XT IEC Power Control Product Guide * XT Contactors & Overload relays * XT Manual Motor Protectors * XT Manual Motor Controllers Global products mean global solutions Eaton's Electrical operations As a market-leading manufacturer of circuit protection and control equipment, Eaton's world leading switch and fuse-gear, circuit breakers, motor control gear and wiring accessory products are distributed across the globe. Incorporating the latest technological advances, Eaton products are the result of a comprehensive ongoing development programme and comply with the industry's most rigorous quality standards. This all serves to make Eaton an industry benchmark, with unsurpassed quality and performance guaranteed. This extensive product range, together with a lengthy experience and specialist knowledge serves to make Eaton your first source solutions provider. Find out more on www.eatonelectrical.com Services Portfolio Extensive support services Our service strategy includes an extensive selection of technical and commercial services designed to help you specify, order and receive products quickly and efficiently. World-Class Support At Eaton, our goal is to deliver world-class support as well as products. This is why we continue to invest in our customer service capability to ensure you have easy access to the services you need, when you need them. Integrated service strategy Our integrated service strategy is based upon linking key locations and personnel along with a complete range of services to provide you "one-call" customer service. A central support number allows you to access these support services by selecting the product group and service required. We then ensure it is quickly routed to a qualified support agent. The result is service that delivers you solutions ... fast. A single point of contact for all your enquiries is just one of the benefits you can look forward to as an Eaton customer. Price & Availability Project Co-Ordination * Prompt Product Pricing * Up-to-date stock availability * Order tracking for Systems based orders * On-site Project Management service * Tailored Delivery service Order & Shipment status * Order Checking and Status * Shipment details Technical Support * "Over the phone" resolution * Technical data assistance * Selection and crossreference After Sales Support * Debit/Credit note resolution * Policy Returns support Engineered Site Services * Installation and Commissioning * Maintenance and Service Solution support * 24 hour "call out" emergency service Distributor Product Training * Individual or Group Product training forums * Use of "In house" training facilities How to use this Product Guide Two steps to find your product STEP 1 Choose main group STEP 2 Choose list number Indexes Search by product name or list number. Product type index Eaton list number index Legend Function of coloured text bars: Products Accessories Technical data, drawings & specifications PG03407001U - June 2006 How to use this Product Guide 1 Product Guide index 2 Product Guide index PG03407001U - June 2006 General characteristics, Products * The feature-packed line of Relays, Timers and Miniature Controls . . . . .4 * The feature-packed line of Contactors, Overload Relays and Starters . . .6 * The feature-packed line of Manual Motor Protectors . . . . . . . . . . . . . . . .7 * The feature-packed line of Manual Motor Controllers . . . . . . . . . . . . . . .8 Relays and Timers * Miniature and Standard Control Relays . . . . . . . . . . . . . . . . . . . . . . . . . .9 * Front Mount Auxiliary Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 * Miniature Electronic On-delay and Multi-function Timers . . . . . . . . . . .12 * Electronic Star Delta Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 3 Miniature Controls * Miniature Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 * Front Mount Auxiliary Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 * Accessories, Miniature Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 * Miniature Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 4 Contactors and Overload Relays * 3-pole and 4-pole Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 * Front-Mount Auxiliary Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 * Accessories, Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 * Overload Relays and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Starters * Starters, Direct-on-line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 * Reversing Starters, Direct-on-line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 * Starters, Star Delta . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 * Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 6 Manual Motor Protectors * Manual Motor Protectors, Pushbutton . . . . . . . . . . . . . . . . . . . . . . . . . .51 * Manual Motor Protectors, Rotary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 * Manual Motor Protectors, Auxiliary Contacts . . . . . . . . . . . . . . . . . . . . .56 * Accessories, Manual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . .58 7 Manual Motor Controllers * Manual Motor Controllers, Direct-on-line . . . . . . . . . . . . . . . . . . . . . . . .64 * Manual Motor Controllers, Accessories . . . . . . . . . . . . . . . . . . . . . . . . .66 * Manual Motor Controllers, Direct-on-line Reversing . . . . . . . . . . . . . . .67 8 Technical data * Technical Details Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 Index * Eaton list number index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167 1 2 5 PG03407001U - June 2006 Product Guide index 3 1 General characteristics, Products This chapter describes general characteristics of Eaton's technologically advanced range of Relays and Timers, Miniature Controls, Contactors , Overload Relays, Starters Manual Motor Protectors and Manual Motor Controllers. Because XT meets IEC, UL, CSA, and CCC standards, it is the perfect product solution for applications all over the world. G ener al char act er i st i cs, Pr oduct s The feature packed line of Relays and Timers Eaton's new line of XT Relays and Timers includes miniature and standard frame control relays and auxiliary contacts, miniature electronic on-delay and multi-function timers and an electronic star-delta timer for use in star-delta combinations. Technical characteristics * For use with Miniature and Standard frame size contactors and starters * Control Relays * AC Control from 12V to 550V 50 Hz, 600V 60 Hz * DC Control from 12V to 220V * On-Delay and Multi-FunctionTimers * 24 - 240V AC/DC Control * Available with screw or spring cage terminals * 4-Pole Configurations * IP20 finger and back-of-hand proof *Large ambient temperature range - 25 to 50C Standards * IEC EN 60947 * CE Marked * UL * CSA * CCC (pending) * ATEX (pending) 4 General characteristics, Products PG03407001U - June 2006 The Feature Packed line of Miniature Controls Due to its compact size, the XT line of miniature controls is best suited to be applied in light duty loads such as hoisting, packaging, material handling, heating, lighting and automation systems. XT miniature contactors are a particularly compact, economic and environmentally friendly solution wherever control of small motors or loads is required. Technical characteristics Miniature Contactors -- Types XTMC and XTMF, 6 - 9A * AC Control from 12V to 550V 50 Hz, 600V 60 Hz * DC Control from 12V to 220V * Reversing or Non-reversing * 3 and 4-Pole Configurations * 3-Pole XTMC * 4-Pole XTMF * Panel or DIN rail mounting * IP20 finger and back-of-hand proof * Low noise operation * High degree of climatic proofing * Large ambient temperature range -25 to 50C Miniature Overload Relays -- Bimetallic Type XTOM * Phase failure sensitivity * Direct mount to XTMC and XTMF Miniature Contactors * Trip Class 10 * 11 settings to cover 0.1 to 12A * Ambient temperature compensated -5 to 50C * Manual and automatic reset by selector switch * 1 Make (NO) or 1 Break (NC) auxiliary contact as standard * Test/Off Button G ener al char act er i st i cs, Pr oduct s * Available with screw or spring cage terminals * Trip-free release Standards and Certifications * IEC EN 60947 * CE Marked * UL * CSA * ATEX (pending) * CCC (pending) PG03407001U - June 2006 General characteristics, Products 5 The Feature Packed line of Contactors, Overload Relays and Starters Eaton's new line of XT Contactors and Starters includes non-reversing and reversing contactors, overload relays and a variety of related accessories. Because XT meets IEC, UL, CSA, CCC and ATEX standards, it is the perfect product solution for applications all over the world. The compact, space saving, and easy to install XT line of IEC contactors and starters is the efficient and effective solution for customer applications from 7A to 2000A. Technical Characteristics * AC control from 12V to 600V 50/60 Hz * DC control from 12V to 220V G ener al char act er i st i cs, Pr oduct s * Available with screw or spring cage terminals * Reversing or non-reversing contactors and starters * AC-3 contactor ratings to 1000A and AC-1 contactor ratings to 2000A * Non-reversing starters to 650A * Panel or DIN rail mounting to 65A * IP20 finger and back-of-hand proof * Large ambient temperature range, -25 to 50C * AC and DC controlled contactors in the same compact frame * Low power consumption DC coils * Built-in NO or NC auxiliary contacts to 32A * Plug-in accessories for reduced installation time Standards and Certifications * IEC EN 60947 * CE Marked * UL * CSA * CCC * ATEX 6 General characteristics, Products PG03407001U - June 2006 The Feature Packed line of Manual Motor Protectors Eaton's new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class 10 adjustable bimetallic overload relay and fixed magnetic short circuit trip capability in one compact unit. Two frame sizes are available: Frame B (45 mm) for motors with FLC ratings up to 32A and Frame D (55 mm) covers motor FLC ratings up to 63A. Technical Characteristics * ON/OFF Rotary Handle with Lockout Provision * Visible Trip Indication * Phase Loss Sensitivity * Ambient Temperature Compensation to IEC/EN 60947, VDE 0660 * Fixed Short Circuit Trip -- 14 times maximum setting of overload FLC dial * Type 2 Coordination per IEC 947 * Identification Markers Standard on Starter Faceplate * Motor Applications from 0.1A to 63A * Built-in heater and magnetic trip elements to protect the motor * Adjustment dial for setting motor FLC * DIN Rail Mount * Terminal Types Available: - Screw terminals - Screw (line) and Spring Cage (load) terminals - Spring Cage terminals * Accessories include: - Front and Side Auxiliary Contacts - Trip Indicating Contacts - Tamperproof Cover for OLR Dial - Undervoltage Release - Shunt Trip - Thru-the-Door Operators - Enclosures - 3-Phase Line Side Connecting Links G ener al char act er i st i cs, Pr oduct s * Class 10 Overload Protection Standards and Certifications * IEC/EN 60947 * DIN VDE 0660 Part 100, Part 101 and Part 102 * UL Listed * UL 508 Group Motor and Type E Compliant * CSA File LR12530, Class 3211-05 Types (Configurations) * Motor Protective Device with Thermal and Magnetic Trip - XTPB Pushbutton Actuated Manual Motor Protector up to 25A - XTPR Rotary Actuated Manual Motor Protector up to 63A * For the Protection of Transformers with a high inrush current: - XTPT Manual Transformer Protector up to 25A * Motor Protective Device without Overload Function: - XTPM Motor Protective Circuit Breaker up to 32A -- not UL Approved PG03407001U - June 2006 General characteristics, Products 7 The feature packed line of Eaton Manual Motor Controllers The new XT IEC Open Non-reversing and Reversing Manual Motor Controllers combine a Manual Motor Protector with Contactors to provide a complete motor protection solution by combining motor disconnect function, thermal overload protection, magnetic short circuit protection and remote control operation in one compact, assembled unit. These assembled Manual Motor Controllers cover motors with FLC ratings from 0.10A to 52A. Manual Motor Controllers XTSC and XTSR G ener al char act er i st i cs, Pr oduct s * Manual Motor Controller for Single and Multi Motor Panels. The pre-assembled XT Manual Motor Controllers (MMC) combine a Manual Motor Protector, a Wiring Connector Link (WCL) and Contactor. MMCs can also be field installed with separate MMP, WCL and Contactor(s). An IEC magnetic contactor has been added to allow for remote operation of the motor circuit. Features * ON/OFF rotary handle with lockout provision * Visible trip indication * Test trip function * Motor applications from 0.11A to 50A * Class 10 overload protection * Built-in heater and magnetic trip elements to protect the motor * Phase loss sensitivity * Type 2 coordination * Ambient compensated up to 55C * Control inputs located at front of starter for easy access and wiring * Wide range of coils * DIN Rail mount -- XTSC...BB_ * Mounting plates -- XTSC...BC_, XTSC...D motor controllers * Adjustment dial for setting motor FLC * Short circuit trip at 14 times the maximum setting of the FLC adjustment dial * 1NO-1NC Auxiliary Contact as standard on Manual Motor Protector Standards and Certifications * IEC Type 2 Approved per IEC 60947-4-1 * CE Marked * UL 508 Type F Manual Motor Controller * UL Listed File No. E218618 8 General characteristics, Products PG03407001U - June 2006 2 Relays and Timers Miniature and Standard Control Relays This chapter provides product selection guidance for Eaton's XT range of relays and timers which includes miniature and standard frame control relays and auxiliary contacts, miniature electronic on-delay and multi-function timers and an electronic star-delta timer. Standards * IEC EN 60947 * CE Marked * UL * CSA * ATEX See page 10 for coil suffix. See page 10 for accessories. See page 78 for dimensional drawings See page 81 for the technical details. Miniature Control Relays Conventional Thermal Current I th (A) XTRM10A22A Contact Configuration Rated Operational Current I e AC-15 Amps 220/230/240V 380/400/415V 10 4NO 6 3 10 3NO-1NC 6 3 10 2NO-2NC 6 3 Circuit Symbol A1 13 23 33 43 Terminals Screw Spring Cage Eaton list number 1) Eaton list number 1) XTRM10A40_ XTRMC10A40_ XTRM10A31_ XTRMC10A31_ XTRM10A22_ XTRMC10A22_ R elays and Ti m er s * CCC A2 14 24 34 44 A1 13 21 33 43 A2 14 22 34 44 A1 13 21 31 43 A2 14 22 32 44 1) Underscore (_) indicates coil suffix required. Standard Control Relays Conventional Thermal Current I th (A) XTRE10B22A Contact Configuration Rated Operational Current I e AC-15 Amps 220/230/240V 380/400/415V Circuit Symbol 10 4NO 6 4 A1 13 23 33 43 10 3NO-1NC 6 4 A1 13 21 33 43 10 2NO-2NC 6 4 Terminals Screw Spring Cage Eaton list number 1) Eaton list number 1) XTRE10B40_ XTREC10B40_ XTRE10B31_ XTREC10B31_ XTRE10B22_ XTREC10B22_ A2 14 24 34 44 A2 14 22 34 44 A1 13 21 31 43 A2 14 22 32 44 1) Underscore (_) indicates coil suffix required. PG03407001U - June 2006 Relays and Timers 9 Coil Suffix Suffix Code1) Coil Voltage 50Hz 60Hz 110V 220V 230V 24V 415V 550V 120V 240V A B F T C D E G H L N P R U W Y AD 2) BD 2) RD 2) TD 2) WD 2) 24V 480V 600V 208V 220V 277V 440V 190V 240V 380V 400V 380V 12V 12V 24V 42V 48V R elays and Ti m er s DC 48V 120V 220V 12V 24V 48V 1) Add suffix in place of underscore (_) to Eaton List Number 2) With DC Operation: Integrated diode-resistor combination, coil consumption 2.6 kW. Front Mount Auxiliary Contacts for use with XTRM Miniature Control Relays Conventional Free Air Thermal current, I th = I e , AC-1 in Amps Poles Contact Configuration 10 2 2NC 10 2 1NO-1NC 10 2 2NO-0NC 10 2 1NO-1NC 10 4 4NC 10 4 1NO-3NC 10 4 2NO-2NC 10 4 3NO-1NC 10 4 4NO-0NC 10 4 2NO-2NC Contact Symbol QPC 51 61 Terminals Screw Spring Cage Eaton list number Eaton list number 5 XTMCXFA02 -- 5 XTMCXFA11 XTMCXFAC11 5 XTMCXFA20 -- 5 XTMCXFAL111) -- 5 XTMCXFA04 XTMCXFAC04 5 XTMCXFA13 XTMCXFAC13 5 XTMCXFA22 XTMXCFAC22 5 XTMCXFA31 XTMCXFAC31 5 XTMCXFA40 XTMCXFAC40 5 XTMCXFAL221) XTMCXFCLC221) XTMCXFA02 52 62 53 61 54 62 53 63 54 64 57 65 58 66 51 61 71 81 52 62 72 82 53 61 71 81 54 62 72 82 53 61 71 83 54 62 72 84 53 61 73 83 54 62 74 84 53 63 73 83 54 64 74 84 1) 10 Relays and Timers 57 65 71 83 58 66 72 84 1 early-make contact, 1 late-break contact. PG03407001U - June 2006 Front Mount Auxiliary Contacts for use with XTRE Control Relays XTCEXFAC02 Conventional Free Air Thermal Current I th = I e , AC-1 in Amps Poles 16 2 2NO 16 2 1NO-1NC 16 2 2NC 16 2 1NO-1NC 16 4 4NO 53 6373 83 16 4 3NO-1NC 53 61 73 83 16 4 2NO-2NC 16 4 1NO-3NC 16 4 4NC 51 61 71 81 16 4 2NO-2NC 5765 71 83 Contact Configuration Circuit Symbol 53 63 QPC Terminals Screw Spring Cage Eaton list Number Eaton list number 5 XTCEXFAC20 XTCEXFACC20 5 XTCEXFAC11 XTCEXFACC11 5 XTCEXFAC02 XTCEXFACC02 5 XTCEXFALC111) XTCEXFALCC11 1) 5 XTCEXFAC40 XTCEXFACC40 5 XTCEXFAC31 XTCEXFACC31 5 XTCEXFAC22 XTCEXFACC22 5 XTCEXFAC13 XTCEXFACC13 5 XTCEXFAC04 XTCEXFACC04 5 XTCEXFCLC22 1) XTCEXFCLCC22 1) 54 64 53 61 54 62 51 61 52 62 57 65 54 6474 84 54 62 74 84 5361 71 83 54 62 72 84 536171 81 54 62 72 82 R elays and Ti m er s 58 66 52 62 72 82 58 66 72 84 1) 1 early-make contact, 1 late-break contact. Electronic Timer Modules * Front (Top) mounted timer modules for use with XTRE10B_ control relays. Cannot be combined with top mount auxillary contacts, XTCEXF_C_ Voltage Timing Range For use with QPC Eaton list number 0.05 s - 1s 0.5s - 10s 5s - 100s XTRE10B_ 1 XTCEXTEEC11T XTCEXTEEC11T XTCEXTEEC11T 0.05 s - 1s XTRE10B_ 1 0.5s - 10s XTRE10B_ 1 5s - 100s XTRE10B_ 1 XTCEXTED1C11T XTCEXTED1C11A XTCEXTED1C11B XTCEXTED10C11T XTCEXTED10C11A XTCEXTED10C11B XTCEXTED100C11T XTCEXTED100C11A XTCEXTED100C11B 1s - 30s XTRE10B_ 1 XTCEXTEYC20T XTCEXTEYC20A XTCEXTEYC20B Transparent sealable shroud XTCEXTEE used to protect electronic XTCEXTED timer modules from unwanted XTCEXTEY access. 1 XTCEXTESHRD On-Delayed 24V AC/DC 100 - 130V AC 200 - 240V AC Off-Delayed 24V AC/DC 100 - 130V AC 200 - 240V AC 24V AC/DC 100 - 130V AC 200 - 240V AC 24V AC/DC 100 - 130V AC 200 - 240V AC Star-Delta 24V AC/DC 100 - 130V AC 200 - 240V AC Sealable Shroud PG03407001U - June 2006 Relays and Timers 11 Miniature Electronic On-Delay Timers * Fixed on Delay Actuating Voltage Conventional Rated Operational Current Thermal I e AC-11 Amps 220/230/240V 380/400/440V Current I e (A) Time Range Selection Selectable Circuit Symbol Function Eaton list number 1.5 - 30 sec .05 - 1 sec 0.15 - 3 sec 0.5 - 10 sec 3 - 60 sec 0.15 - 3 min 0.5 - 10 min 3 - 60 min 0.15 - 3 h 0.5 - 10 h 3 - 60 h Fixed, On-delay XTMT6A30S11B XTMT6A30S11B 24-240V 50/60Hz 6 24-240V DC 3 R elays and Ti m er s 24-240V 50/60Hz 6 24-240V DC 3 3 6 Fixed, On-delay A1 15 A2 16 18 A1 15 A2 16 18 XTMT6A60H11B Miniature Electronic Multi-Function Timers with Connection for Remote Potentiometer * Adjustable: * On-delayed * Fleeting contact on energization * Flashing; * Pulse generating XTMT6A60H70B * ON-OFF Actuating Voltage Conventional Rated Operational Current Time Range Thermal I e AC-11 Amps 220/230/240V 380/400/440V Selection Current I e (A) Selectable Function 24-240V 50/60Hz 24-240V DC Adjustable: Z1 On-delayed; Fleeting contact on energization; Flashing; Pulse generating; ON-OFF 6 3 3 .05 - 1 sec 0.15 - 3 sec 0.5 - 10 sec 3 - 60 sec 0.15 - 3 min 0.5 - 10 min 3 - 60 min 0.15 - 3 h 0.5 - 10 h 3 - 60 h Circuit Symbol Eaton list number XTMT6A60H70B Z2 A1 15 A2 16 18 Electronic Star-Delta * Fixed Star-Delta Actuating Voltage Conventional Thermal Current I e (A) Rated Operational Current I e AC-11 Amps 230V 400V 3 3 Time Range Selection Selectable Function 3 - 60 sec Fixed, StarDelta Circuit Symbol Eaton list number XTTR6A60551B 24-240V 6 50/60Hz 24-240V DC A2 12 Relays and Timers XTTR6A60S51B 17 A1 18 28 PG03407001U - June 2006 3 Miniature Controls Miniature Contactors and Overload Relays This chapter provides product selection guidance for Eaton's XT range of Miniature Contactors and Overload relays which are best suited to applications in light duty loads such as hoisting, packaging machinery, material handling, heating, lighting and automation systems. Standards * IEC EN 60947 * CE Marked * UL * CSA * CCC * ATEX Miniature Contactors XTMC9A01A Operational Current AC-3 Amp Rating 380/400V Conventional Free Air Thermal Current AC-1 at 50C Maximum kW Ratings AC-3 3-Phase Motors 50 - 60Hz 220 - 380 - 550V 240V 400V No. of Auxiliary Circuit Power Contacts Symbol Poles Terminals 660/ 690V 6.6 20 1.5 3 3 3 3 1NO 6.6 20 1.5 3 3 3 3 1NC A1 1 3 5 21 8.8 20 2.2 4 4 4 3 1NO A1 1 3 5 13 8.8 20 2.2 4 4 4 3 1NC A1 1 3 5 21 8.8 20 2.2 4 4 4 4 -- A1 1 3 5 13 Screw Spring Cage Eaton list number 1) Eaton list number 1) XTMC6A10_ XTMCC6A1_ A2 2 4 6 14 XTMC6A01_ XTMCC6A0_ M iniatur e C ontr ol s See page 14 for coil suffix. See page 15 for accessories. See page 84 for dimensional drawings. See page 87 for technical details. A2 2 4 6 22 XTMC9A10_ XTMCC9A1_ A2 2 4 6 14 XTMC9A01_ XTMCC9A0_ A2 2 4 6 22 A1 1 3 5 7 XTMF9A00_ -- A2 2 4 6 8 1) Underscore (_) indicates Coil Suffix required. Miniature Contactors Reversing Operational Current AC-3 Amp Rating 380/400V Conventional Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Free Air Thermal Current 220/230/240V 380/400/440V AC-1 at 50C 500V 660/690V 6.6 20 1.5 3 3 3 33 34 34 8.8 20 2.2 4 4 4 33 33 34 34 XTMR9A21 1) 2) Spare Auxiliary Contacts K1M K2M Forward Reversing Contactor Contactor 33 Eaton list number 1)2) XTMR6A21_ XTMR9A21_ Underscore (_) indicates Coil Suffix required. The factory installed reversing miniature contactor includes (2) XTMC...10_ Contactors, (2) XTMCXFD11 1NO1NC Front Mount Auxiliary Contacts (1) XTMCXRL Reversing Link Kit and (1) XTMCXML Mechanical Interlock. PG03407001U - June 2006 Miniature Controls 13 Miniature Contactors Star-Delta * Operating Frequency: 30 Starts/hour * Depending on the coordination type required (i.e. Type 1 or Type 2) it must be established whether the fuse protection and the input wiring for the main and delta contactors are to be common or separate. Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/230/240V 380/400/440V 500V Max. Changeover Time (sec.) 4 5.5 30 MBL216 5.5 Spare Auxiliary Contacts K1M 21 31 53 22 32 54 Component Description Eaton list number 1) K1M Main Contactor K1M Auxiliary Contact K5M Delta Contactor K3M Star Contactor K3M Auxiliary Contact K1T Timing Relay XTMC9A10_ XTMCXFC22 XTMC9A01_ XTMC9A10_ XTMCXFC02 XTTR6A60S51B 1) Underscore (_) indicates coil suffix required. See Table below. M iniatur e C ontr ol s Coil Suffix Coil Voltage 50Hz 110V 220V 230V 24V 415V 550V 190V 240V 380V 400V 12V 24V 42V 48V Suffix Code1) 60Hz DC 120V 240V 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V 120V 220V 12V 24V 48V 1) 2) 14 Miniature Controls A B F T C D E G H L N P R U W Y AD 2) BD 2) RD 2) TD 2) WD 2) Add suffix in place of underscore (_) to Eaton List Number. With DC Operation: Integrated diode-resistor combination, coil consumption 2.6 kW. PG03407001U - June 2006 Front Mount Auxiliary Contacts for Use with Miniature Contactors * Front mounted snap-on auxiliary contacts for miniature contactors are available with screw or spring cage terminals in a variety of contact configurations * Auxiliary contact modules are standard with interlocked opposing contacts, except in the case of earlymake or late-break contacts. XTMCXFAO2 Conventional free air thermal current, Ith = Ie, AC-1 in Amps Poles Contact Configuration 10 2 10 2 1NO-1NC 10 4 2NO-2NC 10 2 2NC 10 2 1NO-1NC 10 2 2NO-0NC 10 2 1NO-1NC 10 4 4NC 10 4 1NO-3NC 10 4 2NO-2NC 10 4 3NO-1NC 10 4 4NO 10 4 2NO-2NC Contact Symbol QPC. 21 31 Terminal Screw Spring Cage Eaton list number Eaton list number 5 XTMCXFC02 -- 5 XTMCXFD11 XTMCXFDC11 5 XTMCXFC22 XTMCXFCC22 5 XTMCXFA02 -- 5 XTMCXFA11 XTMCXFAC11 5 XTMCXFA20 -- 5 XTMCXFAL111) -- 5 XTMCXFA04 XTMCXFAC04 5 XTMCXFA13 XTMCXFAC13 5 XTMCXFA22 XTMXCFAC22 5 XTMCXFA31 XTMCXFAC31 5 XTMCXFA40 XTMCXFAC40 5 XTMCXFAL221) XTMCXFCLC221) 22 32 21 33 22 34 21 31 43 53 51 61 52 62 53 61 54 62 53 63 54 64 57 65 58 66 51 61 71 81 M iniatur e C ontr ol s 22 32 44 54 52 62 72 82 53 61 71 81 54 62 72 82 53 61 71 83 54 62 72 84 53 61 73 83 54 62 74 84 53 63 73 83 54 64 74 84 1) 57 65 71 83 58 66 72 84 1 early make, 1 late break. PG03407001U - June 2006 Miniature Controls 15 RC Suppressor * For AC operated contactors, 50/60 Hz. Note drop-out delay. See page 87. XTMCXRSB Voltage For Use With -- 24 - 48 48 - 130 110 - 250 24 - 48 48 - 130 110 - 250 XTMC6A..., XTMC9A... XTMC6A..., XTMC9A... XTMC6A..., XTMC9A... XTMCC6A..., XTMCC9A... XTMCC6A..., XTMCC9A... XTMCC6A..., XTMCC9A... Circuit Symbol A1 A2 QPC. Eaton list number 10 10 10 10 10 10 XTMCXRSW XTMCXRSA XTMCXRSB XTMCXRSCW XTMCXRSCA XTMCXRSCB Varistor Suppressor M iniatur e C ontr ol s * For AC operated contactors, 50/60 Hz. DC operated contactors have integrated varistor suppressors. XTMCXVSB Voltage For Use With -- 24 - 48 48 - 130 110 - 250 380 - 415 24 - 48 48 - 130 110 - 250 XTMC6A..., XTMC9A... XTMC6A..., XTMC9A... XTMC6A..., XTMC9A... XTMC6A..., XTMC9A... XTMCC6A..., XTMCC9A... XTMCC6A..., XTMCC9A... XTMCC6A..., XTMCC9A... Circuit Symbol A1 A2 QPC. Eaton list number 10 10 10 10 10 10 10 XTMCXVSW XTMCXVSA XTMCXVSB XTMCXVSN XTMCXVSCW XTMCXVSCA XTMCXVSCB Star Delta Bridge * Protected against direct contact in accordance with IEC 536 Description Circuit Symbol Star Delta Bridge QPC. Eaton list number 20 XTMCXSDB XTMCXSDB Star Delta Link Kit * The following control cables are integrated in addition to the electrical interlock: K3M: A1 -- K5M: 21; K3M: 21 -- K5M: A1; K3M: A2 -- K5M: A2 * When combined with overload relay use separate mounting. Description QPC. Eaton list number Main current wiring for star-delta combinations. Includes the Star-Delta Bridge. 1 XTMCXSDL XTMCXSDL 16 Miniature Controls PG03407001U - June 2006 Paralleling Link Set for Main Contacts * Protected against direct contact in accordance with IEC 536. * 4th pole can be broken off: 4-pole: Ith = 60A; 3-pole: Ith = 50A * AC-1 current carrying capacity of the open contactor increases by a factor of 2.5. Description Circuit Symbol Paralleling Link Set for main Contacts QPC. Eaton list number 5 XTMCXPLK XTMCXPLK Reversing Link Kit * When combined with overload relay use separate mounting. Description QPC. Eaton list number Main current wiring for reversing contactors and starters. 1 XTMCXRL XTMCXRL Mechanical Interlock * For two contactors with AC or DC operated magnet system that are horizontally mounted, the distance between contactors is 0 mm, and the mechanical lifespan is 2.5 x 106 operations. Description Mechanical Interlock QPC. Eaton list number M iniatur e C ontr ol s * The following control cables are integrated in addition to the electrical interlock: K3M: A1 -- K5M: 21; K3M: 21 -- K5M: A1; K3M: A2 -- K5M: A2 XTMCXML 5 XTMCXML Connector * 0 mm distance between contactors. Description QPC. Eaton list number For mechanically arranging contactors and timing relays in combinations. 50 XTMCXCN XTMCXCN IP40 Sealable Transparent Shroud Description QPC. Eaton list number IP40 Sealable Transparent Shroud, snap fitting on miniature contactor. 1 XTMCXSHROUD XTMCXSHROUD PG03407001U - June 2006 Miniature Controls 17 Miniature Overload Relays * See page 91 for Tripping Characteristics. * When fitted directly to the contactor, a clearance of at least 5 mm is required between the overload relays. Overload Release It Trip Class Contact Configuration 0.1 - 0.16A 0.16 - 0.24A 0.24 - 0.4A 0.4 - 0.6A 0.6 - 1A 1 - 1.6A 1.6 - 2.4A 10A 1NO-1NC 10A 1NO-1NC Circuit Symbol XTOMO12AC1 97 95 2 4 6 98 96 97 95 Short Circuit Protection (A) Type 1 Type 2 Coordination, Coordination, gG/gL gG/gL Circuit Breaker 20 20 20 20 20 20 20 15 15 15 15 15 15 15 XTOMP16AC1 XTOMP24AC1 XTOMP40AC1 XTOMP60AC1 XTOM001AC1 XTOM1P6AC1 XTOM2P4AC1 15 15 15 -- XTOM004AC1 XTOM006AC1 XTOM009AC1 XTOM012AC1 0.5 1 2 2 4 6 6 Eaton list number 2 4 6 98 96 10A 1NO-1NC 97 95 2 4 6 98 96 20 20 20 -- 10 10 10 -- M iniatur e C ontr ol s 2.4 - 4A 4 - 6A 6 - 9A 9 - 12A 18 Miniature Controls PG03407001U - June 2006 4 Contactors and Overload Relays This chapter provides product selection guidance for Eaton's XT range of Contactors, Overload relays and accessories which includes non-reversing and reversing contactors, frame sizes B through R, 20A through 2000A AC-1 respectively, Direct mount, separate mount and Current transformer operated overload relays. Standards * IEC EN 60947 * CE Marked * UL * CSA * CCC * ATEX See page 25 for coil suffix. See page 26 for accessories. See page 35 for overload relays. See page 92 for dimensions. See page 106 for the technical details . See page 160 for Type 2 Co-ordination. I e (A) AC-3 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact Eaton 1)2)3) list number 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC XTCE007B10_ XTCE007B01_ XTCE009B10_ XTCE009B01_ XTCE012B10_ XTCE012B01_ XTCE015B10_ XTCE015B01_ AC-1 220/ 230V 380/ 400V 2.2 2.2 2.5 2.5 3.5 3.5 4 4 3 3 4 4 5.5 5.5 7.5 7.5 415V 660/ 690V 1000V XTCE007810B 7 7 9 9 12 12 15.5 15.5 1) 2) 3) 20 20 20 20 20 20 20 20 4 4 5.5 5.5 7 7 8 8 3.5 3.5 4.5 4.5 6.5 6.5 7 7 -- -- -- -- -- -- -- -- Underscore (_) indicates coil suffix required. 