CSM_E3S-A_DS_E_10_1
1
Built-in Amplifier Photoelectric Sensor (Medium Size)
E3S-A
Ordering Information
Built-in Amplifier Photoelectric Sensors
*1. Through-beam Sensors are normally sold in sets that include both the Emitter and Receiver.
Orders for individual Emitters and Receivers are accepted.
*2. Values in brackets are the minimum required distance between the Sensor and Reflector.
Be sure to read Safety Precautions
on page 10.
Sensing method Appearance
Connection
method Sensing distance Functions Model
NPN output PNP output
Through-beam
Sensors *1
Pre-wired
---
E3S-AT11 2M
Emitter
E3S-AT11-L
Receiver
E3S-AT11-D
E3S-AT31 2M
Emitter
E3S-AT31-L
Receiver
E3S-AT31-D
E3S-AT21 2M
Emitter
E3S-AT21-L
Receiver
E3S-AT21-D
E3S-AT41 2M
Emitter
E3S-AT41-L
Receiver
E3S-AT41-D
Connector
(M12) ---
E3S-AT16
Emitter
E3S-AT16-L
Receiver
E3S-AT16-D
E3S-AT36
Emitter
E3S-AT36-L
Receiver
E3S-AT36-D
Pre-wired
---
E3S-AT61 2M
Emitter
E3S-AT61-L
Receiver
E3S-AT61-D
E3S-AT81 2M
Emitter
E3S-AT81-L
Receiver
E3S-AT81-D
E3S-AT71 2M
Emitter
E3S-AT71-L
Receiver
E3S-AT71-D
E3S-AT91 2M
Emitter
E3S-AT91-L
Receiver
E3S-AT91-D
Connector
(M12) ---
E3S-AT66
Emitter
E3S-AT66-L
Receiver
E3S-AT66-D
E3S-AT86
Emitter
E3S-AT86-L
Receiver
E3S-AT86-D
Retro-reflective
Sensors
Pre-wired
*2
--- E3S-AR11 2M E3S-AR31 2M
E3S-AR21 2M E3S-AR41 2M
Connector
(M12) --- E3S-AR16 E3S-AR36
Pre-wired
--- E3S-AR61 2M E3S-AR81 2M
E3S-AR71 2M E3S-AR91 2M
Connector
(M12) --- E3S-AR66 E3S-AR86
Red light Infrared light
Horizontal
7 m
Timer
Self Diagnosis
Tu r b o
External
Diagnosis
Vertical
Timer
Self Diagnosis
Tu r b o
External
Diagnosis
Horizontal
2 m
(100 mm)
Timer
Self Diagnosis
Tu r b o
External
Diagnosis
Vertical
Timer
Self Diagnosis
Tu r b o
External
Diagnosis
E3S-A
2
*3. The following models are available with 200-mm sensing distances: E3S-AD64.
Accessories (Order Separately)
Insert-type Long Slit
Mutual Interference Prevention Filters
Reflectors/Other Accessories
Note: When using any Reflector other than the provided one, use a sensing distance of approximately 0.7 times the typical value as a guide.
* Values in brackets are the minimum required distance between the Sensor and Reflector.
Sensing method Appearance
Connection
method Sensing distance Functions Model
NPN output PNP output
Diffuse-reflective
Sensors
Pre-wired
--- E3S-AD13 2M E3S-AD33 2M
E3S-AD23 2M E3S-AD43 2M
--- E3S-AD11 2M E3S-AD31 2M
E3S-AD21 2M E3S-AD41 2M
--- E3S-AD12 2M E3S-AD32 2M
E3S-AD22 2M E3S-AD42 2M
Connector
(M12) ---
E3S-AD18 E3S-AD38
E3S-AD16 E3S-AD36
E3S-AD17 E3S-AD37
Pre-wired
--- E3S-AD63 2M *3 E3S-AD83 2M
E3S-AD73 2M E3S-AD93 2M
--- E3S-AD61 2M E3S-AD81 2M
E3S-AD71 2M E3S-AD91 2M
--- E3S-AD62 2M E3S-AD82 2M
E3S-AD72 2M E3S-AD92 2M
Connector
(M12) ---
E3S-AD68 E3S-AD88
E3S-AD66 E3S-AD86
E3S-AD67 E3S-AD87
Slit width Sensing distance Minimum sensing
object (typical) Model Quantity Remarks
0.5 mm × 11.1 mm 500 mm 0.2-mm dia.
E39-S46
1 of each for Emitter/
Receiver (4 Slits total) Slits can be used with the E3S-
AT@@ Through-beam
Sensor.Page 10
1 mm × 11.1 mm 1.1 m 0.4-mm dia.
2 mm × 13.6 mm 2.5 m 0.8-mm dia. 1 of each for Emitter/
Receiver (2 Slits total)
Sensing distance Model Quantity Remarks
2.4 m E39-E6 2 of each for Emitter/Receiver
(4 Filters total)
Can be used with the E3S-AT@@ Through-beam Sensor.
Page 11
Name Sensing distance (typical) Model Quantity Remarks
Reflectors 2 m (100 mm) *
(rated value) E39-R1 1 Provided with E3S-AR@@ Retro-reflective Sensor.
Small Reflectors 1.3 m (100 mm) * E39-R3 1 ---
600 mm (70 mm) *E39-R4 1 ---
Tape Reflectors
450 mm (100 mm) *E39-RS1 1
Enables MSR function.700 mm (100 mm) *E39-RS2 1
900 mm (100 mm) * E39-RS3 1
Optical Axis
Confirmation Reflector --- E39-R5 1Used to check optical axis for the E3S-AT@@
Through-beam Sensor.
100 mm (wide view)
Timer Self Diagnosis
200 mm
Timer
Self Diagnosis
Turbo
700 mm
Timer
Self Diagnosis
Turbo
100 mm (wide view)
200 mm
700 mm
Vertical
100 mm (wide view)
Timer Self Diagnosis
200 mm
Timer
Self Diagnosis
Turbo
700 mm
Timer Self Diagnosis
100 mm (wide view)
200 mm
700 mm
3
E3S-A
Mounting Brackets/Other
Some Mounting Brackets are provided with the Sensor. Order other Mounting Brackets separately if required.
