POWER MP Series GEN II Up to 1800 Watts with New Product Enhancements Data Sheet Total Power: Up to 1800 Watts Peak* Input Voltage:85 - 264 Vac 120 - 300 Vdc # of Outputs: Up to 12 Special features Full Medical EN60601 approval PMBus monitor/control of input functions High efficiency Constant current limit protection High power density. - MP04: 10.8 W/cu-in - MP09: 18.5 W/cu-in - MP10: 15.1 W/cu-in - MP16: 22.9 W/cu-in Low noise intelligent fan (speed control/fault status), 36% reduction from GEN I Downloadable GUI from website Optional conformal coating Industrial temp range (-40 C to 70 C) No preload required Military STD shock/vibration (40G's) Low cost IEC, terminal block or barrier strip input connection options Low profile 1U size Superior aesthetics over GEN I Electrical Specifications Input Input range 85 - 264 Vac, 120 - 350 Vdc (limited to 300 Vdc in medical applications) Frequency 47 - 440 Hz Inrush current 40 A peak max. (soft start) Efficiency Up to 91.5% @ full case load Power factor 0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz) Standby power uMP10/16 < 13 W uMP04/09 < 6 W Turn-on time AC on 2 sec for MP16/10 and 1.5 sec for MP04/09, inhibit/enable 250 ms typical EMI: CISPR 22/EN55022 Level "B" (Both Conducted and Radiated) Leakage current Harmonic current emission <200 uA using center-tapped xfmr measurement method. (<400 uA @ 264 VAC input) 16.7 ms minimum (independent of input Vac, 0 C to 50 C) At 1200 W for MP16 Signal goes low indicating loss of AC input. Hold up = Full cycle ride thru (50 Hz); Open collector Meets EN61000-3-2 Isolation Meets EN60950 and EN60601 Global inhibit/enable TTL, Logic "1" and Logic "0"; fan off when unit is inhibited CERTIFICATIONS Input fuse (internal) MP16/10: 16 A, 500 Vac, 400 Vdc, MP04/09: 10 A / 250 V. (both lines fused) UL UL60950-1 / CSA 22.2 No.60950-1/ ES60601-1 / CSA 22.2 No.60601-1 TUV EN60950-1 / EN60601-1 CB Certificate and Report CE Compliance to LVD and RoHS Directives CQCApproved Medical 2x MOPP Warranty 2 years ** MP tested according to the medical standard IEC 60601-1-2 4th Edition. Holdover storage AC OK Output Factory set point accuracy 1% Margining / V-Program 3 - 7% nominal analog (single output module only). Contact factory for simple V-program modification (i.e. 0-5 V input = 0-100% output voltage). Overall regulation 0.4% or 30 mV which ever is greater Ripple RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater. Bandwidth limited to 20 MHz Dynamic response < 5% or 250 mV, with 50% step load Recovery time To within 1% in < 300 sec Reverse voltage protection 100% of rated output current * Max output power for MP16: 1000 W 90 - 100 VAC; 1200 W 100 - 180 VAC; 1600 W 180 - 200 W; 1800 W 200 - 264 VAC. Operational specs for EMI and Hold-up are valid to 1600 W max. MP Series Data Sheet Electrical Specifications Output Thermal protection (OTP) All outputs disabled when internal temp exceeds safe operating range Remote sense Up to 0.5 V total drop (not available on triple output module) Single wire parallel Current share to within 5% of total rated current from 20% to 100% rated load DC OK 5% of nominal Open collector Minimum load Not required Housekeeping standby 5 Vdc @ 2.0 A max whenever AC input is applied. 