7 - 150A DC operated contactors have an integrated suppressor. For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 7 - 15A XTCEC Contactors, the power, auxiliary and coil terminals are spring cage. 3 - Pole Contactors Frame C,(18 - 32A) 10kW - 18kW (415V) I e (A) AC-3 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact AC-1 220/ 230V 380/ 400V 5 5 7.5 7.5 10 10 7.5 7.5 11 11 15 15 415V 660/ C on tacto rs and O ver load R elays 3 - Pole Contactors, Frame B, (7 - 15.5A) 4kW - 8kW (415V) Terminals 1)2)3) Screw Eaton list number 1000V 690V XTCE018C10B 18 18 25 25 32 32 1) 2) 3) 35 35 40 40 40 40 10 10 14.5 14.5 18 18 11 11 14 14 17 17 -- -- -- -- -- -- 1NO 1NC 1NO 1NC 1NO 1NC XTCE018C10_ XTCE018C01_ XTCE025C10_ XTCE025C01_ XTCE032C10_ XTCE032C01_ Underscore (_) indicates coil suffix required. 7 - 150A DC operated contactors have an integrated suppressor. For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 18 - 32A XTCEC Contactors, the auxiliary and coil terminals are spring cage. PG03407001U - June 2006 Contactors and Overload Relays 19 3 - Pole Contactors Frame D, (40 - 65A) 24kW - 39kW (415V) I e (A) AC-3 XTCE040D00B 40 50 65 1) 2) 3) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact Eaton 1)2)3) list number -- -- -- XTCE040D00_ XTCE050D00_ XTCE065D00_ AC-1 50 65 80 220/ 230V 380/ 400V 415V 12.5 15.5 20 18.5 22 30 24 30 39 660/ 1000V 690V 23 30 35 -- -- -- Underscore (_) indicates coil suffix required. 7 - 150A DC operated contactors have an integrated suppressor. For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 40 - 150A XTCEC Contactors, the coil terminals only are spring cage. 3 - Pole Contactors Frame F, (80 -95A) 48kW - 57kW (415V) I e (A) AC-3 XTCE080F00B 80 95 1) 2) C on tacto rs and O ver load R elays 3) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Eaton 1)2)3) list number -- -- XTCE080F00_ XTCE095F00_ AC-1 90 110 220/ 230V 380/ 400V 25 30 37 45 415V 660/ 1000V 690V 48 57 63 75 45 55 Underscore (_) indicates coil suffix required. 7 - 150A DC operated contactors have an integrated suppressor. For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 40 - 150A XTCEC Contactors, the coil terminals only are spring cage. 3 - Pole Contactors Frame G, (115 - 150A) 70kW -91kW (415V) I e (A) AC-3 XTCE115G00B 115 150 1) 2) 3) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact Eaton list 1)2)3) number -- -- XTCE115G00_ XTCE150G00_ AC-1 130 160 220/ 230V 380/ 400V 37 48 55 75 415V 660/ 1000V 690V 70 91 90 96 66 80 Underscore (_) indicates coil suffix required. 7 - 150A DC operated contactors have an integrated suppressor. For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A. For 40 - 150A XTCEC Contactors, the coil terminals only are spring cage. 3 - Pole Contactors Frame L, (185 -250A) 110kW - 148kW (415V) I e (A) AC-3 XTCE185L22A 185 225 250 1) 2) 3) 4) 20 Aux. Contact Contactors and Overload Relays Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact Eaton 1)2)3) list number 2NO-2NC 2NO-2NC 2NO-2NC XTCE185L22_ XTCE225L22_ XTCE250L22_ AC-1 275 315 350 220/ 230V 380/ 400V 415V 55 70 75 90 110 132 110 132 148 660/ 1000V4) 690V 4) 175 215 240 108 108 108 Underscore (_) indicates coil suffix required. 185 - 2000A AC and DC contactors have an integrated suppressor. For Spring Cage Terminals, insert C after the fourth digit of the Eaton list number. Example: XTCEC007B10A.185 - 2000A Contactors are available with screw terminals only. For 185 - 2000A Contactors at 660/690V or 1000V: Do not reverse directly. PG03407001U - June 2006 3 - Pole Contactors Frame M, (300 - 500A) 180kW - 300kW (415V) I e (A) AC-3 XTCE300M22A 300 400 500 1) 2) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact Eaton 1)2) list number 2NO-2NC 2NO-2NC 2NO-2NC XTCE300M22_ XTCE400M22_ XTCE500M22_ AC-1 400 500 700 220/ 230V 380/ 400V 415V 90 125 155 160 200 250 180 240 300 660/ 1000V1) 690V 1) 286 344 344 132 132 132 Underscore (_) indicates coil suffix required. For 185 - 2000A Contactors at 660/690V or 1000V: Do not reverse directly. 3 - Pole Contactors Frame N, (580 - 1000A) 348kW - 610kW 415V) I e (A) Aux. Contact AC-1 220/ 230V 380/ 400V 415V 185 205 240 260 315 315 355 400 450 560 348 390 455 500 610 660/ 1000V4) 690V 4) XTCE580N22B 580 650 750 820 1000 1) 2) 3) 4) Eaton 1)2)3) list number -- 800 850 900 1000 1000 560 630 720 750 1000 600 600 800 800 1000 2NO-2NC 2NO-2NC 2NO-2NC 2NO-2NC 2NO-2NC XTCE580N22_ XTCE650N22_ XTCE750N22_ XTCE820N22_ XTCEC10N22_ Underscore (_) indicates coil suffix required. 185 - 2000A AC and DC contactors have an integrated suppressor. When operating the 580 - 2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be removed when performing a high-voltage test. For 185 - 2000A Contactors at 660/690V or 1000V: Do not reverse directly. 3 - Pole Contactors Frame P, (1400A AC1) I e (A) AC-3 XTCEC14P22B -- 1) 2) 3) 4) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact Eaton 1)2) list number 2NO-2NC XTCEC14P22_ AC-1 1400 3) 220/ 230V 380/ 400V 415V -- -- -- 660/ 1000V 690V 4) 4) -- -- Underscore (_) indicates coil suffix required. When operating the 580 - 2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be removed when performing a high-voltage test. AC-1 Ratings Only. For 185 - 2000A Contactors at 660/690V or 1000V: Do not reverse directly. C on tacto rs and O ver load R elays AC-3 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 3 - Pole Contactor Frame R, (2000A AC1) I e (A) AC-3 XTCEC20R22 -- 1) 2) 3) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz Aux. Contact Eaton 2) list number 2NO-2NC XTCEC20R22_ AC-1 2000 3) 220/ 230V 380/ 400V 415V -- -- -- 660/ 1000V 690V -- -- Underscore (_) indicates coil suffix required. When operating the 580 - 2000A XTCE contactors with frequency inverters, the suppressor on the load side must be removed. The load side suppressor must also be removed when performing a high-voltage test. AC-1 Ratings Only. PG03407001U - June 2006 Contactors and Overload Relays 21 4-Pole Contactors - Frame B I e (A) AC-3 12 AC-1 20 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 230V 400V Contact Sequence 660/ 690V 3.5 6.5 5.5 Eaton list number 1) 1000V XTCF020B00_ A1 1 3 5 7 XTCF020B00B A2 2 4 6 8 1) Underscore (_) indicates magnet coil suffix required. See Table page 25. Add-on 4th Pole, Frame D Contactor I e (A) AC-3 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz AC1 Rated 4th Pole AC-1 220/ 230V 40 50 65 Fits on Contactor 50 60 72 12.5 15.5 20 380/ 400V 18.5 22 30 415V 24 30 39 660/ 690V 23 30 35 1000V -- -- -- XTCE040D00_ XTCE050D00_ XTCE065D00_ 35A 75A Eaton list number Eaton list number XTCEX4P35D XTCEX4P35D XTCEX4P35D XTCEXP75D XTCEXP75D XTCEXP75D C on tacto rs and O ver load R elays Note: Up to 2 auxiliary contacts can also be fitted. 22 Contactors and Overload Relays PG03407001U - June 2006 3 Pole Contactors, Frame B, Reversing * The factory assembled reversing contactor for the 7 - 32A devices includes: (2) XTCE...01_ Contactors, (2) XTCEXFAC20 2NO Seq. A Front Mount Auxiliary Contacts, (1) XTCEXRL Reversing Link Kit and (1) XTCEXML_ Mechanical Interlock. XTCR012B21 I e (A) Maximum kW Ratings AC-3 AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 230V 400V Spare Auxiliary Contacts K1M 415V Eaton list number 1) K2M 660/ 690V 7 2.2 3 4 3.5 9 2.5 4 5.5 4.5 12 3.5 5.5 7 6.5 63 63 64 64 63 63 64 64 63 63 64 64 XTCR007B21_ XTCR009B21_ XTCR012B21_ 1)Underscore (_) indicatest coil suffix required. 3 Pole Contactors, Frame C, Reversing XTCR032C21 I e (A) Maximum kW Ratings AC-3 AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 230V 400V 18 5 25 7.5 32 10 Spare Auxiliary Contacts K1M 415V 660/ 690V 8 11 11 14.5 14 15 18 17 7.5 Eaton list number 1) K2M 63 63 64 64 63 63 64 64 63 63 64 64 XTCR018C21_ XTCR025C21_ XTCR032C21_ 1)Underscore (_) indicates coil suffix required. 3 Pole Contactors, Frame D, Reversing * The factory assembled reversing contactor for the 40 - 150A devices includes: (2) XTCE...00_ Contactors and (2) XTCEXFBG11, 1NO-1NC Seq. B Front Mount Auxiliary Contacts and (1) XTCEXML_Mechanical Interlock. XTCR065D11 I e (A) Maximum kW Ratings AC-3 AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 230V 400V 415V 12.5 15.5 20 24 30 39 40 50 65 18.5 22 30 Spare Auxiliary Contacts K1M C on tacto rs and O ver load R elays * The factory assembled reversing contactor for the 7 - 32A devices includes: (2) XTCE...01_ Contactors, (2) XTCEXFAC20 2NO Seq. A Front Mount Auxiliary Contacts, (1) XTCEXRL Reversing Link Kit and (1) XTCEXML_ Mechanical Interlock. Eaton list number 1) K2M 660/ 690V 23 30 35 XTCR040D11_ XTCR050D11_ XTCR065D11_ 1)Underscore (_) indicates coil suffix required. PG03407001U - June 2006 Contactors and Overload Relays 23 3 Pole Contactors, Frame F, Reversing * The factory assembled reversing contactor for the 40 - 150A devices includes: (2) XTCE...00_ Contactors and (2) XTCEXFBG11 1NO-1NC Seq. B Front Mount Auxiliary Contacts and (1) XTCEXML_Mechanical Interlock. XTCR095F11 I e (A) Maximum kW Ratings AC-3 AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 230V 400V 415V 660/ 690V 25 30 48 57 63 75 80 95 37 45 Spare Auxiliary Contacts K1M Eaton K2M list number 1) XTCR080F11_ XTCR095F11_ 1)Underscore (_) indicates coil suffix required. 3 Pole Contactors, Frame G, Reversing * The factory assembled reversing contactor for the 40 - 150A devices includes: (2) XTCE...00_ Contactors and (2) XTCEXFBG11 1NO-1NC Seq. B Front Mount Auxiliary Contacts and (1) XTCEXML_Mechanical Interlock. C on tacto rs and O ver load R elays XTCR150G11 24 I e (A) Maximum kW Ratings AC-3 AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 230V 400V 415V 660/ 690V 37 48 70 91 90 96 115 150 55 75 Spare Auxiliary Contacts K1M Eaton K2M list number 1) XTCR115G11_ XTCR150G11_ 1)Underscore (_) indicates coil suffix required. Contactors and Overload Relays PG03407001U - June 2006 Coil Suffix Frame C - F 110V 220V 230V 24V 415V 550V 190V 240V 380V 400V 12V 24V 42V 48V Frame G 100 - 120V 190 - 240V 24V 480 - 500V 380 - 440V 42 - 48V Frame L - M 110 - 250V 250 - 500V 48 - 110V 60Hz DC 120V 240V A B F T C D E G H L N P R U W Y 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V 60 Hz 110 - 130V AD 1) 200 - 240V BD 1) 12 - 14V RD 1) 24 - 27V TD 1) 48 - 60V WD 1) 100 - 120V 190 - 240V 24V 480 - 500V 380 - 440V 42 - 48V 110 - 250V 250 - 500V 48 - 110V Suffix Code A B T C L W 24 - 27V TD 1) 110 - 130V AD 1) 200 - 240V BD 1) 48 - 60V WD 1) 110 - 250V A C 48 - 110V Y 1) 24 - 48V TD 1) 1) With DC operation: integrated diode resistor combination coil rating 2.6W PG03407001U - June 2006 Contactors and Overload Relays C on tacto rs and O ver load R elays Coil Voltage 50Hz 25 Front Mount Auxiliary Contacts, Frame B - C * Front mounted snap-on contacts for XT contactors are available with screw or spring cage terminals in a variety of contact configurations. ConventionalFree Air Poles Thermal Current, Ith = Ie AC-1 in Amps Contact Configuration 16 2 2NO 16 2 1NO-1NC 16 2 2NC 16 2 1NO-1NC 57 65 16 2 1NO-1NC 21 33 XTCEXFCC22 Circuit Symbol 53 63 QPC Terminals Screw Spring Cage Eaton list number Eaton list number 5 XTCEXFAC20 XTCEXFACC20 5 XTCEXFAC11 XTCEXFACC11 5 XTCEXFAC02 XTCEXFACC02 5 XTCEXFALC11 1) XTCEXFALCC11 1) 5 XTCEXFDC112) XTCEXFDCC112) 5 XTCEXFCC022) XTCEXFCCC022) 5 XTCEXFAC40 XTCEXFACC40 5 XTCEXFAC31 XTCEXFACC31 5 XTCEXFAC22 XTCEXFACC22 5 XTCEXFAC13 XTCEXFACC13 5 XTCEXFAC04 XTCEXFACC04 5 XTCEXFAC221) XTCEXFACC221) 5 XTCEXFCC222) XTCEXFCCC222) 54 64 53 61 54 62 51 61 52 62 58 66 22 34 21 31 16 2 2NC 21 31 16 4 4NO 53 6373 83 16 4 3NO-1NC 53 61 73 83 16 4 2NO-2NC 16 4 1NO-3NC 16 4 4NC 16 4 1NOE-1NCL 16 4 2NO-2NC 22 32 54 6474 84 C on tacto rs and O ver load R elays 54 62 74 84 5361 71 83 54 62 72 84 536171 81 54 62 72 82 51 61 71 81 52 62 72 82 5765 71 83 58 66 72 84 21 31 43 53 22 32 44 54 1) 1early-make contact, 1 late-break contact. 2) To avoid duplicate terminal numbers in contact sequence these auxilary contacts should be used with contactors with a built-in (normally open) contact. Frame B - C, - Front (Top) Mount - Tall Version1) Accessoires voor ConventionalFree Air Poles Thermal Current, Ith = Ie, AC-1 in Amps Contact Configuration 16 2 2NO 16 2 1NO-1NC 16 2 2NC 16 4 2NO-2NC Circuit Symbol 53 63 QPC Terminals Screw Spring Cage Eaton list number Eaton list number 5 XTCEXFATC20 5 XTCEXFATC11 5 XTCEXFATC02 5 XTCEXFATC22 54 64 53 61 54 62 51 61 52 62 5361 71 83 XTCEXFACC22 54 62 72 84 1) Front (Top) Mount Tall Version is for use with Frame B Electrical Wire Bridges and Link Kits and toolless plug combination connection kits: XTCEXRLB, XTCEXDLB, XTPAXTPCB, XTPAXTPCRB, XTPAX. Notes: * Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (Positively driven) within the auxiliary contact modules. (not N/O (early make) and N/C (late break) contacts) and for the built-in auxiliary contacts of the XTCE007B...XTCE032C... * Auxilliary break contact can be used as a mirror contact to IEC/EN 60947-4-1 Annex F (not N/C (late break) contact) * No auxiliary contacts can be fitted between 2 contactors. 26 Contactors and Overload Relays PG03407001U - June 2006 Front Mount Auxiliary Contacts, Frames D - G XTCEXFBG22 Conventional Free Air Thermal Current, Ith = Ie AC-1 in Amps Poles 16 2 2NO 13 23 16 2 1NO-1NC 16 2 1NO-1NC 16 2 2NC 16 4 4NO-0NC 16 4 3NO-1NC 13 21 33 43 16 4 2NO-2NC 13 21 31 43 16 4 2NO-2NC 16 4 1NO-3NC 16 4 0NO-4NC 11 2131 41 16 4 1NO6-1NCL 13 21 35 47 Contact Configuration Circuit Symbol QPC Terminals Screw Spring Cage Eaton list number Eaton list number 5 XTCEXFBG20 -- 53 61 5 XTCEXFAG11 -- 54 62 13 21 5 XTCEXFBG11 -- 5 XTCEXFBG02 -- 5 XTCEXFBG40 XTCEXFBGC40 5 XTCEXFBG31 XTCEXFBGC31 5 XTCEXFBG22 XTCEXFBGC32 53 61 71 83 5 XTCEXFAG22 XTCEXFAGC22 54 62 72 84 13 21 31 41 5 XTCEXFBG13 XTCEXFBGC13 5 XTCEXFBG04 XTCEXFBGC04 5 XTCEXFBLG22 1) XTCEXFBLGC22 1) QPC Terminals 14 24 14 22 11 21 12 22 13 23 33 43 14 24 34 44 14 22 34 44 14 22 32 44 12 2232 42 14 22 36 48 1) 1early-make contact, 1 late-break contact. Side Mount Auxiliary Contacts for Frame B - C1) ConventionalFree Air Poles Thermal Current, Ith = Ie, AC-1 in Amps Contact Configuration 10 1NO-1NC 2 Circuit Symbol 53 61 1 Screw Spring Cage Eaton list number Eaton list number XTCEXSCC11 54 62 1) Can be mounted to the left side of contactor only. Cannot be used in combination with Front (Top) Mount Auxiliary contacts or mechanical interlocks C on tacto rs and O ver load R elays 14 2232 42 Side Mount Auxiliary Contacts for Frame D - R, (40 - 2000A) Conventional Poles Contact Configuration Circuit Symbol QPC. Free Air Thermal Current, Ith = Ie, AC-1 in Amps 14 17 61 83 62 71 54 1) 84 53 26 72 1NO-1NC 47 2 25 35 10 22 48 18 43 1NO-1NC1) 21 13 31 2 1NO-1NC 36 10 2 44 10 32 XTCEXSBLN11 Terminals Screw Spring Cage Eaton list number Eaton list number 1 XTCEXSBN11 XTCEXSBNC11 1 XTCEXSBLN11 -- 1 XTCEXSCN11 XTCEXSCNC11 1early-make contact, 1 late-break contact. PG03407001U - June 2006 Contactors and Overload Relays 27 RC Coil Suppressor * Note drop-out delay. * For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor. XTCEXRSBB Coil Voltage Description 24 - 48 48 - 130 110 - 240 240 - 500 Coil Suppressor for use with XTCE007B - XTCE015B, XTCF020B 24 - 48 110 - 130 110 - 240 240 - 500 Coil Suppressor for use with XTCE018C - XTCE032C 24 - 48 110 - 130 110 - 240 240 - 500 Coil Suppressor for use with XTCE040D - XTCE095F Circuit Symbol A1 A2 A1 A2 A1 A2 QPC Eaton List number 10 10 10 10 XTCEXRSBW XTCEXRSBA XTCEXRSBB XTCEXRSBC 10 10 10 10 XTCEXRSCW XTCEXRSCA XTCEXRSCB XTCEXRSCC 10 10 10 10 XTCEXRSFW XTCEXRSFA XTCEXRSFB XTCEXRSFC Varistor Coil Suppressor * Note drop-out delay. C on tacto rs and O ver load R elays * For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor. XTCEXVSBA Coil Voltage Description 24 - 48 48 - 130 130 - 240 240 - 500 24 - 48 48 - 130 130 - 240 240 - 500 24 - 48 48 - 130 130 - 240 240 - 500 Coil Suppressor for use with XTCE007B - XTCE015B, XTCF020B Circuit Symbol A1 A2 Coil Suppressor for use with XTCE018C - XTCE032C A1 A2 Coil Suppressor for use with XTCE040D - XTCE095F A1 A2 QPC Eaton list number 10 10 10 10 10 10 10 10 10 10 10 10 XTCEXVSBW XTCEXVSBA XTCEXVSBB XTCEXVSBC XTCEXVSCW XTCEXVSCA XTCEXVSCB XTCEXVSCC XTCEXVSFW XTCEXVSFA XTCEXVSFB XTCEXVSFC Varistor Coil Suppressor with Integrated LED * Note drop-out delay. * For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor. Coil Voltage Description 24 - 48 130 - 240 Coil Suppressor for use with XTCE007B - XTCE015B Circuit Symbol A1 QPC Eaton list number 10 10 XTCEXVSLBW XTCEXVSLBB 10 10 XTCEXVSLCW XTCEXVSLCB 10 10 XTCEXVSLFW XTCEXVSLFB A2 XTCEXVSLBB 24 - 48 130 - 240 Coil Suppressor for use with XTCE018C - XTCE032C A1 A2 29 - 48 130 - 240 Coil Suppressor for use with XTCE040D - XTCE095F A1 A2 28 Contactors and Overload Relays PG03407001U - June 2006 Voltage Indicator XTCEXVIBA Coil Voltage Description QPC Eaton list number 24 - 48 110 - 120 110 - 250 24 - 48 110 - 130 130 - 250 42 - 48 50/60 Hz 48 - 130 130 - 250 Voltage Indicator for use with XTCE007B - XTCE015B, XTCF020B 10 10 10 10 10 10 10 XTCEXVIBW XTCEXVIBA XTCEXVIBB XTCEXVICW XTCEXVICA XTCEXVICB XTCEXVIGW 10 10 XTCEXVIGA XTCEXVIGB Voltage Indicator for use with XTCE018C - XTCE032C Voltage Indicator for use with XTCE040D - XTCE150G Contactors, Frames B - G, Mechanical Coupling * For mechanically coupling contactors in combinations. Distance between contactors is 0 mm. Description QPC Eaton list number Mechanical Coupling for use with XTCE007B - XTCE032C Mechanical Coupling for use withXTCE040D - XTCE0150G 50 50 XTCEXCNC XTCEXCNG XTCEXCNC * For two contactors with AC or DC operated magnet system which are horizontally mounted. For B - G Frames, mechanical lifespan is 2.5 x 106 operations and the distance between contactors is 0 mm. For L - N frames mechanical lifespan is 5 x 106 operations and no auxiliary contact can be mounted between the mechanical interlock and the contactor. The distance between contactors is 15 mm. XTCEXMLN consists of an interlock element and mounting plate. XTCEXMLB Description QPC Eaton list number Mechanical Interlock for use with XTCE007B XTCE015B, XTCF020B Mechanical Interlock for use with XTCE007B - XTCE015B,XTCF020B Mechanical Interlock for use with XTCE018C - XTCE032C Mechanical Interlock for use with XTCE040D - XTCE065D Mechanical Interlock for use with XTAE080F - XTCE150G Mechanical Interlock for use with XTCE185L - XTCE500M Mechanical Interlock for use with XTCE580N - XTCEC10N 5 5 1 1 1 1 1 XTCEXMLB XTCEXMLB XTCEXMLC XTCEXMLD XTCEXMLG XTCEXMLM XTCEXMLN Description QPC Eaton list number Interlocking Bridge for use with XTCE007B - XTCE015B 20 XTCEXLBB Description QPC Eaton list number Paralleling Bridge for use with XTCE007B - XTCE015B Paralleling Bridge for use with XTCE018C - XTCE032C 20 20 XTCEXPBB XTCEXPBC Contactor, Frame B, Interlocking Bridge C on tacto rs and O ver load R elays Contactors, Frames B - N, Mechanical Interlock XTCEXLBB Contactors, Frame B - C, Paralleling Bridge XTCEXPBB PG03407001U - June 2006 Contactors and Overload Relays 29 Contactors, Frames B - L, Electrical Parallel Link * 4th Pole can be broken off: 4-Pole: Ith = 60A; 3-Pole: Ith = 50A. * AC-1 current carrying capacity of the contactor increases by a factor of 2.5. For XTCEXPLKL185, one shroud is included for protection against accidental contact * Protected against accidental contact in accordance with IEC 536. XTCEXPLKB Description QPC Eaton list number Electrical Parallel Link for use with XTCE007B - XTCE015B Electrical Parallel Link for use with XTCE018C - XTCE032C Electrical Parallel Link for use with XTCE040D - XTCE065D Electrical Parallel Link for use with XTCE080F - XTCE150G Electrical Parallel Link for use with XTCE185L 5 5 1 1 1 XTCEXPLKB XTCEXPLKC XTCEXPLKD XTCEXPLKG XTCEXPLKL185 Description QPC. Eaton list number Electrical 3 phase Commoning Link for use with 3 Contactors Electrical 3 phase Commoning Link for use with 4 Contactors Electrical 3 phase Commoning Link for use with 5 Contactors 5 5 5 XTCEXCLK3B XTCEXCLK4B XTCEXCLK5B QPC Eaton list number Contactors, Frame B, Electrical 3 Phase Commoning Link XTCEXCLK3B Contactors, Frame B - M, Star Delta Electrical Bridge C on tacto rs and O ver load R elays Description XTCEXSDBB Star Delta Electrical Bridge for use with XTCE0 07B - XTCE015B Star Delta Electrical Bridge for use with XTCE018C - XTCE032C Star Delta Electrical Bridge for use with XTCE040D - XTCE065D Star Delta Electrical Bridge for use with XTCE080F -- XTCE150G Star Delta Electrical Bridge for use with XTCE185L - XTCE400M Star Delta Electrical Bridge for use with XTCE50 0M XTCEXSDBB XTCEXSDBC XTCEXSDBD XTCEXSDBG XTCEXSDB400 XTCEXSDB500 20 20 10 1 1 1 Contactors, Frame B - C, Star Delta Electrical Link Kits * Main current wiring for star-delta combinations. Includes the Star-Delta bridge. * Star Delta Link Kits do not include mechanical interlocks, see page 29. * The following control cables are integrated in addition to the electrical interlock: (K3M: A1 - K5M: 21), (K3M: 21 - K5M: A1), (K3M: A2 - K5M: A2). Description QPC Eaton list number Star Delta Electrical Link Kit for use with XTCE007B - XTCE015B Star Delta Electrical Link Kit for use with XTCE018C - XTCE032C 1 1 XTCEXSDLB XTCEXSDLC XTCEXSDLB Reversing Link Kit * Main current wiring for reversing contactors and starters. * Reversing Link Kits do not include mechanical interlocks, see page 29. * The following control cables are integrated in addition to the electrical interlock: (K1M: A1 - K2M: 21), (K1M: 21 - K2M: A1), (K1M: A2 - K2M: A2). Description QPC Eaton list number Reversing Electrical Link Kit for use with XTCE007B - XTCE012B Reversing Electrical Link Kit for use with XTCE018C - XTCE032C 1 1 XTCEXRLB XTCEXRLC XTCEXRLC 30 Contactors and Overload Relays PG03407001U - June 2006 Contactors, Frames B - C Reversing Electrical Bridge Description QPC Eaton list number Reversing Electrical Bridge for use with XTCE007B - XTCE105B Reversing Electrical Bridge for use with XTCE018C - XTCE032C 20 20 XTCEXRBB XTCEXRBC Description QPC Eaton list number Incoming Terminal for use with XTCE007B - XTCE015B 5 XTCEXITB XTCEXRBB Contactor, Frame B, Incoming Terminal Contactors, Frames L - M, Terminal Lug Assembly Description QPC Eaton list number Terminal Lug Assembly for use with XTCE185L - XTCE225L Terminal Lug Assembly for use with XTCE250L - XTCE400M 1 1 XTCEXTLA225 XTCEXTLA400 QPC Eaton list number XTCEXTLA400 Contactors, Frames M - N, Set of (3) Lugs Description Set of 3 Lugs #4-500MCM 2-Phase Cu/Al 500A for use with XTCE500M Set of 3 Lugs #2-500MCM 2-Phase Cu/Al 650A for use with XTCE650N Set of 3 Lugs #2-500MCM 4-Phase Cu/Al 820A or use with XTCE820N 1 1 1 XTCEXTL500 XTCEXTL650 XTCEXTL820 XTCEXTL500 Contactors, Frames M - N, Terminal Flat Bar * For connection of a flat strip conductor. Comes with control circuit terminal (Consisting of 3 flat strip conductor terminals). Description QPC Eaton list number Terminal Flat Bar for use with XTCE500M - XTCE650N Terminal Flat Bar for use with XTCE750N - XTCE820N 1 1 XTCEXTFB650 XTCEXTFB820 C on tacto rs and O ver load R elays * For connection of round, flexible and stranded flat strip conductor. With control circuit terminal. XTCEXTFB650 PG03407001U - June 2006 Contactors and Overload Relays 31 Contactors, Frames M - L, Terminal Shrouds * Protection against direct contact with connection lugs when touched vertically from the front. Description QPC Eaton list number Terminal Shroud for use with XTCE185L - XTCE400M Terminal Shroud for use with XTCE500M Terminal Shroud for use with XTCE580N - XTCE650N Terminal Shroud for use with XTCE750N - XTCEC10N 1 1 1 1 XTCEXTS400 XTCEXTS500 XTCEXTS650 XTCEXTS820 Description QPC Eaton list number Control Wire Terminal Extension for use with XTCE080F - XTCE150G 10 XTCEXTCWG XTCEXTS400 Contactors, Frames F - G, Control Wire Terminal Extension C on tacto rs and O ver load R elays XTCEXTCWG 32 Contactors and Overload Relays PG03407001U - June 2006 Contactors, Frames C - N, Replacement Coils * See page 124 for technical details. Frame Size Voltage 50Hz 60Hz 110 120 Contactor List Number Coil Suffix Eaton list number A AD B BD C D E F G H L N P R RD T TD U W WD Y XTCERENCOILCA XTCERENCOILCAD XTCERENCOILCB XTCERENCOILCBD XTCERENCOILCC XTCERENCOILCD XTCERENCOILCE XTCERENCOILCF XTCERENCOILCG XTCERENCOILCH XTCERENCOILCL XTCERENCOILCN XTCERENCOILCP XTCERENCOILCR XTCERENCOILCRD XTCERENCOILCT XTCERENCOILCTD XTCERENCOILCU XTCERENCOILCW XTCERENCOILCWD XTCERENCOILCY A AD B BD C D E F G H L N P R RD T TD U W WD Y XTCERENCOILDA XTCERENCOILDAD XTCERENCOILDB XTCERENCOILDBD XTCERENCOILDC XTCERENCOILDD XTCERENCOILDE XTCERENCOILDF XTCERENCOILDG XTCERENCOILDH XTCERENCOILDL XTCERENCOILDN XTCERENCOILDP XTCERENCOILDR XTCERENCOILDRD XTCERENCOILDT XTCERENCOILDTD XTCERENCOILDU XTCERENCOILDW XTCERENCOILDWD XTCERENCOILDY A AD B BD C D E F G H L N P R T TD U W WD Y XTCERENCOILFA XTCERENCOILFAD XTCERENCOILFB XTCERENCOILFBD XTCERENCOILFC XTCERENCOILFD XTCERENCOILFE XTCERENCOILFF XTCERENCOILFG XTCERENCOILFH XTCERENCOILFL XTCERENCOILFN XTCERENCOILFP XTCERENCOILFR XTCERENCOILFT XTCERENCOILFTD XTCERENCOILFU XTCERENCOILFW XTCERENCOILFWD XTCERENCOILFY DC Frame C 110 - 130 220 240 415 550 480 600 208 200 - 240 230 190 240 380 400 220 277 440 12 380 12 24 24 12 - 14 24 - 27 24 42 48 48 - 60 48 110 120 110 - 130 220 240 415 550 480 600 208 200 - 240 230 190 240 380 400 220 277 440 12 380 12 24 /60 24 12 - 14 24 - 27 24 42 48 48 - 60 48 Frame F 110 120 110 - 130 220 240 415 550 480 600 208 200 - 240 230 190 240 380 400 12 24 220 277 440 380 12 24 24 - 27 24 42 48 48 - 60 48 PG03407001U - June 2006 Contactors and Overload Relays C on tacto rs and O ver load R elays Frame D 33 Replacement Coils (Continued) Frame Size Voltage 50Hz 60Hz 100 - 120V 100 - 120V Contactor List Number Coil Suffix Eaton list number A AD B BD C L T TD W WD XTCERENCOILGA XTCERENCOILGAD XTCERENCOILGB XTCERENCOILGBD XTCERENCOILGC XTCERENCOILGL XTCERENCOILGT XTCERENCOILGTD XTCERENCOILGW XTCERENCOILGWD A C TD Y XTCERENCOILLA XTCERENCOILLC XTCERENCOILLTD XTCERENCOILLY A C TD Y XTCERENCOILMA XTCERENCOILMC XTCERENCOILMTD XTCERENCOILMY A C Y XTCERENCOILNA XTCERENCOILNC XTCERENCOILNY DC Frame G 110 - 130V 190 - 240 V 190 - 240V 480 - 500V 380 - 440V 24 V 480 - 500V 380 - 440V 24V 42 - 48V 42 - 48V 200 - 240V 24 - 27V 48 - 60V Frame L 1) 110 - 250V 250 - 500V 250 - 500V 110 - 250V 48 - 110V 48 - 110V 250 - 500V 250 - 500V 48 - 110V 48 - 110V 110 - 250V 250 - 500V 48 - 110V 110 - 250V 250 - 500V 48 - 110V 24 - 48V 48 - 110V Frame M 1) 110 - 250V 24 - 48V 48 - 110V Frame N 1) C on tacto rs and O ver load R elays 1) 110 - 250V 48 - 110V Electronic modules including coils. Contactors, Frames D, L and M, Replacement Contact Kits Description Eaton list number Replacement Contact Kits for use with XTAE040D - XTAE065D Replacement Contact Kits for use with XTCE185L - XTCE250L Replacement Contact Kits for use with XTCE300M - XTCE500M XTCERENCONTACTD XTCERENCONTACTL XTCERENCONTACTM Contactors, Frames N, Replacement Vacuum Tube Assembly Description Eaton list number Replacement Vacuum Tube Assembly for use with XTCE580N Replacement Vacuum Tube Assembly for use with XTCE650N Replacement Vacuum Tube Assembly for use with XTCE750N Replacement Vacuum Tube Assembly for use with XTCE820N XTCERENVACT580 XTCERENVACT650 XTCERENVACT750 XTCERENVACT820 Contactors, Frames L - M, Replacement Arc Chambers 34 Contactors and Overload Relays Description Eaton list number Replacement Arc Chambers for use with XTCE185L Replacement Arc Chambers for use with XTCE225L Replacement Arc Chambers for use with XTCE250L Replacement Arc Chambers for use with XTCE300M Replacement Arc Chambers for use with XTCE400M Replacement Arc Chambers for use with XTCE500M XTCERENARC185 XTCERENARC225 XTCERENARC250 XTCERENARC300 XTCERENARC400 XTCERENARC500 PG03407001U - June 2006 Overload Relay, Frame B - Direct Mount Overload Setting I r Circuit Symbol (A) XTOB016BC1 0.1 - 16 0.16 - 0.24 0.24 - 0.4 0.4 - 0.6 0.6 - 1 1 - 1.6 1.6 - 2.4 2.4 - 4 4-6 6 - 10 9 - 12 12 - 16 97 95 2 4 6 98 96A214/ 22 97 95 2 4 6 98 96A214/ 22 97 95 2 4 6 98 96A214/ 22 Contact Configuration For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 CoordiCoordination, nation, gG/gL gG/gL 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 7 - 15A 7 - 15A 7 - 15A 7 - 