Note: If a Through-beam Model is used, order two Mounting Brackets, one for the Emitter and one for the Receiver.
*1. Mount a Sensor with a Connector carefully because the Sensor I/O Connector will come into contact with the Mounting Bracket or Mounting Plate.
*2. Usage is not possible with Sensors with Connectors.
Sensors I/O Connectors
Sensors I/O Connectors
Note: When using Through-beam models, order one connector for the Receiver and one for the Emitter.
Appearance Model Quantity Remarks
E39-L69 1
Provided with E3S-A Horizontal Sensors.
Two Brackets are provided with a Through-
beam Sensor.
E39-L70 1
Provided with E3S-A Vertical Sensors.
Two Brackets are provided with a Through-
beam Sensor.
E39-L59 1Provided with E3S-A Vertical Pre-wired
Sensors.
E39-L81 1Provided with E3S-A Vertical ConnectSor
Sensors.
E39-L97 *11 Protective Cover for Horizontal Sensors
E39-L98 *21 Protective Cover for Vertical Sensors
E39-L60 1
Close Mounting Plate:
Provided with E3S-A Connector Sensors.
Two Plates are provided with a Through-
beam Sensor.
Model Quantity Remarks
E39-G2 1 Provided with product.
Cable Appearance Cable type Model
Standard
2 m
3-wire
XS2F-D421-DC0-F
5 m XS2F-D421-GC0-F
2 m XS2F-D422-DC0-F
5 m XS2F-D422-GC0-F
Straight
L-shaped
E3S-A
4
Ratings and Specifications
*1. Values in brackets are the minimum required distance between the Sensor and Reflector.
*2. National Electrical Manufacturers Association
Sensing method Through-beam
Sensors
Retro-reflective
Sensors
(with MSR function)
Diffuse-reflective Sensors
Item
Model
E3S-AT11, 16, 21, 31,
36, 41, 61, 66, 71, 81,
86, 91
E3S-AR11, 16, 21, 31,
36, 41, 61, 66, 71, 81,
86, 91
E3S-AD13, 18, 23, 33,
38, 43, 63, 68, 73, 83,
88, 93
E3S-AD11, 16, 21, 31,
36, 41, 61, 66, 71, 81,
86, 91
E3S-AD12, 17, 22, 32,
37, 42, 62, 67, 72, 82,
87, 92
Sensing distance 7 m 2 m (100 mm) *1
(When using E39-R1)
100 mm (wide view)
(white paper 100 ×
100 mm)
10 to 200 mm
(white paper 100 ×
100 mm)
700 mm
(white paper 200 ×
200 mm)
Standard sensing object Opaque:
10-mm dia. min.
Opaque:
75-mm dia. min. ---
Differential travel --- 20% max. of sensing
distance
10% max. of sensing
distance
20% max. of sensing
distance
Directional angle Both Emitter and
Receiver: 3° to 15°3 to 10°---
Light source (wavelength) Red LED (700 nm) Infrared LED (880 nm) Red LED (700 nm) Infrared LED (880 nm)
Power supply voltage 10 to 30 VDC, including ripple (p-p) 10%
Current consumption
Both Emitter and
Receiver: 20 mA max.
(plus approx. 15 mA with
turbo function)
30 mA max. (plus
approx. 15 mA with
turbo function)
35 mA max.
30 mA max. (plus
approx. 15 mA with
turbo function)
35 mA max.
Control output Load power supply voltage: 30 VDC max., Load current: 100 mA max. (residual voltage: 1 V max.)
Open-collector output (NPN or PNP depending on model), Light-ON/Dark-ON selectable
Self-diagnostic output (Only
on Sensors with self-diagnos-
tic outputs)
(Only Sensors with self-diagnostic function) Load power supply voltage: 30 VDC max.,
Load current: 50 mA max. (residual voltage: 1 V max.),
Open-collector output (NPN or PNP depending on model)
External
diagnostic
input
(Only on
Sensors with
external
diagnostic
outputs)
Input
voltage
NPN
with Emitter OFF: 0 V short-circuit or 1.5 V max.
(source current: 1 mA max.)
with Emitter ON: Open
(leakage current: 0.1 mA max.)
PNP
with Emitter OFF: +DC short-circuit or 1.5 VDC
max. (sink current: 3 mA max.)
with Emitter ON: Open
(leakage current: 0.1 mA max.)
---
Response
time 0.5 ms max.
Protection circuits
Power supply reverse
polarity protection,
Output short-circuit
protection
Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention
Response time Operation or reset: 0.5 ms max.
Sensitivity adjustment Two-turn endless adjuster with an indicator
Timer function (Only on Sen-
sors with the timer function) 0 to 100 ms OFF-delay variable adjuster
Turbo function (Only on Sen-
sors with the turbo function) Yes (with turbo switch) ---
Ambient illumination (Receiv-
er side)
Incandescent lamp: 5,000 lx max.
Sunlight: 10,000 lx max.
