) max
0.098 (2.5)
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2010 Emerson Electric Co.
EmersonNetworkPower.com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power