15A 25 25 25 25 0.5 1 2 4 15 15 15 15 XTOBP16BC1 XTOBP24BC1 XTOBP40BC1 XTOBP60BC1 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 7 - 15A 7 - 15A 7 - 15A 7 - 15A 25 25 25 25 4 6 10 16 15 15 15 15 XTOB001BC1 XTOB1P6BC1 XTOB2P4BC1 XTOB004BC1 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 7 - 15A 7 - 15A 9 - 15A 12 - 15A 25 50 50 50 20 25 25 25 15 15 25 30 XTOB006BC1 XTOB010BC1 XTOB012BC1 XTOB016BC1 Circuit Breaker Eaton list number Overload Relay, Frame C - Direct Mount Circuit Symbol (A) XTOB032CC1 Contact Configuration For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 CoordiCoordination, nation, gG/gL gG/gL 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 18 - 32A 18 - 32A 18 - 32A 18 - 32A 25 25 25 25 0.5 1 2 4 25 25 25 25 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 25 - 32A 25 25 25 25 25 50 63 100 125 4 6 10 16 20 25 35 35 63 25 25 25 25 25 25 30 30 30 Circuit Breaker XTOBP16CC1 XTOBP24CC1 XTOBP40CC1 XTOBP60CC1 97 95 0.1 - 0.16 0.16 - 0.24 0.24 - 0.4 0.4 - 0.6 0.6 - 1 1 - 1.6 1.6 - 2.4 2.4 - 4 4-6 6 - 10 10 - 16 16 - 24 24 - 32 2 4 6 98 9614/ 22 97 95 2 4 6 98 9614/ 22 97 95 2 4 6 98 9614/ 22 Eaton list number XTOB001CC1 XTOB1P6CC1 XTOB2P4CC1 XTOB004CC1 XTOB006CC1 XTOB010CC1 XTOB016CC1 XTOB024CC1 XTOB032CC1 Overload Relay, Frame D - Direct Mount Overload Setting I r Circuit Symbol (A) XTOB065DC1 6 - 10 10 - 16 16 - 24 24 - 40 40 - 57 50 - 65 PG03407001U - June 2006 9795 2 4 6 9896 9795 2 4 6 9896 Contact Configuration For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 CoordiCoordination, nation, gG/gL gG/gL 1NO-1NC 1NO-1NC 1NO-1NC 40 - 65A 40 - 65A 40 - 65A 50 63 63 25 35 50 25 25 30 XTOB010DC1 XTOB016DC1 XTOB024DC1 1NO-1NC 1NO-1NC 1NO-1NC 40 - 65A 50 - 65A 65A 125 160 160 63 80 100 125 150 150 XTOB040DC1 XTOB057DC1 XTOB065DC1 Circuit Breaker Eaton list number Contactors and Overload Relays C on tacto rs and O ver load R elays Overload Setting I r 35 Overload Relay, Frame F - G - Direct Mount Overload Setting I r Circuit Symbol (A) XTOB150GC1 25 - 35 35 - 50 50 - 70 70 - 100 95 - 125 120 - 150 9795 2 4 6 9896 9795 2 4 6 9896 Contact Configuration For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 CoordiCoordination, nation, gG/gL gG/gL 1NO-1NC 1NO-1NC 1NO-1NC 80 - 150A 80- 150A 80 - 150A 125 160 250 100 125 160 125 150 150 XTOB035GC1 XTOB050GC1 XTOB070GC1 1NO-1NC 1NO-1NC 1NO-1NC 80 - 150A 80 - 150A 80 315 315 315 200 250 250 400 500 600 XTOB100GC1 XTOB125GC1 XTOB150GC1 Circuit Breaker Eaton list number Overload Relay, Frame F - G - Seperate Mount Overload Setting I r Circuit Symbol (A) XTOB150GC1S 25 - 35 35 - 50 50 - 70 C on tacto rs and O ver load R elays 70 - 100 95 - 125 120 - 150 9795 2 4 6 9896 9795 2 4 6 9896 Contact Configuration For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 CoordiCoordination, nation, gG/gL gG/gL 1NO-1NC 1NO-1NC 1NO-1NC 80 - 150A 80 - 150A 80 - 150A 125 160 250 100 125 160 125 150 150 XTOB035GC1S XTOB050GC1S XTOB070GC1S 1NO-1NC 1NO-1NC 1NO-1NC 80 - 150A 80 - 150A 80 315 315 315 200 250 250 400 500 600 XTOB100GC1S XTOB125GC1S XTOB150GC1S Contact Configuration For use with Contactor Amp Range Short-circuit protection (A) Type 2 Type 1 CoordiCoordination, nation, gG/gL gG/gL 1NO-1NC 1NO-1NC 1NO-1NC 185 - 250A 185 - 250A 185 - 250A 250 315 315 1NO-1NC 1NO-1NC 1NO-1NC 185 - 250A 185 - 250A 225 - 250A 400 Circuit Breaker Eaton list number Overload Relay, Frame L Overload Setting I r Circuit Symbol (A) XTOB250LC1 50 - 70 70 - 100 95 - 125 120 - 160 160 - 220 200 - 250 1) 1 3 5 97 95 2 4 6 98 96 1 3 5 97 95 2 4 6 98 96 400 160 200 250 250 1) 400 1) 315 1) 315 1) Circuit Breaker Eaton list number 150 400 500 XTOB070LC1 XTOB100LC1 XTOB125LC1 600 800 600 XTOB160LC1 XTOB220LC1 XTOB250LC1 For separate mounting, short circuit Type 1 rating is 500A and short circuit Type 2 rating is 400A. Overload Relay, Frame M - N Seperate Mount Current Transformer Operated1) * The main current parameters are defined by the main current wiring which is used. Overload Setting I r Circuit Symbol (A) Contact Configuration For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 CoordiCoordination, nation, gG/gL gG/gL 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 300 - 500A 300 - 500A 300 - 500A 300 - 500A -- -- -- -- -- -- -- -- 150 250 500 600 XTOT063C3S XTOT090C3S XTOT125C3S XTOT160C3S 1NO-1NC 1NO-1NC 1NO1-NC 1NO-1NC 300 - 500A 300 - 500A 300 - 500A 500A -- -- -- -- -- -- -- -- 600 600 1000 600 XTOT240C3S XTOT290C3S XTOT400C3S XTOT540C3S Circuit Breaker Eaton list number XTOT160C3S 42 - 63 60 - 90 85 - 125 110 - 160 160 - 240 190 - 290 270 - 400 360 - 540 36 Contactors and Overload Relays 97 95 98 96 97 95 98 96 PG03407001U - June 2006 Overload Relay, DIN Rail or Panel Mount Adapter, Frames C-D Description QPC Adaptor for use with XTOB. . .CC1 Adaptor for use with XTOB...DC1 5 1 Eaton list number XTOBXDINC XTOBXDIND XTOBXDIND Overload Relay, Terminal Shroud, Frame L, Seperate Mount Description Eaton list number Terminal Shroud for use with XTOB...LC1 XTOBXTSL XTOBXTSL Overload Relay, Terminal Shroud, Frame L, Direct Mount Eaton list number Terminal Shroud for use with XTOB...LC1 to XTCE185L, XTCE225L or XTCE250L XTOBXTSCL C on tacto rs and O ver load R elays Description XTOBXTSCL PG03407001U - June 2006 Contactors and Overload Relays 37 5 Starters DOL, DOL Reversing and Star Delta This chapter provides product selection guidance for Eaton's XT range of Starters, which includes DOL, DOL reversing and Star-delta configurations. Standards * IEC EN 60947 * CE Marked * UL * CSA * CCC * ATEX See page 41 for coil suffix selection. See page 42 for overload relay suffix selection. See page 103 for dimensional drawings. See page 106 for the technical details . Starter, DOL, Frame B I e (A) AC-3 S tar ter s XTAE007B10 7 7 9 9 12 12 15.5 15.5 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 20 20 20 20 20 20 20 20 220/ 230V 380/ 400V 415V 660/ 690V 1000V 2.2 2.2 2.5 2.5 3.5 3.5 4 4 3 3 4 4 5.5 5.5 7.5 7.5 4 4 5.5 5.5 7 7 8 8 3.5 3.5 4.5 4.5 6.5 6.5 7 7 -- -- -- -- -- -- -- -- Auxiliary Contacts Eaton list number 1)2) 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC XTAE007B10_ _ XTAE007B01_ _ XTAE009B10_ _ XTAE009B01_ _ XTAE012B10_ _ XTAE012B01_ _ XTAE015B10_ _ XTAE015B01_ _ Auxiliary Contacts Eaton list number 1)2) 1NO 1NC 1NO 1NC 1NO 1NC XTAE018C10_ _ XTAE018C01_ _ XTAE025C10_ _ XTAE025C01_ _ XTAE032C10_ _ XTAE032C01_ _ Auxiliary Contacts Eaton list number 1)2) -- -- -- XTAE040D00_ _ XTAE050D00_ _ XTAE065D00_ _ First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starter, DOL, Frame C I e (A) AC-3 XTAE018C10 18 18 25 25 32 32 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 35 35 40 40 40 40 220/ 230V 380/ 400V 415V 660/ 690V 1000V 5 5 7.5 7.5 10 10 7.5 7.5 11 11 15 15 10 10 14.5 14.5 18 18 11 11 14 14 17 17 -- -- -- -- -- -- First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starter, DOL, Frame D I e (A) AC-3 40 50 65 1) XTAE040D00 38 Starters 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 50 65 80 220/ 230V 380/ 400V 415V 660/ 690V 1000V 12.5 15.5 20 18.5 22 30 24 30 39 23 30 35 -- -- -- First underscore (_) indicates magnet coil suffix required. Second underscore (_) indicates overload relay suffix required. PG03407001U - June 2006 Starter, DOL, Frame F I e (A) AC-3 80 95 1) 2) XTAE080F00 Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 90 110 220/ 230V 380/ 400V 415V 660/ 690V 1000V 25 30 37 45 48 57 63 75 45 55 Auxiliary Contacts Eaton list number 1)2) -- -- XTAE080F00_ _ XTAE095F00_ _ Auxiliary Contacts Eaton list number 1)2) -- -- XTAE115G00_ _ XTAE150G00_ _ Auxiliary Contacts Eaton list number 1)2) 2NO-2NC 2NO-2NC 2NO-2NC XTAE185L22_ _ XTAE225L22_ _ XTAE250L22_ _ Auxiliary Contacts Eaton list number 1)2) 2NO-2NC 2NO-2NC 2NO-2NC XTAE300M22_ _ XTAE400M22_ _ XTAE500M22_ _ Auxiliary Contacts Eaton list number 1)2) 2NO-2NC 2NO-2NC XTAE580N22_ _ XTAE650N22_ _ First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starter, DOL, Frame G I e (A) AC-3 115 150 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 130 160 220/ 230V 380/ 400V 415V 37 48 55 75 70 91 660/ 690V 90 96 1000V 66 80 First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. XTAE150G00 Starter, DOL, Frame L I e (A) AC-3 185 225 250 2) XTAE185L22 275 315 350 220/ 230V 380/ 400V 415V 660/ 690V 1000V 55 70 75 90 110 132 110 132 148 175 215 240 108 108 108 First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. S tar ter s 1) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 Starter, DOL, Frame M I e (A) AC-3 XTAE300M22 300 400 500 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 400 500 700 220/ 230V 380/ 400V 415V 660/ 690V 1000V 90 125 155 160 200 250 180 240 300 286 344 344 132 132 132 First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starter, DOL, Frame N I e (A) AC-3 580 650 XTAE580N22 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz AC-1 800 850 220/ 230V 380/ 400V 415V 660/ 690V 1000V 185 205 315 355 348 390 560 630 600 600 First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. PG03407001U - June 2006 Starters 39 Starters, DOL Reversing, Frame B I e (A) AC-3 XTAR007B1 7 9 12 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz Eaton list number 1)2) 220/ 230V 380/ 400V 415V 660/ 690V 2.2 2.5 3.5 3 4 5.5 4 5.5 7 3.5 4.5 6.5 XTAR007B21_ _ XTAR009B21_ _ XTAR012B21_ _ First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starters, DOL Reversing, Frame C I e (A) AC-3 XTAR018C21 18 25 32 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz Eaton list number 1)2) 220/ 230V 380/ 400V 415V 660/ 690V 5 7.5 10 7.5 11 15 8 14.5 18 11 14 17 XTAR018C21_ _ XTAR025C21_ _ XTAR032C21_ _ First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starters, DOL Reversing, Frame D I e (A) AC-3 XTAR040D11 40 50 65 1) S tar ter s 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz 220/ 230V 380/ 400V 415V 12.5 15.5 20 18.5 22 30 24 30 39 Eaton list number 1)2) 660/ 690V 23 30 35 XTAR040D11_ _ XTAR050D11_ _ XTAR065D11_ _ First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starters, DOL Reversing, Frame F I e (A) AC-3 80 95 1) XTAR080F11 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz Eaton list number 1)2) 220/ 230V 380/ 400V 415V 660/ 690V 25 30 37 45 48 57 63 75 XTAR080F11_ _ XTAR095F11_ _ First underscore (_) indicates coil suffix required. Second underscore (_) indicates overload relay suffix required. Starters, DOL Reversing, Frame G I e (A) AC-3 115 150 XTAR115G11 40 Starters 1) 2) Maximum kW Ratings AC-3, 3-Phase Motors 50 - 60 Hz Eaton list number 1)2) 220/ 230V 380/ 400V 415V 660/ 690V 37 48 55 75 7 91 105 125 XTAR115G11_ _ XTAR150G11_ _ Underscore (_) indicates coil suffix required. Underscore (_) indicates overload relay suffix required. PG03407001U - June 2006 Coil Suffix Frame A - B 110V 220V 230V 24V 415V 550V 190V 240V 380V 400V 12V 24V 42V 48V Frame C - F 110V 220V 230V 24V 415V 550V 190V 240V 380V 400V 12V 24V 42V 48V Frame G 100 - 120V 190 - 240V 24V 480 - 500V 380 - 440V 42 - 48V Frame L - M 110 - 250V 250 - 500V 48 - 110V 60Hz DC Suffix Code 120V 220V 12V 24V 48V A B F T C D E G H L N P R U W Y AD 1) BD 1) RD 1) TD 1) WD 1) 120V 240V 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V 120V 240V A B F T C D E G H L N P R U W Y 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V 60 Hz 110 - 130V AD 1) 200 - 240V BD 1) 12 - 14V RD 1) 24 - 27V TD 1) 48 - 60V WD 1) 100 - 120V 190 - 240V 24V 480 - 500V 380 - 440V 42 - 48V 110 - 250V 250 - 500V 48 - 110V S tar ter s Coil Voltage 50Hz A B T C L W 24 - 27V TD 1) 110 - 130V AD 1) 200 - 240V BD 1) 48 - 60V WD 1) 110 - 250V A C 48 - 110V Y 1) 24 - 48V TD 1) 1) With DC operation: Integrated diode-resistor combination, coil rating 2.6W. PG03407001U - June 2006 Starters 41 Starters, DOL and DOL Reversing, Overload Relay Suffix Selection Frame Size Motor Full Load Amperes For use with Contactor Amp Range Overload Relay Supplied Suffix Code 0.1 - 0.16 0.16 - 0.24 0.24 - 0.4 0.4 - 0.6 0.6 - 1 1 - 1.6 1.6 - 2.4 2.4 - 4 4-6 6 - 10 9 - 12 12 - 16 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 9 - 15A 12 - 15A XTOBP16BC1 XTOBP24BC1 XTOBP40BC1 XTOBP60BC1 XTOB001BC1 XTOB1P6BC1 XTOB2P4BC1 XTOB004BC1 XTOB006BC1 XTOB009BC1 XTOB012BC1 XTOB016BC1 P16 P24 P40 P60 001 1P6 2P4 004 006 010 012 016 0.1 - 0.16 0.16 - 0.24 0.24 - 0.4 0.4 - 0.6 0.6 - 1 1 - 1.6 1.6 - 2.4 2.4 - 4 4-6 6 - 10 10 - 16 16 - 24 24 - 32 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 25 - 32A XTOBP16CC1 XTOBP24CC1 XTOBP40CC1 XTOBP60CC1 XTOB001CC1 XTOB1P6CC1 XTOB2P4CC1 XTOB004CC1 XTOB006CC1 XTOB010CC1 XTOB016CC1 XTOB024CC1 XTOB032CC1 P16 P24 P40 P60 001 1P6 2P4 004 006 010 016 024 032 XTOB010DC1 XTOB016DC1 XTOB024DC1 XTOB040DC1 XTOB057DC1 XTOB065DC1 010 016 024 040 057 065 Frame B Frame C S tar ter s Frame D 6 - 10 10 - 16 16 - 24 24 - 40 40 - 57 50 - 65 40 - 65A 40 - 65A 40 - 65A 40 - 65A 50 - 65A 65A 25 - 35 35 - 50 50 - 70 70 - 100 80 - 95A 80 - 95A 80 - 95A 80 - 95A 25 - 35 35 - 50 50 - 70 115 - 150A 115 - 150A 115 - 150A 70 - 100 95 - 125 120 - 150 115 - 150A 115 - 150A 150A 50 - 70 70 - 100 95 - 125 120 - 160 160 - 220 200 - 250 185 - 250A 185 - 250A 185 - 250A 185 - 250A 185 - 250A 225 - 250A XTOB070LC1 XTOB100LC1 XTOB125LC1 XTOB160LC1 XTOB220LC1 XTOB250LC1 070 100 125 160 220 250 42 - 63 60 - 90 85 - 125 110 - 160 160 - 240 190 - 290 270 - 400 360 - 540 300 - 500A 300 - 500A 300 - 500A 300 - 500A 300 - 500A 300 - 500A 300 - 500A 500A XTOT063C3S XTOT090C3S XTOT125C3S XTOT160C3S XTOT240C3S XTOT290C3S XTOT400C3S XTOT540C3S 063 090 125 160 240 290 400 540 Frame F XTOB055GC1 1) XTOB050GC1 1) XTOB070GC1 1) XTOB100GC1 1) 035 050 070 100 Frame G XTOB055GC1 1) XTOB050GC1 1) XTOB070GC1 1) XTOB100GC1 1) XTOB125GC1 1) XTOB150GC1 1) 035 050 070 100 125 150 Frame L Frame M 42 Starters PG03407001U - June 2006 Starters, DOL and DOL Reversing, Overload Relay Suffix Selection (Continued) Frame Size Motor Full Load Amperes For use with Contactor Amp Range Overload Relay Supplied Suffix Code 42 - 63 60 - 90 85 - 125 110 - 160 160 - 240 190 - 290 270 - 400 360 - 540 420 - 630 580 - 650A 580 - 650A 580 - 650A 580 - 650A 580 - 650A 580 - 650A 580 - 650A 580 - 650A 580 - 650A XTOT063C3S XTOT090C3S XTOT125C3S XTOT160C3S XTOT240C3S XTOT290C3S XTOT400C3S XTOT540C3S XTOT630C3S 063 090 125 160 240 290 400 540 630 Frame N Eaton list number refers to direct mount overload relay. Add an S to the end of the Eaton list number for separate mount. S tar ter s 1) PG03407001U - June 2006 Starters 43 Starters, Star Delta, Frame B, Parts List I e (A) AC-3 660/ 690V Maximum Changeover Time (sec) Component Descriptions Quantity Required Eaton list number 1) K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link 1 1 1 1 1 3 1 1 1 1 1 1 3 1 1 1 1 1 3 1 XTCE007B10_ XTCE007B01_ XTCE007B01_ XTTR6A60S51B XTOB...BC1 XTCEXFAC20 XTCEXSDLB XTCE009B10_ XTCE009B01_ XTCE009B01_ XTTR6A60S51B XTOB...BC1 XTCEXFAC20 XTCEXSDLB XTCE012B10_ XTCE012B01_ XTCE012B01_ XTTR6A60S51B XTOB...BC1 XTCEXFAC20 XTCEXSDLB Maximum Changeover Time (sec) Component Descriptions Quantity Required Eaton list number 1) K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay (2) Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay (2) Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay (2) Auxiliary Contacts Star Delta Link 1 1 1 1 1 3 1 1 1 1 1 1 3 1 1 1 1 1 1 3 1 XTCE018C10_ XTCE018C01_ XTCE018C01_ XTTR6A60S51B XTOB...CC1 XTCEXFAC20 XTCEXSDLC XTCE025C10_ XTCE025C01_ XTCE025C01_ XTTR6A60S51B XTOB...CC1 XTCEXFAC20 XTCEXSDLC XTCE032C10_ XTCE032C01_ XTCE032C01_ XTTR6A60S51B XTOB...CC1 XTCEXFAC20 XTCEXSDLC 12 3 5.5 7 5.5 5.5 < 20 16 4 7.5 8 7.5 7.5 < 20 22 1) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 5.5 11 14.5 11 11 < 20 Underscore (_) indicates coil suffix required. See page 48. Starters, Star Delta, Frame C, Parts List S tar ter s I e (A) AC-3 30 1) 44 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 7.5 660/ 690V 15 19 18.5 18.5 < 20 45 11 22 30 30 22 < 20 55 15 30 39 37 30 < 20 Underscore (_) indicates coil suffix required. See page 48. Contactors, Overload Relays and Starters PG03407001U - June 2006 Starters, Star Delta, Frame D, Parts List I e (A) AC-3 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 660/ 690V 70 18.5 37 37 45 90 22 45 45 115 30 55 55 1) Maximum Changeover Time (sec) Component Descriptions Quantity Required Eaton list number 1) 37 < 20 55 45 < 20 75 55 < 20 K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 XTCE040D10_ XTCE040D00_ XTCE040D00_ XTTR6A60S51B XTOB...DC1 XTCEXFBG11 XTCEXSDLD XTCE050D10_ XTCE050D00_ XTCE040D00_ XTTR6A60S51B XTOB...DC1 XTCEXFBG11 XTCEXSDLD XTCE065D10_ XTCE065D00_ XTCE040D00_ XTTR6A60S51B XTOB...DC1 XTCEXFBG11 XTCEXSDLD Component Descriptions Quantity Required Eaton list number 1) K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link 1 1 1 1 1 2 1 1 1 1 1 2 1 XTCE080F10_ XTCE080F00_ XTCE050D00_ XTTR6A60S51B XTOB...FC1 XTCEXFBG11 XTCEXSDLF XTCE095F10_ XTCE095F00_ XTCE065D00_ XTTR6A60S51B XTOB...FC1 XTCEXFBG11 XTCEXSDLF Component Descriptions Quantity Required Eaton list number 1) Underscore (_) indicates coil suffix required. See page 48. I e (A) AC-3 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 660/ 690V Maximum Changeover Time (sec) 140 37 75 75 90 90 < 20 165 45 90 110 110 132 < 20 1) S tar ter s Starters, Star Delta, Frame F, Parts List Underscore (_) indicates coil suffix required. See page 48. Starters, Star Delta, Frame G, Parts List I e (A) AC-3 1) Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 660/ 690V Maximum Changeover Time (sec) 200 55 110 132 132 160 < 20 260 75 132 148 160 160 < 20 K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor K1T Timing Relay Overload Relay Auxiliary Contacts Star Delta Link 1 1 1 1 1 2 1 1 1 1 1 1 2 1 XTCE115G10_ XTCE115G00_ XTCE080F00_ XTTR6A60S51B XTOB...GC1 XTCEXFBG11 XTCEXSDLG XTCE150G10_ XTCE150G00_ XTCE080F00_ XTTR6A60S51B XTOB...GC1 XTCEXFBG11 XTCEXSDLG Underscore (_) indicates coil suffix required. See page 48. PG03407001U - June 2006 Starters 45 Starters, Star Delta, Frame L, Parts List I e (A) AC-3 315 385 430 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 90 110 132 160 200 250 180 240 300 200 250 315 660/ 690V 250 315 400 Maximum Changeover 1000V Time (sec) 132 <30 160 <20 200 <30 Component Descriptions Quantity Required Eaton list number 1) K1M Main Contactor K5M Delta Contactor 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 XTCE185L22_ XTCE185L22_ XTCE115G00_ XTTR6A60S51B XTOB...LC1 XTCEXFBG22 XTCEXSDLL250 XTCE225L22_ XTCE225L22_ XTCE150G00_ XTTR6A60S51B XTOB...LC1 XTCEXFBG22 XTCEXSDLL250 XTCE250L22_ XTCE250L22_ XTCE185L22_ XTTR6A60S51B XTOB...LC1 XTCEXSDLL250 K3M Star Contactor 2) K1T Timing Relay Overload Relay K3M Auxiliary Contact Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay Overload Relay K3M Auxiliary Contact Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay Overload Relay Star Delta Link 1) 2) Underscore (_) indicates magnet coil suffix required. See page 48. If mechanical interlock of the star contactor is required, star contactor must be the same frame size as main and delta contactors. Starters, Star Delta, Frame M, Parts List I e (A) AC-3 S tar ter s 515 685 860 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 160 200 250 300 355 450 348 390 500 355 450 560 660/ 690V 450 560 600 Maximum Changeover 1000V Time (sec) 200 <30 220 <20 220 <30 Component Descriptions Quantity Required Eaton list number 1) K1M Main Contactor K5M Delta Contactor 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 XTCE300M22_ XTCE300M22_ XTCE185L00_ XTTR6A60S51B XTOT...C3S XTCEXSDLM400 XTCE400M22_ XTCE400M22_ XTCE250L00_ XTTR6A60S51B XTOT...C3S XTCEXSDLM400 XTCE500M22_ XTCE500M22_ XTCE300M00_ XTTR6A60S51B XTOT...C3S XTCEXSDLM400 K3M Star Contactor 2) K1T Timing Relay Overload Relay Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay Overload Relay Star Delta Link K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay Overload Relay Star Delta Link 1) 2) 46 Underscore (_) indicates magnet coil suffix required. See page 48. If mechanical interlock of the star contactor is required, star contactor must be the same frame size as main and delta contactors. Contactors, Overload Relays and Starters PG03407001U - June 2006 Starters, Star Delta, Frame N, Parts List I e (A) AC-3 1000 Maximum kW Ratings AC-3 3-Phase Motors 50 - 60 Hz 220/ 380/ 415V 500V 230V 400V 300 560 610 710 660/ 690V 900 Maximum Changeover 1000V Time (sec) 355 <30 Component Descriptions Quantity Required Eaton list number 1)3) K1M Main Contactor K5M Delta Contactor 1 1 1 1 1 XTCE580N22_ XTCE580N22_ XTCE400M00_ XTTR6A60S51B K3M Star Contactor 2) K1T Timing Relay 1120 350 630 680 750 950 355 <30 Overload Relay K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay 1290 400 710 760 900 1200 1400 <30 Overload Relay K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay 1400 450 800 850 950 1300 1400 <30 Overload Relay K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay 1700 560 1000 1050 1200 1700 1700 <20 Overload Relay K1M Main Contactor K5M Delta Contactor K3M Star Contactor 2) K1T Timing Relay Overload Relay 1) 2) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 XTOT...C3S3) XTCE750N22_ XTCE750N22_ XTCE580N00_ XTTR6A60S51B XTOT...C3S3) XTCE820N22_ XTCE820N22_ XTCE580N00_ XTTR6A60S51B XTOT...C3S3) XTCEC10N22_ XTCEC10N22_ XTCE650N00_ XTTR6A60S51B XTOT...C3S3) Underscore (_) indicates magnet coil suffix required. See page 48. If mechanical interlock of the star contactor is required, star contactor must be the same frame size as main and delta contactors. Select/ complete Eaton List number for overload relay for (...) from page 48. S tar ter s 3) 1 1 1 1 1 XTOT...C3S3) XTCE650N22_ XTCE650N22_ XTCE400M00_ XTTR6A60S51B PG03407001U - June 2006 Starters 47 Coil Suffix Coil Voltage 50Hz 60Hz Frame A - B 110V 220V 24V 240V 380V 120V 240V 24V 277V 440V Suffix Code1) Frame C - F 110V 220V 24V 240V 380V DC 48V 24V A B T H L WD 2) TD 24V 24 - 27V 48 - 60V A B T H L TD 2) TD 2) WD 2) 24 - 27V A B T L TD 2) 120V 240V 24V 277V 440V Frame G 100 - 120V 190 - 240V 24V 380 - 440V 100 - 120V 190 - 240V 24V 380 - 440V Frame L-N 110 - 250V 250 - 500V 48 - 110V 110 - 250V 250 - 500V 48 - 110V 110 - 250V A C Y 2) TD 2) 48 - 110V 24 - 48V 1) Add suffix in place of underscore (_) to Eaton List Number. S tar ter s 2) With DC Operation: Integrated diode-resistor combination, coil rating 2.6W. Overload Relay, Frame B - Direct Mount * Short circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. * Trip Class: 10A Overload Releases, I r Contact Configuration Circuit Symbol XTOB016BC1 0.1 - 16A 0.16 - 0.24A 0.24 - 0.4A 0.4 - 0.6A 0.6 - 1A 1 - 1.6A 1.6 - 2.4A 2.4 - 4A 4 - 6A 6 - 10A 9 - 12A 12 - 16 48 Contactors, Overload Relays and Starters 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 97 95 2 4 6 98 96A214/ 22 97 95 2 4 6 98 96A214/ 22 97 95 2 4 6 98 96A214/ 22 For use with Contactor Amp Range 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 7 - 15A 12 - 15A 15A Short-circuit protection (A) Type 2 Circuit Type 1 CoordiCoordiBreaker nation, nation, gG/gL gG/gL Eaton list number 25 25 25 25 25 25 25 25 25 50 50 -- XTOB P16 BC1 XTOB P24 BC1 XTOB P40 BC1 XTOB P60 BC1 XTOB 001 BC1 XTOB 1P6 BC1 XTOB 2P4 BC1 XTOB 004 BC1 XTOB 006 BC1 XTOB 010 BC1 XTOB 012 BC1 XTOB 016 BC1 0.5 1 2 4 4 6 10 16 20 25 25 -- 15 15 15 15 15 15 15 15 15 15 15 15 PG03407001U - June 2006 Overload Relay, Frame C - Direct Mount * Short circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. * Trip Class: 10A Overload Releases, I r Contact Configuration Circuit Symbol For use with Contactor Amp Range 97 95 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 18 - 32A 25 25 25 25 25 25 25 25 18 - 32A 18 - 32A 18 - 32A 18 - 32A 25 - 32A 25 50 63 100 125 XTOB032CC1 0.1 - 0.16 0.16 - 0.24 0.24 - 0.4 0.4 - 0.6 0.6 - 1 1 - 1.6 1.6 - 2.4 2.4 - 4 4-6 6 - 10 10 - 16 16 - 24 24 - 32 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 2 4 6 98 9614/ 22 97 95 2 4 6 98 9614/ 22 97 95 2 4 6 98 9614/ 22 Short-circuit protection (A) Type 1 Type 2 Circuit CoordiCoordiBreaker nation, nation, gG/gL gG/gL Eaton list number 0.5 1 2 4 4 6 10 16 25 25 25 25 25 25 25 25 XTOB P16 CC1 XTOB P24 CC1 XTOB P40 CC1 XTOB P60 CC1 XTOB 001 CC1 XTOB 1P6 CC1 XTOB 2P4 CC1 XTOB 004 CC1 20 25 35 35 63 25 25 30 30 30 XTOB 006 CC1 XTOB 010 CC1 XTOB 016 CC1 XTOB 024 CC1 XTOB 032 CC1 Overload Relay, Frame D - Direct Mount * Short circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. * Trip Class: 10A Contact Configuration Circuit Symbol XTOB065DC1 6 - 10 10 - 16 16 - 24 1NO-1NC 1NO-1NC 1NO-1NC 24 - 40 40 - 57 50 - 65 1NO-1NC 1NO-1NC 1NO-1NC 9795 2 4 6 9896 9795 2 4 6 9896 For use with Contactor Amp Range Short-circuit protection (A) Type 2 Circuit Type 1 CoordiCoordiBreaker nation, nation, gG/gL gG/gL 40 - 65A 40 - 65A 40 - 65A 50 63 63 25 35 50 25 25 30 40 - 65A 50 - 65A 65A 125 160 160 63 80 100 125 150 150 Eaton list number S tar ter s Overload Releases, I r XTOB 010 DC1 XTOB 016 DC1 XTOB 024 DC1 XTOB 040 DC1 XTOB 057 DC1 XTOB 065 DC1 Overload Relay, Frame F - G - Direct Mount * Short circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. * Trip Class: 10A Overload Releases, I r Contact Configuration Circuit Symbol XTOB150GC1 25 - 35 35 - 50 50 - 70 1NO-1NC 1NO-1NC 1NO-1NC 70 - 100 95 - 125 120 - 150 1NO-1NC 1NO-1NC 1NO-1NC PG03407001U - June 2006 9795 2 4 6 9896 9795 2 4 6 9896 For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 Circuit CoordiCoordiBreaker nation, nation, gG/gL gG/gL Eaton list number 115 - 150A 125 115 - 150A 160 115 - 150A 250 100 125 160 125 150 150 XTOB 035 GC1 XTOB 050 GC1 XTOB 070 GC1 115 - 150A 315 115 - 150A 315 150A 315 200 250 250 400 500 600 XTOB 100 GC1 XTOB 125 GC1 XTOB 150 GC1 Starters 49 Overload Relay, Frame F - G - Seperate Mount * Short circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. * Trip Class: 10A Overload Releases, I r Contact Configuration Circuit Symbol XTOB150GC1S 25 - 35 35 - 50 50 - 70 1NO-1NC 1NO-1NC 1NO-1NC 70 - 100 95 - 125 120 - 150 1NO-1NC 1NO-1NC 1NO-1NC 9795 2 4 6 9896 9795 2 4 6 9896 For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 Circuit CoordiCoordiBreaker nation, nation, gG/gL gG/gL Eaton list number 115 - 150A 125 115 - 150A 160 115 - 150A 250 100 125 160 125 150 150 XTOB 035 GC1S XTOB 050 GC1S XTOB 070 GC1S 115 - 150A 315 115 - 150A 315 150A 315 200 250 250 400 500 600 XTOB 100 GC1S XTOB 125 GC1S XTOB 150 GC1S Overload Relay, Frame L * Short circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. * Trip Class: 10A * For separate mounting, short circuit Type 1 rating is 500A and short circuit Type 2 rating is 400A. S tar ter s XTOB250LC1 Overload Releases, I r Contact Configuration 50 - 70 70 - 100 95 - 125 1NO-1NC 1NO-1NC 1NO-1NC 120 - 160 160 - 220 200 - 250 1NO-1NC 1NO-1NC 1NO-1NC Circuit Symbol 1 3 5 97 95 2 4 6 98 96 1 3 5 97 95 2 4 6 98 96 For use with Contactor Amp Range Short-circuit protection (A) Type 2 Circuit Type 1 CoordiCoordiBreaker nation, nation, gG/gL gG/gL Eaton list number 185 - 250A 250 185 - 250A 315 185 - 250A 315 160 200 250 150 400 500 XTOB 070 LC1 XTOB 100 LC1 XTOB 125 LC1 185 - 250A 400 185 - 250A 400 225 - 250A 400 250 600 800 600 XTOB 160 LC1 XTOB 220 LC1 XTOB 250 LC1 315 31 Overload Relay, Current Transformer Operated, Frame M - N Seperate Mount * The main current parameters are defined by the main current wiring which is used. Overload Releases, I r Contact Configuration 42 - 63 60 - 90 85 - 125 110 - 160 160 - 240 190 - 290 270 - 400 360 - 540 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO1-NC 1NO-1NC Circuit Symbol For use with Contactor Amp Range Short-circuit protection (A) Type 1 Type 2 Circuit CoordiCoordiBreaker nation, nation, gG/gL gG/gL Eaton list number 300 - 500A 300 - 500A 300 - 500A 300 - 500A 300 - 500A 300 - 500A 300 - 500A 500A -- -- -- -- -- -- -- -- XTOT 063 C3S XTOT 090 C3S XTOT 125 C3S XTOT 160 C3S XTOT 240 C3S XTOT 290 C3S XTOT 400 C3S XTOT 540 C3S XTOT160C3S 50 Contactors, Overload Relays and Starters 97 95 98 96 97 95 98 96 -- -- -- -- -- -- -- -- 150 250 500 600 600 600 1000 600 PG03407001U - June 2006 6 Manual Motor Protectors This chapter provides product selection guidance for Eaton's XT range of Manual Motor Protectors (MMP's) which features a pushbutton or rotary On/Off manual disconnect, Class 10 adjustable bimetallic overload relay and fixed magnetic short circuit trip capability in one compact unit. The XTPB and XTPR MMP's can also be wired in series with a magnetic contactor to complete the assembly of a remotely operated, manual motor controller. Standards * IEC EN 60947-4-1 * CE Marked See page 56 for Accessories. See page 136 for dimensional drawings. See page 148 for the technical