Ambient temperature Operating: 25°C to 55°C (with no icing or condensation)
Storage: 40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 35% to 85% (with no condensation)
Storage: 35% to 95% (with no condensation)
Insulation resistance 20 MΩ min. at 500 VDC between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance
(destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction) Destruction: 500m/s2, 3 times each in X, Y, and Z directions
Degree of protection IEC IP67; NEMA: 4X (indoors only) *2
Connection method Pre-wired (standard length: 2 m) or M12 connector
Weight (packed state)
Pre-wired cable:
Approx. 150 g
Connector: Approx. 70 g
Pre-wired cable:
Approx. 110 g
Connector: Approx. 60 g
Pre-wired cable: Approx. 90 g
Connector: Approx. 50 g
Material
Case PBT
Lens Denatured polyallylate
Mounting
Bracket Stainless steel (SUS304)
Accessories Mounting bracket (with screws), Sensitivity adjustment driver, Sensitivity adjusting knob, Instruction sheet, Close mounting plate
(only for Sensors with connectors), and Reflector (only for Retro-reflective Sensors)
5
E3S-A
Engineering Data (Reference Value)
Parallel Sensing Range
Through-beam Sensors Through-beam Sensors Through-beam Sensors
E3S-AT@@ E3S-AT@@ + E39-S46
(Slit Sold Separately)
E3S-AT@@ + E39-E6
(Filter Sold Separately)
Parallel Sensing Range Sensing Range
Retro-reflective Sensors Diffuse-reflective Sensors
E3S-AR@@ + E39-R1 (with Reflector) E3S-AD@1/AD@2/AD@3/AD@6/AD@7/AD@8
Excess Gain vs. Set Distance
Through-beam Sensors Retro-reflective Sensors
E3S-AT@@ E3S-AR@@ + E39-R1 (with Reflector)
500
400
300
200
100
0
100
200
300
400
500
2 4 6 8
Distance X (m)
Distance Y (mm)
Y
X
200
100
0
100
200
1 2 3 4 5 6 7 8
Slit width: 1 mm
Slit width: 0.5 mm
Slit width: 2 mm
Y
X
Distance X (m)
Distance Y (mm)
200
100
0
100
200
1 2 3 4 5 6
Y
X
Distance X (m)
Distance Y (mm)
Y
X
100
80
60
40
20
0
20
40
60
80
100
0.5 1.0 1.5 2.0 2.5
E39-R1 Reflector
Distance X (m)
Distance Y (mm)
Y
X
40
30
20
10
0
10
20
30
40
200
400 600 800
Sensing object: white paper
E3S-AD@1/@3/@6/@8: 100 × 100 mm
E3S-AD@2/@7: 200 × 200 mm
E3S-AD@1/@6
E3S-AD@3/@8
E3S-AD@2/@7
Distance X (m)
Distance Y (mm)
500
300
100
50
30
10
5
3
1
0 3 5 7 10
Oper-
ating
level
Distance (m)
Excess gain ratio (times)
100
50
30
10
5
3
1
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6
E39-R1 Reflector
Oper-
ating
level
Distance (m)
Excess gain ratio (times)
E3S-A
6
I/O Circuit Diagrams
NPN Output
Diffuse-reflective Sensor Diffuse-reflective Sensor Sensing Object Size vs. Sensing
Distance
E3S-AD@1/AD@2/AD@3/AD@6/AD@7/
AD@8 (Detection of White Paper)
E3S-AD@1/AD@2/AD@3/AD@6/AD@7/
AD@8 (Detection of Black Paper)
E3S-AD@1/AD@2/AD@3/AD@6/AD@7/
AD@8
Model Operation
mode Timing charts
Mode
selector
switch
Output circuit
E3S-AT11 *
E3S-AT16 *
E3S-AT61 *
E3S-AT66 *
E3S-AR11
E3S-AR16
E3S-AR61
E3S-AR66
E3S-AD11
E3S-AD16
E3S-AD61
E3S-AD66
E3S-AD12
E3S-AD17
E3S-AD62
E3S-AD67
E3S-AD13
E3S-AD18
E3S-AD63
E3S-AD68
Light-ON L Side
(LIGHT ON)
Through-beam Receivers, Retro-reflective Sensors, Diffuse-reflective
Sensors
Dark-ON D Side
(DARK ON)
Through-beam Emitters
* Models numbers for Through-beam Sensors (E3S-AT@@) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3S-AT11-L 2M), the model number of the Receiver, by adding "-D"
(example: E3S-AT11-D 2M). Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
500
300
100
50
30
10
5
3
1
0.50 0.2 0.4 0.6 0.8 1 1.2
E3S-AD@3/@8
E3S-AD@2/@7
E3S
-AD@1/@6
Oper-
ating
level
Distance (m)
Sensing object: White paper
E3S-AD@1/@3/@6/@8: 100 × 100 mm
E3S-AD@2/@7: 200 × 200 mm
Excess gain ratio (times)
100
50
30
10
5
3
1
0.5
0.3
0.1
0 200 400 600 800
E3S-AD@3/@8
E3S-AD@2/@7
E3S
-AD@1/@6
Oper-
ating
level
Distance (mm)
Sensing object: Black paper
E3S-AD@1/@3/@6/@8: 100 × 100 mm
E3S-AD@2/@7: 200 × 200 mm
Excess gain ratio (times)
1.2
1
0.8
0.6
0.4
0.2
0
Side of object (mm)
50 × 50 100 × 100 200 × 200 300 × 300
E3S-AD@1/@6
E3S-AD@3/@8
OFF
ON
OFF
ON
OFF
ON
E3S-AD@2/@7
Sensing object: white paper
Distance (m)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between brown and black)
Output
transistor
Load
(e.g., relay)
Connector Pin Arrangement
Note: Pin 2 is not used.
1
3
4
Light
indi-
cator
Stability
indicator
Photo-
electric
Sensor
main
circuit
Z
D
Load
Brown
Blue
Black
(Control
output)
(Relay)
100 mA max. 10 to
30 VDC
(red)
(green)
3
1
24
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between brown and black)
Output
transistor
Load
(e.g., relay)
Connector Pin Arrangement
Note: Pins 2 and 4 are not used.
3
1
Power
indica-
tor Photo-
electric
Sensor
main
circuit
Brown
Blue
10 to
30 VDC
(red) 3
1
24
7
E3S-A
* Models numbers for Through-beam Sensors (E3S-AT@1) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3S-AT21-L 2M), the model number of the Receiver, by adding "-
D" (example: E3S-AT21-D 2M). Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
Structure of Sensor I/O Connector
E3S-AT21 *
E3S-AT71 *
E3S-AD21
E3S-AD71
E3S-AD22
E3S-AD72
E3S-AD23
E3S-AD73
Light-ON L Side
(LIGHT ON)
Through-beam Receivers, Diffuse-reflective Sensors
Dark-ON D Side
(DARK ON)
--- ---
Through-beam Emitters
E3S-AR21
E3S-AR71
Light-ON L Side
(LIGHT ON)
Retro-reflective Sensors
Dark-ON D Side
(DARK ON)
Model Operation
mode Timing charts
Mode
selector
switch
Output circuit
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between brown and black)
Output
transistor
Load
(e.g., relay)
(Self-diagnostic
output)
Z
D
Z
D
Light
indica-
tor
Stability
indicator
(green)
Photo-
electric
Sensor
main
circuit
Load
(relay)
Brown
Blue
Black
(Control
output)
100 mA max.
