POWER
μMP Series GEN II
Up to 1800 Watts with New Product Enhancements
Total Power:
Up to 1800 Watts Peak*
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Up to 12
Special featureS
Full Medical EN60601 approval
PMBus monitor/control of input
functions
High efciency
Constant current limit protection
High power density.
- μMP04: 10.8 W/cu-in
- μMP09: 18.5 W/cu-in
- μMP10: 15.1 W/cu-in
- μMP16: 22.9 W/cu-in
Low noise intelligent fan (speed
control/fault status), 36% reduction
from GEN I
Downloadable GUI from website
Optional conformal coating
Industrial temp range (-40 ºC to 70 ºC)
No preload required
Military STD shock/vibration (40G’s)
Low cost
IEC, terminal block or barrier strip input
connection options
Low prole 1U size
Superior aesthetics over GEN I
certificatiONS
UL UL60950-1 / CSA 22.2
No.60950-1/
ES60601-1 / CSA 22.2
No.60601-1
TUV EN60950-1 / EN60601-1
CB Certicate and Report
CE Compliance to LVD and
RoHS Directives
CQC Approved
Medical 2x MOPP
** μMP tested according to the medical
standard IEC 60601-1-2 4th Edition.
Electrical Specications
Input
Input ra nge 85 - 264 Vac, 120 - 350 Vdc (limited to 300 Vdc in medical applications)
Frequency 47 - 440 Hz
Inrush current 40 A peak max. (soft start)
Efficiency Up to 91.5% @ full case load
Power factor 0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz)
Standby power uMP10/16 < 13 W
uMP04/09 < 6 W
Turn-on time AC on 2 sec for μMP16/10 and 1.5 sec for μMP04/09, inhibit/enable 250 ms typical
EMI: CISPR 22/EN55022 Level “B” (Both Conducted and Radiated)
Leakage current <200 uA using center-tapped xfmr measurement method.
(<400 uA @ 264 VAC input)
Holdover storage 16.7 ms minimum (independent of input Vac, 0 °C to 50 °C)
At 1200 W for μMP16
AC OK Signal goes low indicating loss of AC input.
Hold up = Full cycle ride thru (50 Hz); Open collector
Harmonic current emission Meets EN61000-3-2
Isolation Meets EN60950 and EN60601
Global inhibit/enable TTL, Logic “1” and Logic “0”; fan off when unit is inhibited
Input fuse (internal) μMP16/10: 16 A, 500 Vac, 400 Vdc, μMP04/09: 10 A / 250 V. (both lines fused)
Warranty 2 years
Output
Factory set point accuracy ± 1%
Margining / V-Program ± 3 - 7% nominal analog (single output module only). Contact factory for simple
V-program modification (i.e. 0-5 V input = 0-100% output voltage).
Overall regulation 0.4% or 30 mV which ever is greater
Ripple RMS: 0.1% or 10 mV, whichever is greater
Pk-Pk: 1.0% or 50 mV, whichever is greater. Bandwidth limited to 20 MHz
Dynamic response < ± 5% or 250 mV, with 50% step load
Recovery time To within 1% in < 300 μsec
Reverse voltage protection 100% of rated output current
* Max output power for μMP16: 1000 W 90 - 100 VAC; 1200 W 100 - 180 VAC; 1600 W 180 - 200 W; 1800 W 200 - 264 VAC.
Operational specs for EMI and Hold-up are valid to 1600 W max.