details. When ordering, specify Eaton list numbers according to the following stipulations: XT Manual Motor Protectors are selected based on the overload current range required for a given motor. This current range is determined from the motor Full Load Ampere rating and Motor Service Factor usually found on the motor nameplate. Manual Motor Protectors, Pushbutton, Frame B, Screw Terminal * Type 1 and Type 2 Coordination * Motor Protective Device with Thermal and Magnetic Trip * Select Manual Motor Protectors by full load current. Maximum Motor Ratings (kW) are for reference only. Rated Uninterrupted Current -- Iu = Ie (Amps) FLA Adjustment Range / Overload Release -- Ir (Amps) Short Circuit Release -- Irm (Amps) Maximum Motor Ratings Maximum kW Rating AC-3 -- P (kW) 3-Phase 220 - 380 - 440V 240V 415V 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 12 16 20 25 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 8 - 12 10 - 16 16 - 20 20 - 25 2.2 3.5 5.6 8.8 14 22 35 56 88 140 168 224 280 350 -- -- 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 5.5 PG03407001U - June 2006 -- 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 4 5.5 7.5 9 12.5 -- 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 5.5 9 11 12.5 Eaton list number 500V 660 - 690V -- 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 9 12.5 15 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 7.5 11 12.5 15 22 XTPBP16BC1 XTPBP25BC1 XTPBP40BC1 XTPBP63BC1 XTPB001BC1 XTPB1P6BC1 XTPB2P5BC1 XTPB004BC1 XTPB6P3BC1 XTPB010BC1 XTPB012BC1 XTPB016BC1 XTPB020BC1 XTPB025BC1 Manual Motor Protectors Manu al Mo to r Pr otector s XTPB025BC1 51 Manual Motor Protectors, Rotary, Frame B, Screw Terminals * Type 1 and Type 2 Coordination * Motor Protective Device with Thermal and Magnetic Trip. * Select Manual Motor Protectors by full load current. Maximum Motor Ratings (kW) are for reference only. XTPR032BC1 Rated Uninterrupted Current -- Iu = Ie (Amps) FLA Adjustment Range / Overload Release -- Ir (Amps) Short Circuit Release -- Irm (Amps) Maximum Motor Ratings Maximum kW Rating AC-3 -- P (kW) 3-Phase 220 - 380 - 440V 240V 415V 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 12 16 20 25 32 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 8 - 12 10 - 16 16 - 20 20 - 25 25 - 32 2.2 3.5 5.6 8.8 14 22 35 56 88 140 168 224 280 350 448 -- -- 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 5.5 7.5 -- 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 4 5.5 7.5 9 12.5 15 -- 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 5.5 9 11 12.5 15 Eaton list number 500V 660 - 690V -- 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 9 12.5 15 22 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 7.5 11 12.5 15 22 30 XTPRP16BC1 XTPRP25BC1 XTPRP40BC1 XTPRP63BC1 XTPR001BC1 XTPR1P6BC1 XTPR2P5BC1 XTPR004BC1 XTPR6P3BC1 XTPR010BC1 XTPR012BC1 XTPR016BC1 XTPR020BC1 XTPR025BC1 XTPR032BC1 Manual Motor Protectors, Rotary, Frame D, Screw Terminals * Type 1 and Type 2 Coordination * Motor Protective Device with Thermal and Magnetic Trip. * Select Manual Motor Protectors by full load current. Maximum Motor Ratings (kW) are for reference only. Manu al Mo to r Pr otector s XTPR063DC1 52 Manual Motor Protectors Rated Uninterrupted Current -- Iu = Ie (Amps) FLA Adjustment Range / Overload Release -- Ir (Amps) Short Circuit Release -- Irm (Amps) Maximum Motor Ratings Maximum kW Rating AC-3 -- P (kW) 3-Phase 220 - 380 - 440V 240V 415V 16 25 32 40 50 58 65 10 - 16 16 - 25 25 - 32 32 - 40 40 - 50 50 - 58 55 - 63 224 350 448 560 700 812 882 4 5.5 7.5 11 14 17 18.5 7.5 12.5 15 20 25 30 34 9 12.5 17.5 22 30 37 37 Eaton list number 500V 660 - 690V 9 12.5 17.5 22 30 37 37 12.5 22 22 30 45 55 55 XTPR016DC1 XTPR025DC1 XTPR032DC1 XTPR040DC1 XTPR050DC1 XTPR058DC1 XTPR063DC1 PG03407001U - June 2006 Manual Motor Protectors, Rotary, Frame B, Screw (Line) & Spring Cage (Load) Terminals * Type 1 and Type 2 Coordination * Motor Protective Device with Thermal and Magnetic Trip. * Select Manual Motor Protectors by full load current. Maximum Motor Ratings (kW) are for reference only. XTPRSC016BC1 Rated Uninterrupted Current -- Iu = Ie (Amps) 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 12 16 FLA Adjustment Range / Overload Release -- Ir (Amps) Short Circuit Release -- Irm (Amps) 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 8 - 12 10 - 16 2.2 3.5 5.6 8.8 14 22 35 56 88 140 168 224 Eaton list number Maximum Motor Ratings Maximum kW Rating AC-3 -- P (kW) 3-Phase 220 - 380 - 240V 415V -- -- 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 3 4 -- 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 4 5.5 7.5 440V 500V 660 - 690V -- 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 5.5 9 -- 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 9 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 7.5 11 12.5 XTPRSCP16BC1 XTPRSCP25BC1 XTPRSCP40BC1 XTPRSCP63BC1 XTPRSC001BC1 XTPRSC1P6BC1 XTPRSC2P5BC1 XTPRSC004BC1 XTPRSC6P3BC1 XTPRSC010BC1 XTPRSC012BC1 XTPRSC016BC1 Manual Motor Protectors, Rotary, Frame B, Spring Cage Terminals * Type 1 and Type 2 Coordination * Motor Protective Device with Thermal and Magnetic Trip. * Select Manual Motor Protectors by full load current. Maximum Motor Ratings (kW) are for reference only. Rated Uninterrupted Current -- Iu = Ie (Amps) Frame B 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 12 16 PG03407001U - June 2006 FLA Adjustment Range / Overload Release -- Ir (Amps) Short Circuit Release -- Irm (Amps) 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 8 - 12 10 - 16 2.2 3.5 5.6 8.8 14 22 35 56 88 140 168 224 Eaton list number Maximum Motor Ratings Maximum kW Rating AC-3 -- P (kW) 3-Phase 220 - 380 - 240V 415V -- -- 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 3 4 -- 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 4 5.5 7.5 440V 500V 660 - 690V -- 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 5.5 9 -- 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 9 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 7.5 11 12.5 XTPRCP16BC1 XTPRCP25BC1 XTPRCP40BC1 XTPRCP63BC1 XTPRC001BC1 XTPRC1P6BC1 XTPRC2P5BC1 XTPRC004BC1 XTPRC6P3BC1 XTPRC010BC1 XTPRC012BC1 XTPRC016BC1 Manual Motor Protectors Manu al Mo to r Pr otector s XTPRC016BC1 53 Manual Motor Protectors, Rotary, Frame B, Transformer Protective Circuit Breakers, Spring Cage Terminal * Type 1 and Type 2 Coordination * Motor Protective Device with Thermal and Magnetic Trip. * Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW,) are for reference only. XTPRC016BC1 Rated Uninterrupted Current -- Iu = Ie (Amps) Short Circuit Release -- Irm (Amps) 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 8 - 12 10 - 16 16 - 20 20 - 25 2.4 4.25 6.8 11.97 20 32 50 84 141 224 224 358 380 420 Eaton list number Maximum Motor Ratings Maximum kW Rating AC-3 -- P (kW) 3-Phase 220 - 380 - 240V 415V -- -- 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 5.5 -- 0.06 0.09 0.12 0.25 0.55 0.75 1.5 2.2 4 5.5 7.5 9 12.5 440V 500V 660 - 690V -- 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 5.5 9 11 12.5 -- 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 9 12.5 15 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 7.5 11 12.5 15 15 XTPRCP16BC1 XTPRCP25BC1 XTPRCP40BC1 XTPRCP63BC1 XTPRC001BC1 XTPRC1P6BC1 XTPRC2P5BC1 XTPRC004BC1 XTPRC6P3BC1 XTPRC010BC1 XTPRC012BC1 XTPRC016BC1 XTPRC020BC1 XTPRC025BC1 Manu al Mo to r Pr otector s 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 12 16 20 25 FLA Adjustment Range / Overload Release -- Ir (Amps) 54 Manual Motor Protectors PG03407001U - June 2006 Manual Motor Protectors, Rotary, Frame B, Magnetic Trip Only, Screw Terminal * Type 1 and Type 2 Coordination * Motor Protective Device Magnetic Trip. * Select Manual Motor Protectors by full load current. Maximum Motor Ratings (kW) are for reference only. * An appropriate overload relay must be fitted to protect motors against overload. Rated Uninterrupted Current -- Iu (Amps) 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 12 16 20 25 32 FLA Adjustment Range / Overload Release -- Ir (Amps) Short Circuit Release -- Irm (Amps) -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 2.2 3.5 5.6 8.8 14 22 35 56 88 140 168 224 280 350 448 Eaton list number Maximum Motor Ratings Maximum kW Rating AC-3 -- P (kW) 3-Phase 220 - 380 - 440V 240V 415V -- -- 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 5.5 7.5 -- 0.06 0.09 0.12 0.25 0.37 0.75 1.5 2.2 4 5.5 7.5 9 12.5 15 -- 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 5.5 9 11 12.5 15 500V 660 - 690V -- 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 9 12.5 15 22 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 7.5 11 12.5 15 22 30 XTPMP16B XTPMP25B XTPMP40B XTPMP63B XTPM001B XTPM1P6B XTPM2P5B XTPM004B XTPM6P3B XTPM010B XTPM012B XTPM016B XTPM020B XTPM025B XTPM032B Manu al Mo to r Pr otector s XTPM032B PG03407001U - June 2006 Manual Motor Protectors 55 Manual Motor Protectors, Side-mount Auxiliary Contacts * Can be fitted on the right side of manual motor protectors and manual transformer protectors and can be combined with XTPAXSATR... and XTPAXFA... trip indicating auxiliary contact. Contact Configuration Contact Sequence 1NO-1NC XTPAXSA11 Circuit Symbol 1.13 1.21 Terminals Screw Spring Cage QPC Eaton list number QPC Eaton list number 1 XTPAXSA11 5 XTPAXSAC11 1 XTPAXSA12 -- -- 1 XTPAXSA21 -- -- L1L2 L3 1.14 1.22 1NO-2NC 1.131.21 1.31 L1L2 L3 1.14 1.22 1.32 2NO-1NC 1.131.21 1.33 L1L2 L3 1.14 1.22 1.34 Manual Motor Protectors, Front-mount Auxiliary Contacts * Can be fitted to manual motor protectors and manual transformer protectors. 45 mm (XTPR...B and XTPB) or 55 mm (XTPR...D) widths of manual motor protectors remained unchanged. Contact Configuration XTPAXFA10 Contact Sequence 1NO-1NC Circuit Symbol 1.53 1.61 Terminals Screw Spring Cage QPC Eaton list number QPC 1 XTPAXFA11 -- -- 1 XTPAXFA10 5 XTPAXFAC10 -- -- 5 XTPAXFAC01 Eaton list number L1L2 L3 1.54 1.62 Manu al Mo to r Pr otector s 1NO-0NC 56 1.53 L1L2 L3 1.54 0NO-1NC 1.51 L1L2 L3 1.52 Manual Motor Protectors PG03407001U - June 2006 Manual Motor Protectors, Side-Mount Trip Indicating Auxiliary Contacts * Can be fitted on the right side of manual motor protectors. Can be combined with standard auxiliary contacts. Trip indication: A. General Trip indication (overload) B. Short-circuit trip. Local short-circuit indication by red indicator, manually resettable. Contact Configuration 2NO XTPAXSATR20 Contact Sequence Circuit Symbol On/Off "+" " " 4.43 4.13 L1L2 L3 "+" " >" Trip "+" 4.44 4.14 QPC Eaton list number 2 XTPAXSATR20 2 XTPAXSATR02 L1L2 L3 "+" " >" 2NC "+" " " 4.31 4.21 On/Off L1L2 L3 "+" " >" Trip "+" 4.32 4.22 L1L2 L3 "+" " >" Manual Motor Protectors, Early-Make Front-Mount Indicating Auxiliary Contacts * For use with XTPB..., B-Frame XTPR and XTPT. Can be fitted to the front of a manual motor protector. 45 mm width of manual motor protector remains unchanged. For early energization of undervoltage release, e.g. in Emergency-Stop circuits to EN 60204. Contact Configuration 2NO XTPBXFAEM20 Circuit Symbol 3.13 3.23 QPC Eaton list number 5 XTPBXFAEM20 2 XTPAXFAEM20 3.13 3.23 3.14 3.24 PG03407001U - June 2006 Manual Motor Protectors Manu al Mo to r Pr otector s 3.14 3.24 2NO 57 Manual Motor Protectors, Shunt Release * Can be fitted on the left side of manual motor protectors. Cannot be combined with the XTPAXUVR. DC: Intermittent operation 5 sec. Description XTPAXSR220V50H Shunt Trip 110V50H Shunt Trip 110VDC Shunt Trip 120V60H Shunt Trip 125VDC Circuit Symbol C1 QPC. Terminals Screw Spring Cage Eaton list number Eaton list number 2 2 2 2 XTPAXSR110V50H XTPAXSR110VDC XTPAXSR120V60H XTPAXSR125VDC -- -- -- -- 2 2 2 2 XTPAXSR208V60H XTPAXSR220V50H XTPAXSR220VDC XTPAXSR230V50H -- -- -- XTPAXSRC230V50H 2 2 2 2 XTPAXSR240V50H XTPAXSR240V60H XTPAXSR24V50H XTPAXSR24VDC -- -- -- XTPAXSRC24VDC 2 2 2 2 XTPAXSR250VDC XTPAXSR380V50H XTPAXSR400V50H XTPAXSR415V50H -- -- -- -- 2 2 2 2 2 XTPAXSR440V60H XTPAXSR480V60H XTPAXSR48V50H XTPAXSR48VDC XTPAXSR60VDC -- -- -- -- -- C2 Shunt Trip 208V60H Shunt Trip 220V50H Shunt Trip 220VDC Shunt Trip 230V50H C1 C2 Shunt Trip 240V50H Shunt Trip 240V60H Shunt Trip 24V50H Shunt Trip 24VDC C1 C2 Shunt Trip 250VDC Shunt Trip 380V50H Shunt Trip 400V50H Shunt Trip 415V50H C1 C2 Shunt Trip 440V60H Shunt Trip 480V60H Shunt Trip 48V50H Shunt Trip 48VDC Shunt Trip 60VDC C1 C2 Manual Motor Protectors, Undervoltage Release Manu al Mo to r Pr otector s * Can be fitted on left side manual motor protectors. Cannot be combined with XTPAXSR. When combined with a circuit breaker, it can be used as Emergency-Stop device to IEC/EN 60204. Description XTPAXUVR220V50H Undervoltage release 110V50H Undervoltage release 120V60H Undervoltage release 208V60H Undervoltage release 220V50H Circuit Symbol D1 U QPC. Terminals Screw Spring Cage Eaton list number Eaton list number 2 2 2 2 XTPAXUVR110V50H XTPAXUVR120V60H XTPAXUVR208V60H XTPAXUVR220V50H -- -- -- -- 2 2 2 2 XTPAXUVR230V50H XTPAXUVR240V50H XTPAXUVR240V60H XTPAXUVR24V50H XTPAXUVRC230V50H -- -- -- 2 2 2 2 XTPAXUVR24V60H XTPAXUVR380V50H XTPAXUVR400V50H XTPAXUVR415V50H -- -- -- -- 2 2 2 2 XTPAXUVR440V60H XTPAXUVR480V60H XTPAXUVR48V50H XTPAXUVR60V50H -- -- -- -- D2 Undervoltage release 230V50H Undervoltage release 240V50H Undervoltage release 240V60H Undervoltage release 24V50H D1 U D2 Undervoltage release 24V60H Undervoltage release 380V50H Undervoltage release 400V50H Undervoltage release 415V50H D1 U D2 Undervoltage release 440V60H Undervoltage release 480V60H Undervoltage release 48V50H Undervoltage release 60V50H D1 U D2 58 Manual Motor Protectors PG03407001U - June 2006 Manual Motor Protectors, Current Limiter * Max. rated operation voltage Ue = 690V, rated uninterrupted current Iu = 63A. Can be used for individual and group protection. For group protection and in combination with the XTPR...D, order additional XTPAXIT incoming terminal if required. Mounting next to or behind the manual motor protector. 16 - 63A XTPR...D: 100 kA/400V, 10 kA/690V. Description Circuit Symbol QPC. Eaton list number 1 XTPAXCL Description QPC Eaton list number 20.5 mm Metric Cable Gland 6 - 13 mm Wire 25.5 mm Metric Cable Gland 9 - 17 mm Wire 32.5 mm Metric Cable Gland 13 - 21 mm Wire 32.5 mm Metric Cable Gland 18 - 25 mm wire 20 20 10 10 XTPAXMCG20 XTPAXMCG25 XTPAXMCG32 XTPAXMCG32G To enhance the switching capacity of noninherently safe 16 - 25A Manual Motor Protectors to 150 kA/440V L T XTPAXCL Manual Motor Protectors, Enclosure, Cable Glands XTPAXMCG20 Manual Motor Protectors, Enclosure, IP65 Metric Diaphragm Grommet * With integral push-through diaphragm. Description QPC Eaton list number 20.5 mm Diaphragm Grommet 1 - 13 mm Wire 25.5 mm Diaphragm Grommet 1 - 18 mm Wire 32.5 mm Diaphragm Grommet 1 - 24 mm Wire 100 100 100 XTPAXMDG20 XTPAXMDG25 XTPAXMDG32 * Plug-in Connection shaft, XTPAXRHMSFT, can be cut to desired length for mounting depths of 100 - 240 mm. Carrier with extension shaft included. * With ON/OFF switch position and "+" (tripped), lockable with 3 padlocks, 4 - 8 mm hasp. XTPAXRHM165B Description QPC. Eaton list number Rotary Handle Mech IP65 Black -- For use as main switch to IEC/EN 60204 Rotary Handle Mech IP65 Red/Yellow -- For use as main switch with Emergency-Stop function to EN 60204 Rotary Handle Mech IP65 Black -- For use as main switch to EN 60204 in MCC power distribution systems and with B-Frame XTPR when installed rotated 90. 1 1 XTPAXRHM165B XTPAXRHM265RY 1 XTPAXRHM365B Manual Motor Protectors, Pushbutton & Rotary, Telescopic Mounting Adapter * With 45 mm top-hat rail to IEC/EN 60715 for compensation of the mounting depth of rear mounted devices in surface mounted enclosures. Stepless adjustment via scale from 75 - 115 mm. Description QPC Eaton list number Telescoping Adapter, 75 - 115 mm Depth, for use with XTPB and B-Frame XTPR MMPs 1 XTPAXTEA Manu al Mo to r Pr otector s Manual Motor Protectors, Rotary Handle Mechanism XTPAXTEA PG03407001U - June 2006 Manual Motor Protectors 59 Manual Motor Protectors, Rotary, Frame B, Sealing Wire Description QPC. Sealing Wire for B-Frame XTPR. To prevent tampering with the overload release 5 and the test function Eaton list number XTPAXSW XTPAXSW Manual Motor Protectors, Enclosure, Indicating Lights Description Colour Opertating voltage QPC. Eaton list number Indicating Light White White White Green Green Green Red Red Red 110 - 230V 230 - 240V 415 - 500V 110 - 230V 230 - 240V 415 - 500V 110 - 230V 230 - 240V 415 - 500V 10 10 10 10 10 5 10 10 5 XTPAXILWB XTPAXILWN XTPAXILWC XTPAXILGB XTPAXILGN XTPAXILGC XTPAXILRB XTPAXILRN XTPAXILRC Indicating Light XTPAXILGB Indicating Light Manual Motor Protectors, Pushbutton and Rotary, Frame B, Three-Phase Commoning Link * Protected against accidental contact. B-Frame short circuit proof Ue = 690V, Iu = 63A; D-Frame short circuit proof Ue = 690V, Iu = 128A. Manu al Mo to r Pr otector s XTPAXCLKA2 For use with... Qty. MMP Length of Link (mm) Unit Width (mm) QPC Eaton list number MMP with no side mounted auxiliaries or voltage releases 2 3 4 5 2 3 4 5 2 4 90 135 180 225 99 153 207 261 108 234 45 45 45 45 45 + 9 45 + 9 45 + 9 45 + 9 45 + 18 45 + 18 10 10 10 10 10 10 10 10 10 10 XTPAXCLKA2 XTPAXCLKA3 XTPAXCLKA4 XTPAXCLKA5 XTPAXCLKB2 XTPAXCLKB3 XTPAXCLKB4 XTPAXCLKB5 XTPAXCLKC2 XTPAXCLKC4 MMP with one auxiliary contact or trip-indicating auxiliary contact fitted on the right MMP with an auxiliary contact and trip-indicating auxiliary contact mounted on the right or a voltage release mounted on the left. Manual Motor Protectors, Pushbutton and Rotary, Frame D, Three-Phase Commoning Link * Protected against accidental contact. B-Frame short circuit proof Ue = 690V, Iu = 63A; D-Frame short circuit proof Ue = 690V, Iu = 128A. For use with... Qty. MMP Length of Link (mm) Unit Width (mm) QPC Eaton list number MMP with no side mounted auxiliaries or voltage releases 2 3 4 110 165 220 55 55 55 1 1 1 XTPAXCLKA2D XTPAXCLKA3D XTPAXCLKA4D QPC Eaton list number 20 XTPAXUTS 10 XTPAXUTSD XTPAXCLKA2D Manual Motor Protectors, Rotary Unused Terminals Shroud Description For use with... To cover unused terminals on three-phase commoning link. B-Frame XTPR To cover unused terminals on three-phase commoning link. D-Frame XTPR XTPAXUTS 60 Manual Motor Protectors PG03407001U - June 2006 Manual Motor Protectors, Rotary, Frame B, Incoming Terminal * For three-phase commoning link, protected against accidental contact, Ue = 690V, Iu = 63A; For conductor cross-sections: 2.5 - 25 mm2 stranded; 2.5 - 16 mm2 flexible with ferrules.# Description For use with... QPC Eaton list number Incoming Terminal B-Frame XTPR 5 XTPAXIT XTPAXIT Manual Motor Protectors, Pushbutton Frame B, Insulated Enclosures * Surface Mounting * Integrated terminal for PE(N) connection, two M25 cable entry knockouts at top and at bottom. Description XTPBXENCSEK65 Degree of Protection For Use With... Eaton list number Enclosure, with membrane actuation. IP40 IP65 XTPBXENCS40 XTPBXENCS65 Enclosure, lockable in OFF position. IP65 Enclosure, lockable in OFF position in combination with XTPBXFAEM20 Early Make front mount auxiliary contact Enclosure, with Emergency-Stop (E-Stop) pushbutton actuator Enclosure, with Emergency-Stop (E-Stop) pushbutton actuator, key release IP65 XTPB MMP Only or with: XTPAXFA..., XTPBXFAEM20, XTPAXSA..., XTPAXUVR..., XTPAXSR... XTPB MMP Only or with: XTPAXFA..., XTPAXUVR..., XTPAXSR..., XTPAXCL XTPB MMP Only or with: XTPAXFA..., XTPBXFAEM20, XTPAXUVR..., XTPAXSR..., XTPAXCL IP65 IP65 XTPBXENCSLO65 XTPBXENCSLE65 XTPBXENCSES65 XTPBXENCSEK65 Manual Motor Protectors, Frame B, Pushbutton Insulated Enclosures * Flush Mounting Description XTPBXENCF40 Degree of Protection For Use With... Eaton list number Enclosure, with membrane actuation Front IP40 Front IP55 XTPBXENCF40 XTPBXENCF55 Enclosure, lockable in OFF position Front IP55 XTPB Only or with: XTPAXFA..., XTPBXFAEM20, XTPAXSA..., XTPAXUVR..., XTPAXSR..., XTPAXCL XTPB Only or with: XTPAXFA..., XTPAXUVR..., XTPAXSR..., XTPAXCL XTPB Only or with: XTPAXFA..., XTPBXFAEM20, XTPAXUVR..., XTPAXSR..., XTPAXCL Enclosure, lockable in OFF position in Front IP55 combination with XTPBXFAEM20 Early Make front mount auxiliary contact Enclosure, , with Emergency-Stop (E-Stop) Front IP55 pushbutton actuator Enclosure, , with Emergency-Stop (E-Stop) Front IP55 pushbutton actuator, key release PG03407001U - June 2006 XTPBXENCFLO55 XTPBXENCFLE55 XTPBXENCFEK55 XTPBXENCFES55 Manual Motor Protectors Manu al Mo to r Pr otector s * Integrated terminal for PE(N) connection 61 Manual Motor Protectors, Rotary, Frame B, Pushbutton Insulated Enclosures * Surface Mounting XTPAXENCS41 Description Degree of Protection For Use With... Eaton list number Enclosure, cover with aperture dimensioned to accommodate front of MMP. IP40, when mounted turned through 90 to left/right Enclosure, with black/grey rotary handle Enclosure, with red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 60204 Enclosure, cover with aperture dimensioned to accommodate front of MMP. Enclosure, with black/gray rotary handle Enclosure, with red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 60204 IP41 with vertical mounting B-Frame XTPR Only or with: XTPAXFA..., XTPAXSA..., XTPAXSATR..., XTPAXUVR..., XTPAXSR..., XTPAXCL XTPAXENCS41 1) 1) 2) IP65 IP65 IP40 IP55 IP55 B-Frame XTPR Only or with: XTPAXSA..., XTPAXUVR..., XTPAXSR..., XTPAXCL B-Frame XTPR Only or with: XTPAXFA..., XTPAXSA..., XTPAXUVR..., XTPAXSR..., XTPAXCL XTPAXENCS65B 1) XTPAXENCS65RY 1) XTPAXENCS40 2) XTPAXENCS55B 2) XTPAXENCS55RY 2) M25 metric cable entry knock-out, top and bottom. Cable push-through membrane, top and bottom, in the back plate and as a control line entry. Includes N and PE terminals. Integrated terminal for PE(N) connection, two M25 cable entry knockouts at the top and bottom. Manual Motor Protectors, Rotary, Frame B, Insulated Enclosures * Early - Make Front Mount Auxiliary Contact Description Degree of Protection For Use With... Eaton list number Enclosure, with black/gray rotary handle Enclosure, with red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 60204 IP65 IP65 XTPAXENCSEM65B XTPAXENCSEM65RY Enclosure, with black/gray rotary handle Enclosure, with red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 60204 IP55 IP55 B-Frame XTPR and XTPAXFAEM20 only or with: XTPAXFA..., XTPAXSA..., XTPAXSATR..., XTPAXUVR..., XTPAXSR..., XTPAXCL B-Frame XTPR and XTPAXFAEM20 only or with: XTPAXFA..., XTPAXUVR..., XTPAXSR..., XTPAXCL Manu al Mo to r Pr otector s XTPAXENCSEM65B 62 XTPAXENCSEM55B XTPAXENCSEM55RY Manual Motor Protectors, Rotary, Frame D, Insulated Enclosures * Surface Mounting Manual Motor Protectors Description Degree of Protection For Use With... Eaton list number Enclosure, with black/gray rotary handle Enclosure, with red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 60204 IP65 IP65 D-Frame XTPR Only or with: XTPAXFA..., XTPAXFAEM20, XTPAXSA..., XTPAXSATR..., XTPAXUVR..., XTPAXSR..., XTPAXCL XTPAXENCSD65B XTPAXENCSD65RY PG03407001U - June 2006 Manual Motor Protectors, Rotary, Frame B, Insulated Enclosures * Flush Mounting * Integrated terminal for PE(N) connection. XTPAXENCF4O Description Degree of Protection For Use With... Eaton list number Enclosure, cover with aperture dimensioned to accommodate front of MMP. Enclosure, with black/gray rotary handle Enclosure, with red/yellow rotary handle for use as Emergency-Stop switches to IEC/EN 60204 Front IP40 B-Frame XTPR Only or with: XTPAXSA..., XTPAXUVR..., XTPAXSR..., XTPAXCL B-Frame XTPR Only or with: XTPAXSA..., XTPAXUVR..., XTPAXSR..., XTPAXFA..., XTPAXCL XTPAXENCF40 Front IP55 Front IP55 XTPAXENCF55B XTPAXENCF55RY Manual Motor Protector, Rotary, Enclosure Padlock Attachment * For use as main switch to IEC/EN60204 Description For Use With... QPC Eaton list number Padlocking feature. Up to 3 padlocks with 3 - 6 mm hasp thickness. XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY, XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY XTPAXENCSD65B, XTPAXENCSD65RY XTPAXENCF55B, XTPAXENCF55RY 3 XTPAXPL1 1) 1 XTPAXPL2 1) 3 XTPAXPL3 2) XTPAXPL1 Padlocking feature. Up to 3 padlocks with 3 - 6 mm hasp thickness. Padlocking feature. Up to 3 padlocks with 3 - 6 mm hasp thickness. 1) Lockable in the 0-position of the XTPR manual motor protector. 2) Lockable in the OFF position of the B-Frame XTPR manual motor protector. Manual Motor Protector, Pushbutton and Rotary, Frame B, Neutral Terminal * Flush Mounting Enclosures only For Use With... QPC Neutral Terminal for connection of a fifth conductor XTPBXENCF40, XTPBXENCF55, 20 XTPAXENCF40, XTPAXENCF55B, XTPAXENCF55RY Eaton list number XTPAXNT XTPAXNT PG03407001U - June 2006 Manual Motor Protectors Manu al Mo to r Pr otector s Description 63 7 Manual Motor Controllers This chapter provides product selection guidance for Eaton's XT range of Manual Motor Controllers which combine a Manual Motor Protector (MMP's) with an XT contactor(s) to provide a complete motor protection solution by combining motor disconnect function, thermal overload protection, magnetic short circuit protection and remote control operation in one compact assembled unit. Standards * IEC EN 60947-4-1 * CE Marked See page 66 for accessories See page 68 for coil suffix See page 158 for dimensional drawings See page 158 for technical Details Manual Motor Controllers, DOL, Frame B MMP + Frame B Contactor FLA Adjustment Range / Overload Release -- Ir (Amps) Maximum Motor Component Combinations Assembled Controller 1) Ratings Motor kW Rating AC-3 -- P (kW) 3-Phase 380 - 415V Manual Motor Protector Connection Kit Contactor 1) Eaton list number XTPRP25BC1 XTPRP40BC1 XTPRP63BC1 XTPR001BC1 XTPR1P6BC1 XTPR2P5BC1 XTPR004BC1 XTPR6P3BC1 XTPR010BC1 XTPR012BC1 XTPAXTPCB XTPAXTPCB XTPAXTPCB XTPAXTPCB XTPAXTPCB XTPAXTPCB XTPAXTPCB XTPAXTPCB XTPAXTPCB XTPAXTPCB XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE009B10_ XTCE012B10_ XTSCP25BB_ XTSCP40BB_ XTSCP63BB_ XTSC001BB_ XTSC1P6BB_ XTSC2P5BB_ XTSC004BB_ XTSC6P3BB_ XTSC010BB_ XTSC012BB_ XTSCP25BB 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 8 - 12 Underscore (_) indicates Coil Suffix required. See Table Page 68 Manual Motor Co ntro ller s 1) 0.06 0.09 0.18 0.25 0.55 0.75 1.5 2.2 4 5.5 64 Manual Motor Controllers PG03407001U - June 2006 Manual Motor Controllers, DOL, Frame B MMP + Frame C Contactor FLA Adjustment Range / Overload Release -- Ir (Amps) XTSC016BC 10 - 16 16 - 20 20 - 25 25 - 32 Maximum Motor Component Combinations Assembled Controller 1) Ratings Motor kW Rating AC-3 -- P (kW) 3-Phase 380 - 415V Manual Motor Protector Connection Kit Contactor 1) Eaton list number 7.5 9 11 15 XTPR016BC1 XTPR020BC1 XTPR025BC1 XTPR032BC1 XTPAXTPCC XTPAXTPCC XTPAXTPCC XTPAXTPCC XTCE018C10_ XTCE025C10_ XTCE025C10_ XTCE032C10_ XTSC016BC_ XTSC020BC_ XTSC025BC_ XTSC032BC_ 1) Underscore (_) indicates Coil Suffix required. See Table Page 68 Manual Motor Controllers, DOL, Frame D MMP + Frame C Contactor * The connection between the XTPR...DC1 and the XTCE...C... contactor will be made with flexible wire and mounted to the DIN Rail Adapter Plate (XTPAXTPCDP). FLA Adjustment Range / Overload Release -- Ir (Amps) XTSC016DC 10 - 16 16 - 25 25 - 32 Maximum Motor Component Combinations Assembled Controller 1) Ratings Motor kW Rating AC-3 -- P (kW) 3-Phase 380 - 415V Manual Motor Protector 7.5 12.5 15 XTPR016DC1 XTPR025DC1 XTPR032DC1 Connection Kit Contactor 1) Eaton list number XTCE018C10_ XTCE025C10_ XTCE032C10_ XTSC016DC_ XTSC025DC_ XTSC032DC_ 1) Underscore (_) indicates Coil Suffix required. See Table Page 68 Manual Motor Controllers, DOL, Frame D MMP + Frame D Contactor * XTPAXTPCD -- Includes DIN Rail Adapter Plate (XTPAXTPCDP) and electrical contact modules (XTPAXECMD). Prior to release of XTPAXTPCD, the connection between the XTPR...DC1 and the XTCE...D... contactor will be made with flexible wire and mounted to the DIN Rail Adapter Plate (XTPAXTPCDP). Maximum Motor Component Combinations Ratings Motor kW Rating AC-3 -- P (kW) 3-Phase 380 - 415V Manual Motor Protector Connection Kit Contactor 1) Eaton list number 32 - 40 40 - 50 50 - 58 55 - 63 20 25 30 34 XTPR040DC1 XTPR050DC1 XTPR058DC1 XTPR063DC1 XTPAXTPCD XTPAXTPCD XTPAXTPCD XTPAXTPCD XTCE040D10_ XTCE050D10_ XTCE065D10_ XTCE065D10_ XTSC040DD_ XTSC050DD_ XTSC058DD_ XTSC063DD_ Assembled Controller 1) 1) Underscore (_) indicates Coil Suffix required. See Table Page 68 PG03407001U - June 2006 Manual Motor Controllers Manual Motor Co ntro ller s XTSC040DD FLA Adjustment Range / Overload Release -- Ir (Amps) 65 Combination Controller, DOL, Connection Kits XTPAXTPCB Description Eaton list number Includes: Mechanical & Electrical Connection Element for XTPR...B... (MMP) and XTCE...B... (Contactor). Includes: Mechanical & Electrical Connection Element for XTPR...B... (MMP) and XTCE...C... (Contactor) and DIN Rail Adapter Plate. Includes: Mechanical & Electrical Connection Element for XTPR...D... (MMP) and XTCE...D... (Contactor) and DIN Rail Adapter Plate. XTPAXTPCB 1) 1) 2) XTPAXTPCC 2) XTPAXTPCD Comprised of mechanical connection element for MMP and contactor with main current wiring between MMP and contactor in the tool-less plug connection. Comprised of a top-hat rail adapter plate and main current wiring between MMP and contactor. Combination Controller, DOL Reversing, Connection Kits XTPAXTPCRB Description Eaton list number Includes: Mechanical & Electrical Connection Element for XTPR...B... (MMP) and (2) XTCR...B... (Contactors) Includes: Mechanical & Electrical Connection Element for XTPR...B... (MMP) and (2) XTCR...C... (Contactors) and DIN Rail Adapter Plate. Includes: Mechanical & Electrical Connection Element for XTPR...D... (MMP) and (2) XTCR...D... (Contactors) and DIN Rail Adapter Plate. XTPAXTPCRB 1) XTPAXTPCRC 2) XTPAXTPCRD 1) Comprised of mechanical connection element for MMP and contactor with reversing combination main current wiring in the tool-less plug con2) nection. Control cables for electrical interlocking in toolless plug connection: K1M:A1 - K2M:21, K1M:21 - K2M:A1, K1M:A2 - K2M:A2. Comprised of a top-hat rail adapter plate and reversing combination main current wiring. Combination Controller Connection Kits Mounting Plate For Use with ... Description XTPAXTPCB For mounting of a B-Frame Non-reversing Manual or Manual 4 Motor Controller For mounting of a B-Frame Reversing Manual or Combination 4 Motor Controller XTPAXTPCRB XTPAXTPCPB Pkg. Qty. Eaton list number 1) XTPAXTPCPB XTPAXTPCRPB Manual Motor Co ntro ller s 1) Comprised of 45 mm wide adapter plate and connection elements for side-by-side positioning of more plates. 