10 to
30 VDC
(red)
Load
(relay)
Orange
50 mA max.
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between brown and black)
Output
transistor
Load
(e.g., relay)
External
diagnostic
input
Emitter LED
Indicator
(red)
ON
OFF
ON
OFF
ON
OFF
(Between blue and pink)
0 V
(External
diagnostic input)
Power indicator
(red)
Photo-
electric
Sensor
main
circuit
Brown
Blue
10 to 30 VDC
Pink
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between brown and black)
Output
transistor
Load
(e.g., relay)
12 K
(External
diagnostic input)
(Self-diagnostic
output)
Z
D
Light
indica-
tor
Stability
indicator
(green)
Photo-
electric
Sensor
main
circuit
Load
(relay)
Brown
Blue
Black
(Control
output)
100 mA max.
10 to
30 VDC
(red)
Load
(relay)
Orange
50 mA max.
Z
D
Pink
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between brown and black)
Output
transistor
Load
(e.g., relay)
2
4
1 3
1
2
3
4
Terminal No.
XS2F-D421-DC0-F
Brown
Blue
Black
Note: Pin No. 2 is not used.
Classification Wire color Connection Pin No. Application
For DC
Brown 1 +V
--- 2 ---
Blue 3 0 V
Black 4 Output
E3S-A
8
PNP Output
Model Operation
mode Timing charts
Mode
selector
switch
Output circuit
E3S-AT31 *
E3S-AT36 *
E3S-AT81 *
E3S-AT86 *
E3S-AR31
E3S-AR36
E3S-AR81
E3S-AR86
E3S-AD31
E3S-AD36
E3S-AD81
E3S-AD86
E3S-AD32
E3S-AD37
E3S-AD82
E3S-AD87
E3S-AD33
E3S-AD38
E3S-AD83
E3S-AD88
Light-ON L Side
(LIGHT ON)
Through-beam Receivers, Retro-reflective Sensors, Diffuse-reflective
Sensors
Dark-ON D Side
(DARK ON)
Through-beam Model Emitters
E3S-AT41 *
E3S-AT91 *
E3S-AD41
E3S-AD91
E3S-AD42
E3S-AD92
E3S-AD43
E3S-AD93
Light ON L Side
(LIGHT ON)
Through-beam Receivers, Diffuse-reflective Sensors
Dark ON D Side
(DARK ON)
--- ---
Through-beam Emitters
* Models numbers for Through-beam Sensors (E3S-AT@@) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3S-AT31-L 2M), the model number of the Receiver, by adding "-D"
(example: E3S-AT31-D 2M). Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between blue and black)
Output
transistor
Load
(e.g., relay)
Connector Pin Arrangement
Note: Pin 2 is not used.
1
3
4
Light
indica-
tor
Stability
indicator
Photo-
electric
Sensor
main
circuit
Z
D
Load
Brown
Blue
Black (Control output)
(Relay)
10 to
30 VDC
(red)
(green)
100 mA max.
3
1
24
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between blue and black)
Output
transistor
Load
(e.g., relay)
3
1
Light
indica-
tor Photo-
electric
Sensor
main
circuit
Brown
Blue
10 to
30 VDC
(red)
Connector Pin Arrangement
Note: Pins 2 and 4 are not used.
3
1
24
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between blue and black)
Output
transistor
Load
(e.g., relay)
(Self-diagnostic
output)
Z
D
Z
D
Light
indica-
tor
Stability
indicator
(green)
Photo-
electric
Sensor
main
circuit
Load
(relay)
Brown
Blue
Black
(Control
output)
100 mA max.
10 to
30 VDC
(red)
Load
(relay)
Orange
50 mA max.
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between blue and black)
Output
transistor
Load
(e.g., relay)
External
diagnostic
input
Emitter LED
Indicator
(red)
ON
OFF
ON
OFF
ON
OFF
(Between brown and pink)
0 V
(External
diagnostic input)
Power indicator
(red)
Photo-
electric
Sensor
main
circuit
Brown
Blue
10 to 30 VDC
Pink
9
E3S-A
Structure of Sensor I/O Connector
Adjustment Methods
Sensitivity Adjustment for Diffuse-reflective Sensors Set to Light ON
Unlike conventional Photoelectric Sensors, the variation in the sensitivity of E3S-A Photoelectric Sensors is minimal. This means
the sensitivity can be adjusted on only a single Photoelectric Sensor, and then the adjusters on the other Photoelectric Sensors
can be set to the same scale position. There is no need to adjust the sensitivity of each Photoelectric Sensor individually.
E3S-AR41
E3S-AR91
Light-ON L Side
(LIGHT ON)
Retro-reflective Sensors
Dark-ON D Side
(DARK ON)
Item Sensing condition Sensitivity adjuster Indicators Procedure
1) Position A
Locate a sensing object at the sensing
distance, set the sensitivity adjuster to
the minimum scale position, and
gradually increase sensitivity by turning
the sensitivity adjuster clockwise until the
incident light indicator (red LED) is ON.
Position A is where the indicator has
turned ON.
2) Position B
Position B is when the sensing object is
removed and the sensitivity adjuster is
turned clockwise until the incident light
indicator (red LED) is ON. Position C is
where the adjuster is turned
counterclockwise (reducing the
sensitivity) from position B until the
incident light indicator (red LED) is OFF.
When there are no background objects,
the maximum sensitivity is position C.
