120W Reliable Green Medical Power Supply + EN 60601-1 IEC 60601-1 8 ANSI/AAMI ES60601-1 EN60601-1 RPS-120 series + IEC60601-1 Features 4"x2" compact size Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/EN60601-1 Suitable for BF application with appropriate system consideration 84W convention, 120W force air EMI Class B for both Class(with FG) & Class (no FG) configuration No load power consumption<0.3W Extremely low leakage current 12V/0.5A fan supply Protections: Short circuit / Overload / Over voltage / Over temperature Operating altitude up to 4000 meters 3 years warranty Applications Oral irrigator Hemodialysis machine Medical monitors Sleep apnea devices Pumps machine Description RPS-120 is a 120W highly reliable green PCB type medical power supply with a high power density on a 4 by 2 footprint. It accepts 80~264VAC input and offers various models with the output voltages between 12V and 48V. The working efficiency is up to 91% and the extremely low no load power consumption is down below 0.3W. RPS-120 is able to be used for both Class(with FG) or Class(no FG) system design. The extremely low leakage current is less than 150A. In addition, it conforms to the international medical regulations (2*MOPP) and EMC EN55011, perfectly fitting all kinds of BF rated patient contact medical system equipment. Model Encoding RPS - 120 - 12 -C { Blank : PCB type -C : Enclosed type Output voltage Rated wattage Series name File Name:RPS-120-SPEC 2020-10-20 RPS-120 120W Reliable Green Medical Power Supply series SPECIFICATION MODEL DC VOLTAGE CURRENT RATED POWER 10CFM RPS-120-12 RPS-120-15 RPS-120-24 12V 15V 24V 27V 48V 10A 8A 5A 4.5A 2.5A 5.6A 3.5A 3.15A 1.75A 120W 120W 121.5W 120W 84W 84W 85W 84W 120mVp-p 150mVp-p 150mVp-p 150mVp-p Convection 7.0A 10CFM 120W Convection 84W RIPPLE & NOISE (max.) Note.2 100mVp-p OUTPUT 14.3~15.8V 22.8~25.2V 25.6 ~ 28.4V 45.6 ~50.4V 2.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC 90% 91% LINE REGULATION FREQUENCY RANGE 113 ~ 370VDC 47 ~ 63Hz EFFICIENCY (Typ.) 89% AC CURRENT (Typ.) 2.1A/115VAC INRUSH CURRENT (Typ.) COLD START 30A/115VAC LEAKAGE CURRENT(max.) Note.5 OVERLOAD PROTECTION 500ms, 30ms/115VAC at full load 10ms/115VAC at full load VOLTAGE RANGE Note.4 80 ~ 264VAC INPUT RPS-120-48 VOLTAGE TOLERANCE Note.3 2.0% VOLTAGE ADJ. RANGE 11.4~12.6V RPS-120-27 89% OVER TEMPERATURE FUNCTION FAN SUPPLY 60A/230VAC Earth leakage current < 150A/264VAC , Touch current < 80A/264VAC 115~150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 16.5 ~ 19.5V 13.2 ~ 15.6V OVER VOLTAGE 90% 1.2A/230VAC 26.4 ~ 31.2V 29.7 ~ 35V 52.8 ~ 62.4V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover 12V@0.5A for driving a fan ; tolerance -15% ~ +10% WORKING TEMP. -30 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.6 4000 meters SAFETY STANDARDS IEC60601-1, TUV EN60601-1, EAC TP TC 004 , UL ANSI / AAMI ES60601-1 (3.1 version), CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved; Design refer to EN60335 - 1 ISOLATION RESISTANCE Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP WITHSTAND VOLTAGE I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMISSION SAFETY & EMC (Note 7) EMC IMMUNITY OTHERS NOTE Parameter Standard Test Level / Note Conducted emission EN55011 (CISPR11) Class B Radiated emission EN55011 (CISPR11) Class B Harmonic current Voltage flicker EN60601-1-2 EN61000-3-2 Class A EN61000-3-3 ----- Parameter Standard Test Level / Note ESD