57
60 Series
General Purpose Relays 10 A
A range of general purpose relays with 2 CO (DPDT) or 3 CO (3PDT) contacts
• PCB mount version available
• AC or DC coils
• Approvals (according to type): BEAB, CSA, DEMKO, GOST, IMQ, RINA, SEV, cUL, VDE
WOOD-PROCESSING
MACHINES INDUSTRIAL
APPLIANCES
AUTOMATIC
GATES MEDICAL
EQUIPMENT PLASTIC
MOULDING ON-BOARD SHIP
APPLIANCES
ELEVATORS TOOLING
MACHINES CERAMIC INDUSTRY
MACHINES
60 Series
General Purpose Relays 10 A
58
60.43
P.C.B. RELAYS 10 A
TYPE 60.42 2 CO (DPDT)
TYPE 60.43 3 CO (3PDT)
- Tin plated copper pins (1.2 x 0.5 mm)
- Standard contact material: AgNi
- Options: see coding table page 62
- Ordering information: see page 62
BEAB
RINA
C
GOST
32.2
18
7.1 7.1
32.2
9
7.1 7.1
43
36
6
10.8 9 6
5.9 4.3
60.42 60.43
10 11
8 9
4
7
10 11
1 52 63
9
4
7
1 63
60.42 60.43
7.1
32.2
7.1
1 3
4 6
7 9
10 11
4.3
5.9
6
9
10.8
36 1.5
18
7.1 9 9
32.2
7.1
1 2 3
4 5 6
7 8 9
10 11
4.3
5.9
6
9
10.8
36 1.5
60.4360.42
copper side view
DIELECTRIC STRENGTH between coil and contacts 2,000 V
tested at leakage current between open contacts 2,000 V
10 mA for 1 min at 50 Hz between adjacent contacts 1,000 V
between frame and live parts
2,000 V
SURGE TEST (1.2/50 µs) 2,500 V
BETWEEN COIL AND CONTACTS
ISOLATION RESISTANCE 20 · 103M
ISOLATION GROUP C 250
MAXIMUM SWITCHING
FREQUENCY - without load 36,000 cycles/h
- at rated load 1,800 cycles/h
AMBIENT TEMPERATURE (–40 ... +70)°C
MECHANICAL LIFE
20 · 106cycles version AC
50 · 106cycles version DC
PROTECTION CATEGORY
IP 40
OF ENCLOSURES
OPERATE AND RELEASE TIME
- pick-up time (0 to UN)
15 ms (including contact bounce)
- drop-out time (UNto 0)
15 ms (including contact bounce)
TYPE OF DUTY continuous
DIELECTRIC TEST
TYPE OF RELAY all-or-nothing
2
TECHNICAL DATA
K 60
1
0.8
0.6
0.4
1 0.40.60.8 0.2
k
59
60 Series
General Purpose Relays 10 A
RATED CURRENT 10 A
MAXIMUM PEAK CURRENT 20 A
NOMINAL RATE IN AC1 2,500 VA
NOMINAL RATE IN AC15 500 VA
RATED VOLTAGE 250 V AC
MAXIMUM SWITCHING VOLTAGE 400 V AC
BREAKING CAPACITY IN DC1 see diagram H 60
SINGLE PHASE HP MOTOR RATING 0.37 kW/0.6 HP
CONTACT RESISTANCE: - initial 50 m
MINIMUM SWITCHING LOAD 500 mW (10 V/5 mA)
STANDARD CONTACT MATERIAL AgNi
F 60
0.5 2.5
3
10
7
10
106
10
5
1.5 2
H 60
20 60
100 140 180 220
20
10
6
4
2
1
0.6
0.4
0.2
0.1
B CA
COS ϕ
k REDUCTION FACTOR
LOAD (kVA)
CYCLES
VOLTAGE DC (V)
MAX SWITCHING CURRENT (A)
Load reduction factor vs cos ϕ.
Contact life vs AC1 load at 1800 cycles/h. Breaking capacity for DC1 load at 1800 cycles/h.