3) Setting ---
Set the sensitivity adjuster to halfway
between (A) and (C) (at the optimum
sensitivity). Check that the stability
indicator (green LED) turns ON
according to whether the sensing object
is there or not. There is not sufficient
margin if it does not turn ON. If this is the
case, reconsider the detection method.
Model Operation
mode Timing charts
Mode
selector
switch
Output circuit
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between blue and black)
Output
transistor
Load
(e.g., relay)
4.4 K
(External
diagnostic input)
(Self-diagnostic
output)
ZD
Light
indica-
tor
Stability
indicator
(green)
Photo-
electric
Sensor
main
circuit
Load
(relay)
Brown
Blue
Black
(Control
output)
100 mA max.
10 to
30 VDC
(red)
Load
(relay)
Orange
50 mA
max.
Pink
ZD
T
T: OFF-delay timer (0 to 100 ms)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Light indicator
(red)
(Between brown and black)
Output
transistor
Load
(e.g., relay)
2
4
1 3
1
2
3
4
Terminal No.
XS2F-D421-DC0-F
Brown
Blue
Black
Note: Pin 2 is not used.
Classification Wire color Connection Pin No. Application
For DC
Brown 1 +V
--- 2 ---
Blue 3 0 V
Black 4 Output
Photoelectric
Sensor
Sensing object
Backg-
round
object
Min. Max.
(A)
Stability
indicator
(green)
Light
indicator
(red)
ON OFF OFF ON
Photoelectric
Sensor
Sensing object
Backg-
round
object
Min. Max.
(B)
(C)
ON OFF ON OFF
Stability
indicator
(green)
Light
indicator
(red)
Min. Max.
(C)
(A)
ON ON OFF
Stability
indicator
(green)
Light
indicator
(red)
E3S-A
10
Safety Precautions
This product is not designed or rated for
ensuring safety of persons.
Do not use it for such purposes.
1. Do not use the product in environments subject to
flammable or explosive gases.
2. Do not use the Sensor in environments where the cables
may become immersed in oil or other liquids or where
liquids may penetrate the Sensor.
Doing so may result in damage from burning and fire,
particularly if the liquid is flammable.
3. When disposing of the product, treat it as industrial waste.
Do not use the product in atmospheres or environments that
exceed product ratings.
Do not use the Sensor in water, rainfall, or outdoors.
Mounting
Position of Optical Axis of Through-beam Model
Unlike conventional through-beam sensors, the E3S-A
Through-beam Photoelectric Sensor incorporates 2 lenses.
The lens actually in use is the one marked with an arrow
indicating the position of the optical axis. When using a Slit,
attach it to the lens marked with the arrow.
Tightening the Connector
Manually tighten the connector until the threads have
completely disappeared. If tightening is insufficient, the
degree of protection may not be maintained, or the connector
may become loose when it is subjected to vibration. Using
pliers to tighten the connector may damage it.
Use the E39-L60 Close Mounting Plate (provided) if the
Sensor is mounted using mounting brackets or if it is mounted
directly. (Refer to Dimensions.)
Mounting Bracket (Provided)
The direction of the optical axis coincides with the machine
axis of the E3S-A when the mounting screw is inserted into
the lock hole of the Mounting Bracket. If the mounting surface
and the screw hole are correctly aligned toward the sensing
object (or toward the Retroreflector for a Through-beam
Sensor), the mechanical axis and optical axis will be aligned
when the screw is inserted into the hole. Incident light will be
detected, and time-consuming adjustment will not be
necessary. (If, however, the mounting surface is not flat,
adjustment of the optical axis may still be required.)
Adjust the position of the Sensor so that incident light points
at the center. Make sure that the incident light is at a fixed
position.
The maximum tightening torque of the screw is 0.53 N.m max.
Adjustments
E39-S46 Through-beam Slits
(Accessory, order separately)
Use the rubber attachment with the metal cover if a slit width
of 2 mm is required. (A Slit is not required in this case.) Insert
the 0.5- or 1-mm Slit between the metal cover and rubber
attachment if a slit width of 0.5 or 1 mm is desired.
These Slits fit into the rubber attachment.
Apply the Slit to the lens of the Photoelectric Sensor marked
with an arrow indicating the position of the optical axis (apply
it to the bottom lens of Horizontal Sensors and the top lens of
Vertical Sensors).
WARNING
Precautions for Safe Use
Precautions for Correct Use
Unused lens
Optical axis indicator arrow
Arrow indicating optical axis position
Lens actually in use (attach the Slit to this lens)
Position of Arrow Indicating Optical Axis
Model Position of lens in use
E3S-A
(Vertical Sensors) Top
E3S-A
(Horizontal
Sensors)
Bottom
Screw
Optical axis
Machine axis
Base of mounting
bracket
Bracket can move
in this direction
Optical axis lock hole (M3)
Arrow indicating
position of optical axis
2 mm
13.6 mm
11.1 mm
Metal cover
Slit (0.5 mm or 1 mm)
Rubber attachment
Indented portions
E3S-A
11
E3S-A
E39-E6 Polarized Mutual Interference Prevention Filters
for Through-beam Sensors
(Accessory, order separately)
A set of 4 Filters are sold together for two Through-beam
Sensors (for 2 each for Emitters and Receivers). Order one
for every two sets of Photoelectric Sensors.
For mounting, refer to the figure of the Through-beam Slits.
The arrow printed on the cover indicates the direction of
polarization. By attaching the Filters opposite to each other
in polarization to the Emitters and the Receivers in rows,
mutual interference can be prevented (in any case, the
Filter attached to an Emitter and to the corresponding
Receiver must be the same in direction of polarization or the
Photoelectric Sensor will not function).
Operating Mode Selection
As shown in the following illustration, the E3S-A has an
operating mode selector on the panel where the Receiver
connector is located.
With this operating mode selector, the E3S-A is in either Dark-
ON or Light-ON mode.
and Switch
The Emitter of the Through-beam Sensor with the self-
diagnostic feature incorporates a turbo switch. When this
switch is ON, the intensity of the red LED light source can be
increased to make a brighter spot.
