1
MEM Air Velocity Sensor – D6F-10A5-000/20A5-000/50A5-000
Compact, intelligent sensors
featuring MEMS
technology for precision mass
airflow measurement
Precision unidirectional mass airflow up to
50 LPM
Stable output across full scale
Horizontal mounting feature with
*NBR ‘O’ ring
Compact size 78 (L) x 30 (W) x 30 (H) mm
Low power consumption
Application Examples
• Industrial processes
• Oxygen concentrators / conservators
• Leak detection
• Spectroscopy
• Mass flow controllers
• Scientific / test equipment
• Environmental comfort controls
• Fuel cell controls
Ordering Information
Item Term Ratings Unit
Power-supply voltage VCC 26.4 VDC
Output voltage VOUT 6 VDC
Electrical Performance
Recommended operation condition and DC characteristic
Rating
Absolute maximum rating
Item Term Condition MIN TYP MAX Unit
Power-supply voltage VCC – 10.8 26.4 VDC
Operating temperature TOPR -10 60 °C
Maximum output VOH VCC = 12VDC TO 24VDC 5 5.7 VDC
voltage IOH = 0.5MA
Minimum output VOL VCC = 12VDC TO 24VDC 0 1 VDC
voltage IOL = -0.5MA
Model Case Applicable Gas Flow Range Notes
D6F-10A5-000 Thermoplastic resin / Aluminium Alloy Air* 0 – 10 LPM Built-in orifice
D6F-20A5-000 Thermoplastic resin / Aluminium Alloy Air* 0 – 20 LPM Built-in orifice
D6F-50A5-000 Thermoplastic resin / Aluminium Alloy Air* 0 – 50 LPM Built-in orifice
D6F-CABLE1 Optional (recommended)
*Dry gas must not contain large particles, eg. dust, oil, mist.
2
MEM Air Velocity Sensor – D6F-10A5-000/20A5-000/50A5-000
Basic Performance
The flow velocity at 25°C,1 atmosphere
Operating Characteristics
0 to 50 min (Normal). L/min (Normal) volumetric flow rate at 0°C, 101 3kPa.
Measurement condition: Power-supply voltage 12±0.1VDC, ambient temperature 25±2°C and ambient humidity 25 to 75% RH.
Characteristics
Degree of Protection IP40
Applicable Gas Air
Electrical Connection Connector (3 wire)
Output Signal Analogue, 1-5VDC (load resistance 10kohm min)
Current Consumption Max 15mA (no load, VCC = 12 to 24VDC, VSS = GND = 0V, 25°C)
Repeat Accuracy +/- 3% FSD max, 25°C
Insulation Resistance 20Mohm min. (500VDC between lead terminals and case)
Dielectric Strength 500VAC, 50/60Hz for 1 minute (leakage current typ. <1mA) between lead terminals
Withstand Pressure 500 kPa
Operating Temperature -10 to +60°C (with no ice or dew condensation)
Operating Humidity 85%RH max. (with no ice or dew condensation)
Storage Temperature -40 to +80°C (with no ice or dew condensation)
Storage Humidity 85%RH max. (with no ice or dew condensation)
Weight 102.56g
D6F-10A5-000
Flow Rate L/min (normal) 02 46 810
Output Voltage (VDC) 1.00 ±0.12 1.75 ±0.12 2.60 ±0.12 3.45 ±0.12 4.25 ±0.12 5.00 ±0.12
D6F-20A5-000
Flow Rate L/min (normal) 048 121620
Output Voltage (VDC) 1.00 ±0.12 1.93 ±0.12 2.87 ±0.12 3.70 ±0.12 4.41 ±0.12 5.00 ±0.12
D6F-50A5-000
Flow Rate L/min (normal) 0 1020304050
Output Voltage (VDC) 1.00 ±0.12 2.45 ±0.12 3.51 ±0.12 4.20 ±0.12 4.66 ±0.12 5.00 ±0.12
3
MEM Air Velocity Sensor – D6F-10A5-000/20A5-000/50A5-000
Precautions
1. Avoid use in excessively dirty, wet environments
2. Do not use in the presence of flammable gases (e.g. hydrogen, methane, ethane and liquefied petroleum gas. In addition, do not use with
corrosive gases (eg chlorine, sulphur, acids, alkalis etc).
3. Install in the direction of the arrow indicated.
4. For best results (optimum accuracy), mount horizontally.
5. Use suitable M3 screws for mounting. Do not exceed a fixing torque of 0.59 Nm.
6. Do not modify D6F- in any way.
7. Do not place any object in or close to the inlet and outlet orifices.
8. Do not use the sensor in any of the following environments:
- a location that receives radiant heat from the sun or apparatus
- a place where intense light may radiate down
- where fast changing temperatures occur
- locations prone to freezing, high humidity, condensation
- places where large magnitudes of vibration or shock could occur
9. Noise countermeasures: VERY IMPORTANT: Take suitable precautions to minimise the effects and potential for induced electrical noise. Install
away from apparatus that generates strong high frequencies, surges and spikes. Take particular care to install away from AC power
transformers, live mains power lines and high power magnetic circuits. Attach a surge suppressor and a noise filter to the peripheral equipment.
10. Ensure good grounding is achieved by grounding the GND terminal to the peripheral equipments main ground frame connection and its
associated regulated power supply.
11. Do not make a direct solder connection to the integral terminals. It is recommended you use the optional cable ‘D6F-CABLE1’ for attachment
and to ensure correct connection.
12. D6F- is a precision component. Keep in original packaging and remove only when ready for installation. Damage may occur if subjected to
excessive force (e.g. dropped or kicked). Any item suspected to be damaged should be discarded.
13. Immediately following installation, a qualified person should perform checks to ensure safe, satisfactory operation.
Installation
Tighten screw with 0.59Nm or less torque. Use M3 pan head screw.
Please seal to INLET and OUTLET with the ‘O’ ring etc.
Please install the product as shown below.
Recommended ‘O’ ring for sealing inlet and outlet orifice
Material: NBR70 (recommended)
Example part number: JASO part number: CO 0003
Alternative manufacturers with similar DO and W dimensions may be used
4
MEM Air Velocity Sensor – D6F-10A5-000/20A5-000/50A5-000
3. GND
A (2:1)
NOTE1 Use an attached connector
Housing: MOLEX-51021
Terminal: MOLEX-50079
Wire: AWG26, 28
Citcuit number: Refer to enlargement A.
NOTE 2 Installation hole recomdended size.
2. V
OUT
1. V
CC
66 ±0.05
4-M3
Screw Hole 14 ±0.05
30 ±0.5
30 ±0.5 78 ±0.5
30 ±.05
6
3.7
Lot. No. Label Inlet
2-5
6 66 ±0.1
Outlet
2-14 ±0.1 4-3.2
through hole
A
Dimensions
All dimensions are shown in millimetres.
Black
Brown
Blue
1001.5
2003.5
1. V
CC
2. V
OUT
3. GND
D6F- Cable1 (Optional)
5
MEM Air Velocity Sensor – D6F-10A5-000/20A5-000/50A5-000
Warranty
Omron corporation manufactures products to the highest standards and warrants that all products it manufactures are free of defects and faulty
workmanship.
Please contact your local Omron representative for warranty information.
Specifications subject to change without notice. Any information supplied is believed to be accurate and reliable at the time of printing.
We provide application assistance personally and through our literature including our website for guidance only. It is the customers full
responsibility to determine suitability of product in any intended application.
Packaging
No. Name Material
1 D6F
2 Polyethylene bag Polyethylene
3 Box Coated board paper
4 Label (Bar code)
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.