66 Manual Motor Controllers PG03407001U - June 2006 Manual Motor Controller, DOL Reversing, Frame B MMP + (2) Frame B Contactors FLA Adjustment Range / Overload Release -- Ir (Amps) XTSRP25BB 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.3 6.3 - 10 8 - 12 Maximum Motor Component Combinations Ratings kW Manual Motor Connection Kit Protector Assembled Controller 1) Contactor 1) Eaton list number 3-Phase 380 - 415V 0.06 0.09 0.18 0.25 0.55 0.75 1.5 2.2 4 5.5 XTPRP25BC1 XTPRP40BC1 XTPRP63BC1 XTPR001BC1 XTPR1P6BC1 XTPR2P5BC1 XTPR004BC1 XTPR6P3BC1 XTPR010BC1 XTPR012BC1 XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTPAXTPCRB XTCE007B01_ XTCE007B01_ XTCE007B01_ XTCE007B01_ XTCE007B01_ XTCE007B01_ XTCE007B01_ XTCE007B01_ XTCE009B01_ XTCE012B01_ XTSRP25BB_ XTSRP40BB_ XTSRP63BB_ XTSR001BB_ XTSR1P6BB_ XTSR2P5BB_ XTSR004BB_ XTSR6P3BB_ XTSR010BB_ XTSR012BB_ 1) Underscore (_) indicates Coil Suffix required. See page 68. Manual Motor Controller, DOL Reversing, Frame B MMP + (2) Frame C Contactors XTSR016BC FLA Adjustment Range / Overload Release -- Ir (Amps) Maximum Motor Component Combinations Ratings kW Manual Motor Connection Kit Protector 10 - 16 16 - 20 20 - 25 25 - 32 7.5 9 11 15 Assembled Controller 1) Contactor 1) Eaton list number 3-Phase 380 - 415V XTPR016BC1 XTPR020BC1 XTPR025BC1 XTPR032BC1 XTPAXTPCRC XTPAXTPCRC XTPAXTPCRC XTPAXTPCRC XTCE018C01_ XTCE025C01_ XTCE025C01_ XTCE032C01_ XTSR016BC_ XTSR020BC_ XTSR025BC_ XTSR032BC_ 1) Underscore (_) indicates Coil Suffix required. See page 68. Manual Motor Controller, DOL Reversing, Frame D MMP + (2) Frame C Contactors * The connection between the XTPR...DC1 and the XTCE...C... contactor will be made with flexible wire and mounted to the DIN Rail Adapter Plate (XTPAXTPCDP). Maximum Motor Component Combinations Ratings kW Manual Motor Connection Kit Protector 10 - 16 16 - 25 25 - 32 7.5 12.5 15 Assembled Controller 1) Contactor 1) Eaton list number 3-Phase 380 - 415V XTPR016DC1 XTPR025DC1 XTPR032DC1 XTCE018C01_ XTCE025C01_ XTCE032C01_ XTSR016DC_ XTSR025DC_ XTSR032DC_ 1) Underscore (_) indicates Coil Suffix required. See page 68. Manual Motor Controller, DOL Reversing, Frame D MMP + (2) Frame D Contactors * XTPAXTPCRD -- Available June 2006 and will include two DIN Rail Adapter Plates (XTPAXTPCDP) and electrical contact module (XTPAXECMRD). Prior to release of XTPAXTPCD, the connection between the XTPR...DC1 and the two XTCE...D... contactors will be made with flexible wire and mounted to the DIN Rail Adapter Plates (XTPAXTPCDP). FLA Adjustment Range / Overload Release -- Ir (Amps) Maximum Motor Component Combinations Ratings kW Manual Motor Connection Kit Protector 32 - 40 40 - 50 50 - 58 55 - 63 20 25 30 34 XTSR04DD Assembled Controller 1) Contactor 1) Eaton list number 3-Phase 380 - 415V XTPR040DC1 XTPR050DC1 XTPR058DC1 XTPR063DC1 XTPAXTPCRD 2) XTPAXTPCRD 2) XTPAXTPCRD 2) XTPAXTPCRD 2) XTCE040D01_ XTCE050D01_ XTCE065D01_ XTCE065D01_ XTSR040DD_ XTSR050DD_ XTSR058DD_ XTSR063DD_ Manual Motor Co ntro ller s XTSR016DC FLA Adjustment Range / Overload Release -- Ir (Amps) 1) Underscore (_) indicates Suffix required. See page 68. PG03407001U - June 2006 Manual Motor Controllers 67 AC and DC Coil Suffixes Coil Voltage 50Hz Frame B Contactors 110V 220V , 230V 24V 415V 550V 190V 240V 380V 400V 12V 24V 42V 48V Frame C and D Contactors 110V 220V 230V 24V 415V 550V 190V 240V 380V 400V Manual Motor Co ntro ller s 12V 24V 42V 48V 68 1) 2) Manual Motor Controllers Suffix Code1) 60Hz DC 120V 240V 120V 220V 12V 24V 48V A B F T C D E G H L N P R U W Y AD 2) BD 2) RD 2) TD WD 2) 110-130V 200-240V 12-14V 24-27V 48-60V A B F T C D E G H L N P R U W Y AD 2) BD 2) RD 2) TD WD 2 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V 120V 240V 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V Add suffix in place of underscore (_) to Eaton list number With DC Operation: Integrated diode-resistor combination, coil rating 2.6W. PG03407001U - June 2006 8 Technical details INDEX Approvals for World Markets IEC Utilisation categories used in technical data and formula Examples of Utilisation Categories for Low Voltage Switchgear and Controlgear On-line Instructional leaflets 71 75 76 77 Relays and Timers Miniature Relays and auxiliary contacts, dimensional drawings Standard Relats and auxiliary contacts, dimensional drawings Control Relays, Eaton Numbering System Electronic Timing Relays, Eaton Numbering System Miniature and Standard Relays, Technical Data and Specifications Electronic Timing Relays, Technical Data and Standards 78 78 79 80 80 81 83 Miniature Controls Miniature Contactors, Accessories and Overload Relays, dimensional drawings Miniature Contactors, Wiring Diagrams Miniature Contactors, Eaton Numbering System Miniature Overload Relays, Eaton Numbering System Miniature Contactors, Technical Data and Standards, General Specifications Miniature Contactors, Tecnhical Data and Standards, Magnet System Miniature Contactors, Data and Standards, Utilisation ratings Miniature Contactors, Technical Data and Standards, Auxiliary Contacts Miniature Overload Relays, Settings Miniature Overload Relays, Tripping Characteristic Chart 84 84 85 86 86 87 88 89 90 91 91 PG03407001U - June 2006 92 92 92 92 93 93 94 94 95 95 96 96 97 97 98 98 99 99 99 100 100 101 102 103 103 103 104 104 105 106 107 109 111 113 115 116 120 120 T echn ic al de ta ils Standard Contactors, Overload Relays and Starters Standard, 3P Contractors, Frame B, Screw Terminals, dimensional drawing Standard, 3P Contractors, Frame B, Cage Terminals, dimensional drawing Standard, 3P Contractors, Frame C, dimensional drawing Standard, 3P Contractors, Frame D, dimensional drawing Standard, 3P Contractors, Frame F - G, dimensional drawing Standard, 3P Contractors, Frame L - M, dimensional drawing Standard, 3P Contractors, Frame N, dimensional drawing Standard, 3P Contractors, Frame P, dimensional drawing Standard, 3P Contactors, Frame R, dimensional drawing Standard, 3P Contactors, Frames B - G, DOL Reversing, dimensional drawings Standard, 3P Contactors, Frames L - M, Mechanical Interlock, dimensional drawings Standard, 3P Contactors, Frames L - N, with Terminal Shrouds Standard, 3P Contactors, Frames L - M, Cable Terminal Block, dimensional drawings Standard, 3P Contactors, Frames M - N, Flat Strip Conductor Terminals Standard, Contactors, Frames B - F, Suppressor, dimensional drawings Standard, Overload Relays, Frames B - C, dimensional drawings Standard, Overload Relays, Frame D, dimensional drawings Standard, Overload Relays, Frames B - C & D, DIN Rail or Panel Mount Adapter, dimensional drawings Standard, Overload Relay, Frames F - G, dimensional drawings Standard, Overload Relay, Frame L, dimensional drawings Standard, Overload Relay, Current Transformer Operated, dimensional drawings Standard, Overload Relays, Frames B - F, Fitting Overviews Standard Starters, DOL, Frame B, dimensional drawings Standard Starters, DOL, Frame C, dimensional drawings Standard Starters, DOL, Frame D, dimensional drawings Standard Starters, DOL, Frames F - G, dimensional drawings Standard Starters, DOL, Frame L, dimensional drawings Standard Contactors and Starters, Eaton Numbering System Standard Contactors, Frame B, Technical Data and Standards Standard Contactors, Frames C - D, Technical Data and Standards Standard Contactors, Frames F - G, Technical Data and Standards Standard Contactors, Frames L - M, Technical Data and Standards Standard Contactors, Frames N - R, Technical Data and Standards Standard Contactors, Frames L - N, Utilisation Categories, Maximum Operating Frequency Standard Contactors, Frames B - R, AC1, 3, 4, 6A and 6B Electrical Indurance Ratings Standard Contactors, Frames B - R, DC-1, Electrical Indurance Ratings Standard Contactors, Frames B - R, DC-3, Electrical Indurance Ratings Technical details 69 T echn ic al de ta ils 70 Standard Contactors, Frames B - R, DC-5, Electrical Indurance Ratings Standard, 3P Contactors, Frames B - R, Current Heat Loss, watts Standard, Contactors, Frames B - N, Mechanical Life Curves Standard, Contactors, Frames B - D, Coil Data Standard, Contactors, Frames F - G, Coil Data Standard, Contactors, Frames L - R, Coil Data Standard, Contactors, Frames B - N, Auxiliary Contacts, Technical Data and Specifications Auxiliray Contacts Possible Combinations Auxiliray Contacts Combinations Standard, 3P Contactors, Frames B - R, Contact Sequence (Circuit Symbols) Standard Contactors, Wiring Diagrams Standard, Overload Relays, Settings and Tripping Characteristics Standard, Overload Relays, Technical Data and Standards Standard Overload Relays, Type 2 Co-ordination with XT Contactors and BS88 Fuses 121 121 122 124 125 126 128 129 130 131 131 132 133 135 Manual Motor Protectors Manual Motor Protectors, Frame B, Pushbutton, dimensional drawing Manual Motor Protectors and Manual Transformer Protectors, Frame B, Rotary, dimensional drawings Manual Motor Protectors, Frame B, Rotary with Current Limiter, dimensional drawing Manual Motor Protectors, Frame B, Rotary with Early-Make Auxiliary Contacts, dimensional drawing Manual Motor Protectors, Frame D, Rotary, dimensional drawing Manual Motor Protectors, Frames B and D, Standard Auxiliary Contact, dimensional drawing Manual Motor Protectors, Frames B and D, Trip Indicating Auxiliary Contact, dimensional drawing Manual Motor Protectors, Frames B and D, Undervoltage / Shunt Release, dimensional drawing Manual Motor Protectors, Frames B and D, 3P Commoning Links, dimensional drawing Manual Motor Protectors, Frames B and D, Incoming Terminal, Line Side Adapter, dimensional drawings Manual Motor Protectors, Insulated Enclosures, Surface mount, dimensional drawings Manual Motor Protectors, Insulated Enclosures, Flush mount, dimensional drawings Manual Motor Protectors, Insulated Enclosures, Drilling and Cutout, dimensional drawings Manual Motor Protectors, Eaton numbering System Manual Motor Protectors, Frames B and D, Technical Data and Standards Manual Motor Protectors, Auxiliary Contacts, Technical data and Standards Manual Motor Protectors, Under Voltage Release, Technical data and Standards Manual Motor Protectors, Current Limiter, Technical data and Standards Manual Motor Protectors, Shunt Release, Technical data and Standards Manual Motor Protectors, Frames B and D, Time Current Curve Characteristics Manual Motor Protectors, Frames B and D, Short Circuit Ratings Manual Motor Protectors, Frames B and D, Ratings for Group Motor Applications, UL 508/CSA C22.2 No.14 Manual Motor Protectors MMC and Manual Motor Controllers MMC, Frames B and D, Ratings Manual Motor Protectors,Frames B and D, Wiring diagrams Manual Motor Protectors, Protection of PVC insulated cables against thermal overload at Short Circuit Manual Motor Protectors, Fuseless installation with XTPR, Back-up protection diagrams 136 136 137 137 137 138 138 138 138 139 140 141 144 147 147 148 149 147 150 150 151 153 154 155 156 157 157 Manual Motor Controllers Manual Motor Controllers Frames B and D, Dimensional drawings Manual Motor Controllers Frames B and D, Technical data and Specifications Manual Motor Controllers, Eaton Numbering System 158 158 158 159 User's Guide to IEC Type 1 and Type 2 Coordination Defining Pass/Fail Criteria: UL 508/CSA C22.2 No. 14 and IEC 60947-4-1 400/415V Type 2 Coordination, MMC 400/415V Contactor and Overload Relay (Motor Starter) with Fused Disconnect 500V Type 2 Coordination, Contactor and Overload Relay (Motor Starter) with Fused Disconnect 690V Type 2 Coordination, Contactor and Overload Relay (Motor Starter) with Fused Disconnect 400/415V Contactor and Overload Relay (Motor Starter) with Circuit Breaker 160 161 162 163 163 164 165 Master Coil Suffix Table 166 Technical details PG03407001U - June 2006 Approvals for World Markets Europe Conformite Europeen (CE) This mark denotes that the device carrying it conforms to all relevant requirements and specifications. The mandatory application of this mark therefore enables the unrestricted use of marked devices within the European economic area. Since January 1996, all devices sold within the European union must comply with the Electromagnetic Compatibility (EMC) Directive. XT has passed the required tests to these Directives, and the devices carry the CE mark, demonstrating compliance with the EMC Directive. Because devices bearing the CE mark comply with the harmonized standards, approval and the associated marking is no longer required in the following countries: Belgium Comite Electrotechnique Belge Belgisch Elektrotechnisch Comite (CEBEC) Netherlands Naamloze Vennootschap tot Keuring van Electrotechnische Materialien (KEMA) Denmark Danmarks Elektriske Materielkontrol (DEMKO) Norway Norges Elektriske Materiellkontrol (NEMKO) Finland (FIMKO) Sweden Svenska Elektriska MaterielKontrollanstalten (SEMKO) France Union Technique de l'Electricite (UTE) Switzerland Schweizerischer Elektrotechischer Verein (SEV) Devices the USA and Canada have UL and CSA approval. USA Underwriters Laboratories (UL) Listing T echn ic al de ta ils Recognition Canada Canadian Standards Association (CSA) Recently introduced is the mandatory approval of electrical products for: * Slovakia * Poland * South Africa * China * Russia * Turkey * Argentina PG03407001U - June 2006 Technical details 71 Marking is partly mandatory for these countries. The IEC rating data is accepted as in other European countries. Approval is not mandatory in the Czech Republic and Hungary. The manufacturer's declaration of conformity is sufficient here. Romania requires that components that are to be used in public buildings must be approved by the Romanian test authority ICECON. Russia Devices for Russia must bear the appropriate marking. Russia Goststandart (GOST-R) South Africa ZA SABS Argentina Selection of Devices "Selection appropriate for export" does not mean merely meeting the requisite approvals and conformity to relevant specifications. The meaning of the term goes a great deal further by even including that equipment and installations must be designed to a concept with export in mind. The following are important criteria for selecting switchgear suitable for export: * For motor-protective circuit-breakers Use inherently short-circuit proof switches capable of controlling the highest prospective fault levels at the point of installation without the need for back-up protection. - Advantage: - No restrictions whatsoever for installation - Complete independence from the on-site protective system - No problems getting spare parts * For circuit-breakers Use types with visible contacts, quick-make and quick-break operation as standard. Use current-limiting circuit-breakers for high short-circuit levels. Selective switches are recommended for the selective graduation of networks. T echn ic al de ta ils - Advantage: - Independence from local accident prevention regulations requiring visible contacts, and safety faults caused by inexperienced operating personnel. - The effects of short-circuits are kept to a minimum. - Fuseless installations offer greater safety and reliability in plant operation. In the event of a fault, only the faulty section of the system is isolated. * For contactors Use contactors whose entire range provides consistently reliable operation in the event of voltage drops (consistently down to 80% Un should be aimed for) and whose contact system will not assume an indeterminate position either on closing or on opening in such conditions. 72 - Advantage: - During the electrification work in areas such as Africa and the Middle East, an insufficient voltage stability is -- at least for a certain time -- likely in many applications (for example due to long spur lines or small local generators). The use of devices that fulfill the above requirements will eliminate one of the main failure causes related to contactors. * For enclosures Use insulated enclosures with transparent covers (i.e. "totally insulated" enclosures). - Advantage: - Total insulation is the best possible protective measure from the user's point of view, avoiding reliance on the possibly doubtful skills of unknown installation personnel. Furthermore, protective measures based on earthing are often extremely difficult, if not impossible (in the Middle East, for example, due to the dryness of the ground). - Insulated enclosures completely eliminate the need for any additional protection against corrosion. The transparent covers contribute significantly to the correct operation of a system, because switchgear operation can be monitored even with the doors or covers closed, thus virtually eliminating the possibility of these being left open through carelessness. The transparent cover is an important contribution to safety, especially where exports to areas of uncertain skills are concerned. Technical details PG03407001U - June 2006 * For overcurrent protective devices Always use circuit-breakers and motor-protective circuit-breakers. Avoid fuses as far as possible. - Advantage: - The operational reliability of a system is especially important for export contracts. Circuit-breakers and motor-protective circuit-breakers provide this reliability in full measure since they can be immediately reclosed once a fault has been cleared, they disconnect all poles, they have ideal protection through high tripping accuracy and they can be used for selective operation. Because they have no fuses or other consumables, they also greatly reduce the problem of obtaining replacement parts. The advantages of fuseless design for export are especially evident in this case. No complicated investigation is needed to find out which fusing system is used in the respective location and which specifications have to be followed to select the correct fuses. Often several different fuse systems with widely varying characteristics are used side-by-side in the same country. For the uninitiated, it may be almost impossible to find the right fuse in these circumstances. These problems do not arise where a circuit-breaker is used. * For main switches and safety switches Use devices with positive contact separation and clear switch position indication. - Advantage: - The mechanical coupling of the actuating element with the contacts ensues that the OFF position is indicated only when all main contacts are separated by the prescribed distance, and only in this position can the switch be padlocked. This ensures safety when carrying out maintenance and repair work on the installation or machinery. Test Authorities USA USA UL Canada CDN CSA Romania RO ICECON Russia RUS GOST-R South Africa ZA SABS Slovakia SK SKTC Poland PL BBJ-SEP Turkey TR TSE T echn ic al de ta ils China PRC CCC Ukraine UA Ukrain-GOST Shipping Classifications Germany Germanischer Lloyd (GL) Great Britain Lloyd`s Register of Shipping (LR) PG03407001U - June 2006 Technical details 73 France Bureau Veritas (BV) Russia Russian Maritime Register of Shipping (RS) Italy Registro Italiano Navale (RINA) Norway Det Norske Veritas (DNV) Poland Polski Rejestr Statkow (PRS) Approvals for North America Type of Approval Approval Mark The device is UL- and CSA-approved as discrete device. The device is CSA-approved as discrete device. The device is UL-approved as discrete device. T echn ic al de ta ils The device contains UL-approved components; its approval conditions must be maintained in use (UL Recognized). The device is CSA-approved as discrete device. 74 Technical details PG03407001U - June 2006 IEC Utilisation Categories used in Technical Data and Formulas (See also IEC/EN 60947-1; 2.1.18/IEV 441-17-19) A combination of specified requirements relating to the condition in which the switching device or fuse fulfills its purpose and selected to represent a characteristic group of real-life applications. The specified requirements may, for example, relate to the values of making and breaking capacity and other characteristic values, data concerning associated circuits and the applicable conditions of use and operational behaviour. Descriptions Code Descriptions DF Duty factory Irmv Response value of short-time delayed short-circuit release In Response value of earth-fault release Isd Response value of short-time delayed short-circuit release Icm Rated short-circuit making capacity IT Response value of earth-fault release Icn Rated short-circuit breaking capacity Ig Response value of earth-fault release Ics Rated service short-circuit breaking capacity Ith Conventional free air thermal current Icu Rated ultimate short-circuit breaking capacity Ithe Conventional thermal current of enclosed devices Icw Rated short-time withstand current Iu Rated uninterrupted current Ie Rated operational current SNT Transformer rating Ik Transformer initial short-circuit AC current tr Time delay of overload release response IL Load monitoring response value tT Time delay of earth-fault release response In Rated current tg Time delay of earth-fault release response INT Transformer rated current tv Time delay of short-circuit release response IPK Rated peak withstand current Uc Rated actuating voltage Iq Rated conditional short-circuit current Ue Rated operational voltage Ir Overcurrent release set value Ui Rated insulation voltage Irm Response value of non-delayed short-circuit release Uimp Rated impulse withstand voltage Ii Response value of non-delayed short-circuit release Uk Transformer short-circuit voltage Irmf Response value of fixed, non-delayed short-circuit release Us Rated control voltage T echn ic al de ta ils Code PG03407001U - June 2006 Technical details 75 Examples of Utilization Categories for Low Voltage Switchgear and Controlgear Category 60947-4-1 60947-4-1 60947-4-1 60947-4-1 AC-5a AC-5b AC-6a AC-6b AC-7a AC-7b AC-8a AC-8b AC-12 AC-12 AC-13 AC-14 AC-15 AC-20 AC-21 AC-22 AC-23 AC-31 AC-33 60947-4-1 60947-4-1 60947-4-1 60947-4-1 61095 61095 60947-4-1 60947-4-1 60947-5-1 60947-5-2 60947-5-1 60947-5-1 60947-5-1 60947-3 60947-3 60947-3 60947-3 60947-6-1 60947-6-1 T echn ic al de ta ils AC-41 AC-42 AC-43 AC-44 76 AC-45a AC-45b AC-51 AC-52a AC-52b AC-53a AC-53b AC-55a AC-55b AC-56a AC-56b AC-58a AC-58b AC-140 2) 3) Relevant IEC Product Standard Nature of Current -- AC AC-1 Non-inductive or slightly inductive loads, resistance furnaces AC-2 Slip-ring motors: starting, switching off AC-3 Squirrel-cage motors: starting, switching off motors during running AC-4 Squirrel-cage motors: starting, plugging 2), inching 3) AC-35 AC-36 AC-40 1) Typical Applications Switching of electric discharge lamp controls Switching of incandescent lamps Switching of transformers Switching of capacitor banks Slightly inductive loads for household appliances and similar applications Motor-loads for household applications Hermetic refrigerant compressor motor control with manual resetting of overload releases Hermetic refrigerant compressor motor control with automatic resetting of overload releases Control of resistive loads and solid-state loads with isolation by optocouplers Control of resistive loads and solid-state loads with optical isolation Control of solid-state loads with transformer isolation Control of small electromagnetic loads Control of AC electromagnetic loads Connecting and disconnecting under no-load conditions Switching of resistive loads, including moderate overloads Switching of mixed resistive and inductive loads, including moderate overloads Switching of motor loads or other highly inductive loads Non inductive or slightly inductive loads Motor loads or mixed loads including motors, resistive loads and up to 30% incandescent lamp loads Electric discharge lamp loads Incandescent lamp loads Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive reactance Non-inductive or slightly inductive loads, resistance furnaces Slip-ring motors: starting, switching off Squirrel-cage motors: starting, switching off motors during running Squirrel-cage motors: starting, plugging 2), inching 3) Switching of electric discharge lamp controls Switching of incandescent lamps Non-inductive or slightly inductive loads, resistance furnaces Control of slip ring motor stators: 8 h duty with on-load currents for start, acceleration, run Control of slip ring motor stators: intermittent duty Control of squirrel-cage motors: 8 h duty with on-load currents for start, acceleration, run Control of squirrel-cage motors: intermittent duty Switching of electric discharge lamp controls Switching of incandescent lamps Switching of transformers Switching of capacitor banks Control of hermetic refrigerant compressor motors with automatic resetting of overload releases: 8 h duty with on-load currents for start, acceleration, run Control of hermetic refrigerant compressor motors with automatic resetting of overload releases: intermittent duty Control of small electromagnetic loads with holding (closed) current 0,2 A, e.g. contactor relays 60947-6-1 60947-6-1 60947-6-2 60947-6-2 60947-6-2 60947-6-2 60947-6-2 60947-6-2 60947-6-2 60947-4-3 60947-4-2 60947-4-2 60947-4-2 60947-4-2 60947-4-3 60947-4-3 60947-4-3 60947-4-3 60947-4-2 60947-4-2 60947-5-2 60947-1 (c) IEC: 2004. By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. Technical details PG03407001U - June 2006 Examples of Utilization Categories for Low Voltage Switchgear and Controlgear 1) (Continued) Category 60947-4-1 60947-4-1 DC-5 60947-4-1 DC-23 DC-31 DC-33 DC-36 DC-40 DC-41 DC-43 DC-45 DC-46 2) 3) Relevant IEC Product Standard Nature of Current -- AC - DC A Protection of circuits, with no rated short-time withstand current B Protection of circuits, with a rated short-time withstand current Nature of Current -- DC DC-1 Non-inductive or slightly inductive loads, resistance furnaces DC-3 Shunt-motors: starting, plugging 2), inching 3), Dynamic breaking of motors DC-6 DC-12 DC-12 DC-13 DC-13 DC-14 DC-20 DC-21 DC-22 1) Typical Applications Series-motors: starting, plugging 2), inching 3), Dynamic breaking of motors Switching of incandescent lamps Control of resistive loads and solid-state loads with isolation by optocouplers Control of resistive loads and solid-state loads with optical isolation Control of electromagnets Control of electromagnets Control of electromagnetic loads having economy resistors in circuit Connecting and disconnecting under no-load conditions Switching of resistive loads, including moderate overloads Switching of mixed resistive and inductive loads, including moderate overloads (e.g. shunt motors) Switching of motor loads or other highly inductive loads (e.g. series motors) Resistive loads Motor loads or mixed loads including motors Incandescent lamp loads Distribution circuits comprising mixed resistive and reactive loads having a resultant inductive reactance Non-inductive or slightly inductive loads, resistance