Function ( Switch)
The turbo function is effective with the turbo switch pressed,
and the function is reset automatically when released.
With the turbo function switched ON, the light spot is visible
even at a distance of 200 mm, making it easy to check the
sensing position and the angle of the optical axis.
Precautions
(1)Do not keep the turbo switch pressed for longer than 3
minutes. (It will not break even if it is pressed for an
extended period.)
(2)Pressing the switch may change the timer delay settings.
Set the timer after using the turbo function to check the
optical axis.
(3)To press the switch, use a force of 9.8 N max.
Using the E39-R5 Optical Axis Reflector for Through-
beam Sensors
(Accessory, order Separately)
Use this attachment when the set distance is long and
adjustment is mechanically difficult with a sensing object.
Attach the Reflector to the Receiver.
Look at the Reflector from right behind the Emitter. The
Reflector should be bright with red light when the optical
beam strikes the Reflector. If the Emitter has a turbo
function, the Reflector looks brighter with the function
switched ON.
When the Reflector is removed, the light beam strikes the
Receiver.
Emitter
Receiver
Up to two units
can be attached.
Y = 0
Note: The arrows on the Filters can be attached in
either direction when two Sensors are
mounted next to each other. The Filter
attached to an Emitter and to the
corresponding Receiver must be the same
in direction of polarization or the Sensor will
not function.
Light ON
(ON when light is ON)
Operating mode switch (black)
Dark ON
(ON when light is OFF)
DL
The default operating mode is shown in the
following table.
Sensing method Default switch
setting
Through-beam Sensors
Retro-reflective Sensors Dark-ON
Diffuse-reflective Sensors Light-ON
Timer
Turbo
Turbo
Turbo
Sensitivity adjuster
The OFF-delay timer adjuster is
used as a turbo switch (black).
The intensity of the
red spot will be
increased, making
visual confirmation
much easier.
PUSH
Eye
E3S-AT@@
Emitter
E3S-AT@@
Receiver
E39-R5
Optical Axis Confirmation Reflecto
r
E3S-A
12
Dimensions
E3S-A Built-in Amplifier Photoelectric Sensor
Note: Models numbers for Through-beam Sensors (E3S-AT@1) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3S-AT11-L 2M), the model number of the Receiver, by adding "-D"
(example: E3S-AT11-D 2M). Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
Through-beam Sensors (Horizontal)
Pre-wired Sensors
(Unit: mm)
Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet.
3.1
Stainless steel
(SUS304)
7.2
5
20
30
10.5
7.2
16.9
28.9
29.2
5.5
1.2
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
10.7
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AT11/21/31/41 (Receiver)
Emitter: E3S-AT@@-L
Receiver: E3S-AT@@-D
*1. Not applicable to Sensors with timer adjusters (E3S-AT11 and E3S-AT31).
*2. The E3S-AT11 or E3S-AT31 has three conductors.
Lens (7 × 7) Optical axis
Two, M3 × 12 screws
1.3
10.5 20
8
21
40
12.9
75.5
(4)
8.8 dia.
12
12.4
Sensitivity adjuster (white)
Light indicator
(red)
Stability indicator (green)
Timer adjuster (black) *1
Operation mode
selector switch
Two, M3 holes
20
4-dia. vinyl-insulated
round cable with
4 conductors
(Conductor cross
section: 0.2 mm2,
Insulator diameter:
1.1 mm),
Standard length: 2 m *2
Mounting Holes
E3S-AT11/31 (Emitter)
29.2
5.5
1.2 10.7
3.1 7.2
5
20
30
10.5
7.2
16.9
28.9
Stainless steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
3.1 7.2
5
20
30
10.5
7.2
16.9
28.9
Optical
axis
E3S-AT21/41(Emitter)
1.3
10.5 20
8
21
Power indicator (red)
40
17.8
(4)
12
12.4
40
12.9 12.5
(4)
8.8 dia.
12
10.5 20
12.4
Turbo switch
20
Lens (7 × 7) Optical axis
Two, M3 × 12 screws
Two, M3 holes
4-dia. vinyl-insulated
round cable with
2 conductors
(Conductor cross
section: 0.2 mm2,
Insulator diameter:
1.1 mm),
Standard length: 2 m
Power indicator (red)
4-dia. vinyl-insulated round
cable with 3 conductors
(Conductor cross section:
0.2 mm2,
Insulator diameter: 1.1 mm),
Standard length: 2 m
8.8 dia.
Mounting Holes
13
E3S-A
Note: Models numbers for Through-beam Sensors (E3S-AT@6) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3S-AT16-L), the model number of the Receiver, by adding "-D"
(example: E3S-AT16-D). Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
Sensors with Standard Connectors
29.2
5.5
1.2 10.7
3.1 7.2
5
7.2
16.9
28.9
20
35.5
10.5 Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AT16/36 (Receiver)
1.3
10.5 20
8
21
40
12.9 7
(10)
12
12.4
20
Lens (7 × 7) Optical axis
Two, M3 × 12 screws
Sensitivity adjuster (white)
Light indicator
(red)
Stability indicator (green)
Operation mode
selector switch
Two, M3
M12 Connector
Mounting Holes
29.2
5.5
1.2 10.7
3.1 7.2
5
20
35.5
10.5 7.2
16.9
28.9
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AT16/36 (Emitter)
40
17.8
(10)
12
12.4
1.3
10.5 20
8
21
20
Two, M3 × 12 screws
Lens (7 × 7) Optical axis
Power indicator (red)
Two, M3
M12 Connector
Mounting Holes
E3S-A
14
Note: Models numbers for Through-beam Sensors (E3S-AT@1) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3S-AT61-L 2M), the model number of the Receiver, by adding "-D"
(example: E3S-AT61-D 2M). Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
Through-beam Sensors (Vertical)
Pre-wired Sensors
3.1
20
20
47.2
5.5 5.4 7.2
16.9
28.9
8.3
10.5 20
29.2
1.2 10.7
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 x 12 screws
With Mounting Bracket Attached
E3S-AT61/71/81/91 (Receiver)
40
1.3
*1. The E3S-AT61 or E3S-AT81 has three conductors.
