Voltage rating AC 240 V; DC 48 V
Current ratings 0.05...10 A
Auxiliary circuit 0.5 A, AC 240 V, DC 28 V
Typical life 0.05...5 A: 3,000 operations at 2 x IN
6 ...8 A: 500 operations at 2 x IN
10 A 50 operations at 2 x IN
Ambient temperature -20...+60 °C (T 60)
Insulation co-ordination Rated impulse Pollution
(IEC 664 and 664 A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength Test voltage
(IEC 664 and 664A)
operating area AC 3,000 V
Insulation resistance >100 M (DC 500 V)
Interrupting capacity Icn 0.05 ... 2 A 6 x IN
2.5 ...10 A 5 x IN
Interrupting capacity INUN
(UL 1077) 0.05...4.5 A AC 250 V 200 A
5 A AC 250 V 1000 A
6...10 A AC 250 V 2000 A
0.05...10 A DC 48 V 200 A
Degree of protection operating area IP 40
(IEC 529/DIN 40050) terminal area IP 00
Vibration 10 g (57-500 Hz),±0.76 mm (10-57 Hz),
to IEC 68-2-6, test Fc,
10 frequency cycles/axis
Shock 25 g ( 11 ms)
to IEC 68-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
Humidity 240 hours at 95 % RH,
to IEC 68-2-3, test Ca
Mass approx. 10 g
Thermal Overcurrent Circuit Breakers 104/105/106-...
Description
Miniaturised single pole thermal circuit breaker with push-to-reset
tease free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Available in versions for PCB or panel mounting, snap-in or
threadneck, or as an integral type. Approved to CBE standard EN
60934 (IEC 934). For higher current ratings see type 1140.
Technical data
Authority Voltage ratings Current ratings
VDE (EN 60934), SEV AC 240 V 0,05...8 A
DC 48 V 0.05...10 A
Demko AC 250 V, DC 28 V 0.05...10 A
CSA, UL AC 250 V, DC 48 V 0.05...10 A
Semko AC 250 V, DC 48 V 0.1...10 A
Kema (EN 60934) AC 240 V 0,05...8 A
DC 48 V 0.05...10 A
Circuit breakers with -Si51 not approved
Approvals
104-... 105-... 106-...
Typical applications
Motors, transformers, solenoids, printed circuit boards, hand-held
machines and appliances.
Ordering information
Type No.
104 PCB mounting type (-PR), or integral type (-P30/P10)
105 snap-in panel mounting
106 threadneck panel mounting with hex and knurled nut *
106-M1 threadneck mounting for standard fuseholder cutout *
Terminal design
P10 blade terminals A6.3-0.8
P30 blade terminals A2.8-0.8
PR solder terminal pins for PCB mounting (type 104 only)
Shunt terminal (optional)
A3 same as main terminals (up to IN 6 A/3 A max. load)
Auxiliary contacts (optional)
Si51 type 104 only
Current ratings
0.05...10 A
106 - P30 - - - 5 A = ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
* mounting hardware bulk shipped
Please enquire for packaging quantities
Current Internal Current Internal
rating (A) resistance () rating (A) resistance ()
0.05 285 1.8 0.28
0.08 134 2 0.25
0.1 81 2.5 0.18
0.2 22 3 0.11
0.3 8.7 3.5 0.076
0.4 5.5 4 0.067
0.5 3.3 4.5 0.051
0.6 2.45 5 0.05
0.7 1.6 6 0.05
0.8 1.45 7 0.05
1 0.9 8 0.05
1.2 0.6 10 0.05
1.5 0.4
Standard current ratings and typical internal resistance values
26
1
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com Issue E
104-PR 104-P30
Dimensions
Thermal Overcurrent Circuit Breakers 104/105/106-...
105-P30
104-PR-(A3-)Si51
8
±0.2
1231
2
cut-out dimensions
hole for
mounting screw M2
usable depth 4.5 mm 6.5
11
9
19
ø4
9.5 OFF
ø7
6.5 ON
max. 3
1.2
9.5
27.6
29.6
blade terminals
DIN 46244-A2.8-0.8
Ø 2.2
6.5
7.3
104-P30
7...10 A
104-P30-A3
0.05...6 A
10 OFF
ø7
6.5 ON
max. 3
1.2
3.5
27.6
31.6
23
21
21.5
17.5
23.5
5
9.5
12.5
ø0.9
terminal design for
correct stand-off distances
9
11
17.5
19
4.5
0.8
1
21.5
9.5
23.5
5
12.5
ø4
1.2
max. 3 9.5 OFF
6.5 ON
3.5
27.6
29.6
1
11
0.8
9
17.5
21
4.5
0.5
30
8
±0.2
17.5
0.5
30
9.5
terminal design for
correct stand-off distances
104-PR
104-PR-A3
0.05...6 A
104-PR
7...10 A
11
blade terminals
DIN 46244-A2.8-0.8
d
6.5 ON
ø7
9.5 OFF
max. 3
1.2
9.5 2
27.6
29.6
19
25
14
mounting hole
b
a
105-P30
7...10 A
105-P30-A3
0.05...6 A
3.8
d
0.8
1.0
1.5
2-3
a
21.9
22
22.1
22.2
b
11.3
+0.3
ø4
ø4
12
mounting holes
19
21
104-PR-Si51
104-PR-A3-Si51
0.05...6 A
104-PR-Si51
7...10 A
mounting holes
8
±0.2
123
9.5
12
8
±0.2
4545
ø1
ø1.5 ø1.5
ø1
ø1.5
ø1.5
ø1.5
(A3)
27
1
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com Issue E
106-P30
106-M1
Dimensions
Thermal Overcurrent Circuit Breakers 104/105/106-...
Installation drawings
10.5 ON
13.5 OFF
3/8-27UNS-2A
tightening torque 0.8 Nm
ø4
0.7
7
27.6
9.5
19
1.2
max. 3
11
blade terminals
DIN 46244-A2.8-0.8
15.7
SW14
8.8
9
mounting hole
9.6
- 0.1
8.9
- 0.1
mounting hole
ø16
±0.1
11,3
+0.15
- 0.1
ø18.8
panel thickness >0.8
106-P30
7...10 A
106-P30-A3
0.05...6 A
tightening torque 0.5 Nm
3.8
mounting area
8
8
operating area
max. 2
8
8
mounting area
8
8
operating area
max. 2
8
8
mounting area
8
8
operating area
8
8
104-…
105-…
106-…
28
1
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com Issue E
104/105/106-P10
104/105/106-P10-A3
104/105/106-P30-A3
Thermal Overcurrent Circuit Breakers 104/105/106-...
Terminal design
Accessories
Water splash cover (transparent)/knurled nut assembly
(type 106-... only)
X 201 285 01
Degree of protection IP 64
0.05...6 A
0.05...6 A
5.3
0.05...6 A 7...10 A
6.3
10
blade terminals
DIN 46244-A6.3-0.8
9.5
polarizing tooth
polarizing tooth
Types 104 Types 104-...-A3 Types 104-...-A3-Si51
105 105-...-A3
106 106-...-A3
Internal connection diagrams
Typical time/current characteristics at +23 °C
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also section 9
– Technical information.
Ambient temperature °C -20 -10 0 +23 +40 +50 +60
Multiplication factor 0.76 0.84 0.92 1 1.08 1.16 1.24
12468102040
Trip time in seconds
… times rated current
0.05 - 6 A
7 - 10 A
10000
1000
100
10
1
0.1
1
2
5
4
1
2
1
2