www.clare.com
2R11
LCA110
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25˚ C
Parameter Ratings Units
Blocking Voltage 350 VP
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate Linearly 1.33 mW / ºC
2 Derate Linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
AC/DC Confi guration, Continuous 1-IL
- - 120
mA DC Confi guration, Continuous 1- - - 200
Peak t=10ms ILPK - - 350
On-Resistance 2
AC/DC Confi guration IL=120mA RON
-2335
Ω
DC Confi guration IL=200mA - 7 10
Off-State Leakage Current VL=350VPILEAK --1µA
Switching Speeds
Turn-On IF = 5mA, VL = 10V ton --3ms
Turn-Off toff --3ms
Output Capacitance VL=50V, f=1MHz COUT -25 -pF
Input Characteristics
Input Control Current IL = 120mA IF--2mA
Input Dropout Current - IF0.4 - - mA
Input Voltage Drop IF = 5mA VF0.9 1.2 1.4 V
Reverse Input Current VR = 5V IR- - 10 µA
Common Characteristics
Capacitance, Input to Output - CI/O -3 -pF
1 If both poles operate, the load current must be derated so that the package power dissipation value is not exceeded.
2 Measurement taken within 1 second of on-time.
Electrical Characteristics @ 25ºC