Data Sheet
µMP Series Data Sheet
Electrical Specications
Output
Thermal protection (OTP) All outputs disabled when internal temp exceeds safe operating range
Remote sense Up to 0.5 V total drop (not available on triple output module)
Single wire parallel Current share to within 5% of total rated current from 20% to 100% rated load
DC OK ± 5% of nominal Open collector
Minimum load Not required
Housekeeping standby 5 Vdc @ 2.0 A max whenever AC input is applied. 1.0 A (2.0 A for μMP04) max convection cooled (when output is inhibited off)
Module inhibit Logic - output on with low or open. Different logic options available
Output/Output isolation > 1 Megohm, 500 V
Vout Full load (A) OVP trip max (V) OCP trip typ (Iout%) SCP trip max (Iout%) Overshoot (max mV) Peak Deviation (max mV)
3 V 3 Module
0.9
40 2.00 V 130% 160% 150 ± 250
3.3
40 5.96 V 130% 160% 250 ± 250
3.6
40 6.31 V 130% 160% 250 ± 250
5 V Module
3.2
36 5.76 V 130% 160% 250 ± 250
5
36 9.0 V 130% 160% 250 ± 250
6
30 10.80 V 130% 160% 300 ± 300
12 V Module
6
25 10.80 V 130% 160% 300 ± 300
12
20 15.60 V 130% 160% 600 ± 600
15
16 19.50 V 130% 160% 750 ± 750
24 V Module
12
13 15.60 V 130% 160% 600 ± 600
24
10 31.20 V 130% 160% 120 ± 1200
30
8 39.00 V 130% 160% 1500 ± 1500
48 V Module
28
7 36.40 V 130% 200% 1400 ± 1400
48
5 62.40 V 130% 160% 2400 ± 2400
60
4 78.00 V 130% 200% 3000 ± 3000
Environmental Specications
Operating temperature
-40 °C to 70 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C. Cold start soak -20 °C, allow 10 min
warm-up before all outputs are within specification.
Reverse air to 40
°C
Max due to fan derating.
Storage temperature
-40 °C to +85 °C
Electromagnetic susceptibility
Designed to meet EN61000-4:-3,-5,-6,-11 Class 3 Performance Criteria A
Humidity
Operating; non-condensing 10% to 95% RH
Vibration
MIL-STD-810E
MTBF demonstrated
> 350,000 hours at full load, one μMP04 case + two modules, Telcordia SR-332 calculated MTBF
Altitude
Up to 10 K feet; derate linear to 50% from 10 K - 30 K feet
µMP Series Data Sheet
Output Module Line-Up S2*
Output Range (Vdc) Max Current (Amps) Max Power (Watts) Module Codes Standard Outputs
0.9 - 3.6
40 144 A, B, C, D - 2, 2.2, 3, 3.3
3.2 - 6.0
36 180 E, F, G, H - 5, 5, 2, 5.5, 6.0
6.0 -15.0
25 240 I, J, K, L, M, N - 8, 10, 11, 12, 14, 15
12.0 - 30.0
13 240 O, P, Q, R, S - 18, 20, 24, 28, 30
33.0 - 60.0
7 240 T, U, V, W, X, Y - 33, 36, 42, 48, 54, 60
3.3 - 30.0
4/4 96/96 Dual Output Module. Each output is rated to 96 W (192 Watts total). Wide range is adjustable.
Ordering Information
First digit
0-9 = Parallel Code
Second Digit
0 = No Options
1 = Reverse Air
2 = Not Used
3 = Global Enable
5 = Opt 1 + Opt 3
Case Option Codes
Factory assigned
for modified
standards
Module Codes:
S2 = 200 W Single O/P (1 Slot)
SK = 1000 W Single O/P (3 Slot)
I = 96 W Dual O/P ISO GND (1 Slot)
HUP = Hold-Up Module