furnaces 60947-2 60947-2 60947-4-1 60947-5-1 60947-5-2 60947-5-1 60947-5-2 60947-5-1 60947-3 60947-3 60947-3 60947-3 60947-6-1 60947-6-1 60947-6-1 60947-6-2 Dynamic breaking of DC 60947-6-2 60947-6-2 Series-motors: starting, plugging 2), inching 3), Dynamic breaking of DC Switching of incandescent lamps 60947-6-2 Shunt-motors: starting, plugging 2), inching 3), 60947-6-2 60947-1 (c) IEC: 2004. By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. On-line Instructional leaflets Inside of Packaging XTMC, XTMF Miniature Contactors, XTRM Miniature Control Relay and Accessories Pub51243 Inside of Packaging XTOM Miniature Overload Relays Pub51206 Miniature Reversing Link Kits MN03402002EXTOM Miniature Overload Relays Installation and User Manual Pub51219 Inside of Packaging XTRM Miniature Control Relays Pub51210 Inside of Packaging 7-15A XTCE Contactors and XTRE Control Relays Pub51244 XTTR Electronic Star-Delta Timer Pub51245 XTMT Miniature Electronic On-Delay and Multi-Function Timers T echn ic al de ta ils Pub51219 PG03407001U - June 2006 Technical details 77 8 Technical details Relays and Timers Miniature Relays and auxiliary contacts, dimensional drawings M4 5.5 58 50 45 35 52 - 54 Miniature Control Relay 43 M4 58 45 50 35 65.3 45 Miniature Control Relay with XTMCX IP40 Shroud M4 62.5 50 T echn ic al de ta ils 45 35 52 - 54 Miniature Control Relay with RC or Varistor Suppressor M4 58 50 45 83 - 86 35 Miniature Control Relay with XTMCXPA Auxiliary Contact 78 Technical details PG03407001U - June 2006 Standard Relays and auxiliary contacts, dimensional drawings 36 4 x M4 Dia. 18 45 68 60 3.2 8.7 Typ. 5.1 45 35 6.5 75 T echn ic al de ta ils 116.3 PG03407001U - June 2006 Technical details 79 Control Relays, Eaton Numbering System XT RE C 10 B 22 AD Coil Code Product Line Prefix See Table 4 on Page 3. XT = XT IEC Power Control Contact Configuration Product Family Code RM = Mini IEC Control Relay RE = IEC Control Relay 40 = 4NO 31 = 3NO-1NC 22 = 2NO-2NC Terminations Frame Blank = Screw Terminals C= Spring Cage Terminals For XTRM A = 45 mm -- Mini Conventional Thermal Current Rating For XTRE B = 45 mm -- Standard 10 = 10A Electronic Timing Relays, Eaton Numbering System XT MT 6 B 30S 11 B Coil Code Product Line Prefix B = 24 - 240V AC/DC XT = XT IEC Power Control Product Family Code Function MT = Mini IEC Timing Relay TR = Star-Delta (Wye-Delta) Electronic Timing Relay For XTMT Time Range Max. For XTMT Conventional Thermal Current Rating 6 = 6A Frame A = 45 mm 30S = 1.5 - 30 s 60H = 0.05 - 1 s 0.15 - 3 s 0.5 - 10 s 3 - 60 s 0.15 - 3 min 0.5 - 3 min 3 - 60 min 0.15 - 3 h 0.5 - 3 h 3 - 60 h 11 = On-Delay 70 = Adjustable For XTTR 51 = Star-Delta For XTTR T echn ic al de ta ils 60S = 3 - 60 s 80 Technical details PG03407001U - June 2006 Miniature and Standard Relays, Technical Data and Specifications Description Standards General Lifespan, Mechanical AC Operated DC Operated Maximum operating frequency (ops/hr) Climatic Proofing Ambient Temperature Open (C) Enclosed (C) Ambient Temperature for Storage (C) Mounting Position XTRE XTCEXFAC_ IEC/EN 60947, VDE 0660, UL, CSA XTRM XTMCXFA_ 20,000,000 10,000,000 10,000,000 10,000,000 20,000,000 10,000,000 20,000,000 20,000,000 9000 9000 9000 9000 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-230 -25 -- 60 -25 -- 40 -40 -- 80 -25 -- 60 -25 -- /40 -40 -- 80 30 90 90 90 -25 -- 50 -25 -- 50 -25 -- 40 -25 -- 40 -- -- As required, except vertically A1/A2 at the bottom 180 Solid (mm2) Flexible with ferrule (mm2) Solid or stranded (AWG) Terminal screw Pozidriv screwdriver Standard screwdriver (mm) Max. tightening torque (Nm) Spring cage terminals Solid (mm2) Flexible with or without ferrule DIN 46228 (mm2) Solid or stranded (AWG) Standard screwdriver (mm) PG03407001U - June 2006 7g 7g 5g 5g IP20 IP20 Finger- and back-of-hand proof 10g 8g IP20 10g 8g IP20 0.23 0.28 0.17 0.20 -- -- 0.05 0.05 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M3.5 Size 2 0.8 x 5.5 1x6 1.2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18 - 14 M3.5 Size 2 1.2 M3.5 Size 2 0.8 x 5.5 1x6 1.2 M3.5 Size 2 1.2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 T echn ic al de ta ils Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Base unit with auxiliary contact module Make contact Break contact Half-sinusoidal shock 20 ms Degree of Protection Protection against direct contact from the front when actuated by a perpendicular test finger (IEC 536) Weight AC operated (kg) DC operated (kg) Terminal capacity Screw terminals 0.6 x 3.5 Technical details 81 Miniature and Standard Relays, Technical Data and Specifications (Continued) Description Contacts Interlocked opposing contacts to ZH 1/457, including auxiliary contact module Rated impulse withstand voltage (Uimp) V AC 6000 6000 6000 6000 Overvoltage category/pollution degree Rated insulation voltage (Ui) V AC III/3 690 III/3 690 III/3 690 III/3 690 Rated operational voltage (Ue) V AC 690 500 600 600 400 400 400 400 300 300 300 300 6 4 1.5 6 3 -- 6 3 1.5 4 2 1.5 10 6 10 3 6 1 5 -- -- -- -- -- -- -- 2.5 -- 2.5 -- 1.5 -- 0.5 2.5 -- 2.5 -- 1.5 -- 0.5 -- 4 -- 4 -- 2 -- 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Safe isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and auxiliary contacts (V AC) Between the auxiliary contacts (V AC) Rated operational current AC-15 220/240V Ie 380/415V Ie 500V Ie DC-13 1) DC-13 L/R <15 mS Contacts in series: Contacts in series: 1:24V 1 1:60V 1 2:60V 1 1:110V 1 3:110V 1 1:220V 1 3:220V 1 DC-13 L/R< 50 mS Contacts in series: Contacts in series: 2:24V -- 3:24V 3 2:60V -- 3:60V 3 1:110V -- 3:110V 3 1:220V -- 3:220V 3 Control Circuit Reliability (at Ue = 24V DC, Umin = 17, Imin = 5.4 mA) Voltage 24 -- 60V 24 -- 60V 24 -- 60V 24 -- 60V 24 -- 60V 24 -- 60V 24 -- 60V Voltage -- 24 V -- 60V -- 110V -- 220V XTRM XTMCXFA_ Yes Yes Yes Yes <10-8, < one failure in 100 million operations center 16 16 10 10 Short-circuit rating without welding Maximum overcurrent protective device 220/240V - XTPR Frame B 380/415V - XTPR Frame B 4 4 -- -- 4 4 4 4 10 -- 10 -- 6 10 6 10 0.3 0.3 0.3 0.3 0.2 0.3 0.2 0.3 0.8 - 1.1 0.8 - 1.1 -- -- 0.8 - 1.1 0.85 - 1.1 -- -- 0.8 - 1.1 0.7 - 1.3 -- -- 0.85 - 1.3 0.7 - 1.3 -- -- 24 19 -- -- 25 22 -- -- AC operated (W) DC operated (W) T echn ic al de ta ils XTCEXFAC_ Conventional thermal current (Ith) Short-circuit protection, max. fuse 2) 500V (A gG/gL) 500V (A fast) Current heat losses at load of Ith 82 XTRE Magnet Systems Pick-up and drop-out values AC operated Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz (Pick-up x Uc) Dual-frequency coil 50/60 Hz (Pick-up x Uc) DC operated 3) Pick -up voltage (Pick-up x Uc) At 24V: without auxiliary contact module (40C) (Pick-up x Uc) Power consumption Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Pick-up VA Pick-up W Technical details PG03407001U - June 2006 Miniature and Standard Relays, Technical Data and Specifications (Continued) dimens Description Contacts Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Sealing VA Sealing W Dual-frequency coil 50/60 Hz at 50 Hz Pick-up VA Pick-up W Dual-frequency coil 50/60 Hz at 50 Hz Sealing VA Sealing W Dual-frequency coil 50/60 Hz at 60 Hz Pick-up VA Pick-up W Dual-frequency coil 50/60 Hz at 60 Hz Sealing VA Sealing W DC operated Pull-in = sealing (W) Duty factor --% DF Switching times at 100% Uc (approximate values) AC operated closing delay (mS) AC operated make contact opening delay (mS) AC operated with auxiliary contact module, max. closing delay (mS) DC operated closing delay (mS) DC operated make contact opening delay (mS) DC operated with auxiliary contact module, max. closing delay (mS) 1) 2) 3) XTRE XTCEXFAC_ XTRM XTMCXFA_ 3.4 1.2 -- -- 4.6 1.3 -- -- 27 22 -- -- 30 26 -- -- 4.2 1.4 -- -- 5.4 1.6 -- -- 25 21 -- -- 29 24 -- -- 3.3 1.2 -- -- 3.9 1.2 -- -- 3 100 -- -- 2.6 100 -- -- < 21 <18 -- <31 <12 -- -- -- -- -- -- -- 14 - 21 8 - 18 45 26 - 35 15 - 25 70 -- -- 45 -- -- 70 Making and breaking conditions to DC13, time constant as stated. See transparent overlay "Fuses" for time/current characteristics (please enquire). Smoothed DC or three-phase bridge rectifier Electronic Timing Relays, Technical Data and Standards Rating Data for Approved Types OFF ON OFF 15-18 t t Pilot Duty Control Relays -- XTMR A600, P300 Timers -- XTMT, XTTR B300 PG03407001U - June 2006 t t Fleeting Contact on Energization A1-A2 17-18 17-28 A1-A2 t 0.5 s 15-18 LED Flashing, Pulse Initiating t LED ON-OFF Function A1-A2 15-18 t t On-Delayed On-Delayed t A1-A2 15-18 LED LED t A1-A2 15-18 LED Pulse Generating t tu Power LED LED LED Pulse Generating General Use 10A - 600V AC 0.5A - 250V DC 6A - 250V AC Technical details T echn ic al de ta ils A1-A2 83 8 Technical details Miniature Controls Miniature Contactors, Accessories and Overload Relays, dimensional drawings D M4 58 50 [1.97] 35 [1.38] 45 [1.77] D1 Miniature Contactors DOL with overload relay and auxiliary contact XTMC 52 [2.05] 83 [3.27] D D1 XTMCC 54 [2.13] 86 [3.39] 5.5 [.22] 106 49 [4.17] [1.93] 32 [1.26] 45 [1.77] 58 [2.28] 5 [.20] T echn ic al de ta ils Miniature Contactors DOL with overload relay 84 61 [2.40] 108 [4.25] 90 [3.54] 94 [3.70] Miniature Contactors DOL Reversing with overload relay and auxiliary contact Technical details PG03407001U - June 2006 Miniature Contactors, Accessories and Overload Relays, dimensional drawings (Continued) 58 [2.28] 63 [2.48] 58 [2.28] 90 [3.54] 94 [3.70] Miniature Contactors DOL Reversing with Mechanical Interlock 61 [2.40] 108 [4.25] 83 [3.27] 180 [7.09] Miniature Contactors Star Delta with overload relay and auxiliary contact 43 [1.69] 62.5 [2.46] 45 [1.77] 58 [2.28] 45 [1.77] 52 [2.05] 45 [1.77] 69 [2.72] Miniature Contactors fitted with a Sealable Shroud Miniature Contactors fitted with a Suppressor Miniature Contactors, Wiring Diagrams 0 22 II 21 22 22 21 13 14 13 14 14 14 K1M K2M 13 13 22 K1M 22 K2M 21 21 A1 K2M A1 K1M A2 A2 I XTRM Reversing Contactor Control Wiring Diagram PG03407001U - June 2006 K1M 1 3 5 K5M 24 6 A U1 V1 M1 W1 3 M1 13 5 K3M 24 6 C V2 W2 U2 Star Delta Power Wiring Diagram 1 35 1 3 5 246 K1M 13 5 K2M 2 4 6 2 4 6 UV W M1 M 3 T echn ic al de ta ils B 21 XTRM Reversing Contactor Power Wiring Diagram Technical details 85 Miniature Contactors, Eaton Numbering System XT MC C 6 A 10 A Coil Codes Designation A= B= F= T= TD = C= D= E= G= H= L= XT = XT IEC Power Control Type MC = 3-Pole FVNR Mini IEC Contactor MF = 4-Pole FVNR Mini IEC Contactor MR = 3-Pole FVR Mini IEC Contactor Terminations 110V 50 Hz, 120V 60 Hz 220V 50 Hz, 240V 60 Hz 230V 50 Hz 24V 50/60 Hz 24V DC 415V 50 Hz, 480V 60 Hz 550V 50 Hz, 600V 60 Hz 208V 60 Hz 190V 50 Hz, 220V 60 Hz 240V 50 Hz, 277V 60 Hz 380V 50 Hz, 440V 60 Hz N= P= R= U= W= Y= AD = BD = RD = WD = 400V 50 Hz 380V 60 Hz 12V 50/60 Hz 24V 50 Hz 42V 50 Hz, 48V 60 Hz 48V 50 Hz 120V DC 220V DC 12V DC 48V DC Blank = Screw Terminals C = Spring Cage Terminals Integral Auxiliary Contact 01 = 1NC 10 = 1NO Current Rating, AC-3 XTMC 6 = 6.6A 9 = 9.0A Frame Size A = 45 mm Mini XTMF 9 = 9.0A Miniature Overload Relays, Eaton Numbering System XT OM P16 A C1 Trip Class Designation XT = XT IEC Power Control Type OM = Mini Overload Relay C1 = Class 10A Frame Size A = 45 mm Mini Overload Release 0.1 - 0.16A 0.16 - 0.24A 0.24 - 0.4A 0.4 - 0.6A 0.6 - 1A 1 - 1.6A 1.6 - 2.4A 2.4 - 4A 4 - 6A 6 - 9A 9 - 12A T echn ic al de ta ils P16 = P24 = P40 = P60 = 001 = 1P6 = 2P4 = 004 = 006 = 009 = 012 = 86 Technical details PG03407001U - June 2006 Miniature Contactors, Technical Data and Standards, General Specification XTMC6A... XTMC6A... XTMC9A... Coils Coils Coils A-Y AD - WD A-Y IEC/EN 60947, VDE 0660, CSA, UL, CCC XTMC9A... Coils AD - WD XTMF9A... Coils A-Y 0.2 10,000,000 7 9000 0.17 ] 20,000,000 -- 0.2 10,000,000 7 0.17 20,000,000 -- 0.2 20,000,000 7 0.17 -- -- 690 690 690 690 690 690 Impulse Withstand Voltage (Uimp) VAC 6000 6000 6000 6000 6000 6000 Operational Voltage (Ue) VAC 690 690 690 690 690 690 300 300 110 300 300 110 300 300 110 300 300 110 300 300 110 300 300 110 90 90 64 54 90 90 64 54 90 90 64 54 90 90 64 54 90 90 64 54 90 90 64 54 10 20 10 20 10 20 10 20 10 20 10 20 Standards Physical and Electrical Weights in kg Mechanical Life -- Operations Mechanical Life -- Coil @ 50 Hz Maximum mechanical operating frequency (ops/ hr) Insulation Voltage (Ui) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts (VAC) between contacts (VAC) Making Capacity (amps) Breaking Capacity (amps) 220/230V 380/400V 500V 660/690V Short-Circuit Protection rating maximum fuse (gL/ gG) Type 2 Coordination (A) Type 1 Coordination (A) Degree of Protection Protection against direct contact when actuated from front (IEC 536) Terminal Capacity of main and auxiliary contacts Solid (mm2) Flexible with ferrule (mm2) Solid or Stranded (AWG) Terminal Screw Posidrive screwdriver Standard screwdriver (mm) Max. Tightening Torque Nm Terminal Capacity of spring cage main terminals Solid (mm2) Flexible with ferrule (mm2) Standard screwdriver (mm) Mounting Position XTMF9A... Coils AD - WD IP20 Finger- and back-of-hand proof 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18-14 M3.5 Size 2 0.8 x 5.5 1x6 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18-14 M3.5 Size 2 0.8 x 5.5 1x6 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18-14 M3.5 Size 2 0.8 x 5.5 1x6 1 x (0.75 - 2.5) 2 x (0.75 - 2.5 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18-14 M3.5 Size 2 0.8 x 5.5 1x6 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18-14 M3.5 Size 2 0.8 x 5.5 1x6 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) 18-14 M3.5 Size 2 0.8 x 5.5 1x6 1.2 1.2 1.2 1.2 1.2 1.2 1 x (1 - 2.5) 2 x (1 - 2.5) 1 x (1 - 2.5) 2 x (1 - 2.5) 0.6 x 3.5 1 x (1 - 2.5) 2 x (1 - 2.5) 1 x (1 - 2.5) 2 x (1 - 2.5) 0.6 x 3.5 10g -- 10g -- 1 x (1 - 2.5) 1 x (1 - 2.5) 1 x (1 - 2.5) 1 x (1 - 2.5) 2 x (1 - 2.5) 2 x (1 - 2.5) 2 x (1 - 2.5) 2 x (1 - 2.5) 1 x (1 - 2.5) 1 x (1 - 2.5) 1 x (1 - 2.5) 1 x (1 - 2.5) 2 x (1 - 2.5) 2 x (1 - 2.5) 2 x (1 - 2.5) 2 x (1 - 2.5) 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5 As required, except vertical with terminals A1/A2 at the bottom A1 A2 Environmental Ambient Temperature Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms Contactor without auxiliary contact module Main contact -- make contact Main contact -- break/make contact Contactor with auxiliary contact module Main contact -- make contact Main contact -- make/break contact Climatic Proofing Pollution Degree PG03407001U - June 2006 -25 to 50C 10g 10/8g 10g 10/8g 10g 10/8g 10g 10/8g 10g 10g 10g 10g 10g 20/20g 20/20g 20/20g 20/20g 20/20g Damp heat, constant, to IEC 60 068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 III/3 III/3 III/3 III/3 III/3 10g 20/20g T echn ic al de ta ils Description III/3 Technical details 87 Miniature Contactors, Technical Data and Standards, Magnet Systems Description XTMC6A... XTMC6A... Coils Coils A-Y AD - WD XTMC9A... XTMC9A... Coils Coils A-Y AD - WD XTMF9A... XTMF9A... Coils Coils A-Y AD - WD 0.8 - 1.1 0.85 - 1.1 -- -- -- 0.8 - 1.1 0.8 - 1.1 0.85 - 1.1 -- -- -- 0.8 - 1.1 0.8 - 1.1 0.85 - 1.1 -- -- -- 0.85 - 1.1 25 30 29 -- -- -- 25 30 29 -- -- -- 25 30 29 -- -- -- 22 26 24 -- -- -- 22 26 24 -- -- -- 22 26 24 -- -- -- 4.6 5.4 3.9 -- -- -- 4.6 5.4 3.9 -- -- -- 4.6 5.4 3.9 -- -- -- 1.3 1.6 1.1 -- -- -- 1.3 1.6 1.1 -- -- -- 1.3 1.6 1.1 -- -- -- -- 2.6 -- 2.6 -- 2.6 100 100 100 100 100 100 14 21 8 18 max. 45 26 35 15 25 max. 70 14 21 8 18 max. 45 26 35 15 25 max. 70 14 21 8 18 max. 45 26 35 15 25 max. 70 16 21 40 50 16 21 40 50 16 21 40 50 max. 12 max. 12 max. 12 max. 12 max. 12 max. 12 Voltage Tolerance Pick-Up (x Uc) Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Dual frequency coil 50/60 Hz DC operated 1) Power Consumption AC Operation Pick-Up VA Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Dual frequency coil 50/60 Hz at 50 Hz Dual frequency coil 50/60 Hz at 60 Hz Pick-Up W Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Dual frequency coil 50/60 Hz at 50 Hz Dual frequency coil 50/60 Hz at 60 Hz Sealing VA Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Dual frequency coil 50/60 Hz at 50 Hz Dual frequency coil 50/60 Hz at 60 Hz Sealing W Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz Dual frequency coil 50/60 Hz at 50 Hz Dual frequency coil 50/60 Hz at 60 Hz DC operated 1) Power consumption pick-up = sealing (VA/W) Duty Factor (%) Switching Time at 100% Uc Make Contact Closing delay min (mS) Closing delay max (mS) Opening delay min (mS) Opening delay max (mS) Closing delay with top mounting auxiliary contact (mS) Reversing contactors Changeover time at 100% Uc Min (mS) Max (mS) Arcing time at 690V AC (mS) Smoothed DC or three-phase bridge rectifier. T echn ic al de ta ils 1) 88 Technical details PG03407001U - June 2006 Miniature Contactors, Technical Data and Standards, Utilisation ratings Description AC-1 Operation Conventional free air thermal current, 3-pole, 50 - 60 Hz (A) at 40C (Ith) at 50C (Ith) XTMC6A... XTMC6A... Coils Coils A-Y AD - WD XTMC6A... XTMC6A... Coils Coils A-Y AD - WD XTMF9A... Coils A-Y XTMF9A... Coils AD - WD 22 20 19 22 20 19 22 20 19 22 20 19 22 20 19 22 20 19 50 50 50 50 60 60 6.6 6.6 6.6 6.6 6.6 5 3.5 6.6 6.6 6.6 6.6 6.6 5 3.5 9.0 9.0 9.0 9.0 9.0 6.4 4.8 9.0 9.0 9.0 9.0 9.0 6.4 4.8 9.0 9.0 9.0 9.0 9.0 6.4 4.8 9.0 9.0 9.0 9.0 9.0 6.4 4.8 1.5 1.8 3 3.1 3.3 3 3 1.5 1.8 3 3.1 3.3 3 3 2.2 2.5 4 4.3 4.6 4 4 2.2 2.5 4 4.3 4.6 4 4 2.2 2.5 4 4.3 4.6 4 4 2.2 2.5 4 4.3 4.6 4 4 5 5 5 5 5 3.7 2.9 5 5 5 5 5 3.7 2.9 6.6 6.6 6.6 6.6 6.6 5 3.4 6.6 6.6 6.6 6.6 6.6 5 3.4 6.6 6.6 6.6 6.6 6.6 5 3.4 6.6 6.6 6.6 6.6 6.6 5 3.4 1.1 1.3 2.2 2.3 2.4 2.2 2.2 1.1 1.3 2.2 2.3 2.4 2.2 2.2 1.5 1.8 3 3.1 3.3 3 3 1.5 1.8 3 3.1 3.3 3 3 1.5 1.8 3 3.1 3.3 3 3 1.5 1.8 3 3.1 3.3 3 3 at 55C (Ith) Conventional free air thermal current, 1-pole (Ith) AC-3 Operation Rated Operational Current, 50/60 Hz 1) (Ie) in amperes (A) 220/230V 240V 380/400V 415V 440V 500V 660/690V Rated power (P) in kilowatts (kW) 220/230V 240V 380/400V 415V 440V 500V 660/690V AC-4 Operation Rated Operational Current, 50/60 Hz 1) (Ie) in amperes (A) 220/230V 240V 380/400V 415V 440V 500V 660/690V Rated power (P) in kilowatts (kW) 220/230V 240V 380/400V 415V 440V 500V 660/690V At maximum permissible ambient temperature. T echn ic al de ta ils 1) PG03407001U - June 2006 Technical details 89 Miniature Contactors, Technical Data and Standards, Utilisation ratings (Continued) XTMC6A... XTMC6A... Coils Coils A-Y AD - WD XTMC9A... XTMC9A... Coils Coils A-Y AD - WD XTMF9A... XTMF9A... Coils Coils A-Y AD - WD DC-1 Operation 1) 12V 24V 60V 110V 220V 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 -- -- -- -- -- -- -- -- -- -- DC-3 Operation 1) 12V 24V 60V 110V 220V 6 6 3 2 -- 6 6 3 2 -- 8 8 4 3 -- 8 8 4 3 -- -- -- -- -- 1 -- -- -- -- 1 1.8 1.8 1.8 1.1 0.2 1.8 1.8 1.8 1.1 0.2 2.5 2.5 2.5 1.5 0.3 2.5 2.5 2.5 1.5 0.3 -- -- -- 2.5 1 -- -- -- 2.5 1 2 0.3 3.5 0.4 2 0.5 3.5 0.7 2.7 -- 4.7 -- Description DC-4 Operation 1) 12V 24V 60V 110V 220V Current Heat Loss (3- or 4-pole) in watts at Ith at Ie to AC-3/400V 1) Rated operation current (le) in amperes, at maximum permissible ambient temperature. T echn ic al de ta ils Miniature Contactors, Technical Data and Standards, Auxiliary Contacts Description Interlocked opposing contacts to ZH1/457, including auxiliary contact module Rated impulse withstand voltage, Uimp (VAC) Overvoltage category / pollution degree Rated insulation voltage, Ui (VAC) Rated operational voltage, Ue (VAC) Safe isolation to VDE 0106 Part 101 and Part 101(A) in VAC between coil and auxiliary contacts between the auxiliary contacts Rated Operational Current AC-15, Ie XTMC6A... Yes 6000 III/3 690 600 XTMC9A... Yes 6000 III/3 690 600 300 300 300 300 220/240V 380/415V 500V DC-13 (Contacts in Series) 1: 24V 2: 60V 3: 100V 3: 220V Conventional thermal current, Ith Control circuit reliability (at Ue = 24 VDC, Umin = 17 V, I min = 5.4 mA) Component Lifespan at Ue = 240V 6A 3A 1.5A 6A 3A 1.5A 2.5A 2.5A 1.5A 0.5A 10A <10-8, < one failure at 100 million operations 2.5A 2.5A 1.5A 0.5A 10A 0.2 0.15 0.2 0.15 6A 10A 6A 10A 0.2 0.2 AC-15, operations x 106 DC-13 L/R = 50 mS: 2 contacts in series at Ie = 0.5A, operations x 106 Short Circuit rating without welding Short Circuit protection rating maximum fuse, 500V gG/gL Short Circuit protection rating maximum fuse, 500V fast Current heat loss at conventional free air thermal current Ith per contact, W 90 Technical details PG03407001U - June 2006 Miniature Overload Relays Settings Setting Starting A: IN x 0.58 Motor Protection in the Y and Delta Configurations. B: IN x 1 Only partial motor protection in star position C: IN x 0.58 Motor not protected in star position. Timing Relay set to approximately 10 sec. < = 15 sec 15 - 40 sec > 40 sec Miniature Overload Relays,Tripping Characteristic Chart Minutes 2h 100 60 40 XTOM 20 10 6 4 2 1 40 3-Phase Seconds 20 10 6 4 2-Phase 2 1 0.6 1 1.5 2 3 4 6 8 10 15 20 x Setting Current T echn ic al de ta ils These tripping characteristics are mean values of the spread at 20C ambient temperature in a cold state. Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to approx. 25% of the read off value. Specific characteristics for each individual setting range can be found on Page 18. PG03407001U - June 2006 Technical details 91 8 Technical details Standard Contactors, Overload Relays and Starters Standard, 3P Contactors, Frame B, Screw Terminals, dimensional drawings 36 4 x M4 Dia. 18 45 68 60 3.2 8.7 Typ. 35 6.5 5.1 75 45 116.3 Standard, 3P Contactors, Frame B, Cage Terminals, dimensional drawings 68 26.4 4 x M4 Dia. 52.3 60 1.8 3.2 6.5 1.8 8.7 Typ. 35 75 125.2 5.1 45 T echn ic al de ta ils Standard, 3P Contactors, Frame C, dimensional drawings 71 2 x M4 Dia. 38 85 60.4 75 4.5 4.8 17.7 6.4 10.6 4.5 6.5 97.4 35 138.7 11.6 11.6 45 92 Technical details PG03407001U - June 2006 Standard, 3P Contactors, Frame D, dimensional drawings 4 x M4 Dia. 105 104 57 86.4 45 34.4 4.7 55 6.9 113.8 132.1 146.8 Standard, 3P Contactors, Frame F - G, dimensional drawings 4 x M4 Dia. 26.4 40 123.9 170 150 10 30 30 4.0 159 80 174.4 T echn ic al de ta ils 90 PG03407001U - June 2006 Technical details 93 Standard, 3P Contactors, Frame L - M, dimensional drawings W1 W 11 Dia. M6 Dia. H2 H3 H1 H W2 D1 W4 140 8 D W Frame L 140 (185 - 250A) Frame M 160 (300 - 500A) W1 W2 W3 W4 H H1 H2 H3 D D1 160 120 20 48 180 164 189 160 208 5 180 130 25 48 200 184 209 180 216 6 Standard, 3P Contactors, Frame N, dimensional drawings A Dia. M6 Dia. 232 256 215 H T echn ic al de ta ils 165 94 D1 W 80 140 250 232 270 XTCE580N XTCE650N XTCE750N XTCE820N XTCEC10N Technical details W 35 35 45 45 45 H 286 286 296 296 296 D1 6 6 6 6 10 A (Dia.) 11 11 13.5 13.5 13.5 PG03407001U - June 2006 Standard, 3P Contactors, Frame P, dimensional drawings M6 Dia. 342 210 256 232 215 308 165 10 130 60 100 232 100 260 Standard, 3P Contactors, Frame R, dimensional drawings 392 210 300 272 352 10 150 80 80 150 125 172.5 252 40 172.5 T echn ic al de ta ils 14 Dia 40 515 M6 Dia. 270 430 PG03407001U - June 2006 Technical details 95 Standard, 3P Contactors, Frames B - G, DOL Reversing, dimensional drawings H W Frame B (7 - 15A) W H 90 68 D 125.2 D Frame C (18 - 32A) W H 90 85 D 147.3 Frame D (40 - 65A) W H 110 115 D 146.8 Frame F - G (80 - 150A) W H D 180 170 174.4 Standard, 3P Contactors, Frames L - M, Mechanical Interlock, dimensional drawings 15 Frame L - M. XTCEXMLM Mechanical Interlock T echn ic al de ta ils 515 430 96 20 270 300 9 XTCEXMLM Technical details PG03407001U - June 2006 Standard, 3P Contactors, Frames L - N, with Terminal Shrouds W H Frame L - N Contactors, XTCE185L - XTCEC10N, with Terminal Shroud XTLEXTS XTCE185L, XTCE225L, XTCE250L W 150 XTCE300M, XTCE400M H 384 W 150 XTCE500M H 404 W 174 H 426 XTCE580N, XTCE650N, XTCE750N, XTCE820N, XTCEC10N W H 236 506 Standard, 3P Contactors, Frames L - N, Cable Terminal Block, dimensional drawings H XTCE185L - XTCE250L 198 PG03407001U - June 2006 222 30 XTCE300M - XTCE400M 218 T echn ic al de ta ils 135 Technical details 97 Standard, 3P Contactors, Frames M - N, Flat Strip Conductor Terminals H W W 171 218 231 XTCE500M XTCE580N - XTCE650N XTCE750N - XTCE820N H 232 295 310 Standard, 3P Contactors, Frames B - F, Suppressor, dimensional drawing 32 Approx. 28 9.2 9 T echn ic al de ta ils 25 98 Technical details PG03407001U - June 2006 Standard, Overload Relays, Frame B - C, dimensional drawings 35.5 29.5 48 39.5 65 83 45 Standard, Overload Relays, Frame D, dimensional drawings 20.3 51.5 79.2 95.5 102 60 Standard, Overload Relays, Frame B - C & D, DIN Rail or Panel Mount Adapter , dimensional drawing D1 42.5 H 5 H 85 86 PG03407001U - June 2006 W 45 60 D 90.5 112 D1 58.3 80.5 D2 3.8 4.7 T echn ic al de ta ils XTOB...CC1 XTOB...DC1 D2 Technical details 99 Standard, Overload Relay, Frames F - G, dimensional drawing 99 80 73 138 74 63 95 100 118 129 134 Standard, Overload Relay, Frame L, dimensional drawing 110 121 144 96 48 111 144 ** * 74 7 5* 94 169 7 Dia. 25 ** 16.5 11 Dia. * = OFF ** = RESET/ON T echn ic al de ta ils 128 100 Technical details PG03407001U - June 2006 Standard, Overload Relay, Current Transformer Operated, dimensional drawing 185 1.5 5 4.3 8 21 71 44 33 55 26 85 159 172 - 250 185 44 M4 26 55 * * = RESET/ON 200 65 65 71 27 90 90 90 T echn ic al de ta ils XTOT...C3S PG03407001U - June 2006 Technical details 101 Standard, Overload Relays, Frames B - F, Fitting, Overviews Frame B - Overload Relay Fitted Directly to the Contactor Frame C - Overload Relay Fitted Directly to the Contactor Frame C - Overload Relay Fitted Seperatley from the Contactor T echn ic al de ta ils Frame D - Overload Relay Fitted Directly to the Contactor 102 Technical details Frame D - Overload Relay Mounted Seperatly from the Contactor Frame F -G - Overload Relay Fitted Directly from the Contactor PG03407001U - June 2006 Standard Starters, DOL, Frame B, dimensional drawings Mounting Holes for M4 or #8 Screws (4 Places) 45.3 35 117.1 75.8 60 117.8 83.3 88.4 To Reset Standard Starters, DOL, Frame C, dimensional drawings Mounting Holes for M4 or #8 Screws (2 Places) 45 35 139.8 97.8 75 136.4 100.2 105.3 To Reset Standard Starters, DOL, Frame D, dimensional drawings 60 146 132.5 Screws 105 T echn ic al de ta ils 45 Mounting Holes for 174 93.6 98 To Reset PG03407001U - June 2006 Technical details 103 Standard Starters, DOL, Frames F - G, dimensional drawings 90 70 160 150 57 156 170 277 91 74 95 100 118 7 Dia. 134 Standard Starters, DOL, Frame L, dimensional drawings 150 T echn ic al de ta ils 110 523 328 34 144 104 Technical details PG03407001U - June 2006 Standard Contactors & Starters, Eaton Numbering System XT CE C 007 B 01 AD P16 Designation Maximum Overload Rating XT = XT Line of IEC Control XTAE, XTAS and XTAR Starters Only Frame B P16 = 0.1 - 0.16A P24 = 0.16 - 0.24A P40 = 0.24 - 0.4A P60 = 0.4 - 0.6A 001 = 0.6 - 1A 1P6 = 1.0 - 1.6A 2P4 = 1.6 - 2.4A 004 = 2.4 - 4A 006 = 4 - 6A 010 = 6 - 10A 012 = 9 - 12A 016 = 12 - 16A Type 3-Pole FVNR IEC Contactor 3-Pole FVNR S Series IEC Contactor 4-Pole FVNR IEC Contactor 3-Pole FVR IEC Contactor IEC Capacitor Contactor FVNR IEC Starter FVNR S-Series IEC Starter FVR IEC Starter Terminations Blank = Screw Terminals (6 - 65A); 5 mm (80 - 150A); No Lugs (185 - 2000A) C = Spring Cage Terminals (6 - 32A); Spring Cage Coil Terminals Only (185 - 2000A) Current Ratings, AC-3 Frame Size Designation 007 = 009 = 012 = 015 = 7A 9A 12A 15A B= 45 mm 018 = 025 = 032 = 18A 25A 32A C= 45 mm 040 = 050 = 065 = 40A 50A 65A D = 55 mm 080 = 095 = 80A 95A F= Auxiliary Contact 01 = 1NC 10 = 1NO 00 = 0NO-0NC 90 mm 115 = 115A 150 = 150A G = 90 mm 185 = 185A 225 = 225A L= 250 = 300 = 400 = 500 = 250A 300A 400A 500A M = 160 mm 580 = 650 = 750 = 820 = C10 = 580A 650A 750A 820A 1000A N = 250 mm Frame C P16 = 0.1 - 0.16A P24 = 0.16 - 0.24A P40 = 0.24 - 0.4A P60 = 0.4 - 0.6A 001 = 0.6 - 1A 1P6 = 1.0 - 1.6A 2P4 = 1.6 - 2.4A 004 = 2.4 - 4A 006 = 4 - 6A 010 = 6 - 10A 016 = 10 - 16A 024 = 16 - 24A 032 = 24 - 32A Frame D 010 = 6 - 10A 016 = 12 - 16A 024 = 16 - 24A 040 = 24 - 40A 057 = 40 - 57A 065 = 50 - 65A Frame L 070 = 50 - 70A 100 = 70 - 100A 125 = 95 - 125A 160 = 120 - 160A 220 = 160 - 220A 250 = 200 - 250A Frame M 063 = 42 - 63A 090 = 60 - 90A 125 = 85 - 125A 160 = 110 - 160A 240 = 160 - 240A 290 = 190 - 290A 400 = 270 - 400A 540 = 360 - 540A Frame N 063 = 42 - 63A 090 = 60 - 90A 125 = 85 - 125A 160 = 110 - 160A 240 = 160 - 240A 290 = 190 - 290A 400 = 270 - 400A 540 = 360 - 540A 630 = 420 - 630A Frame F 035 = 25 - 35A 050 = 35 - 50A 070 = 50 - 70A 100 = 70 - 100A Coil Codes 140 mm C14 = 1400A, AC-1 P = 260 mm C16 = 1600A, AC-3 R = 515 mm C20 = 2000A, AC-1 R = 515 mm 22 = 2NO-2NC T echn ic al de ta ils CE = CS = CF = CR = CC = AE = AS = AR = Frame G 