*2. Not applicable to timer adjuster models E3S-AT61 and E3S-AT81.
5.5
7
3.6
Timer adjuster
(black) *2
21
Sensitivity
adjuster (white)
13.5
(4)
10.5 20
12
12.4
20
Two, M3 × 12 screws
8.8 dia.
Operation mode
selector switch
Two, M3 holes
4-dia. vinyl-insulated
round cable with
4 conductors
(Conductor cross
section: 0.2 mm2,
Insulator diameter:
1.1 mm),
Standard length: 2 m
*1
Lens (7 × 7) Optical axis
Light indicator (red)
Stability indicator
(green)
Mounting Holes
29.2
1.2 10.7
3.1
20
47.2
5.5 5.4 7.2
16.9
28.9
10.5 20
20
8.3
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AT61/81 (Emitter)
E3S-AT71/91 (Emitter)
29.2
1.2 10.7
*The Mounting Bracket can be attached to side A.
A*
Two, M3 × 12 screws
Two, M3 holes
4-dia. vinyl-insulated
round cable
with 2 conductors
(Conductor cross
section: 0.2 mm2,
Insulator diameter:
1.1 mm),
Standard length: 2 m *
Lens (7 × 7) Optical axis
Power indicator (red)
Power indicator (red)
Mounting Holes
8.5
21
*The E3S-AT71 of E3S-AT91
has three conductors.
1.3
10.5 20
12.5
3.6 Turbo switch
21
40
13.5
(4)
8.8 dia.
12
12.4
20
15
E3S-A
Note: Models numbers for Through-beam Sensors (E3S-AT@6) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is expressed by adding "-L" to the set model number (example: E3S-AT66-L), the model number of the Receiver, by adding "-D"
(example: E3S-AT66-D). Refer to Ordering Information to confirm model numbers for Emitter and Receivers.
Connector Sensors
3.1
20
41.7
5.4
7.2
19.4
31.4
Use these
two holes
for
mounting.
29.2
1.2 10.7
10.5 20
8.3
Stainless steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
E39-L60 Close Mounting Plate (provided)
(Attach the mounting plate or the
plug cannot be connected.)
With Mounting Bracket Attached
E3S-AT66/86 (Receiver)
M12
Connector
40
13.5
(10)
12
1.3
10.5 20
Operation
mode
selector
switch
7
3.6
21
Two, M3 holes
20
Two, M3 × 12 screws
Lens (7 × 7) Optical axis
LIght indicator (red)
Stability
indicator
(green)
Sensitivity
adjuster
(white)
Mounting Holes
29.2
1.2 10.7
10.5 20
3.1
20
41.7
5.4
7.2
19.4
31.4
8.3
Use these
two holes
for
mounting.
Stainless steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
E39-L60 Close Mounting Plate (provided)
(Attach the mounting plate or the
plug cannot be connected.)
With Mounting Bracket Attached
E3S-AT66/86 (Emitter)
40
13.5
(10)
12
1.3
10.5 20
8.5
21
20
M12 Connector
Two, M3 × 12 screws
Two, M3 holes
Lens (7 × 7) Optical axis
Power indicator (red)
Mounting Holes
E3S-A
16
Retro-reflective Sensors (Horizontal)
Pre-wired Sensors
Sensors with Connectors
929.2
1.2 10.7
3.1 7.2
5
20
30
10.5
7.2
16.9
28.9
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AR11/21/31/41
42.3
15.2
2.3
75.5
(4) *2
12
12.4
11.5
Emitter
Receiver
8.8 dia.
21
1.3
12.820
20
*1. For E3S-AR21 and E3S-AR41 only.
*2. 9.7 mm for E3S-AR21 and E3S-AR41.
*3. The E3S-AR11 or E3S-AR31 has three conductors.
Lens (7 × 14)
Optical
axis
Two, M3 × 12 screws
Stability indicator (green)
Light indicator (red)
Operation mode
selector switch
Two, M3 holes
4-dia. vinyl-insulated
round cable
with 5 conductors
(Conductor cross
section: 0.2 mm2,
Insulator diameter:
1.1 mm),
Standard length:
2 m *3
Sensitivity adjuster (white)
Timer adjuster/
Turbo switch (black) *1
Turn to adjust the timer:
push to switch turbo function
Mounting Holes
929.2
1.2 10.7
3.1 7.2
55.5
20
30
7.2
16.9
28.9
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AR16/36
Connector M12
42.3 (10)
15.2
2.3
7
12
12.4
1.3
12.820
11.5
21
20
Emitter
Receiver
Lens (7 × 14)
Optical
axis
Two, M3 × 12 screws
Stability indicator (green)
Light indicator (red)
Operation
mode
selector switch
Two, M3 holes
Sensitivity adjuster (white)
Mounting Holes
17
E3S-A
Retro-reflective Sensors (Vertical)
Pre-wired Sensors
Sensors with Connectors
10.5 20
31.5
1.2 10.7
3.1
20
20
47.2
5.5 5.4 7.2
16.9
28.9
4.8
With Mounting Bracket Attached
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
E3S-AR61/71/81/91
40
17
(4) *2
8.8 dia.
12
12.4
1.3
10.5 20
5.5
7
5.9
23.3
20
Emitter
Receiver
*1. Available on E3S-AR71 and E3S-AR91 only.
*2. 9.7 mm for E3S-AR71 and E3S-AR91.
*3. The E3S-AR611 or E3S-AR81 has three conductors.
Lens (5.7 × 10.9)
Optical axis
Two, M3 × 12 screws
Stability indicator
(green)
Light indicator
(red)
Operation mode
selector switch
Two, M3 holes
4-dia. vinyl-insulated
round cable
with 5 conductors
(Conductor cross
section: 0.2 mm2,
Insulator diameter:
1.1 mm),
Standard length:
2 m *3
Sensitivity
adjuster
(white)
Timer adjuster/
Turbo switch (black) *1
Turn to adjust the timer:
push to switch turbo function
Mounting Holes
Four
mounting
holes
10.5 20
31.5
1.2 10.7
3.1
20
41.7
5.4
7.2
19.4
31.4
4.8
Use these
two holes
for
mounting.