1.0 A (2.0 A for MP04) max convection cooled (when output is inhibited off) Module inhibit Logic - output on with low or open. Different logic options available Output/Output isolation > 1 Megohm, 500 V Environmental Specifications Operating temperature -40 C to 70 C ambient. Derate each output 2.5% per degree from 50 C to 70 C. Cold start soak -20 C, allow 10 min warm-up before all outputs are within specification. Reverse air to 40 C Max due to fan derating. Storage temperature -40 C to +85 C Electromagnetic susceptibility Designed to meet EN61000-4:-3,-5,-6,-11 Class 3 Performance Criteria A Humidity Operating; non-condensing 10% to 95% RH Vibration MIL-STD-810E MTBF demonstrated > 350,000 hours at full load, one MP04 case + two modules, Telcordia SR-332 calculated MTBF Altitude Up to 10 K feet; derate linear to 50% from 10 K - 30 K feet Vout Full load (A) OVP trip max (V) OCP trip typ (Iout%) SCP trip max (Iout%) Overshoot (max mV) Peak Deviation (max mV) 3 V 3 Module 0.9 40 2.00 V 130% 160% 150 250 3.3 40 5.96 V 130% 160% 250 250 3.6 40 6.31 V 130% 160% 250 250 3.2 36 5.76 V 130% 160% 250 250 5 36 9.0 V 130% 160% 250 250 6 30 10.80 V 130% 160% 300 300 5 V Module 12 V Module 6 25 10.80 V 130% 160% 300 300 12 20 15.60 V 130% 160% 600 600 15 16 19.50 V 130% 160% 750 750 24 V Module 12 13 15.60 V 130% 160% 600 600 24 10 31.20 V 130% 160% 120 1200 30 8 39.00 V 130% 160% 1500 1500 48 V Module 28 7 36.40 V 130% 200% 1400 1400 48 5 62.40 V 130% 160% 2400 2400 60 4 78.00 V 130% 200% 3000 3000 MP Series Data Sheet Case Line-Up Max Output Case 85-180 VAC 180-263 VAC MP04 - 4 Slot 400 W 600 W MP09 - 4 Slot 550 W 1100 W MP10 - 6 Slot 1000 W 1200 W MP16 - 6 Slot 1000 W 1800 W Dimensions Connections 256.9 x 88.9 x 40.0 (10.11" x 3.5" x 1.57") 256.9 x 88.9 x 40.0 (10.11" x 3.5" x 1.57") 256.9 x 127 x 40.0 (10.11" x 5.0" x 1.57") 256.9 x 127 x 40.0 (10.11" x 5.0" x 1.57") IEC, Terminal-Block, Barrier-Strip IEC, Terminal-Block, Barrier-Strip IEC, Terminal-Block, Barrier-Strip IEC, Terminal-Block, Barrier-Strip Max Continous Current 9.91 9.91 13.87 13.87 Output Module Line-Up S2* Output Range (Vdc) Max Current (Amps) Max Power (Watts) Module Codes Standard Outputs 0.9 - 3.6 3.2 - 6.0 6.0 -15.0 12.0 - 30.0 33.0 - 60.0 3.3 - 30.0 40 36 25 13 7 4/4 144 180 240 240 240 96/96 A, B, C, D - 2, 2.2, 3, 3.3 E, F, G, H - 5, 5, 2, 5.5, 6.0 I, J, K, L, M, N - 8, 10, 11, 12, 14, 15 O, P, Q, R, S - 18, 20, 24, 28, 30 T, U, V, W, X, Y - 33, 36, 42, 48, 54, 60 Dual Output Module. Each output is rated to 96 W (192 Watts total). Wide range is adjustable. DC OUTPUT MODULE RATING (SK*) 3-SLOTS Output (Vdc) MAX Current (Amps) MAX Power (Watts) Modules Codes (*) Standard Outputs 6.0 - 15.0 84 1000 H, I, J, K, L, M, N - 6, 8, 10, 11, 12, 14, 15 