(10ms for 500W /1 Slot)
Voltage Codes: See voltage code
table
Module/Voltage
1-Phase Input where X =
4 = 1.57” x 3.5” x 10.0”; 400W - 600W 4 Slots*
04 = 1.57” x 3.5” x 10.0”; 400W - 600W 4 Slots
09 = 1.57 x 3.5 x 10.0, 550W-1100W 4 Slots
1 = 1.57 x 5.0” x 10.0”, 1000W-1200W, 6 Slots*
10 = 1.57 x 5.0” x 10.0”, 1000W-1200W, 6 Slots
16 = 1.57” x 5.0” x 10.0”, 1200W-1800W**, 6 Slots
* Not Recommended for new designs
** See Input Derating table below for uMP16
Input Type where Y =
T = Terminal Block
C = IEC Connector C14
S = Barrier Strip
Case Size
Hardware Code
Software Code
µMPXY - SKW - S2E - S2Q - ILL - 00 - A - ###
Case Line-Up
Case Max Output Dimensions Connections Max Continous Current
85-180 VAC 180-263 VAC
μ
MP04 - 4 Slot
400 W 600 W 256.9 x 88.9 x 40.0
(10.11” x 3.5” x 1.57”)
IEC, Terminal-Block,
Barrier-Strip 9.91
μ
MP09 - 4 Slot
550 W 1100 W 256.9 x 88.9 x 40.0
(10.11” x 3.5” x 1.57”)
IEC, Terminal-Block,
Barrier-Strip 9.91
μ
MP10 - 6 Slot
1000 W 1200 W 256.9 x 127 x 40.0
(10.11” x 5.0” x 1.57”)
IEC, Terminal-Block,
Barrier-Strip 13.87
μ
MP16 - 6 Slot
1000 W 1800 W 256.9 x 127 x 40.0
(10.11” x 5.0” x 1.57”)
IEC, Terminal-Block,
Barrier-Strip 13.87
μMP16 INPUT POWER DERATING
Paramater 85 - 99 Vac 100 - 140 Vac 180 - 199 Vac 200 - 264 Vac
Designed For 1000 W 1200 W 1600 W 1800 W
QAV Evaluation 1000 W 1200 W 1600 W 1800 W
Safety Label and Evaluation 1000 W 1000 W 1600 W 1600 W
Internal Part Number Reference Table
Part # Where X = Description Module Code
73-951-0001X-G2
T, C, S μMP10 Cases μMP10
73-956-0001X-G2
T, C, S μMP16 Cases μMP16
73-963-XXXX
0012, 0024, 0048, 04XX uMP 1000W Module SKL - SKZ
73-963-00XX-G2
0012, 0024, 0048, 04XX uMP 1000W Module SKL - SKZ
DC OUTPUT MODULE RATING (SK*) 3-SLOTS
Output (Vdc) MAX Current (Amps) MAX Power (Watts) Modules Codes (*) Standard Outputs
6.0 – 15.0 84 1000 H, I, J, K, L, M, N – 6, 8, 10, 11, 12, 14, 15
12.0 – 30.0 42 1000 O, P, Q, R, S – 18, 20, 24, 28, 30
28.0 – 60.0 21 1000 T, U, V, W, X, Y – 33, 36, 42, 48, 54, 60
µMP Series Data Sheet
Standard Output Ratings
Module Output
Voltage Code
Single
Output One
Slot 240
Watts Max
Single
Output
Three Slots
1000 Watts
Max
Dual Output One Slot
96 Watts
Module
Identification S2 SK I
Code Volts
Output
Current
V1
Output
Current
V1
Output Current
V1 V2
A 2.0 40.0 - NA
B 2.2 40.0 - NA
C 3.0 40.0 - NA
D 3.3 40.0 - 4.0 4.0
E 5.0 36.0 - 4.0 4.0
F 5.2 34.0 - 4.0 4.0
G 5.5 32.0 - 4.0 4.0
H 6.0 30.0 84.0 4.0 4.0
I 8.0 25.0 84.0 4.0 4.0
J 10.0 24.0 84.0 4.0 4.0
K 11.0 22.0 84.0 4.0 4.0
L 12.0 20.0 84.0 4.0 4.0
M 14.0 17.0 71.4 4.0 4.0
N 15.0 16.0 66.7 4.0 4.0
O 18.0 13.0 42.0 4.0 4.0
P 20.0 12.0 42.0 4.0 4.0
Q 24.0 10.0 42.0 4.0 4.0
R 28.0 8.6 35.7 3.4 3.4
S 30.0 8.0 33.3 3.2 3.2
T 33.0 7 21.0 NA
U 36.0 6.7 21.0 NA
V 42.0 5.7 21.0 NA
W 48.0 5.0 21.0 NA
X 54.0 4.4 18.5 NA
Y 60.0 4.0 16.7 NA
