Embedded Power for Business-Critical Continuity Rev. 3.8.10_#43 LPQ200-M Series 1 of 3 LPQ200-M Series 200 Watts Total Power: Input Voltage: # of Outputs: 100 - 200 Watts 90 - 264 Vac Quad Special Features * * * * * * * * * * * * * Medical and ITE safeties Active power factor correction 3" x 5" footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail Adjustable outputs Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection LPX200 enclosure kit available Electrical Specifications Input Input range: Frequency: Inrush current: Efficiency: EMI/RFI: Safety ground leakage current: Output Maximum power: 100 W for convection ; 200 W with 30CFM forced air All outputs -20%, +10%, except for the 3V3 output which will be -15%, +10% Adjustment range: (LPQ201-M) Hold-up time: 16 ms @ 200 W load, 120 Vac input Short circuit protection on all outputs. V1, V2 & V3 overload protected @ Overload protection: 110 - 160%. V4 is 150 - 250% above rating Overvoltage protection: 30 - 50% above nominal output on V1 (and V2 on LPQ202) Logical Control Power failure: Remote sense: Safety * * * * * TUV UL CSA CB CE 60950, 60601-1 60950, 60601-1 60950, 60601-1 Certificate & report Mark (LVD) 90 - 264 Vac; 120 - 300 Vdc 47 - 63 Hz 50 A max., cold start @ 25 C, 230 Vac input 84% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 275 uA @ 50/60 Hz, 264 Vac input Active low logic signal goes high 100-500 msec after main output; it goes low at least 6 msec before loss of regulation Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 3.8.10_#43 LPQ200-M Series 2 of 3 Environmental Specifications Operating temperature: Storage temperature: Electromagnetic susceptibility: Humidity: Vibration: MTBF calculated: 0 to 50 C ambient derate each output as 2.5% per degree from 50 to 70 C. -20 C start up -40 C to +85 C Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10 - 95% IEC68-2-6 to the levels of IEC721-3-2 516,000 hours at full load and 25 C ambient conditions. 230 Vac input, Bellcore Ordering Information Model Number LPQ201-M LPQ202-M Output Minimum Maximum Load with Maximum Load with Voltage Load Convection Cooling 30CFM Forced Air Peak Load Regulation2 Ripple P/P (PARD)3 50 mV +3V3 0A 13 A 18 A 20 A 2% +5 V 0A 13 A 18 A 20 A 5% 50 mV +12 V 0A 5A 9A 10 A 5% 120 mV -12 V 0A 1A 2A 2.5 A 5% 120 mV +5 V 0A 13 A 18 A 20 A 2% 50 mV +12 V 0A 5A 9A 10 A 5% 120 mV +24 V 0A 1.5 A 3A 3.5 A 7% 240 mV -12 V 0A 1A 2A 2.5 A 5% 120 mV 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 mHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. Pin Assignments Connector LPQ200-M SK1 Pin 1 Neutral Pin 3 Line SK2 Pin 1 V1 OUT Pin 2 V2 OUT Pin 3 GND OUT Pin 4 GND OUT Pin 5 GND OUT Pin 6 GND OUT Pin 7 V3 OUT Pin 8 V4 OUT SK3 Pin 1 +V1 Remote sense Pin 2 -V1 Remote sense Pin 3 N/C Pin 4 N/C Pin 5 +Power fail Pin 6 Common Pin 7 N/C Pin 8 Common Pin 9 +V2 Remote Sense (LPQ201-M only) Pin 10 -V2 Remote Sense (LPQ201-M only) MatingConnectors AC Input (SK1): Molex 09-50-8031 (connector) PINS: 08-52-0113 AC Ground: Molex 01-90020001 DC Output (SK2): Terminal block Wire size based on Cable Ampacity/AWG Control Signals (SK3): Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 Emerson Network Power Connector Kit #70-841-027, includes all of the above. 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is 0.02"( 0.5 mm) 3. Mounting holes MH1 and MH2 should be grounded for EMI purposes. 4. Mounting hole MH1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25 C unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20" (5 m) in height. 7. Warranty: 2 years 8. Weight: 1.5 lbs/0.68 kg Embedded Power for Business-Critical Continuity Americas Mechanical Drawing 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Output Voltage Adjust POT PIN - 8 SK2 PIN - 1 PIN - 5 SK3 PIN - 10 0.224 (5.7) (4X) Output Voltage Adjust POT 2.55 (64.8) O4 (4X) Mounting Hole 3.00 (76.2) 0.224 (5.7) (4X) Rev. 3.8.10_#43 LPQ200-M Series 3 of 3 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 4.55 (115.6) For global contact, visit: www.Emerson.com/EmbeddedPower 100W techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. PIN - 1 SK1 PIN - 3 Ground Tab 5.00 (127) Asia (HK) 0.06 (1.5) (2X) 0.472 (12) 0.098 (2.5) 1.32 (33.6) max Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2010 Emerson Electric Co.