12.0 - 30.0 42 1000 O, P, Q, R, S - 18, 20, 24, 28, 30 28.0 - 60.0 21 1000 T, U, V, W, X, Y - 33, 36, 42, 48, 54, 60 Internal Part Number Reference Table Part # Where X = Description Module Code 73-951-0001X-G2 73-956-0001X-G2 73-963-XXXX 73-963-00XX-G2 T, C, S T, C, S 0012, 0024, 0048, 04XX 0012, 0024, 0048, 04XX MP10 Cases MP16 Cases uMP 1000W Module uMP 1000W Module MP10 MP16 SKL - SKZ SKL - SKZ Ordering Information MPXY Case Size 1-Phase Input where X = 4 = 1.57" x 3.5" x 10.0"; 400W - 600W 4 Slots* 04 = 1.57" x 3.5" x 10.0"; 400W - 600W 4 Slots 09 = 1.57 x 3.5 x 10.0, 550W-1100W 4 Slots 1 = 1.57 x 5.0" x 10.0", 1000W-1200W, 6 Slots* 10 = 1.57 x 5.0" x 10.0", 1000W-1200W, 6 Slots 16 = 1.57" x 5.0" x 10.0", 1200W-1800W**, 6 Slots * Not Recommended for new designs ** See Input Derating table below for uMP16 - SKW -Module/Voltage S2E - S2Q - ILL- Module Codes: S2 = 200 W Single O/P (1 Slot) SK = 1000 W Single O/P (3 Slot) I = 96 W Dual O/P ISO GND (1 Slot) HUP = H old-Up Module (10ms for 500W /1 Slot) Voltage Codes: See voltage code table 00 Case Option Codes First digit 0-9 = Parallel Code - Software A Code - Hardware ### Code Factory assigned for modified standards Second Digit 0 = No Options 1 = Reverse Air 2 = Not Used 3 = Global Enable 5 = Opt 1 + Opt 3 Input Type where Y = T = Terminal Block C = IEC Connector C14 S = Barrier Strip MP16 INPUT POWER DERATING Paramater 85 - 99 Vac 100 - 140 Vac 180 - 199 Vac 200 - 264 Vac Designed For QAV Evaluation Safety Label and Evaluation 1000 W 1000 W 1000 W 1200 W 1200 W 1000 W 1600 W 1600 W 1600 W 1800 W 1800 W 1600 W MP Series Data Sheet Parallel Codes Code Slots in Parallel Code Slots in Parallel Code 1 1&2 6 1&2&3 A 2 2&3 7 1,2,3&4 B Slots in Parallel Code Slots in Parallel 1&2; 3&4 0 no module in parallel 1,2&3; 4&5 H 3,4&5 3 3&4 8 1,2,3,4&5 C 1,2,3&4; 5&6 J 3,4,5&6 4 4&5 9 1,2,3,4,5&6 D 1&2; 3&4; 5&6 K 4,5&6 5 5&6 E 1,2&3; 4,5&6 Notes: Parallel between SK* (1000 W Modules) and S2* (240 W Modules) will use the codes as follows Code 3 to parallel 2 SK* modules Code 3 to parallel 1 SK* module and 1 S2* module Code H to parallel 1 SK* module and 2 S2* modules Voltage Codes Derating Curves - MP10 Standard Output Ratings Module Output Voltage Code Single Single Output Output One Three Slots Slot 240 1000 Watts Watts Max Max Standard Fan (12 V/24 V/48 V) Dual Output One Slot 96 Watts 1200 2.2 40.0 - NA 3.0 40.0 - NA D 3.3 40.0 - 4.0 4.0 E 5.0 36.0 - 4.0 4.0 400 F 5.2 34.0 - 4.0 4.0 G 5.5 32.0 - 4.0 4.0 H 6.0 30.0 84.0 4.0 4.0 I 8.0 25.0 84.0 4.0 4.0 J 10.0 24.0 84.0 4.0 4.0 K 11.0 22.0 84.0 4.0 4.0 L 12.0 20.0 84.0 4.0 4.0 M 14.0 17.0 71.4 4.0 4.0 N 15.0 16.0 66.7 4.0 4.0 O 18.0 13.0 42.0 4.0 4.0 P 20.0 12.0 42.0 4.0 4.0 Q 24.0 10.0 42.0 4.0 4.0 R 28.0 8.6 35.7 3.4 3.4 S 30.0 8.0 33.3 3.2 T 33.0 7 21.0 NA U 36.0 6.7 21.0 NA V 42.0 5.7 21.0 NA W 48.0 5.0 21.0 NA X 54.0 4.4 18.5 NA Y 60.0 4.0 16.7 NA Code A Volts 2.0 S2 SK I Output Current V1 Output Current V1 Output Current 40.0 - V1 V2 NA 3.2 100 VAC 200 