0713 BU-SB13738 Page 1 of 4 Data Sheet # 1030
NON/NOS, 600/250Vac Class K5 & H
NON (250V) 18-600A, General Purpose Fuses
Description: Basic protection 250V NON Class K5 and H
general purpose, non-current-limiting, one-time fuses.
Catalog Symbol: NON-(amp)
Ratings:
Volts — 250Vac
— 125Vdc (18-100A)
Amps 18-600A
IR — 50kA Vac RMS Sym. (18-60A)
— 10kA Vac RMS Sym. (65-600A)
— 50kA Vdc (18-60A)
— 10kA Vdc (65-100A)
Agency Information:
CE, UL Listed, Class K5 (18-60A), Std. 248-9,
Class H (65-600A), Std. 248-6 (125Vdc 18-100A),
UL Guide JDDZ, File E4274
CSA Certified, Class 1421-01, File 53787 (18-12A, 65-600A)
For CSA Certified 15-60A, see PON Data Sheet # 4126.
Catalog Numbers (amps)
NON-18NON-3 NON-12 NON-65 NON-200
NON-12NON-3210 NON-15 NON-70 NON-225
NON-34NON-4 NON-20 NON-75 NON-250
NON-810 NON-5 NON-25 NON-80 NON-300
NON-1 NON-6 NON-30 NON-90 NON-350
NON-114NON-614NON-35 NON-100 NON-400
NON-112NON-7 NON-40 NON-110 NON-450
NON-1610 NON-8 NON-45 NON-125 NON-500
NON-2 NON-9 NON-50 NON-150 NON-600
NON-212NON-10 NON-60 NON-175
Carton Quantity and Weight
Amp Rating Carton Qty.
18-30 10
35–60 10
65–100 5
110–200 1
225–400 1
450–600 1
Dimensions – in
Features:
Protect lighting, heating and other circuits not subject to temporary
surges and where available short-circuit currents are relatively low
NON one-time fuses do not have any appreciable degree of time-
delay and thus should not be specified in circuits where large
transients or motor overloads occur. Use Bussmann advanced
protection FUSETRON™ FRN-R or ultimate protection Low-Peak™
LPN-RK dual-element, time-delay fuses.
For general purpose circuits, size at amp rating of circuit
For motor circuits, size at 300% to 400% according to the NEC®
motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
Recommended Fuse Blocks
Fuse Amps 1-Pole 2-Pole 3-Pole
0-30 H25030-1 H25030-2 H25030-3
35-60 H25060-1 H25060-2 H25060-3
70-100 HM25100-1CR HM25100-2CR HM25100-3CR
110-200 HM25200-1CR HM25200-2CR HM25200-3CR
225-400 HM25400-1CR HM25400-2CR HM25400-3CR
450-600 HM25600-1CR HM25600-2CR HM25600-3CR
For additional information on 250 volt fuse blocks, see Data
Sheet # 1112 (H250) and product brochure # 3192 (HM Se-
ries).
Fuse Reducers For Class R Fuses
Equipment Desired Fuse Catalog Numbers
Fuse Clips (Case) Size (Pairs) 250V
60A 30A NO.263
100A 30A NO.213
60A NO.216
200A 60A NO.226
200A 100A NO.2621
400A 100A NO.2641
200A NO.2642
For additional information on Class K5 & H fuse reducers, see
Data Sheet # 1118.
0.56" (± 0.008)
2"
(0.031)
0.81" (± 0.008)
3"
(0.031)
1.06"
5.88" (± 0.062)
1/8 to 30A
35 to 60A
70 to 100A
All Diameters ± 0.008
2.06"
2.59"
8.63" (± 0.094)
10.38" ( 0.094)
225 to 400A
450 to 600A
1.56"
7.13" (± 0.062)
110 to 200A
0713 BU-SB13738 Page 2 of 4 Data Sheet # 1030
NON/NOS, 600/250Vac Class K5 & H
Time-Current Curves - Average Melt
20
100
1,000
10,000
300
100
10
1
0.1
0.01
CURRENT IN AMPS
TIME IN SECONDS
60A
100A
200A
30A
400A
AMP RATING
600A
15A
35A
20A
NON (250V) 18-600A, General Purpose Fuses
0713 BU-SB13738 Page 3 of 4 Data Sheet # 1030
NON/NOS, 600/250Vac Class K5 & H
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information
contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
NOS (600V), 1-600A, General Purpose Fuses
Description: Basic protection 600V NOS Class K5 and H
general purpose, non-current-limiting, one-time fuses.
Catalog Symbol: NOS-(amp)
Ratings:
Volts — 600Vac
Amps — 1-600A
IR — 50kA Vac RMS Sym. (1-60A)
— 10kA Vac RMS Sym. (70-600A)
Agency Information:
CE, UL Listed, Class K5 (1-60A), Std. 248-9,
Class H (70-600A), Std. 248-6, UL Guide JDDZ, File E4273
CSA Certified, Class 1421-01, File 53787
Catalog Numbers (amps)
NOS-1 NOS-9 NOS-40 NOS-100 NON-300
NOS-2 NOS-10 NOS-45 NOS-110 NOS-350
NOS-3 NOS-12 NOS-50 NOS-125 NOS-400
NOS-4 NOS-15 NOS-60 NOS-150 NOS-450
NOS-5 NOS-20 NOS-70 NOS-175 NOS-500
NOS-6 NOS-25 NOS-75 NOS-200 NOS-600
NOS-7 NOS-30 NOS-80 NOS-225
NOS-8 NOS-35 NOS-90 NOS-250
NOS 600V Carton Quantity and Weight
Amp Rating Carton Qty.
1–30 10
35–60 10
70–100 5
110–200 1
225–400 1
450–600 1
Dimensions – in
Features:
Protect lighting, heating and other circuits not subject to temporary
surges and where available short-circuit currents are relatively low
NOS one-time fuses do not have any appreciable degree of time-
delay and thus should not be specified in circuits where large
transients or motor overloads occur. Use Bussmann advanced
protection FUSETRON™ LPS-R or ultimate protection Low-Peak™
LPS-RK dual-element, time-delay fuses.
For general purpose circuits, size at amp rating of circuit
For motor circuits, size at 300% to 400% according to the NEC®
motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
Recommended Fuse Blocks
Fuse Amps 1-Pole 2-Pole 3-Pole
0-30 H60030-1 H60030-2 H60030-3
35-60 H60060-1 H60060-2 H60060-3
70-100 HM60100-1CR HM60100-2CR HM60100-3CR
110-200 HM60200-1CR HM60200-2CR HM60200-3CR
225-400 HM60400-1CR HM60400-2CR HM60400-3CR
450-600 HM60600-1CR HM60600-2CR HM60600-3CR
For additional information on 600 volt fuse blocks, see Data
Sheet # 1112 (H) and product brochure # 3192 (HM Series).
Fuse Reducers For Class R Fuses
Equipment Desired Fuse Catalog Numbers
Fuse Clips (Case) Size (Pairs) 250V
60A 30A NO.663
100A 30A NO.216
60A NO.616
200A 60A NO.626
200A 100A NO.2621
400A 100A NO.2641
200A NO.2642
For additional information on Class R fuse reducers, see
Data Sheet # 1118.
0.81" (± 0.008)
5" (± 0.031)
1.06" (± 0.008)
5.5" (± 0.031)
1 to 30A
35 to 60A
1.34"
7.9" (± 0.062)
70 to 100A
3.13"
13.38" ( 0.094)
450 to 600A
2.59"
11.63" (± 0.094)
225 to 400A
1.84"
9.63" (± 0.062)
110 to 200A
All Diameters ± 0.008
0713 BU-SB13738 Page 4 of 4 Data Sheet # 1030
NON/NOS Class K5 & H, 600/250Vac
NOS (600V), 1-600A, General Purpose Fuses
Time-Current Curves - Average Melt
20
100
1,000
10,000
300
100
10
1
0.1
0.08
0.06
0.04
0.03
0.02
0.01
CURRENT IN AMPS
TIME IN SECONDS
60A
100A
200A
30A
400A
AMP RATING
600A
15A
35A
20A
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information
contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.