A= load applied to 1 contact
B= load applied to 2 contacts in series
C= load applied to 3 contacts in series
CONTACT SPECIFICATIONS
60 Series
General Purpose Relays 10 A
AC DC
RATED POWER 2.2 VA 1.3 W
OPERATING RANGE (0.8 to 1.1) UN(0.8 to 1.1) UN
HOLDING VOLTAGE 0.8 UN0.5 UN
MUST DROP-OUT VOLTAGE 0.2 UN0.1 UN
NOMINAL MAGNETOMOTIVE FORCE 180 A 250 A
THERMAL INSULATION CLASS OF WIRE F (+155°C) F (+155°C)
THERMAL RESISTANCE 43°C/W 43°C/W
CONDUCTED DISTURBANCE IMMUNITY BURST (acc. to EN 61000 - 4 - 4) level 4 (4 kV)
SURGE (acc. to EN 61000 - 4 - 5) level 4 (4 kV)
VERSIONS:
AC - alternating current 50/60 Hz
DC - direct current
AM - current sensing
DI - DC coil with a diode in parallel
60
COIL SPECIFICATIONS
Rated Resistance
Nominal coil
voltage absorption
UNUmin U max R
I
V V V mA
64.8 6.6 28 214
12 9.6 13.2 110 109
24 19.2 26.4 445 53.9
48 38.4 52.8 1,770 27.1
60 48 66 2,760 21.7
110 88 121 9,420 11.7
Rated Resistance
Nominal
coil
voltage
absorption
UNUmin U max R
UN50 Hz I
V V V mA
64.8 6.6 4.6 367
12 9.6 13.2 19 183
24 19.2 26.4 80 91.7
48 38.4 52.8 320 45.8
60 48 66 500 36.7
110 88 121 1,800 20
120 96 132 1,940 18.6
230 184 253 7,250 9.6
240 192 264 8,500 9.2
Operating range Operating range
AC VERSION DATA
R values relate to +20°C. Tolerance of R and I values: ± 10%. DC VERSION DATA
R values relate to +20°C. Tolerance of R and I values: ± 10%.
60 Series
General Purpose Relays 10 A
61
S 60/1
10 20 30 40 50 60
0
10
20
30
40
50
70
60
1.1 UN
UN
0.8 UN
S 60/3
10 20 30 40 50 60
0
10
20
30
40
50
70
60
1.1 UN
UN
0.8 UN
R 60
1
0.9
-20 0 20 40 60 80
Umin
UN
0.8
0.7
0.6
0.5
- 40
S 60/2
10 20 30 40 50 60
0
10
20
30
40
50
70
60
1.1 UN
UN
0.8 UN
HEATING TIME (min)
AMBIENT TEMPERATURE (°C)
TEMPERATURE RISE “t” (°C)
HEATING TIME (min)
TEMPERATURE RISE “t” (°C)
HEATING TIME (min)
TEMPERATURE RISE “t” (°C)
DC coil min pick-up voltage vs ambient temperature.
Umin = pick-up voltage
UN= rated voltage
Temperature rise "t " vs applied voltage. DC coils.
Temperature rise "t " vs applied voltage. AC 60 Hz coils.
Temperature rise "t " vs applied voltage. AC 50 Hz coils.
COIL SPECIFICATIONS
60 Series
General Purpose Relays 10 A
62
2 7
10 27
10 27
10 27
10
Coil version = 3Option = 0030 Option = 0060 - 0070 Option = 0080 - 0090
ORDERING INFORMATION
OPTIONS
Example: a 60 series P.C.B.relay, 3 CO (3PDT) with coil rated 12 V DC.
Coil version
3 = DC diode in parallel to
coil (positive to pin 2)
8 = AC (50/60 Hz)
9 = DC
Type
4 = P.C.B.
No. of poles
2 = 2 CO (DPDT)
3 = 3 CO (3PDT)
Coil voltage
006 = 6 V
012 = 12 V
024 = 24 V
048 = 48 V
060 = 60 V
110 = 110 V
120 = 120 V AC only
230 = 230 V AC only
240 = 240 V AC only
Contact material
and contact circuit
00 = Standard
20 = AgCdO
50 = AgNi + 5µm Au
Series
6 0 0 1 24 3 00
00
9
Options
00 = Standard