ISO 9001 ISO 14001 AS 9100 CERTIFIED
Mini-Circuits
®
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661
The Design Engineers Search Engine Provides ACTUAL Data Instantly at
®
Notes: 1. Performance and quality attributes and conditions not expressly stated in this specification sheet are intended to be excluded and do not form a part of this specification sheet. 2. Electrical specifications
and performance data contained herein are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. 3. The parts covered by this specification sheet are subject to
Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard
Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp.
For detailed performance specs
& shopping online see web site
minicircuits.com
IF/RF MICROWAVE COMPONENTS
7.62 6.86 5.84 0.25 1.07 0.51 2.54
1.27 1.02 2.79 7.62 8.89
50Ω 0.1 to 200 MHz
RF Transformer
Plug-In T-622-X65+
T-622-X65
CASE STYLE: X65
PRICE: $3.25 ea. QTY (1-9)
Outline Dimensions ( )
inch
mm
Maximum Ratings
Pin Connections
Operating Temperature -20°C to 85°C
Storage Temperature -55°C to 100°C
RF Power 0.25W
DC Current 30mA
Outline Drawing
Transformer Electrical Specications
REV. B
M98898
T-622-X65
IG/TD/CP
130513
Typical Performance Data
Cong. F
Ω
RATIO FREQUENCY
(MHz)
INSERTION LOSS*
3 dB
MHz
2 dB
MHz
1 dB
MHz
1:1:1 0.1-200 0.1-200 0.5-100 5-80
* Insertion Loss is referenced to mid-band loss, 0.4 dB typ.
PRIMARY DOT X1,Y2,Z3
PRIMARY X6,Y5,Z4
FREQUENCY
(MHz)
INSERTION
LOSS
(dB)
INPUT
R. LOSS
(dB)
Features
• single-ended to balanced with impedance ratio selection
• also available with at pack (W38)
& surface mount gull-wing (KK81) leads
Applications
• HF/VHF
• test equipment
0.10 1.19 7.87
0.50 0.70 17.40
1.10 0.64 20.99
2.10 0.50 24.10
5.00 0.42 26.99
80.00 0.69 14.78
93.05 0.76 13.92
100.00 0.78 13.50
193.00 0.16 8.19
200.00 1.62 8.08
T-622-X65
INSERTION LOSS
0.0
0.5
1.0
1.5
2.0
2.5
0.1 1 10 100 1000
FREQUENCY (MHz)
INSERTION LOSS (dB)
T-622-X65
INPUT RETURN LOSS
0
10
20
30
40
50
0.1 1 10 100 1000
FREQUENCY (MHz)
RETURN LOSS (dB)
Permanent damage may occur if any of these limits are exceeded.
+RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications