BUCCANEER FOR DATA 4000 Series - Simplex LC Fiber Buccaneer Sealed to IP66 IP68 and IP69K when mated IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks Simplex LC-Type Interface Cabled Versions: 0S1, 0M1, 0M3 Cable range from 5 to 450M Diameter over coupling ring 19.7mm Flex, Flex In-Line and Rear Panel 92 Buccaneer for Data Colour coded O-rings & washers for easy identificaiton purposes Secure, proven locking system Flame Retardant moulding material - Polyamide UL94-V0 Tamper proof construction Sealing caps available to maintain IP68 rating EN60068-2-52 Test Kb Salt Mist (Cyclic) Marine Severity Level 1 BUCCANEER FOR DATA 4000 Series - Simplex LC Fiber Buccaneer Patchcords with IP68 connectors Available in 5 - 450m lengths Supplied with LC fiber plug 0S1, 0M1 or 0M3 cable options Termination options PXF4050XXX Patchcords with IP68 connectors Available in 5 - 450m lengths Supplied with LC fiber plug 0S1, 0M1 or 0M3 cable options Termination options PXF4051XXX Patchcords with IP68 connectors Available in 5 - 450m lengths Supplied with LC fiber plug 0S1, 0M1 or 0M3 cable options Termination options PXF4054XXX Patchcords with IP68 connectors Available in 5 - 450m lengths Supplied with LC fiber plug 0S1, 0M1 or 0M3 cable options Termination options PXF4055XXX Rear Panel Mounting Connector LC fiber adapter Leaded with LC connector Socket variant mates with PXF4050 type cables PXF4053XXX Part no. Description PXF4053 IP-Sealed LC Type, Rear Panel Mounted, LC Connector at Rear. Buccaneer for Data 93 BUCCANEER FOR DATA 4000 Series - Simplex LC Fiber Buccaneer Flex Cable Connector Mates with Flex In-Line or Panel mounting versions PXF4051, PXF4053 30 turn locking ring Supplied without LC Connector PXF4050 In-Line Flex Cable Connector Mates with Flex Cable connector PXF4050 For In-Line connection Supplied without LC Connector PXF4051 Rear Panel Mounting Connector Mates with Flex Cable connector PXF4050 Rear Panel Mounting Single hole fixing Supplied without LC Connector PXF4053 Accessories Sealing caps to maintain IP rating when connectors are not in use Part no. Description PXP4082 Sealing cap for use with PXF4051 PXP4083 Sealing cap for use with PXF4053's PXP4081 O-ring & washer pack 94 Buccaneer for Data Part no. Description PXP4089/WH PXP4089/RD PXP4089/BL PXP4089/YL PXP4089/GN White coloured O-ring and washer pack Red coloured O-ring and washer pack Blue coloured O-ring and washer pack Yellow coloured O-ring and washer pack Green coloured O-ring and washer pack Sealing cap for use with PXF4050's BUCCANEER FOR DATA 4000 Series - Simplex LC Fiber Buccaneer Cables & connectors Mechanical Sealing Panel Mount Nut Operating temperature Salt Mist Optical IEC 61753-1 Max Insertion Loss AVG Insertion Loss IP69K, DIN40050-9 IP68, EN60529:1992+A2:2013 (10m depth for 2 weeks) IP66, EN60529:1992+A2:2013 1.0 - 1.1NM (91lb.in) -25C to +70C EN60068-2-52 Test Kb Salt Mist (Cyclic) Marine Severity Level 1 0.2db } single mode 0.1db } single mode Material: Flex and panel types: Body Mouldings: Flammability Rating: UV Resistance: Polyamide UL94v-0 To EN 500021:1999 O Rings: Silicone Panel Sealing O Ring: Silicone RoHS Compliant Fiber Specification - SECTION OSI Fiber type Item Mode field diameter Cladding diameter Core concentricity error Cladding non-circularity Coating diameter Coating-cladding concentricity error Cut-off wavelength Uncabled fiber macrobending loss Min. proof stress Dynamic fatigue parameter Detail / Wavelength Range of nominal values Tolerance Specification G.657A2 (OS1) 1310mm 8.6m -9.5m 0.4 m Nominal Tolerance 125.0m 0.7 m 0.5m 1% Nominal Tolerance 245m 10m 12.5m 1260 nm 15 10 10 1 0.03 0.1 0.1 0.2 0.69 GPa 20 1300 nm 1324 nm 0.092 ps/nm2 xkm Radius(mm) Number of turns Max. at 1550nm(dB) Max. at 1625 nm (dB) Chromatic dispersion coefficient 0min 0max S0max Other parameters meet standard ITU-T G.657 Fiber 7.5 1 0.5 1.0 Tight Buffer (LSZH) Aramid Yarn Outer Sheath (LSZH Yellow) 0.85 0.05 2.0 0.1 Optical Cable Specification Structure Parameter Tight buffer Strength member Outer sheath Transmission Performance Attenuation coefficient Macrobending loss Other performances Min. bending radius of work Other parameter meet standard Material Outer diameter Material LSZH 0.85mm0.05mm Aramid yarn Sheath material Sheath color Min. sheath thickness Dimension LSZH Yellow(Pantone 136C) Chromatic aberration E: 4.0 0.3mm 2.0mm0.1mm Wavelength 1310nm~1625nm Maximum at 1383 nm 3 nm Wavelength 1550nm 0.4 dB/km 0.4 dB/km 0.3 dB/km Radius(mm) Number of turns Max. at 1550 nm(dB) Max. at 1625 nm (dB) 15 10 0.03 0.1 10 1 0.1 0.2 7.5 1 0.5 1.0 10mm IEC60794-2-50, YD/T1258.2, ITU-T G.657 Buccaneer for Data 95 BUCCANEER FOR DATA 4000 Series - Simplex LC Fiber Buccaneer Fiber Specification - SECTION OMI Fiber type Item / Detail Specification 62.5/125(A1b) (OM1) Core diameter Normal value Tolerance 62.5 m 3 m Cladding diameter Nominal Tolerance 125.0m 2 m 3m 2% 6% Primary coating diameter (uncoloured) Nominal Tolerance Primary coating-cladding concentricity error 245m 10m 12.5m Core-cladding concentricity error Cladding non-circularity Core non-circularity Uncabled fiber macrobending loss Radius(mm) Number of turns At wavelengths 850 nm and 1300nm (dB) Min. proof stress Dynamic fatigue parameter 37.5 100 0.5 Fiber 0.69 GPa 20 Minimum modal bandwidth- length Product for overfilled launch Wavelength 850 nm Wavelength 1300 nm Other parameters meet standard IEC 60793-2-10 Tight Buffer (PVC) 200 MHzkm 500 MHzkm Aramid Yarn Outer Sheath (PVC Orange) 0.85 0.05 2.0 0.1 Optical Cable Specification Item Structure Parameter Tight buffer Strength member Outer sheath Transmission Performance Attenuation coefficient Other performances Min. bending radius of work Other parameter meet standard 96 Buccaneer for Data Specification Material Outer diameter Material PVC 0.85mm0.05mm Aramid yarn Sheath material Sheath color Min. sheath thickness Dimension PVC Orange(Pantone 164C) Chromatic aberration E: 4.0 0.3mm 2.0mm0.1mm Wavelength 850m Wavelength 1300nm 3.5 dB/km 1.5 dB/km 30mm IEC60794-2-50, YD/T1258.2 BUCCANEER FOR DATA 4000 Series - Simplex LC Fiber Buccaneer Fiber Specification - SECTION OM3 Fiber type Item / Detail Specification 50/125(OM3) Core diameter Normal value Tolerance 50 m 2.5 m Cladding diameter Nominal Tolerance 125.0m 2 m 3m 2% 6% Primary coating diameter (uncoloured) Nominal Tolerance Primary coating-cladding concentricity error 245m 10m 12.5m Core-cladding concentricity error Cladding non-circularity Core non-circularity Uncabled fiber macrobending loss Min. mode bandwidth Min. proof stress Dynamic fatigue parameter Chromatic dispersion coefficient Other parameters meet standard Radius(mm) Number of turns Max. at 850 nm (dB) Max. at 1300 nm (dB) 15 2 0.1 0.3 7.5 2 0.2 0.5 Fiber Overfilled launch bandwidth at 850nm 1500 MHz. km Overfilled launch bandwidth at 1300nm 500 MHz. km Effective laser launch bandwidth at 850nm 2000 MHz. km 0.69 GPa 20 1295 nm 1340 nm 0.105ps/nm2xkm 0.000375(1590-0) ps/nm2xkm 0min 0max S0max(from1295nm01310nm) S0max(from1310nm01340nm) IEC 60793-2-10 Tight Buffer (LSZH) Aramid Yarn Outer Sheath (LSZH Aqua) 0.85 0.05 2.0 0.1 Optical Cable Specification Item Structure Parameter Tight buffer Strength member Outer sheath Specification Material Outer diameter Material LSZH 0.85mm0.05mm Aramid yarn Sheath material Sheath color Min. sheath thickness Dimension LSZH Aqua(Pantone 3248C) Chromatic aberration E: 4.0 0.3mm 2.0mm0.1mm Wavelength 850m Wavelength 1300nm 3.5 dB/km 1.5 dB/km Radius (mm) Number of turns Max. at 850 nm (dB) Max. at 1300 nm (dB) 15 2 0.1 0.3 Transmission Performance Attenuation coefficient Macrobending loss Other performances Min. bending radius of work Other parameter meet standard 7.5 2 0.2 0.5 10mm IEC60794-2-50, YD/T1258.2 Buccaneer for Data 97 BUCCANEER FOR DATA 4000 Series - Simplex LC Fiber Buccaneer PXF405 xx X XX Body Styles Cable Type Contact Type PXF4050 PXF4051 PXF4053 PXF4054 PXF4055 Blank = No cable A = OS1 (Singlemode) B = OM1 (Multimode) C = OM3 (Multimode) Blank = No cable AA = 1 (1M on chassis version only PXF4053) AA = 5 AB = 10 AC = 25 AD = 50 AE =100 AF = 150 AG = 200 AH = 300 AJ = 450 Examples: PXF4050 = Flex connector, no cable PXF4050AAA = Flex connector, OS1 single mode cable, 5 metre length to LC type connector PXF4053BAA = Panel mount connector, OM1 multi mode cable, 1 metre length to LC type connector 98 Buccaneer for Data