Voltage Codes Derating Curves - μMP10
400
500
600
700
800
900
1000
1100
1200
0 10 20 30 40 5 0 60 70
Output Power
Temperature
Standard Fan (12 V/24 V/48 V)
85 VAC 100 VAC 110 VAC 200 VAC 264 VAC
400
500
600
700
800
900
1000
1100
1200
0 10 20 30 40 50 60 7 0
Output Power
Temperature
Reverse FAN (12 V/24 V/48V)
85 VAC 100 VAC 110 VAC 200 VAC 264 VAC
400
500
600
700
800
900
1000
1100
1200
0 10 20 30 40 5 0 60 70
Output Power
Temperature
Standard Fan (12 V/24 V/48 V)
85 VAC 100 VAC 110 VAC 200 VAC 264 VAC
400
500
600
700
800
900
1000
1100
1200
0 10 20 30 40 50 60 7 0
Output Power
Temperature
Reverse FAN (12 V/24 V/48V)
85 VAC 100 VAC 110 VAC 200 VAC 264 VAC
Parallel Codes
Code Slots in Parallel Code Slots in Parallel Code Slots in Parallel Code Slots in Parallel
1 1&2 6 1&2&3 A 1&2; 3&4 0 no module in parallel
2 2&3 7 1,2,3&4 B 1,2&3; 4&5 H 3,4&5
3 3&4 8 1,2,3,4&5 C 1,2,3&4; 5&6 J 3,4,5&6
4 4&5 9 1,2,3,4,5&6 D 1&2; 3&4; 5&6 K 4,5&6
5 5&6 E 1,2&3; 4,5&6
Notes:
Parallel between SK* (1000 W Modules) and S2* (240 W Modules) will use the codes as follows
Code 3 to parallel 2 SK* modules
Code 3 to parallel 1 SK* module and 1 S2* module
Code H to parallel 1 SK* module and 2 S2* modules
µMP Series Data Sheet
S2 Module
J1
J2
Mates with
Landwin 2050S1000 Housing
2053T011V Pin
or
JST PHDR-10VS Housing
JST SPHD-002T-P0.5 (28-24)
JST SPHD-001T-P0.5 (26-22)
Connector Kit Part No.:
70-841-023
Figure 1. AC Input
Figure 2. Connector J1 & J2
2
1
10
9
2
1
10
9
1.0±0.25
5.3±0.5
4.5±0.3
36.5±0.3
0.8 - 1.5
130.0±1.5
1.6±0.16
29.8±0.2
32.5±0.3
36.5±0.3
37.5±0.3
12.5 MAX
3.0 MAX
CAPS HEIGHT
V ADJ
V+
V-
IEC Connector
Terminal Block
PEN L
DC Output Control & Signals
(Single output)
Pin Function
1 No connection
2 No connection
3 Current share
4 Module inhibit return
5 Module ISO inhibit
6 SCOM
7 -RMT sense
8 Margin
9 Remote margin / V prog.
10 +RMT sense
PFC Input Connector
(control & signals)
Pin Function
1 Input AC OK - “emitter”
2 Input AC OK - “collector”
3 Global DC OK - “emitter”
4 Global DC OK - “collector”
5 Spare
6Global inhibit/optional enable logic “1”
7Global inhibit/optional enable logic “0”
8 Global inhibit/optional enable return
9 +5 VSB housekeeping
10 +5 VSB housekeeping return
I2C Bus Output Connector
Pin Function
1 5 Vcc bus
2 Serial data signal (SDA)
3 Secondary return (COM)
4 Serial clock signal (SCL)
5 Address bit 2 (A2)
6No connection
7Address bit 1 (A1)
8 No connection
9 Address bit 0 (A0)
10 No connection
AC Input
Pin Function
1 AC neutral
2 AC line (hot)
3 Chassis (earth) ground
240 W
Pin Connectors
Input
85 - 264 Vac 200 - 264 Vac
µMP10 = 6 available slots 1000 W max. 1200 W max.
µMP16 = 6 available slots 1200 W max. 1800 W max.
S
L
O
T
6
S
L
O
T
4
S
L
O
T
5
S
L
O
T
3
S
L
O
T
2
S
L
O
T
1
J2
J1
S
L
O
T
S
L
O
T
S
L
O
T
S
L
O
T
4321
J2
J1
Input
85 - 264 Vac 200 - 264 Vac
µMP04 = 4 available slots 400 W max. 600 W max.