VAC Standard 110 FanVAC (12 V/24 V/48 V) 85 VAC 100 VAC 110 VAC 264 VAC 200 VAC 264 VAC 0 10 20 30 40 Temperature 50 60 70 0 10 20 30 40 Temperature 50 60 70 Reverse FAN (12 V/24 V/48V) 1200 Output Output Power Power Module Identification OutputOutput Power Power B C 1100 1200 1000 1100 900 1000 800 900 700 800 600 700 500 600 400 500 85 VAC 1100 1200 1000 1100 900 1000 800 900 700 800 600 700 500 600 400 500 0 85 VAC 100 VAC VAC 200 VAC Reverse FAN110 (12 V/24 V/48V) 264 VAC 85 VAC 100 VAC 264 VAC 200 VAC 10 20 30 40 Temperature 50 60 70 10 20 30 40 Temperature 50 60 70 400 0 110 VAC MP Series Data Sheet MP04/09 (AC input on opposite side) S L O T S L O T S L O T S L O T 4 3 2 1 MP10/16 (AC input on opposite side) S L O T 5 S L O T J2 J1 6 S L O T 4 S L O T 3 S L O T 1 S L O T 2 J2 J1 Input Input 85 - 264 Vac200 - 264 Vac MP04 = 4 available slots MP09 = 4 available slots 400 W max. 550 W max. MP10 = 6 available slots MP16 = 6 available slots 600 W max. 1100 W max. 85 - 264 Vac200 - 264 Vac 1000 W max. 1200 W max. 1200 W max. 1800 W max. Pin Connectors Figure 1. AC Input J2 I2C Bus Output Connector AC Input IEC Connector Terminal Block PEN L Pin 1 2 3 Function Mates with Landwin 2050S1000 Housing 2053T011V Pin AC neutral AC line (hot) Chassis (earth) ground or JST PHDR-10VS Housing JST SPHD-002T-P0.5 (28-24) JST SPHD-001T-P0.5 (26-22) J1 PFC Input Connector (control & signals) 9 10 1 2 Figure 2. Connector J1 & J2 Pin Function 1 2 3 4 5 6 7 8 9 10 Input AC OK - "emitter" Input AC OK - "collector" Global DC OK - "emitter" Global DC OK - "collector" Spare Global inhibit/optional enable logic "1" Global inhibit/optional enable logic "0" Global inhibit/optional enable return +5 VSB housekeeping +5 VSB housekeeping return Connector Kit Part No.: 70-841-023 Pin Function 1 2 3 4 5 6 7 8 9 10 5 Vcc bus Serial data signal (SDA) Secondary return (COM) Serial clock signal (SCL) Address bit 2 (A2) No connection Address bit 1 (A1) No connection Address bit 0 (A0) No connection S2 Module 240 W DC Output Control & Signals (Single output) 1.00.25 V ADJ 5.30.5 V+ 29.80.2 37.50.3 32.50.3 36.50.3 36.50.3 V- CAPS HEIGHT 4.50.3 12.5 MAX 3.0 MAX 0.8 - 1.5 1.60.16 130.01.5 1 2 9 10 Pin Function 1 2 3 4 5 6 7 8 9 10 No connection No connection Current share Module inhibit return Module ISO inhibit SCOM -RMT sense Margin Remote margin / V prog. +RMT sense MP Series Data Sheet SK Module 1000 W 12/24 Volt Output: 52.40 -0.30 +0.30 48 V Output: DC Output Control & Signals (Single output) 34.700.50 122.00 0.5 Pin Function 1 2 3 4 5 6 7 8 9 10 No connection No connection Current share Module inhibit return Module ISO inhibit SCOM -RMT sense Margin Remote margin / V prog. +RMT sense Dual Module DC Output Control & Signals (Dual output) Pin Function 1 2 3 4 5 6 7 8 9 10 -RMT sense V2 +RMT sense V2 No connection Module inhibit rtn Module ISO inhibit SCOM -RMT sense V1 No connection No connection +RMT sense V1 MP Series Data Sheet MP Series MP04/09 (400/600; 550/1100 Watts Max) Case Size: MP04/09: 10.11" x 3.5" x 1.57" (256.9 mm x 88.9 mm x 40.0 mm) Weight: MP04/09 Case: 1.96 lbs * Single O/P: 0.22 lb. * Dual O/P: 0.16 lb. * Blank: 0.06 lb. Notes: 1. Input: IEC 60320 C13 (for IEC connector) Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4 - 0.5 Nm); Wire: 12 - 16 AWG; Wire Strip Length: 0.354" (9.0 mm) 2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts. Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and SPHD002T-PO.5 (JST) pins. 3. Output Module Connectors: All single O/P modules are M4 x 10 mm screws; tighten between 6.94 to 8.68 lb-in (8.0 to 10.0 kg-cm). Dual O/P module is PUSH IN conductor connector; Wire Strip Length: 0.315" (8.0 mm); Control signal connector: Refer to Item 2. 4. Chassis Material: Steel with chemical film coating (conductive). 5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138" (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m) 6. All dimensions are in millimeters and inches, and are typical. MP Series Data Sheet MP10 (1000/1200 Watts Max) MP16 (1200/1800 Watts Max) Case Size: MP10/16: 10.11" x 5" x 1.57" (256.9 mm x 127 mm x 40.0 mm) Weight: MP10/16 Case: 2.78 lbs * Single O/P: 0.22 lb. * Dual O/P: 0.16 lb. * Blank: 0.06 lb. Notes: 1. Input: IEC 60320 C13 (for IEC connector) Barrier Type DECA Switchlab MT300-50003 (for terminal block connector); Max Torque: 4.0 lb-in (0.4 - 0.5 Nm); Wire: 12 - 16 AWG; Wire Strip Length: 0.354" (9.0 mm) 2. Control Connectors (J1 and J2): 10-position housing, brass, matte tin-plated contacts.Mates with housing 2050S1000 (Landwin) with 2053T011P (Landwin) pins or housing PHDR-IOVS (JST) and SPHD002T-PO.5 (JST) pins. 3. Output Module Connectors: All single O/P modules are M4 x 10 mm screws; tighten between 6.94 to 8.68 lb-in (8.0 to 10.0 kg-cm). Dual O/P module is PUSH IN conductor connector; Wire Strip Length: 0.315" (8.0 mm); Control signal connector: Refer to Item 2. 4. Chassis Material: Steel with chemical film coating (conductive). 5. Customer Mounting: Screw M4-type mounting holes; Max. Penetration is 0.138" (3.5 mm); Max. Torque: 8.85 lb-in (1.0 N-m) 6. All dimensions are in millimeters and inches, and are typical. MP Series Data Sheet MP HUP Module The MP HUP module is intended for use on MP09 with high efficiency module (SK*) configurations. In such case, only one HUP can be used per case. Its application is limited with MP09 and MP04 configurations and may have multiple HUP's inserted. The HUP module shall provide additional 224F bulk capacitance (typ.). Typical hold-up time increase with HUP module in MP09 case and SK* module is 10ms at 500W load. 73-950-002 Actual MP HUP Module and MP09 Configuration MP09 Config with HUP at Slot1 Typical HUP Response with MP09-SKW Configuration MP Series Data Sheet Typical HUP Response with MP09-S2* Configuration WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. Specifications subject to change without notice. (c) 2019 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com MP Series-DS 22May2019