Stainless steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
E39-L60 Close Mounting Plate (provided)
(Attach the mounting plate or the
plug cannot be connected.)
With Mounting Bracket Attached
E3S-AR66/86
M12
Connector
40
17
(10)
12
1.3
10.5 20
7
5.9
23.3
Stability indicator
(green)
20
Mounting Holes
Emitter
Receiver
Lens (5.7 × 10.9)
Optical axis
Two,
M3 × 12 screws
Light indicator (red)
Operation
mode
selector switch
Two, M3 holes
Sensitivity
adjuster
(white)
E3S-A
18
Diffuse-reflective Sensors (Horizontal)
Pre-wired Sensors
Sensors with Connectors
29.2
9
1.2 10.7
3.1 7.2
5
20
30
10.5
7.2
16.9
28.9
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AD11/12/13/21/22/23
-AD31/32/33/41/42/43
1.3
10.5 20
11.5
21
40
12.9 7 5.5
(4)
8.8 dia.
12
12.4
20
Emitter
Receiver
*1. Timer adjuster: Not available on E3S-AD11, E3S-AD12, E3S-AD13, E3S-AD31,
E3S-AD32 and E3S-AD33.
Turbo switch: Available on E3S-AD21 and E3S-AD41 only.
*2. The E3S-AD11, E3S-AD12, E3S-AD13, E3S-AD31, E3S-AD32, or E3S-AD33 has three conductors.
Lens (7 × 14)
Optical
axis
Two, M3 × 12 screws
Stability indicator (green)
Light indicator (red)
Operation mode
selector switch
Two, M3 holes
4-dia. vinyl-insulated
round cable
with 4 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm),
Standard length: 2 m *2
Sensitivity adjuster (white)
Timer adjuster/
Turbo switch (black) *1
Turn to adjust the timer:
push to switch turbo function
Mounting Holes
5.5
29.2
9
1.2 10.7
3.1 7.2
5
20
30
7.2
16.9
28.9
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AD16/17/18/36/37/38
11.5
21
10.5 20
40
12.9 7
(10)
12
12.4
20
1.3
Emitter
Receiver
Lens (7 × 14)
Two, M3 × 12 screws
Stability indicator (green)
Light indicator (red)
Operation mode
selector switch
Two, M3 holes
Sensitivity adjuster (white)
Optical
axis
M12 Connector
Mounting Holes
19
E3S-A
Diffuse-reflective Sensors (Vertical)
Pre-wired Sensors
Sensors with Connectors
29.2
1.2 10.7
10.5 20
3.1
20
20
47.2
5.5 5.4 7.2
16.9
28.9
4.8
Stainless
steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
With Mounting Bracket Attached
E3S-AD61/62/63/71/72/73
-AD81/82/83/91/92/93
5.5
7
3.6
21
1.3
10.5 20
40
17
(4)
8.8 dia.
12
12.4
20
Emitter
Receiver
*1. E3S-AD61, E3S-AD62, E3S-AD63, E3S-AD81, E3S-AD82, and E3S-AD83 have
three conductors.
*2. Timer adjuster: Not available on E3S-AD61, E3S-AD62, E3S-AD63, E3S-AD81,
E3S-AD82 and E3S-AD83.
Turbo switch: Available on E3S-AD71 and E3S-AD91 only.
Lens (7 × 14)
Optical axis
Two, M3 × 12 screws
Stability indicator
(green)
Light indicator (red)
Operation mode
selector
Two, M3 holes
4-dia. vinyl-insulated
round cable
with 4 conductors
(Conductor cross
section: 0.2 mm2,
Insulator diameter:
1.1 mm),
Standard length:
2 m *1
Sensitivity
adjuster
(white)
Timer adjuster/
Turbo switch (black) *2
Turn to adjust the timer:
push to switch turbo function
Mounting Holes
E3S-AD66/67/68/86/87/88
29.2
1.2 10.7
10.5 20
3.1
20
41.7
5.4
7.2
19.4
31.4
4.8
Use these
two holes
for
mounting.
Stainless steel
(SUS304)
*The Mounting Bracket can be attached to side A.
Optical axis
Optical
axis
A*
Two, M3 × 12 screws
E39-L60 Close Mounting Plate (provided)
(Attach the mounting plate or the
plug cannot be connected.)
With Mounting Bracket Attached
7
3.6
21
1.3
10.5 20
40
17
(10)
12
20
Receiver
Lens (7 × 14)
Optical axis
Two, M3 × 12 screws
Stability indicator
(green)
Light indicator (red)
Operation
mode
selector switch
Two, M3 holes
Sensitivity
adjuster
(white)
Emitter
Connector
M12
Mounting Holes
E3S-A
20
Accessories (Order Separately)
Reflectors
Mounting Brackets
Insert-type Long Slit (For Through-beam Model)
E39-S46
Name Dimensions A Material Quantity
Supporter 2 mm Stainless steel
(SUS304)
One each for Emitter and
Receiver (total of 2)
Slits 0.5 mm PVC One each for Emitter and
Receiver (total of 4)
1 mm
A
A
21.4 13.6
9.7
11.6 6.8
2.1
A
2.1
21.4
11.6 6.8
*
Filters for Mutual Interference Prevention
(For Through-beam Model)
E39-E6
Material: Stainless steel (SUS304)
* Two of each for the Emitter and
Receiver (total of four)
25
59.9
7.5
40.9
11.2
15.9
11.7
9.7
7.9 11.6
Bracket to be attached
to the Emitter panel of
E3S-A
Material:
Reflector: Acryl
Back: ABS
Optical Axis Confirmation Reflector
(For Through-beam Model)
E39-R5
In the interest of product improvement, specifications are subject to change without notice.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016
.
10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/