EN61000-4-2 Level 4, 15KV air ; Level 4, 8KV contact RF field susceptibility EN61000-4-3 Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) EFT bursts Surge susceptibility Conducted susceptibility EN61000-4-4 Level 3, 2KV EN61000-4-5 Level 4, 4KV/Line-FG; 2KV/Line-Line EN61000-4-6 Level 3, 10V Magnetic field immunity EN61000-4-8 Voltage dip, interruption EN61000-4-11 Level 4, 30A/m 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods MIL-HDBK-217F (25) MTBF 653.5Khrs min. DIMENSION (L*W*H) PCB:101.6*50.8*29mm or 4" * 2" *1.141" inch ; Enclosed type:103.4*62*40mm or 4.07" * 2.44" *1.57" inch PACKING PCB:0.15Kg; 72pcs/11.8Kg/0.84CUFT ; Enclosed type:0.24Kg; 60pcs/15.4Kg/1.06CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1f & 47f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. Touch current was measured from primary input to DC output. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:RPS-120-SPEC 2020-10-20 RPS-120 120W Reliable Green Medical Power Supply series Block Diagram fosc : 65KHz EMI FILTER & RECTIFIER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER RECTIFIERS & FILTER FG +V -V +12V FAN SUPPLY DETECTION CIRCUIT O.T.P. O.L.P. CONTROL O.V.P. Derating Curve 100 With 10CFM Fan for RPS-120(-C) 80 70 Convection for RPS-120(-C) 24~48V LOAD (%) 60 40 Convection for RPS-120(-C) 12~15V 20 -30 0 10 20 30 40 45 50 70 (HORIZONTAL) 60 AMBIENT TEMPERATURE () Output Derating VS Input Voltage 100 90 80 LOAD (%) 70 60 50 40 80 90 115 120 130 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPS-120-SPEC 2020-10-20 RPS-120 120W Reliable Green Medical Power Supply series Mechanical Specification RPS-120 (PCB Type) Top View 50 . 8 FAN 5cm 3.175 Note 10CFM Air flow direction 1 2 CN101 HS1 44.45 3 2 1 SVR1 LED 1 2 3 4 HS2 FS1 T4A/250V CN2 FS2 T4A/250V 4 - 3.175 95.25 3.3 29 101.6 3 max. 50.8 CN1 Side View File Name:RPS-120-SPEC 2020-10-20 RPS-120 120W Reliable Green Medical Power Supply series Mechanical Specification Case No.245A RPS-120-C (Enclosed Type) Unit:mm Side View Top View Side View Side View 103.4 78 12.7 100 1.7 2-R1.75 20 25 40 2-M3 L=4 Side View 5 1. 7 FAN 10CFM 5cm Air flow direction CN101 CN1 12 1 2 3 4 62 3 2 1 CN2 30.8 2-M3 L=2 24.2 55 Bottom View File Name:RPS-120-SPEC 2020-10-20 120W Reliable Green Medical Power Supply RPS-120 series AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B4P-VH or equivalent Pin No. 1,2 3,4 Assignment +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent FAN Connector(CN101) : JST S2B-PH-K-S or equivalent Pin No. Assignment DC COM(FAN-) 1 2 +12V(FAN+) Mating Housing Terminal JST PHR-2 or equivalent JST SPH-002T-P0.5S or equivalent 1.HS1,HS2 cannot be shorted. 2.HS1 must have safety isolation distance with system case. Note : 1. The FAN supply is designed to serve as the source of the additive external fan for the cooling of the power supply, enabling the full load delivery and assuring the best life span of the product. Please do not use this FAN supply to drive other devices. 2.The PCB type(Blank type)model delivers EMI Class B for both conducted emission and radiated emission for the power supply, when configured into either Class (with FG) or Class (no FG) system. 3.The Enclosed type(-C type) model is not suitable for the configuration within a Class (no FG) system but is suggested to used within a Class (with FG) system. Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:RPS-120-SPEC 2020-10-20