3
Insulation Characteristics
Parameter Symbol Min. Max. Units
Apparent charge at Sample Test stage and Type Test stage
after subgroup 1 (method a) [1]
qpd 5 pC
Apparent charge at Routine Test stage and Type Test stage,
Preconditioning (method b) [2]
qpd 5 pC
Maximum Transient Voltage, peak [3] VIOTM_1inch
VIOTM_2inch
VIOTM_3inch
VIOTM_4inch
15
27
40
50
kV
Maximum Transient Voltage, eective [3] VISO_1inch
VISO_2inch
VISO_3inch
VISO_4inch
10.5
19
28.1
35.2
kV
Maximum Working Voltage, peak [4] VIORM_1inch
VIORM_2inch
VIORM_3inch
VIORM_4inch
4.25
8.5
12.75
17.00
kV
Maximum Working Voltage, eective [4] VIOWM_1inch
VIOWM_2inch
VIOWM_3inch
VIOWM_4inch
3
6
9
12
kV
Insulation Resistance @ Tamb,max , min.100°C RIO 1011 Ω
Insulation Resistance @ TSRIO 109Ω
Creepage Distance 1inch
2inch
3inch
4inch
25
50.4
75.8
101.2
mm
Clearance Distance 1inch
2inch
3inch
4inch
25
50.4
75.8
101.2
mm
Surge Isolation Voltage VIOSM 12 kV
Comparative Tracking Index CTI 600
Pollution degree [5] 2
Climatic category [6] 40/085/21
Maximum ambient Safety temperature TS110 °C
Maximum input current ISI 60 mA
Maximum output current ISO 30 mA
Maximum input power dissipation PSI 330 mW
Maximum output power dissipation PSO 165 mW
Notes:
1. Vpd(m) = 1.6 x VIORM (=6.8kV for 1inch, =13.6kV for 2inch, =20.4kV for 3inch, =27.2kV for 4inch), Vini,a = VIOTM, tini,a = 60s ; tm = 10s
2. Vpd(m) = 1.875 x VIORM (=8kV for 1inch, =16kV for 2inch, =24kV for 3inch, =32kV for 4inch), Vini,b = VIOTM, tini,b = 1s ; tm = 1s
3. Altitude up to 2000m above sea level
4. Pollution degree 2; please note that inhomogeneous eld conditions may lead to partial discharge through air for these voltages
5. According IEC-60064-1
6. According IEC-60068-1