035 = 25 - 35A 050 = 35 - 50A 070 = 50 - 70A 100 = 70 - 100A 125 = 95 - 125A 150 = 120 - 150A PG03407001U - June 2006 Technical details 105 Standard Contactors, Frame B, Technical Data and Standards Description Standards General Weights in kg AC operated DC operated Mechanical Life Mechanical Operating Frequency (ops/hr) AC operated DC operated Maximum Operating Frequency (ops/hr) Mechanical Operating Frequency (ops/hr) AC-1; 400V I e AC-3; 400V I e AC-4; 400V I e Climatic Proofing Insulation Voltage (Ui) VAC Impulse Withstand Voltage (Uimp) VAC Operational Voltage (Ue) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (VAC) Between contacts (VAC) Making Capacity (Amps) Breaking Capacity (Amps) 220/230V 380/400V 500V 660/690V Short-Circuit Protection Rating Maximum Fuse Type 2 Coordination 400V; gG/gL 500V 690V; gG/gL 690V Type 1 Coordination 400V; gG/gL 500V 690V; gG/gL 690V Degree of Protection Protection against Direct Contact when Actuated from Front (IEC 536) Main Cable Cross-Section Solid (mm2) Flexible with ferrule (mm2) Solid or Stranded (AWG) Main Cable Connection Screw/Bolt Tightening torque Nm Control Circuit Cable Cross-Sections T echn ic al de ta ils Solid (mm2) 106 Flexible with ferrule (mm2) Solid or Stranded (AWG) Main Cable Connection Screw/Bolt Tightening torque Nm Tools Pozidrive screwdriver Standard screwdriver Technical details XTCE007B XTCE009B IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS XTCE012B XTCE015B 0.23 0.28 10,000,000 0.23 0.28 10,000,000 0.23 0.28 10,000,000 0.23 0.28 10,000,000 9000 9000 9000 9000 9000 9000 9000 9000 800 800 800 800 1000 1000 1000 1000 300 300 300 300 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 690 690 690 690 8000 8000 8000 8000 690 690 690 690 400 400 108 400 400 108 400 400 144 400 400 155 70 70 50 40 90 90 70 50 120 120 100 70 124 124 100 70 20 16 20 16 20 20 20 20 35 35 20 20 IP20 Finger- and back-of-hand proof 35 20 63 50 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 1 x (0.75 - 2.5) 18 - 14 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 Size 2 0.8 x 5.5 Size 2 0.8 x 5.5 Size 2 0.8 x 5.5 Size 2 0.8 x 5.5 PG03407001U - June 2006 Standard Contactors, Frame B, Technical Data and Standards (Continued) Description Standards General (Continued) XTCE007B XTCE009B IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS Mounting Position, AC and DC Operated 30 90 90 90 180 90 90 180 11 to 40C -25 to 60C -40 to 80C 11 to 40C -25 to 60C -40 to 80C 11 to 40C -25 to 60C -40 to 80C 11 to 40C -25 to 60C -40 to 80C 10g 7g 5g III/3 10g 7g 5g III/3 10g 7g 5g III/3 10g 7g 5g III/3 Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated. Standard Contactors, Frame C - D, Technical Data and Standards Description Standards General Weights in kg AC operated DC operated Mechanical Life Mechanical Operating Frequency (ops/hr) AC operated DC operated Electrical Operating Frequency (ops/hr) AC-1; 400V I e AC-3; 400V I e AC-4; 400V I e Climatic Proofing Insulation Voltage (Ui) VAC Impulse Withstand Voltage (Uimp) VAC Operating Voltage (Ue) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (VAC) Between contacts (VAC) Making Capacity (Amps) Breaking Capacity (Amps) 220/230V 380/400V 500V 660/690V Short-Circuit Protection Rating Maximum Fuse Amps Type 2 Coordination 400V; gG/gL 500V 690V; gG/gL 690V Type 1 Coordination 400V; gG/gL 500V 690V; gG/gL 690V Degree of Protection Protection against Direct Contact when Actuated from Front (IEC 536) PG03407001U - June 2006 XTCE018C XTCE025C XTCE032C IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS XTCE040D XTCE050D XTCE065D 0.42 0.48 10,000,000 0.42 0.48 10,000,000 0.42 0.48 10,000,000 0.9 1.1 10,000,000 0.9 1.1 10,000,000 0.9 1.1 10,000,000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 800 800 800 800 800 800 300 300 300 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 690 690 690 8000 8000 8000 690 690 690 800 800 300 800 800 300 800 800 300 690 8000 690 690 8000 690 690 8000 690 440 238 238 440 440 350 440 440 384 440 440 560 440 440 700 440 440 910 170 170 170 120 250 250 250 150 320 320 320 180 400 400 400 250 500 500 500 320 650 650 650 370 25 25 35 35 63 35 63 50 80 63 125 80 125 80 160 80 250 100 63 100 125 50 50 63 IP00 Finger- and back-of-hand proof Technical details T echn ic al de ta ils 1) XTCE015B 30 90 Ambient Temperature: Enclosed Open Ambient Storage Temperature Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS Main contact -- NO Contact Auxiliary contact -- NO Contact Auxiliary contact -- NC Contact Overvoltage Category/Pollution degree XTCE012B 107 Standard Contactors, Frame C - D, Technical Data and Standards (Continued) Description Standards General Main Cable Cross-Section Solid (mm2) Flexible with ferrule (mm2) Solid or Stranded (AWG) Flat Conductor (Number of Segments x Width x Thickness) Main Cable Connection Screw/Bolt Tightening torque Nm Control Circuit Cable Cross-Sections Solid (mm2) Flexible with ferrule (mm2) Solid or Stranded (AWG) Control Circuit Cable Connection Screw/Bolt Tightening torque Nm Tools Main and control circuit cable Pozidrive screwdriver Standard screwdriver Mounting Position, AC and DC operated XTCE018C XTCE025C XTCE032C IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS XTCE040D XTCE050D XTCE065D 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x (0.75 - 16) 2 x (0.75 - 10) 18 - 6 -- 1 x (2.5 - 16) 2 x (2.5 - 16) 1 x (2.5 - 35) 2 x (2.5 - 25) 18 - 6 1 x (2.5 - 16) 2 x (2.5 - 16) 1 x (2.5 - 35) 2 x (2.5 - 25) 18 - 6 1 x (2.5 - 16) 2 x (2.5 - 16) 1 x (2.5 - 35) 2 x (2.5 - 25) 18 - 6 2 x (6 x 9 x 0.8) M6 2 x (6 x 9 x 0.8) M6 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x (0.75 - 16) 2 x (0.75 - 10) 18 - 6 -- 1 x (0.75 - 16) 2 x (0.75 - 10) 1 x (0.75 - 16) 2 x (0.75 - 10) 18 - 6 -- M5 M5 M5 2 x (6 x 9 x 0.8) M6 3 3 3 3 3 3 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M3.5 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M3.5 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M3.5 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 12 - 2 M3.5 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 12 - 2 M3.5 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 12 - 2 M3.5 1.2 1.2 1.2 1.2 1.2 1.2 Size 2 0.8 x 5.5 1x6 Size 2 0.8 x 5.5 1x6 Size 2 0.8 x 5.5 1x6 Size 2 0.8 x 5.5 1x6 Size 2 0.8 x 5.5 1x6 Size 2 0.8 x 5.5 1x6 90 90 90 180 180 90 -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C 10 7 5 III/3 10 7 5 III/3 10 7 5 III/3 10 7 5 III/3 10 7 5 10 7 5 T echn ic al de ta ils Ambient Temperature Ambient Storage Temperature Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Main contact -- NO Contact Auxiliary contact -- NO Contact Auxiliary contact -- NC Contact Overvoltage Category / Pollution Degree 30 30 90 108 Technical details PG03407001U - June 2006 Standard Contactors, Frame F - G, Technical Data and Standards Degree of Protection Protection Against Direct Contact when Actuated from Front (IEC 536) Main Cable Cross-Section XTCE115G XTCE150G 4.41 4.63 10,000 4.41 4.63 10,000 4.41 4.63 10,000 4.41 4.63 10,000 3600 3600 3600 3600 3600 3600 3600 3600 800 800 800 800 800 800 800 800 300 300 300 300 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 1000 1000 1000 1000 8000 8000 8000 8000 1000 1000 1000 1000 690 690 1120 690 690 1330 690 690 1610 690 690 2100 800 800 800 650 1200 950 950 950 800 1200 1150 1150 1150 1100 1200 1500 1500 1500 1200 1200 160 160 160 160 250 250 1) 1) 250 200 250 200 250 250 1) 1) IP00 Finger- and back-of-hand proof Solid (mm2) -- -- -- -- Flexible with ferrule (mm2) 1 x (10 - 95) 2 x (10 - 70) 1 x (16 - 120) 2 x (16 - 95) 10 - 250ACM 2 x (6 x 16 x 0.8) 1 x (10 - 95) 2 x (10 - 70) 1 x (16 - 95) 2 x (16 - 70) 10 - 250ACM 2 x (6 x 16 x 0.8) 1 x (10 - 95) 2 x (10 - 70) 1 x (16 - 120) 2 x (16 - 95) 8 - 250 MCM 2 x (6 x 16 x 0.8) 1 x (10 - 95) 2 x (10 - 70) 1 x (16 - 120) 2 x (16 - 95) 8 - 250 MCM 2 x (6 x 16 x 0.8) M10 14 M10 14 M10 14 M10 14 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 1 x (0.75 - 4) 1 x (0.75 - 4) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 18 - 14 M3.5 1.2 M3.5 1.2 M3.5 1.2 M3.5 1.2 Stranded (mm2) Solid or Stranded (AWG) Flat Conductor (Number of Segments x Width x Thickness) Main Cable Connection Screw/Bolt Tightening torque Nm Control Circuit Cable Cross-Sections Solid (mm2) Flexible with ferrule (mm2) Solid or Stranded (AWG) Control Circuit Cable Connection Screw/Bolt Tightening torque Nm 1) XTCE080F XTCE095F IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS Contact Eaton. PG03407001U - June 2006 Technical details T echn ic al de ta ils Description Standards General Weights in kg AC operated DC operated Mechanical Life Mechanical Operating Frequency (ops/hr) AC operated DC operated Electrical Operating Frequency (ops/hr) AC-1; 400V I e AC-3; 400V I e AC-4; 400V I e Climatic Proofing Insulation Voltage (Ui) VAC Impulse Withstand Voltage (Uimp) VAC Operational Voltage (Ue) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (VAC) Between contacts (VAC) Making Capacity (Amps) Breaking Capacity (Amps) 220/230V 380/400V 500V 660/690V 1000V Short-Circuit Protection Rating Maximum Fuse Type 2 Coordination 400V; gG/gL 500V 690V; gG/gL 690V Type 1 Coordination 400V; gG/gL 500V 690V; gG/gL 690V 109 Standard Contactors, Frame F - G, Technical Data and Standards (Continued) XTCE080F XTCE095F IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS XTCE115G XTCE150G 5mm Allen Key Size 2 0.8 x 0.55 5mm Allen Key Size 2 0.8 x 0.55 5mm Allen Key Size 2 0.8 x 0.55 5mm Allen Key Size 2 0.8 x 0.55 30 90 180 90 Enclosed Open Ambient Storage Temperature Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS Main contact -- NO Contact Auxiliary contact -- NO Contact Auxiliary contact -- NC Contact Overvoltage Category/Pollution Degree 90 90 90 -25 to 40C -25 to 60C -40 to 80C -25 to 40C -25 to 60C -40 to 80C -25 to 40C -25 to 60C -40 to 80C -25 to 40C -25 to 60C -40 to 80C 10g 7g 5g III/3 10g 7g 5g III/3 10g 7g 5g III/3 10g 7g 5g III/3 T echn ic al de ta ils Ambient Temperature: 30 90 180 Description Standards General Tools Main and control circuit cable Pozidrive screwdriver Standard screwdriver Mounting Position, AC and DC operated 110 Technical details PG03407001U - June 2006 Standard Contactors, Frame L - M, Technical Data and Standards Flexible with cable lug (mm2) Stranded with cable lug (mm2) Solid or Stranded (AWG) Flat Conductor (mm) Busbar -- Width in mm Main Cable Connection Screw/Bolt Tightening torque Nm Lb-in Control Circuit Cable Cross-Sections Solid (mm2) Flexible with ferrule (mm2) Solid or Stranded (AWG) Control Circuit Cable Connection Screw/Bolt Tightening torque Nm Tools Main cable wrench Control circuit cable pozidrive screwdriver 1) XTCE185L XTCE225L XTCE250L IEC/EN 60947, VDE 0660, UL, CSA XTCE300M XTCE400M XTCE500M 6.5 10,000,000 8 7000000 8 7000000 8 7000000 6.5 10,000,000 6.5 10,000,000 3000 3000 3000 2000 2000 3000 3000 3000 2000 2000 See page 115. Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 1000 1000 1000 1000 1000 8000 8000 8000 8000 8000 1000 1000 1000 1000 1000 1000 8000 1000 500 500 500 500 500 500 500 500 500 500 500 500 3000 3000 3000 5500 5500 5500 2500 2500 2500 2500 760 2500 2500 2500 2500 760 2500 2500 2500 2500 760 5000 5000 5000 5000 950 5000 5000 5000 5000 950 5000 5000 5000 5000 950 315 315 160 315 315 160 315 315 160 500 500 200 500 500 200 500 500 200 400 400 400 630 630 400 400 400 630 630 200 200 200 250 250 IP00 Finger- and back-of-hand proof with terminal shroud or terminal block. 2000 2000 630 630 250 50 - 240 70 - 240 1/0 - 250 50 - 240 70 - 240 1/0 - 250 50 - 240 70 - 240 1/0 - 250 50 - 240 70 - 240 1/0 - 250 50 - 240 70 - 240 1/0 - 250 MCM 1) 20 MCM 1) 25 MCM 1) 25 MCM 1) 25 MCM 1) 30 M10 M10 M10 M10 M10 24 213 24 213 24 213 24 213 24 213 24 213 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 1.2 1.2 1.2 1.2 1.2 1.2 16 mm Size 2 16 mm Size 2 16 mm Size 2 16 mm Size 2 16 mm Size 2 16 mm Size 2 35 - 95 50 - 120 20 M10 Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks. PG03407001U - June 2006 Technical details T echn ic al de ta ils Description Standards General Weights in kg Mechanical Life Mechanical Operating Frequency (ops/hr) AC operated DC operated Mechanical Operating Frequency (ops/hr) Climatic Proofing Insulation Voltage (Ui) VAC Impulse Withstand Voltage (Uimp) VAC Operating Voltage (Ue) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/ A1 Between coil and contacts (VAC) Between contacts (VAC) Making Capacity (Amps) Breaking Capacity (Amps) 220/230V 380/400V 500V 660/690V 1000V Short-Circuit Protection Rating Maximum Fuse Type 2 Coordination 400V; gG/gL 500V 690V; gG/gL 690V 1000V; gG/gL 1000V Type 1 Coordination 400V; gG/gL 500V 690V; gG/gL 690V 1000V; gG/gL 1000V Degree of Protection Protection Against Direct Contact when Actuated from Front (Iec 536) Main Cable Cross-Section 111 Standard Contactors, Frame L - M, Technical Data and Standards (Continued) Description General (Continued) Mounting Position, AC and DC Operated XTCE185L XTCE225L XTCE250L XTCE300M 30 90 XTCE400M XTCE500M 30 30 90 90 30 90 180 Ambient Temperature Ambient Storage Temperature -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS Main contact -- NO Contact Auxiliary contact -- NO Contact Auxiliary contact -- NC Contact Overvoltage Category/ Pollution Degree 10g 10g 8g 10g 10g 8g 10g 10g 8g 10g 10g 8g 10g 10g 8g 10g 10g 8g III/3 III/3 III/3 III/3 III/3 III/3 87 150 190 150 -- -- -- -- -- -- -- -- 115 200 265 200 -- -- -- -- -- -- -- -- 80 150 200 260 100 175 230 300 110 190 260 340 130 225 290 390 160 280 370 480 160 280 370 480 66 115 145 115 -- -- -- -- -- -- -- -- 85 150 195 150 -- -- -- -- -- -- -- -- Switching Capacity, kvar 1) Individual Compensation 230V 400/420/440V 525V 690V Group Compensation, with Choke 230V 400/420/440V 525V 690V Group Compensation, without Choke 230V 400/420/440V 525V 690V When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an air-cored coil with 5 windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase. T echn ic al de ta ils 1) 112 Technical details PG03407001U - June 2006 Standard Contactors, Frame N - R, Technical Data and Standards Description XTCE580N Standards General Weights in kg Mechanical Life Mechanical Operating Frequency (ops/hr) AC operated DC operated Maximum Operating frequency (ops/hr) Climatic Proofing Insulation Voltage (Ui) VAC Impulse Withstand Voltage (Uimp) VAC Operating Voltage (Ue) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between coil and contacts (VAC) Between contacts (VAC) Making Capacity (Amps) Breaking Capacity (Amps) 220/230V 380/400V 500V 660/690V 1000V Short-Circuit Protection Rating Maximum Fuse Type 2 Coordination 400V; gG/gL 500V 690V; gG/gL 690V 1000V; gG/gL 1000V Type 1 Coordination 400V; gG/gL 500V 690V; gG/gL 690V 1000V; gG/gL 1000V Degree of Protection Protection Against Direct Contact when Actuated from Front (Iec 536) Main Cable Cross-Section IEC/EN 60947, VDE 0660, UL, CSA Stranded with cable lug (mm2) Solid or Stranded (AWG) Flat Conductor (mm) Busbar -- Width in mm Main Cable Connection Screw/Bolt Tightening torque Nm Control Circuit Cable Cross-Sections Solid (mm2) Flexible with ferrule (mm2) Solid or Stranded (AWG) Control Circuit Cable Connection Screw/Bolt Tightening torque Nm 1) 15 5,000,000 XTCE750N, XTCE820N, XTCEC10N XTCEC14P, XTCEC20R 15 5,000,000 15 5,000,000 15, 32 5,000,000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 See page 115. Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30 1000 1000 1000 1000 1000 8000 8000 8000 8000 8000 1000 1000 1000 1000 1000 500 500 7800 500 500 7800 500 500 9840 500 500 9840 500 500 9840 6500 6500 6500 6500 4350 6500 6500 6500 6500 4350 8200 8200 8200 8200 5800 8200 8200 8200 8200 5800 8200 8200 8200 8200 5800 630 630 500 630 630 500 630 630 630 630 630 630 -- -- -- 1000 1000 1200 1200 1000 1000 1200 1200 630 630 800 800 IP00 Finger- and back-of-hand proof with terminal shroud or terminal block. -- -- -- 50-240 50-240 50-240 50-240 50-240 70-240 2/0 - 500 MCM 70-240 2/0 - 500 MCM 70-240 2/0 - 500 MCM 70-240 2/0 - 500 MCM 70-240 2/0 - 500 MCM 1) 1) 1) 1) 1) 50 M10 50 M10 50 M12 50 M12 50 M12 24 24 35 35 35 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 M3.5 M3.5 M3.5 M3.5 1.2 1.2 1.2 1.2 1.2 Screw tightening with flat cable terminal or cable terminal blocks. See terminal capacity for cable terminal blocks. PG03407001U - June 2006 Technical details T echn ic al de ta ils Flexible with cable lug (mm2) 15 5,000,000 XTCE650N 113 Standard Contactors, Frame N - R, Technical Data and Standards (Continued) Description General (Continued) Tools Main cable wrench Control circuit cable pozidrive screwdriver Mounting Position, AC and DC Operated XTCE580N XTCE650N XTCE750N, XTCE820N, XTCEC10N XTCEC14N, XTCEC20N 16 mm Size 2 16 mm Size 2 18 mm Size 2 18 mm Size 2 18 mm Size 2 30 90 30 30 90 90 30 90 180 -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C -25 to 60C -40 to 80C 10 10 8 III/3 10 10 8 III/3 10 10 8 III/3 10 10 8 III/3 10 10 8 III/3 Switching Capacity, kvar 1) Individual Compensation 230V 400/420/440V 525V 690V 175 300 400 300 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- When using contactors for group compensation, a minimum inductance of approx. 6 uh per capacitor must be available to limit the high inrush current peaks. This corresponds to an air-cored coil with 5 windings and a coil diameter of approximately 140 mm. The conductor cross-section must be selected according to the rated current per phase. T echn ic al de ta ils 1) Ambient Temperature Ambient Storage Temperature Environmental Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 mS (g) Main contact -- NO Contact Auxiliary contact -- NO Contact Auxiliary contact -- NC Contact Overvoltage Category/Pollution Degree 114 Technical details PG03407001U - June 2006 Standard Contactors, Frame L - N, Utilisation Categories, (400V) Maximum Operating Frequency Type AC-1 AC-3 AC-4 XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE580N XTCE650N XTCE750N XTCE820N 2 2 2 3 3 3 3 3 3 3 1 1 1 2 2 2 4 4 4 4 6 6 6 7 7 7 5 5 5 5 Ops./h 4000 3000 2000 1500 1000 800 600 500 400 300 200 150 100 0 10 20 30 40 50 60 70 80 90 100 % PN [kW] T echn ic al de ta ils 50 PG03407001U - June 2006 Technical details 115 Standard Contactors, Frames B - R, AC1, 3, 4, 6A and 6B Electrical Indurance Ratings Description XTCE007B XTCE009B XTCE012B XTCF020B XTCE015B XTCE018C XTCE025C XTCE032C AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 - 60 Hz at 40C (Ith) 22A 22A 22A 22A 40A 45A 45A at 50C (Ith) 21A 21A 21A 21A 38A 43A 43A at 55C (Ith) 21A 21A 21A 21A 37A 42A 42A at 60C (Ith) 20A 20A 20A 20A 35A 40A 40A 18A 50A 18A 50A 18A 50A 18A 50A 32A 85A 36A 85A 36A 85A 45A 45A 45A 45A 80A 80A 80A 7 7 7 7 7 5 4 -- 9 9 9 9 9 7 5 -- 12 12 12 12 12 10 7 -- 15.5 15.5 15.5 15.5 15.5 12.5 9 -- 18 18 18 18 18 18 12 -- 25 25 25 25 25 25 15 -- 32 32 32 32 32 32 18 -- 2.2 2.2 3 4 4.5 3.5 3.5 -- 2.5 3 4 5.5 5.5 4.5 4.5 -- 3.5 4 5.5 7 7.5 7 6.5 -- 4 4.6 7.5 8 8.4 7.5 7 -- 5 5.5 7.5 10 10.5 12 11 -- 7.5 8.5 11 14.5 15.5 17.5 14 -- 10 11 15 19 20 23 17 -- 5 5 5 5 5 4.5 4 -- 6 6 6 6 6 5 4.5 -- 7 7 7 7 7 6 5 -- 7 7 7 7 7 6 5 -- 10 10 10 10 10 10 8 -- 13 13 13 13 13 13 10 -- 15 15 15 15 15 15 12 -- 1 1.5 2.2 2.3 2.4 2.5 2.9 -- 1.5 1.6 2.5 2.8 3 2.8 3.6 -- 2 2.2 3 3.4 3.6 3.5 4.4 -- 2 2.2 3 3.4 3.6 3.5 4.4 -- 2.5 3 4.5 5 5.5 6 6.5 -- 3.5 4 6 6.5 7 8 8.5 -- 4 4.5 7 7.5 8 9 10 -- Enclosed Conventional Free Air Thermal Current, 1-Pole (Ith) Enclosed AC-3 Operation T echn ic al de ta ils Rated Operational Current, 50/60 Hz1) (Ie) in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-4 Operation Rated Operational Current, 50/60 Hz1) (Ie) in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-6A Operation Transformer Loads AC-6B Operation Capacitor Loads Individual compensation rated operational current Ie of three-phase capacitors in amperes Up to 525V 690V Maximum inrush current peak (x Ie) Component Lifesaving (Operations) Maximum Operating Frequency (ops/hr) Values are application specific. Calculation is IeAC-3 = X / 6 *leTransformer where the X is the inrush current of the transformer and leTransformer is the nominal current. 2) -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1) At maximum permissible ambient temperature. 2) Example -- The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. 116 Technical details PG03407001U - June 2006 Standard Contactors, Frames B - R, AC1, 3, 4, 6A and 6B Electrical Indurance Ratings (Continued) Description AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 - 60 Hz Open at 40C (Ith) XTCE040D XTCE050D XTCE065D XTCE080F XTCE095F XTCE115G XTCE150G 60A 80A 98A 110A 130A 160A 190A at 50C (Ith) 57A 71A 88A 88A 125A 142A 180A at 55C (Ith) 55A 66A 83A 94A 115A 135A 170A at 60C (Ith) 50A 65A 80A 90A 110A 130A 160A 45A 58A 72A 80 100A 115A 144A 125A 112A 162A 145A 200A 150A 225A 200A 275A 250A 325A 285A 400A 360A 40 40 40 40 40 40 25 -- 50 50 50 50 50 50 32 -- 65 65 65 65 65 65 37 -- 80 80 80 80 80 80 65 -- 95 95 95 95 95 95 80 -- 115 115 115 115 115 115 93 -- 150 150 150 150 150 150 100 -- 12.5 13.5 18.5 24 25 28 23 -- 15.5 17 22 30 32 36 30 -- 20 22 30 39 41 47 35 -- 25 27.5 37 43 51 58 63 -- 30 34 45 57 60 70 75 -- 37 40 55 70 75 85 90 -- 48 52 75 91 95 110 96 -- 18 18 18 18 18 18 14 -- 21 21 21 21 21 21 17 -- 25 25 25 25 25 25 20 -- 40 40 40 40 40 40 40 -- 50 50 50 50 50 50 50 -- 55 55 55 55 55 55 45 -- 65 65 65 65 65 65 50 -- 5 5.5 9 9.5 10 11 12 -- 6 6.5 10 11 12 13 14 -- 7 7.5 12 13 14 16 17 -- 12 13 20 24 25 29 26 -- 16 17 26 30 32 36 35 -- 17 19 28 33 35 40 45 -- 20 22 33 39 41 47 48 -- Enclosed Conventional Free Air Thermal Current, 1-Pole (Ith) Open Enclosed Rated Operational Current, 50/60 Hz1) (Ie) in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-4 Operation Rated Operational Current, 50/60 Hz1) (Ie) in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-6A Operation Transformer Loads AC-6B Operation Capacitor Loads Individual compensation rated operational current Ie of three-phase capacitors in amperes Up to 525V 690V Maximum inrush current peak (x Ie) Component Lifesaving (Operations) Maximum Operating Frequency (ops/hr) Values are application specific. Calculation is IeAC-3 = X / 6 *leTransformer where the X is the inrush current of the transformer and leTransformer is the nominal current. 2) -- -- 30 -- -- -- -- 30 -- -- -- -- 30 -- -- -- -- 30 -- -- -- -- 30 -- -- -- -- 30 -- -- -- -- 30 -- -- T echn ic al de ta ils AC-3 Operation 1) At maximum permissible ambient temperature. 2) Example -- The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. PG03407001U - June 2006 Technical details 117 Standard Contactors, Frames B - R, AC1, 3, 4, 6A and 6B Electrical Indurance Ratings (Continued) Description AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 - 60 Hz at 40C (Ith) at 50C (Ith) at 55C (Ith) at 60C (Ith) Conventional Free Air Thermal Current, 1-Pole (Ith) AC-3 Operation XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE580N 337 301 287 275 386 345 329 315 429 383 366 350 490 438 418 400 612 548 522 500 857 767 731 700 980 876 836 800 685 785 875 1000 1250 1750 2000 185 185 185 185 185 185 185 76 225 225 225 225 225 225 225 76 250 250 250 250 250 250 250 76 300 300 300 300 300 300 300 95 400 400 400 400 400 400 400 95 500 500 500 500 500 500 500 95 580 580 580 580 580 580 580 435 55 62 90 110 115 132 175 108 70 75 110 132 142 160 215 108 75 85 132 148 157 180 240 108 90 100 160 180 190 215 286 132 125 132 200 240 255 290 344 132 155 170 250 300 345 360 344 132 185 200 315 348 370 420 560 600 136 136 136 136 136 136 136 76 164 164 164 164 164 164 164 76 200 200 200 200 200 200 200 76 240 240 240 240 240 240 240 95 296 296 296 296 296 296 296 95 360 360 360 360 360 360 296 95 456 456 456 456 456 456 456 348 41 45 75 80 85 96 127 108 51 54 90 96 102 116 155 108 62 68 110 117 125 143 189 108 75 82 132 142 151 172 229 132 92 101 160 176 186 214 283 132 112 122 200 216 229 260 344 132 143 156 250 274 290 330 440 509 Rated Operational Current, 50/60 Hz1) (Ie) in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-4 Operation Rated Operational Current, 50/60 Hz1) (Ie) T echn ic al de ta ils in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-6A Operation Transformer Loads AC-6B Operation Capacitor Loads Individual compensation rated operational current Ie of three-phase capacitors in amperes Up to 525V 690V Maximum inrush current peak (x Ie) Component Lifesaving (Operations) Maximum Operating Frequency (ops/hr) 1) 2) 118 Values are application specific. Calculation is IeAC-3 = X / 6 *leTransformer where the X is the inrush 2) current of the transformer and leTransformer is the nominal current. 220 133 30 100,000 200 220 133 30 100,000 200 220 133 30 100,000 200 307 177 30 100,000 200 307 177 30 100,000 200 307 177 30 100,000 200 463 265 30 100,000 200 At maximum permissible ambient temperature. Example --The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. Technical details PG03407001U - June 2006 Standard Contactors, Frames B - R, AC1, 3, 4, 6A and 6B Electrical Indurance Ratings (Continued) Description AC-1 Operation Conventional Free Air Thermal Current, 3-Pole, 50 - 60 Hz at 40C (Ith) at 50C (Ith) at 55C (Ith) at 60C (Ith) Conventional Free Air Thermal Current, 1-Pole (Ith) XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC20R 1041 931 888 850 1102 986 940 900 1225 1095 1044 1000 1225 1095 1044 1000 1714 1533 1462 1400 2450 2190 2089 2000 2125 2250 2500 2500 3500 5000 650 650 650 650 650 650 650 435 750 750 750 750 750 750 750 580 820 820 820 820 820 820 820 580 1000 1000 1000 1000 1000 1000 1000 700 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 205 225 355 390 420 470 630 600 240 260 400 455 480 550 720 800 260 285 450 500 525 600 750 800 315 340 560 610 650 730 1000 1000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 512 512 512 512 512 512 512 348 576 576 576 576 576 576 576 464 656 656 656 656 656 656 656 464 800 800 800 800 800 800 800 700 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 161 176 280 307 326 370 494 509 181 200 315 346 367 417 556 678 209 228 355 394 418 474 633 678 260 280 450 490 520 590 780 1000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- AC-3 Operation Rated Operational Current, 50/60 Hz1)(Ie) in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-4 Operation in amperes 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V Rated power (P) in kilowatts 220/230V 240V 380/400V 415V 440V 500V 660/690V 1000V AC-6A Operation Transformer Loads AC-6B Operation Capacitor Loads Individual compensation rated operational current Ie of three-phase capacitors in amperes Up to 525V 690V Maximum inrush current peak (x Ie) Component Lifesaving (Operations) Maximum Operating Frequency (ops/hr) 1) 2) Values are application specific. Calculation is IeAC-3 = X / 6 *leTransformer where the X is the inrush 2) current of the transformer and leTransformer is the nominal current. 