µMP09 = 4 available slots 550 W max. 1100 W max.
μMP04/09 (AC input on opposite side) μMP10/16 (AC input on opposite side)
µMP Series Data Sheet
122.00 0.5
52.40 +0.30
-0.30
34.70±0.50
DC Output Control & Signals
(Dual output)
Pin Function
1 -RMT sense V2
2 +RMT sense V2
3 No connection
4 Module inhibit rtn
5 Module ISO inhibit
6 SCOM
7 -RMT sense V1
8 No connection
9 No connection
10 +RMT sense V1
Dual Module
SK Module
DC Output Control & Signals
(Single output)
Pin Function
1 No connection
2 No connection
3 Current share
4 Module inhibit return
5 Module ISO inhibit
6 SCOM
7 -RMT sense
8 Margin
9 Remote margin / V prog.
10 +RMT sense
1000 W
48 V Output:
12/24 Volt Output:
µMP Series Data Sheet
μMP04/09 (400/600; 550/1100 Watts Max)
Case Size: μMP04/09: 10.11” x 3.5” x 1.57” (256.9 mm x 88.9 mm x 40.0 mm)
Weight: μMP04/09Case:1.96lbs•SingleO/P:0.22lb.
•DualO/P:0.16lb.•Blank:0.06lb.
Notes:
1. Input: IEC 60320 C13 (for IEC connector)
Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4 - 0.5 Nm); Wire: 12 - 16 AWG; Wire Strip Length: 0.354” (9.0 mm)
2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts. Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and SPHD-
002T-PO.5 (JST) pins.
3. Output Module Connectors: All single O/P modules are M4 x 10 mm screws; tighten between 6.94 to 8.68 lb-in (8.0 to 10.0 kg-cm). Dual O/P module is PUSH IN conductor connector; Wire Strip Length:
0.315” (8.0 mm); Control signal connector: Refer to Item 2.
4. Chassis Material: Steel with chemical lm coating (conductive).
5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138” (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m)
6. All dimensions are in millimeters and inches, and are typical.
μMP Series
µMP Series Data Sheet
μMP10 (1000/1200 Watts Max)
μMP16 (1200/1800 Watts Max)
Case Size: μMP10/16: 10.11” x 5” x 1.57” (256.9 mm x 127 mm x 40.0 mm)
Weight: μMP10/16Case:2.78lbs•SingleO/P:0.22lb.
•DualO/P:0.16lb.•Blank:0.06lb.
Notes:
1. Input: IEC 60320 C13 (for IEC connector)
Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4 - 0.5 Nm); Wire: 12 - 16 AWG; Wire Strip Length: 0.354” (9.0 mm)
2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts.Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and SPHD-
002T-PO.5 (JST) pins.
3. Output Module Connectors: All single O/P modules are M4 x 10 mm screws; tighten between 6.94 to 8.68 lb-in (8.0 to 10.0 kg-cm). Dual O/P module is PUSH IN conductor connector; Wire Strip Length:
0.315” (8.0 mm); Control signal connector: Refer to Item 2.
4. Chassis Material: Steel with chemical lm coating (conductive).
5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138” (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m)
6. All dimensions are in millimeters and inches, and are typical.
µMP Series Data Sheet
μMP HUP Module
The μMP HUP module is intended for use on μMP09 with high efficiency module (SK*) configurations. In such case, only one HUP can be used per case.
Its application is limited with μMP09 and μMP04 configurations and may have multiple HUP’s inserted.
The HUP module shall provide additional 224μF bulk capacitance (typ.). Typical hold-up time increase with HUP module in μMP09 case and SK* module is
10ms at 500W load.
73-950-002
μMP09 Cong with HUP at Slot1
Actual μMP HUP Module and μMP09 Conguration
Typical HUP Response with μMP09-SKW Conguration
µMP Series Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333 www.artesyn.com
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. Specifications subject to change without
notice. © 2019 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions,
please visit www.artesyn.com/legal.
μMP Series-DS 22May2019
Typical HUP Response with μMP09-S2* Conguration