ULTRA-LOW VOLTAGE OPERATION CHARGE PUMP IC FOR STEP-UP DC-DC CONVERTER STARTUP
Rev.1.0_00 S-882Z Series
Seiko Instruments Inc. 5
Electrical Characteristics
Table 4
(Ta = 25°C unless otherwise specified)
Parameter Symbol Conditions Min. Typ. Max. Unit
Measurement
Circuit
Discharge start
voltage*1 VCPOUT1 VIN = 0.35 V VCPOUT1(S)
− 0.1 VCPOUT1(S)
VCPOUT1(S)
+ 0.1 V 1
VCPOUT2 VCPOUT1(S) = 1.8 V VCPOUT1
− 0.60 − VCPOUT1
− 0.33 V 1
Discharge stop
voltage*2
VCPOUT1(S) = 2.0 V VCPOUT1
− 0.67 − VCPOUT1
− 0.33 V 1
VCPOUT1(S) = 2.2 V VCPOUT1
− 0.74 − VCPOUT1
− 0.33 V 1
VCPOUT1(S) = 2.4 V VCPOUT1
− 0.80 − VCPOUT1
− 0.33 V 1
VIN VCPOUT1(S) = 1.8 to 2.4 V,
Ta = −40 to +85°C 0.35 − 3.0 V 2
Operating input
voltage*3
VCPOUT1(S) = 1.8, 2.0 V,
Ta = −30 to +60°C 0.30 − 3.0 V 2
Oscillation start
voltage VST Not externally connected, voltage
applied to VIN − − 0.3 V −
Discharge
control switch
resistance
RM1 VCPOUT = 1.8 to 2.4 V,
IOUT = 3 mA − 34 100 Ω 3
Discharge start
delay time*4 tOUT VIN = 0.35 V, CCPOUT = 10 µF − 7 25 s 2
Discharge start
voltage
temperature
coefficient
CPOUT1
CPOUT1
VTa
V
•∆
∆Ta = −40 to +85°C − ±150 ±550 ppm/°C −
ISS VIN = 0.3 V, VCPOUT = 0 V − 0.1 0.5 mA 4
VIN = 0.6 V, VCPOUT = 0 V − 0.5 1.5 mA 4
Current
consumption
during operation VIN = 1.0 V, VCPOUT = 0 V − 1.2 3.0 mA 4
ISSS VIN = 0.3 V, VCPOUT = 0 V, VVM = 3.0 V − − 0.6 µA 5
VIN = 0.6 V, VCPOUT = 0 V, VVM = 3.0 V − − 0.7 µA 5
VIN = 1.0 V, VCPOUT = 0 V, VVM = 3.0 V − − 0.7 µA 5
Current
consumption
during shutdown
VIN = 2.0 V, VCPOUT = 0 V, VVM = 3.0 V − − 0.8 µA 5
Shutdown
voltage*5 VOFF VIN = 0.3 V, VCPOUT = 0 V VOFF(S)
− 0.1 VOFF(S)
VOFF(S)
+ 0.1 V 6
Shutdown
voltage
temperature
coefficient
OFF
OFF
VTa
V
•∆
∆ Ta = −40 to +85°C − ±150 ±550 ppm/°C −
Discharge
control switch
leak current*6
ILEAK VIN = VCPOUT = 0 V,
VOUT = VVM = 3.0 V − − 0.1 µA 7
VM pin input
current IVM VVM = 3.0 V − 1.0 1.9 µA 8
Oscillation
frequency fOSC VIN = 0.3 V − 350 − kHz −
*1. V
CPOUT1 : Actual discharge start voltage value, VCPOUT1(S) : Discharge start voltage setting value
*2. Voltage at which discharge to the OUT pin stops
*3. Input voltage required to start discharge to the OUT pin from the startup capacitor
*4. Delay time from when power is input to the VIN pin until the electric charge of the startup capacitor is discharged to the
OUT pin
*5. V
OFF : Actual shutdown voltage value (VM pin voltage value at which shutdown actually occurs)
V
OFF(S) : Shutdown voltage setting value (VM pin voltage setting value at which shutdown occurs)
V
OFF(S) is automatically set to VCPOUT1(S) + 0.1 V.
*6. Current that flows into the IC from the OUT pin due to the off-leak current of the discharge control switch
Caution The voltage that is input to the connected step-up DC-DC converter varies according to the consumption
current of the step-up DC-DC converter and the power smoothing capacitor. Set the discharge start
voltage based on thorough evaluation including the temperature characteristics under the actual usage
conditions.