463 265 30 100,000 200 463 265 30 100,000 200 463 265 30 100,000 200 463 265 30 100,000 200 -- -- -- -- -- -- -- -- -- -- T echn ic al de ta ils Rated Operational Current, 50/60 Hz1) (Ie) At maximum permissible ambient temperature. Example -- The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of 18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended. PG03407001U - June 2006 Technical details 119 Standard Contactors, Frames B - R, DC1, Electrical Indurance Ratings Description XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C Rated operation current {1} (Ie) in amperes 60V 110V 220V 440V 20 20 15 1 20 20 15 1.3 20 20 15 1.3 20 20 15 1.3 35 35 35 2.9 40 40 40 2.9 40 40 40 2.9 60V 110V 220V 440V XTCE040D 50 50 45 2.9 XTCE050D 60 50 45 2.9 XTCE065D 72 72 65 2.9 XTCE080F 110 110 70 4.5 XTCE095F 110 110 70 4.5 XTCE115G 160 160 90 4.5 XTCE150G 160 160 90 4.5 60V 110V 220V 440V XTCE185L 300 300 300 11 XTCE225L 300 300 300 11 XTCE250L 300 300 300 11 XTCE300M 400 400 400 11 XTCE400M 400 400 400 11 XTCE500M 400 400 400 11 XTCE580N -- -- -- -- 60V 110V 220V 440V XTCE650N -- -- -- -- XTCE750N -- -- -- -- XTCE820N -- -- -- -- XTCEC10N -- -- -- -- XTCEC14P -- -- -- -- XTCEC20R -- -- -- -- -- -- -- -- -- T echn ic al de ta ils Standard Contactors, Frames B - R, DC3, Electrical Indurance Ratings 120 Description XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C Rated operation current {1} (Ie) in amperes 60V 110V 220V 440V 20 20 1.5 0.2 20 20 1.5 0.2 20 20 1.5 0.2 20 20 1.5 0.2 35 35 10 0.6 35 35 10 0.6 40 40 25 0.6 60V 110V 220V 440V XTCE040D 50 50 25 0.6 XTCE050D 60 50 25 0.6 XTCE065D 72 72 35 0.6 XTCE080F 110 110 35 1 XTCE095F 110 110 35 1 XTCE115G 160 160 40 1 XTCE150G 160 160 40 1 60V 110V 220V 440V XTCE185L 300 300 300 -- XTCE225L 300 300 300 -- XTCE250L 300 300 300 -- XTCE300M 400 400 400 -- XTCE400M 400 400 400 -- XTCE500M 400 400 400 -- XTCE580N -- -- -- -- 60V 110V 220V 440V XTCE650N -- -- -- -- XTCE750N -- -- -- -- XTCE820N -- -- -- -- XTCEC10N -- -- -- -- XTCEC14P -- -- -- -- XTCEC20R -- -- -- -- -- -- -- -- -- Technical details PG03407001U - June 2006 Standard Contactors, Frames B - R, DC5, Electrical Indurance Ratings Heat Loss Description XTCE007B XTCE009B XTCE012B XTCF020B XTCE015B XTCE018C XTCE025C XTCE032C Rated operation current {1} (Ie) in amperes 60V 110V 220V 440V 20 20 1.5 0.2 20 20 1.5 0.2 20 20 1.5 0.2 20 20 1.5 0.2 35 35 10 0.6 35 35 10 0.6 40 40 25 0.6 60V 110V 220V 440V XTCE040D 50 50 25 0.6 XTCE050D 60 50 25 0.6 XTCE065D 72 72 35 0.6 XTCE080F 110 110 35 1 XTCE095F 110 110 35 1 XTCE115G 160 160 40 1 XTCE150G 160 160 40 1 60V 110V 220V 440V XTCE185L 300 300 300 -- XTCE225L 300 300 300 -- XTCE250L 300 300 300 -- XTCE300M 400 400 400 -- XTCE400M 400 400 400 -- XTCE500M 400 400 400 -- XTCE580N -- -- -- -- 60V 110V 220V 440V XTCE650N -- -- -- -- XTCE750N -- -- -- -- XTCE820N -- -- -- -- XTCEC10N -- -- -- -- XTCEC14P -- -- -- -- XTCEC20R -- -- -- -- -- -- -- -- -- Description Current heat loss (3-Pole) in watts at Ith at Ie to AC-3/400V Impedance per pole, m Current heat loss (3-Pole) in watts at Ith at Ie to AC-3/400V Impedance per pole, m Current heat loss (3-Pole) in watts at Ith at Ie to AC-3/400V XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C 3 0.37 3 0.6 3 1.1 3 1.8 7.3 1.9 9.6 3.8 12.1 6.1 2.5 2.5 2.5 2.5 2 2 2 XTCE040D XTCE050D XTCE065D XTCE080F XTCE095F XTCE115G XTCE150G 11.3 7.2 19 11.3 28.8 19 14.6 11.5 21.8 16.2 30.4 23.8 46.1 40.5 1.5 1.5 1.5 0.6 0.6 0.6 0.6 XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M XTCE500M XTCE580N 79 36 108 55 95 48 123 69 188 120 236 120 227 120 XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC20R -- 257 150 288 200 355 239 355 355 697 -- 711 -- -- -- Impedance per pole, m Current heat loss (3-Pole) in watts at Ith at Ie to AC-3/400V Impedance per pole, m PG03407001U - June 2006 Technical details T echn ic al de ta ils Standard 3P Contactors, Frames B - R, Current Heat Loss, watts 121 Standard Contactors, Frames B - N, Mechanical Life Curves 7.5 5.5 4 3 65 50 40 32 25 XTCE065D XTCE050D XTCE040D XTCE032C XTCE025C 18 XTCE018C 12 Rated Output of Three-Phase Motors 50-60 Hz 22 18.5 15 11 Rated Operational Current e 50-60 Hz Rated Output of Three-Phase Motors 50-60 Hz 75 55 45 37 30 XTCE012B 9 7 XTCE009B XTCE007B A kW AC-3/400 V 6 4.5 4 2.2 2.2 1.5 Rated Operational Current e 50-60 Hz A kW AC-4/400 V 25 XTCE065D 21 XTCE050D 18 XTCE040D 15 XTCE032C 13 XTCE025C 10 XTCE018C 7 XTCE012B 6 XTCE009B 5 XTCE007B 4 3 2 0.02 0.4 0.6 1 0.04 0.06 0.1 0.2 2 4 Component Lifespan [Millions of Operations] 6 Normal Switching Duty - XTCE007B - XTCE065D 132 110 90 75 55 45 37 30 T echn ic al de ta ils 22 18.5 122 XTCEC10N XTCE820N XTCE750N XTCE650N XTCE580N XTCE500M XTCE400M XTCE300M AC-3/400 V 250 XTCE250M 225 XTCE225L 185 XTCE185L 104 85 72 58 43 36 30 11 7.5 23 16 0.01 0.4 0.6 1 0.2 2 4 0.02 0.04 0.06 0.1 Component Lifespan [Millions of Operations] Normal Switching Duty - XTCE185l - XTCEC10N Eaton list Prefix XTAE012B XTAE015B XTAE018C Technical details kW A 355 315 280 250 200 160 656 576 512 456 360 296 XTCE820N XTCE750N XTCE650N XTCE580N XTCE500M XTCE400M 240 200 164 140 104 85 72 58 43 36 30 XTCE300M XTCE250M XTCE225L XTCE185L 132 110 90 75 55 45 37 30 22 18.5 15 145 15 6 10 Extreme Switching Duty - XTCE007B - XTCE065D Rated Output of Three-Phase Motors 50-60 Hz 250 200 160 A 1000 820 750 650 580 500 400 300 Rated Operational Current e 50-60 Hz Rated Output of Three-Phase Motors 50-60 Hz kW 560 450 400 355 315 0.4 0.6 1 0.04 0.06 0.1 0.2 2 4 Component Lifespan [Millions of Operations] 0.02 0.01 10 6 10 Rated Operational Current e 50-60 Hz 0.01 11 23 7.5 16 5.5 4 3 8.8 6.5 2.2 1.5 AC-4/400 V 12 5 3.5 0.01 0.02 0.4 0.6 1 0.04 0.06 0.1 0.2 2 4 Component Lifespan [Millions of Operations] Extreme Switching Duty - XTCE185L - XTCE820N AC-3 12A 15A 18A Electrical Life (Operations) 1 million 1.2 million 2 million PG03407001U - June 2006 6 10 Standard Contactors, Frames B - N, Mechanical Life Curves (Continued) 1400 XTCEC14P AC-1/400 V XTCE820N/XTCEC10N 900 1000 XTCE650N XTCE750N 850 XTCE580N 800 700 XTCE500M 500 XTCE400M XTCE300M 400 350 XTCE250M 300 XTCE225L 275 XTCE185L Breaking Current A 160 100 55 35 20 10 7 5 4 3 2 1 0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10 Component Lifespan [Millions of Operations] Switching Duty for Non-motor loads, 3-pole, 4-pole XTCE185l - XTCEC14P A 10000 XTCE820N XTCEC10N, XTCEC14P, XTCEC20R XTCE750N 8000 XTCE650N XTCE580N 6000 AC-1/400 V XTCE500M 5000 XTCE400M 4000 Short-Time Current XTCE300M 3000 XTCE250M 2500 2000 XTCE185L/XTCE225L 1500 1000 700 500 400 300 Seconds 2 3 5 7 10 20 30 Duration of Load 50 70 100 1 min T echn ic al de ta ils 200 200 300 500 700 900 3 5 10 15 min min min min Short-Time Loading, 3 Pole - XTCE185L - XTCEC20R PG03407001U - June 2006 Technical details 123 Coil Data Standard, Contactors, Frames B - D, Coil Data XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C XTCE040D XTCE050D XTCE065D T echn ic al de ta ils Frame Voltage Tolerance Pick-Up (x Uc) AC operated DC operated 124 0.8 - 1.1 0.8 - 1.19 0.8 - 1.1 0.8 - 1.19 0.8 - 1.1 0.8 - 1.19 0.8 - 1.1 0.8 - 1.19 0.8 - 1.1 0.7 - 1.2 0.8 - 1.1 0.7 - 1.2 0.8 - 1.1 0.7 - 1.2 0.8 - 1.1 0.7 - 1.2 0.8 - 1.1 0.7 - 1.2 0.8 - 1.1 0.7 - 1.2 1) 1) 1) 2) 2) 2) 2) 2) 2) 2) 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 24 19 50 40 52 40 52 40 149 80 149 80 149 80 3.4 1.2 7.1 2.1 7.1 2.1 7.1 2.1 16 4.3 16 4.3 16 4.3 30 23 4.4 1.4 67 50 8.7 2.6 67 50 8.7 2.6 67 50 8.7 2.6 178 117 19 5.3 178 117 19 5.3 178 117 19 5.3 27 25 22 21 4.2 3.3 1.4 1.2 62 58 48 43 9.1 6.5 2.3 2 62 58 48 43 9.1 6.5 2.3 2 62 58 48 43 9.1 6.5 2.3 2 168 154 120 43 22 14 5.3 4.3 168 154 120 43 22 14 5.3 4.3 168 154 120 43 22 14 5.3 4.3 4.5 4.5 100 12 at 24V 0.5 at 24V 100 12 at 24V 0.5 at 24V 100 12 at 24V 0.5 at 24V 100 12 at 24V 0.5 at 24V 100 12 at 24V 0.5 at 24V 100 12 at 24V 0.5 at 24V 100 <21 <18 <22 <14 <22 <14 <22 <14 <18 <13 <18 <13 <18 <13 <31 <12 10 <47 <30 10 <47 <30 10 <47 <30 10 <54 <24 10 <54 <24 10 <54 <24 10 Drop-Out (x Uc) 0.3 - 0.6 0.3 - 0.6 0.3 - 0.6 AC operated 0.15 - 0.6 0.15 - 0.6 0.15 - 0.6 DC operated Power Consumption of the coil at cold state and 1.0 x Uc AC operated Pick-Up VA 24 24 24 Pick-Up W 19 19 19 Single-voltage coil 50 Hz Sealing VA 3.4 3.4 3.4 Sealing W 1.2 1.2 1.2 60 Hz Pick-Up VA 30 30 30 Pick-Up W 23 23 23 Sealing VA 4.4 4.4 4.4 Sealing W 1.4 1.4 1.4 50/60 Hz Pick-Up VA 27 27 27 25 25 25 Pick-Up W 22 22 22 21 21 21 Sealing VA 4.2 4.2 4.2 3.3 3.3 3.3 Sealing W 1.4 1.4 1.4 1.2 1.2 1.2 DC operated Pick-Up W 3 3 4.5 Sealing W 3 3 4.5 Duty Factor (%DF) 100 100 100 Switching Time at 100% Uc (approximate values) Main Contact AC operated Closing delay (mS) <21 <21 <21 Opening delay (mS) <18 <18 <18 DC operated Closing delay (mS) <31 <31 <31 Opening delay (mS) <12 <12 <12 Arcing time (mS) 10 10 10 Electromagnetic Compatibility (EMC) Emitted interference To EN-60947-1 Noise Immunity To EN-60947-1 1) 2) At 24V: 0.7 - 1.3 without additional auxiliary contact modules and ambient temperature +40C [104F]. Coil Suffix AD: Umin 110V DC/Umax 130V DC. Coil Suffix BD: Umin 200V DC/Umax240V DC. Example: UC = 0.7 x Umin - 1.2 x Umax UC = 0.7 x 24V - 1.2 x 27V DC Technical details PG03407001U - June 2006 Standard, Contactors, Frames F - G, Coil Data Voltage Tolerance Pick-Up (x Uc) AC operated DC operated Drop-Out (x Uc) AC operated DC operated XTCE80F XTCE95F XTCE115G XTCE150G 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1 0.8 - 1.1 0.7 - 1.2 1) 0.7 - 1.2 1) 0.7 - 1.2 1) 0.7 - 1.2 1) 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 0.3 - 0.6 0.15 - 0.6 310 165 180 130 180 130 26 5.8 3.1 2.1 3.1 2.1 345 190 30 7.1 170 130 3.1 2.1 170 130 3.1 2.1 372/328 190 37.1/22.6 7.5/6.1 170/170 130 3.1/3.1 2.1/2.1 170/170 130 3.1/3.1 2.1/2.1 90 at 24V 1.3 at 24V 100 149 at 24V 2.1 at 24V 100 149 at 24V 2.1 at 24V 100 Max. <20 mS Max. <14 mS Max. <33 mS Max. <41 mS Max. <33 mS Max. <41 mS Max. <45 mS Max. <34 mS Max. <35 mS Max. <30 mS Max. <35 mS Max. <30 mS 15 <1 15 <1 15 <1 0.3 - 0.6 0.15 - 0.6 Power Consumption of the coil at cold state and 1.0 x Uc AC operated Pick-Up VA 310 Pick-Up W 165 Single-voltage coil 50 Hz Sealing VA 26 Sealing W 5.8 60 Hz Pick-Up VA 345 Pick-Up W 190 Sealing VA 30 Sealing W 7.1 50/60 Hz Pick-Up VA 372/328 Pick-Up W 190 Sealing VA 37.1/22.6 Sealing W 7.5/6.1 DC operated Pick-Up W 90 at 24V Sealing W 1.3 at 24V Duty Factor (%DF) 100 Switching Time at 100% Uc (approximate values) Main Contact AC operated Closing delay (mS) Max. <20 mS Opening delay (mS) Max. <14 mS DC operated Closing delay (mS) Max. <45 mS Opening delay (mS) Max. <34 mS Electromagnetic Compatibility (EMC) Emitted interference To EN60947-1 Noise Immunity To EN60947-1 Arcing Time (mS) 15 Permissible residual current with actuation of A1 <1 A2 by the electronics (with 0 signal mA) At 24V: 0.7 - 1.3 without additional auxiliary contact modules and ambient temperature +40C. T echn ic al de ta ils 1) PG03407001U - June 2006 Technical details 125 Standard, Contactors, Frames L - R, Coil Data Description XTCE185L XTCE225L, XTCE250L XTCE300M, XTCE400M XTCE500M Voltage Tolerance Pick-Up (x Uc) XTCE185L - XTCEC20R XTCS185L - XTCS500M Drop-Out (x Uc) 0.7 x Ucmin -- 1.15 x Ucmax XTCE185L - XTCEC20R XTCS185L - XTCS500M Power Consumption of the coil at cold state and 1.0 x Uc XTCE185L - XTCEC20R Pick-Up VA 250 1) Pick-Up W 200 Sealing VA 4.3 Sealing W 3.3 0.2 x Ucmin -- 0.6 x Ucmax 0.2 x Ucmin -- 0.4 x Ucmax 0.85 x Ucmin -- 1.1 x Ucmax XTCS185L - XTCS500M Pick-Up VA 360 Pick-Up W 325 Sealing VA 4.3 Sealing W 3.3 Duty Factor (%DF) 100 Switching Time at 100% Main Contact Uc (approximate values) 250 1) 200 4.3 3.3 450 1) 350 4.3 3.3 450 1) 350 4.3 3.3 360 325 4.3 3.3 100 715 645 4.3 3.3 100 715 645 4.3 3.3 100 XTCE185L - XTCEC20R Closing delay (mS) <100 <100 <80 Opening delay (mS) <80 <80 <80 XTCS185L - XTCS500M Closing delay (mS) <50 <50 <50 Opening delay (mS) <40 <40 <40 Reaction in Threshold and Sealing State Transition Range (XTCE185L - XTCEC20R) Voltage interruptions Time is bridged successfully (0 - 0.2 x Ucmin) < 10ms Drop-out of the contactor (0 - 0.2 x Ucmin) > 10ms Voltage Dips (0.2 - 0.6 x Ucmin) < 12ms (0.6 - 0.7 x Ucmin) Excess Voltage (1.15 - 1.3 x Ucmax) Contactor remains switched on Contactor remains switched on Drop-out of the contactor (>1.3 x Ucmax) < 3s (>1.3 x Ucmax) > 3s Pick - Up phase (0 - 0.7 x Ucmin) Contactor does not switch on Contactor switches on with certainty Contactor switches on with certainty (0.7 x Ucmin -1.15 x Ucmax) T echn ic al de ta ils (>1.15 x Ucmax) 126 1) <50 <40 Time is bridged successfully Drop-out of the contactor Contactor remains switched on (0.2 - 0.6 x Ucmin) > 12ms Permissible contact resistance (of the external command device with actuation of A11), Permissible residual current (with actuation of A11 by the electronics with 0 signal) SPS Signal Level (A3 - A4) to IEC/EN 61131-2 (Type 2) High Low Electromagnetic compatibility (EMC) <80 <80 < 500 < 500 < 500 < 500 <1 <1 <1 <1 15V 15V 15V 15V 5V 5V 5V 5V This product is designed for operation in industrial environments. Usage in domestic areas can cause radio frequency interference (RFI). Noise suppression measures must be provided for the additional interference. Control transformer with Uk <6%. Technical details PG03407001U - June 2006 Standard, Contactors, Frames L - R, Coil Data (Continued) Description XTCE580N XTCE750N, XTCE820N XTCEC10N XTCEC14P XTCEC20R Voltage Tolerance Pick-Up (x Uc) 0.7 x Ucmin -- 1.15 x Ucmax XTCE185L - XTCEC20R XTCS185L - XTCS500M Drop-Out (x Uc) 0.85 x Ucmin -- 1.1 x Ucmax XTCE185L - XTCEC20R XTCS185L - XTCS500M Power Consumption of the coil at cold state and 1.0 x Uc XTCE185L - XTCEC20R Pick-Up VA 800 1) Pick-Up W 700 Sealing VA 7.5 Sealing W 6.5 XTCS185L -- XTCS500M Pick-Up VA -- Pick-Up W -- Sealing VA -- Sealing W -- Duty Factor (%DF) 100 Switching Time at 100% Main Contact Uc (approximate values) 0.2 x Ucmin -- 0.6 x Ucmax 0.2 x Ucmin -- 0.4 x Ucmax 800 1) 700 7.5 6.5 800 1) 700 7.5 6.5 800 1) 700 7.5 6.5 1600 1) 1400 15 13 -- -- -- -- 100 -- -- -- -- 100 -- -- -- -- 100 -- -- -- -- 100 <70 <70 <70 <40 <70 <40 -- -- -- -- -- -- XTCE185L - XTCEC20R Closing delay (mS) <70 <70 Opening delay (mS) <70 <70 XTCS185L - XTCS500M Closing delay (mS) -- -- Opening delay (mS) -- -- Reaction in Threshold and Sealing State Transition Range (XTCE185L - XTCEC20R) Voltage interruptions Time is bridged successfully (0 - 0.2 x Ucmin) < 10ms Drop-out of the contactor (0 - 0.2 x Ucmin) > 10ms (0.2 - 0.6 x Ucmin) > 12ms (0.6 - 0.7 x Ucmin) Excess Voltage (1.15 - 1.3 x Ucmax) (>1.3 x Ucmax) < 3s (>1.3 x Ucmax) > 3s Pick - Up phase (0 - 0.7 x Ucmin) (0.7 x Ucmin -1.15 x Ucmax) (>1.15 x Ucmax) Permissible contact resistance (of the external command device with actuation of A11), Permissible residual current (with actuation of A11 by the electronics with 0 signal) SPS Signal Level (A3 - A4) to IEC/EN 61131-2 (Type 2) High Low Electromagnetic compatibility (EMC) 1) Time is bridged successfully Drop-out of the contactor Contactor remains switched on Contactor remains switched on Contactor remains switched on Drop-out of the contactor Contactor does not switch on Contactor switches on with certainty Contactor switches on with certainty < 500 < 500 < 500 < 500 <1 <1 <1 <1 500 <1 15V 15V 15V 15V 15V 5V 5V 5V 5V 5V This product is designed for operation in industrial environments. Usage in domestic areas can cause radio frequency interference (RFI). Noise suppression measures must be provided for the additional interference. Control transformer with Uk <7%. PG03407001U - June 2006 Technical details T echn ic al de ta ils Voltage Dips (0.2 - 0.6 x Ucmin) < 12ms 127 Standard, Contactors, Frames B - N, Auxiliary Contacts, Technical Data and Specifications Description XTCE007B...- XTCE032C XTCEXFAC... XTCEXFATC XTCEXFCC... XTCEXSCL XTCEXFAG... XTCEXSBLN... XTCEXSBN... XTCEXSBNC... XTCEXSCN... XTCEXSCNC... Yes Interlocked opposing contacts with an auxiliary contact module (to IEC 60947-5 -1 Annex L) Break contact (not late-break contact) suitable as a mirror contact (to IEC/EN 60947-4 -1 Annex F) -- Yes Yes Yes XTCE007B... - XTCE032C XTCE007B... - XTCE032C XTCE007B... - XTCE032C XTCE040D... - XTCE065D... XTCE040D... - XTCE065D... XTCE185L... - XTCEC10N... Rated impulse withstand voltage, (Uimp) VAC Overvoltage category / pollution degree Rated insulation voltage, (Ui) VAC Rated operational voltage, (Ue) VAC Safe isolation to VDE 0106 Part 101 and Part 101(A) in VAC Between coil and auxiliary contacts Between the auxiliary contacts Rated Operational Current, le AC-15 230V 380/415V 500V 6000 6000 6000 6000 6000 III/3 690 500 III/3 690 500 III/3 690 500 III/3 690 500 III/3 690 500 400 400 400 400 400 400 440 440 440 440 6A 4A 1.5A 6A 3A -- 6A 4A 1.5A 6A 4A 1.5A 6A 4A 1.5A DC-3 L/R <5 mS 1) 24V 60V 110V 220V Conventional thermal current, Ith 10A 6A 3A 1A 10A 6A 3A 1A 10A 6A 3A 1A 10A 6A 3A 1A 10A 6A 3A 1A 16A 16A 16A3) 10A 10A Control circuit reliability <10-8, < one failure at 100 million operations (at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) Component Lifespan, Operations x 106 at Ue = 230V, AC-15, 3A Short-circuit rating without welding Maximum fuse, gG/gL 1) 2) 3) 1.3 1.3 1.3 1.3 1.3 10A 10A 10A 16A 16A 2) Making and breaking conditions to DC-13, time L/R contact as stated. See fuses overlay for time/current characteristic (on request). Conventional thermal current(Ith) of XTCEXSCL - 10A XTCEXPLKB XTCEXPLKC XTCEXPLKD XTCEXPLKG mm2 1 - 16 16 16 -- Flexible with ferrule mm2 1 x (16 - 35) 1 x (16 - 120) -- Stranded mm2 1 x (16 - 50) 1 x (16 - 120) mm2 1 x (0.5 - 25) 2 x (0.5 0 16) 1 x (0.5 - 25) 2 x (0.5 0 16) 6 x 9 x 0.8 -- -- 1 x (35 - 300) 2 x (35 - 120) 2 x (11 x 21 x 1) Nm 4 4 14 -- SW Size mm 2 -- 2 -- -- 5 -- 6 Ith A 50 100 180 400 Ith A 60 -- -- -- T echn ic al de ta ils Parallel link Terminal capacities Solid Flat conductor Tightening torgue Tool Pozidriv screwdriver Hexagon socket-head spanner Conventional thermal current 3 pole 4 pole 128 Technical details number of segments x width x thickness PG03407001U - June 2006 Auxiliary Contacts Possible Combinations Eaton list number Built-in Aux Front (Top) Mount 2-Pole 4-Pole Side Mount 2-Pole Total Auxillary Contacts Available XTMC8A... XTMC9A... XTCE007B... XTCE015B... XTCE018C... XTCE032C... 1NO or 1NC 1 1 1 1 1 - 1 2 1 2 2 4 2 3 5 3 5 3 5 3 6 6 6 8 8 8 1NO or 1NC 1NO or 1NC XTCE040D00... XTCE045D00... XTCE060F00... XTCE150G00... 2NO or 2NC T echn ic al de ta ils XTCE185L22... XTCEC20R22... 1 1 1 1 1 - PG03407001U - June 2006 Technical details 129 Auxiliary Contacts Combinations XTMC6A... - XTMC9A... XTCE007B... - XTCE032C... XTMCXF... A... XTCEXF... C... 2 - Pole 0r 4 - Pole Auxiliary Contact Combinations - Frame A - B XTCEXF...C... 2 - Pole 0r 4 - Pole XTCEXSCC11 XTCE007B... - XTCE032C... -OR- + XTCE018C... - XTCE032C... Auxiliary Contact Combinations - Frame C -OR- + + XTCEXF...G... 4 - Pole + XTCEXSBN11 + XTCEXSBN11 XTCEXF...G... 2 - Pole XTCEXSBN11 + XTCE040D... - XTCE065D... XTCEXSBN11 XTCEXSBN11 XTCE040D... - XTCE065D... Auxiliary Contact Combinations - Frame D XTCE080F... - XTCE150G... + + + XTCEXSCN11 XTCE185L... - XTCEC20R... + XTCEXSBN11 XTCEXSBN11 (Built-in) + Auxiliary Contact Combinations - Frame L- R 130 Technical details PG03407001U - June 2006 + XTCEXSCN11 + XTCEXSBN11 -OR- XTCEXSCN11 + XTCEXSBN11 + XTCEXF...G... 2 - Pole or 4 - Pole Auxiliary Contact Combinations - Frame F - G XTCEXSCN11 T echn ic al de ta ils XTCEXSBN11 XTCE080F... - XTCE150G... Standard, 3P Contactors Frames B - R, Contact Sequence (Circuit Symbols) Contactor Frame B-C Auxiliary Contacts 1NO B-C 1NC D-G -- Contact Sequence A1 1 3 5 13 A2 2 4 6 14 A1 1 3 5 21 A2 2 4 6 22 A1 1 3 5 A2 2 4 6 L-R 2NO-2NC A1 1 3 5 13 21 31 43 A2 2 4 6 14 22 32 44 Note: The 7 - 32A XTCE Contactors have positively driven contacts between the integrated auxiliary contact and the auxiliary contact module as well as within the auxiliary contact modules. The 40 - 65A XTCE Contactors have positively driven contacts within the auxiliary contact module. 6 auxiliary contacts are possible with a combination of side mounted and front mount auxiliary contacts. IEC Utilization AC-1: AC-3: AC-4: Categories, see page 76, Reference Data. Non-inductive or slightly inductive loads. Squirrel-cage motors -- starting, switching of motors during running. Squirrel-cage motors -- starting, plugging, inching. Standard Contactors, Wiring Diagrams 21 22 0 21 22 22 21 21 22 13 14 I 14 13 54 54 K1M K2M 53 53 22 22 K2M 21 K1M 21 A1 A1 K1M K2M 22 21 22 21 14 13 I 14 13 14 14 K2M K1M 13 13 22 K2M K1M 22 21 21 A1 A1 K1M K2M A2 A2 (-)N 7 - 32A 40 - 150A A2 A2 1 3 5 II II K1M M1 L1 L2 L3 B1 x In B 1 x In 0.58 x In 13 5 24 6 K5M 1 3 5 2 4 6 K3M A 0.58 x In U1 V1 M1 W1 3 M1 U V W M 3 7 - 65A with Mechanical Interlock L1 L2 L3 K1M 13 5 2 4 6 K2M 2 4 6 C V2 W2 U2 Wiring Diagram; 12A - 385A AC - 3 PG03407001U - June 2006 135 24 6 K1M 0.58 x In 13 5 2 4 6 K5M 13 5 2 4 6 K3M A0.58xIn U1 V1 M1 W1 3 M1 13 5 2 4 6 C V2 W2 U2 T echn ic al de ta ils 0 Wiring Diagram; 430A -1700A AC - 3 Technical details 131 Standard, Overload Relays, Settings and Tripping Characteristics Setting A: IN x 0.58 Motor Protection in the Star and Delta Configurations B: IN x 1 Only partial motor protection in star position C: IN x 0.58 Motor not protected in star position Timing Relay set to approximately 10 sec Starting < 15 sec 15 - 40 sec > 40 sec Overload Relays These tripping characteristics are the mean values of the spread at 20C ambient temperature in a cold state. Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to approximately 25% of the read off value. Specific characteristics for each individual setting range can be found in MN03402001E. Minutes 2h 100 60 40 XTOB...BC1, XTOB...CC1, XTOB...DC1 20 10 6 4 2 1 40 3-Phase Seconds 20 10 6 4 2-Phase 2 1 0.6 1 1.5 2 3 4 6 8 10 15 20 x Setting Current T echn ic al de ta ils Tripping Characteristics 132 Technical details PG03407001U - June 2006 Standard, Overload Relays, Technical Data and Standards Description General Standards Climatic Proofing Ambient Temperature 1) Temperature Compensation Mechanical Shock Resistance (IEC/EN 60068-2-27) Half-sinusoidal Shock 10 mS Degree of Protection Protection against Direct Contact when Actuated from Front (IEC 536) Insulation Voltage (Ui) VAC Overvoltage Category /Pollution Degree Impulse Withstand Voltage (Uimp) VAC Operational Voltage (Ue) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between auxiliary contacts and main contacts (VAC) Between main contacts (VAC) Overload Relay Setting Range Temperature Compensation Residual Error >20C (%/K) Current Heat Loss (3 Conductors) Lower value of setting range, W Upper value of setting range, W Terminal Capacity Solid, mm2 Flexible with ferrule, mm2 Solid or Stranded, AWG Terminal Screw Tightening Torque Nm Lb-in Tools Pozidrive screwdriver Standard screwdriver 2) 3) XTOB...DC1 IEC/EN 60947, VDE 0660, UL, CSA Damp heat, constant, to IEC 60068-278; Damp heat, cyclic, to IEC 60 068-230 -25 to 50C IEC/EN 60947, VDE 0660, UL, CSA Damp heat, constant, to IEC 60068-278; Damp heat, cyclic, to IEC 60 068-230 -25 to 50C Continuous Continuous 10g IP20 Finger and back of hand proof 10g IP20 Finger and back of hand proof 690 III/3 6000 690 690 III/3 6000 690 440 440 0.1 - 32A < 0.25 440 440 6 - 75A < 0.25 2.5 6 2 x (1 - 6) 2 x (1 - 4) 3 7.5 2 x (1 - 16) 1 x 25 2 x (1 - 6) 2) 2 x (1 - 10) 3) 14-8 M4 14-2 M6 1.8 16 3.5 31 Size 2 1x6 Size 2 1x6 Ambient temperature operating range to IEC/EN 60947, PTB: -5C to +50C. 6 mm2 flexible with ferrules to DIN 46228. Main contact terminal capacity, solid and stranded conductors with ferrules: When using 2 conductors use identical cross-section. T echn ic al de ta ils 1) XTOB...BC1, XTOB...CC1 PG03407001U - June 2006 Technical details 133 Standard, Overload Relays, Technical Data and Standards Description Auxiliary and Control Circuit Connections Impulse Withstand Voltage (Uimp) VAC Overvoltage Category/Pollution Degree Terminal Capacity Solid, mm2 Flexible with ferrule, mm2 Solid or stranded, AWG Terminal Screw Tightening Torque Nm Tools Pozidrive screwdriver Standard screwdriver Auxiliary Circuit Rated Insulation Voltage (Ui) VAC Rated Operational Voltage (Ue) VAC Safe Isolation to VDE 0106 Part 101 and Part 101/A1 Between the auxiliary contacts (VAC) Conventional Thermal Current, Ith Rated Operational Current -- AC-15 NO Contact 120V 240V 415V 500V NC Contact 120V 240V 415V 500V Rated Operational Current -- DC-13 L/R <15 mS 1) 24V 60V 110V 220V Short Circuit Rating without Welding Maximum fuse, A gG/gL XTOB...DC1 6000 III/3 6000 III/3 2 x (0.75 - 4) 2 x (0.75 - 2.5) 2 x (18 - 12) 2 x (0.75 - 4) 2 x (0.75 - 2.5) 2 x (18 - 12) M3.5 M3.5 0.8 - 1.3 0.8 - 1.3 Size 2 1x6 500 500 Size 2 1x6 500 500 240 6 240 6 1.5 1.5 0.5 0.5 1.5 1.5 0.5 0.5 1.5 1.5 0.9 0.8 1.5 1.5 0.9 0.8 0.9 0.75 0.4 0.2 0.9 0.75 0.4 0.2 6 6 Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated. T echn ic al de ta ils 1) XTOB...BC1, XTOB...CC1 134 Technical details PG03407001U - June 2006 Standard, Overload Relays, Type 2 Co-ordination with XT Contactors and BS88 Fuses Motor 415V leA 440V leA lq kA 0.09 0.12 0.18 0.25 0.37 0.55 .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 0.31 0.41 0.6 0.8 1.1 1.5 1.9 2.6 3.6 5 6.6 8.5 11.3 15.2 21.7 29.3 36 41 55 0.3 0.4 0.58 0.8 1.1 1.5 1.8 2.6 3.5 4.8 6.4 8.2 10.9 14.6 20.9 28 35 40 53 0.21 0.31 0.46 0.64 1 1.4 1.8 2.4 3.3 4.7 6.1 7.9 10.3 14 19.8 26.4 33 37 50 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 Combinations Contactor BS88 Fuse Overload Relay A XTCE007... XTCE007... XTCE007... XTCE007... XTCE007... XTCE007... XTCE007... XTCE007... XTCE007... XTCE007... XTCE007... XTCE009... XTCE015... XTCE018... XTCE025.. XTCE032... XTCE050... XTCE065... XTCE065... XTOBP40BC1 XTOBP60BC1 XTOBP60BC1 XTOB001BC1 XTOB016BC1 XTOB016BC1 XTOB2P4BC1 XTOB2P4BC1 XTOB2P4BC1 XTOB006BC1 XTOB010BC1 XTOB010BC1 XTOB016CC1 XTOB016CC1 XTOB024CC1 XTOB032CC1 XTOB040DC1 XTOB057DC1 XTOB065DC1 2 4 4 4 6 6 10 16 16 20 20 20 25 25 35 & 32M35 50 63 80 100 T echn ic al de ta ils PkW 400V leA PG03407001U - June 2006 Technical details 135 8 Technical details Manual Motor Protectors For motors with service factors less than 1.15, multiply the motor FLA by .90 to select appropriate MMP. Example: For motor having FLA of 6.4A and service factor of 1.0 (6.4A x .90 = 5.76A) select Eaton list number XTPB6P3B01. For motor with service factor of 1.15 or greater, use motor nameplate Full Load Amperes to select the appropriate MMP. Example: For motor having FLA of 11A and service factor of 1.15, select Eaton list number XTPR012BC1. The assembled Manual Motor Controller (MMC) consists of a XTPR Manual Motor Protector (MMP) and a XTCE contactor. Up to 12A, the assembly can be mounted directly on DIN rail without an adapter. The contactors are supported mechanically with a mechanical connection element (included in XTPAXTPCB). For 16A and above, the assembly is mounted via a DIN Rail Adapter Plate (XTPAXTPCCP) and the electrical connection is made with electrical contact modules (XTPAXEMMC), both included in XTPAXTPCC. Service Factor Settings: For motors with a service factor (SF) of 1.15, use motor nameplate Full Load Amperes (FLA) to select the appropriate motor controller --> I r = 1 x I n mot. For motors with a service factor (SF) of 1.0 or less, multiply the motor FLA by 0.9 to select the appropriate motor controller --> I r = 0.9 x I n mot. Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. M 3~ XTSC... Manual Motor Controller Manual Motor Protectors, Frame B, Pushbutton, dimensional drawing 45 45 5.5 T echn ic al de ta ils 93 44 74 85 Manual Motor Protectors -- XTPB PG03407001U - June 2006 Technical details 136 Manual Motor Protectors, and Manual Transformer Protectors, Frame B, Rotary, dimensional drawings 45 93 50 45 88 94 Manual Motor Protectors, Manual Transformer Protectors -- XTPR...B, XTPT and XTPM Manual Motor Protectors, Frame B, Rotary with Current Limiter, dimensional drawing 45 28 * 90 93 73 7.5 * IEC/EN 60715 DIN Rail 44 7.5 49.5 70 Current Limiter -- XTPAXCL Manual Motor Protectors, Frame B, Rotary with Early-Make Auxilliary Contacts, dimensional drawing 80 XTPAXFAEM20 45 45 50 55 T echn ic al de ta ils 93 XTPAXFAEM20 68 86 MMPs with Early-Make Auxiliary Contacts -- XTPR...BC1 + XTPAXFAEM20 PG03407001U - June 2006 Technical details 137 Manual Motor Protectors, Frame D, dimensional drawing 4 65 130 45 125 140 30 7.5 118 55 127 145 171 Manual Motor Protectors, Frame B and D, Standard Auxilliary Contacts, dimensional drawing 45 36 9 90 26 68 Standard Auxiliary Contact -- XTPAXSA... Manual Motor Protectors, Frame B and D, Trip Indicating Auxilliary Contact, dimensional drawing 36 45 90 26 9 T echn ic al de ta ils 68 Trip Indicating Auxiliary Contact -- XTPAXSATR... Manual Motor Protectors, Frame B and D, Undervoltage / Shunt Release, dimensional drawing 45 36 18 90 49 68 Undervoltage / Shunt Release -- XTPAXUVR..., XTPAXSR... 138 Technical details PG03407001U - June 2006 Manual Motor Protectors, Frame B and D, 3P Commoning Links, dimensional drawing 234 (108 ) 180 (90) 27 27 63 45 Three-Phase Commoning Link, XTPAXCLKA4, XTPAXCLKA2 Three-Phase Commoning Link, XTPAXCLKC4, XTPAXCLKC2 261 (207,153, 99) 27 54 Overlapping Mounting to Extend the Three-Phase Commoning Link Three-Phase Commoning Link, XTPAXCLKB5, XTPAXCLKB4, XTPAXCLKB3, and XTPAXCLKB2 36 36 14 205 170 33 Three-Phase Commoning Link -- XTPAXCLKA4D 33 14 Three-Phase Commoning Link -- XTPAXCLKB3D 36 36 14 151 117 33 Three-Phase Commoning Link -- XTPAXCLKA3D 14 33 Three-Phase Commoning Link -- XTPAXCLKB2D 36 98 14 33 260 Three-Phase Commoning Link -- XTPAXCLKA2D 14 33 Three-Phase Commoning Link -- XTPAXCLKC4D 36 36 232 Three-Phase Commoning Link -- XTPAXCLKB4D PG03407001U - June 2006 14 33 115 14 T echn ic al de ta ils 36 33 Three-Phase Commoning Link -- XTPAXCLKC2D Technical details 139 Manual Motor Protectors, Frame B and D, Incoming Terminal, Line Side Adapter, dimensional drawing 56 31 7.5 XTPAXLSA 73 48 41 XTPAXIT T echn ic al de ta ils Incoming Terminal, Line Side Adapter -- XTPAXIT, XTPAXLSA 140 Technical details PG03407001U - June 2006 Manual Motor Protectors, Insulated Enclosures, Surface mount, dimensional drawing 158 70 80 90 100 Insulated Enclosures for Surface Mounting -- XTPAXENCS40 98 30 Drilling Dimensions 30 44 158 97.5 4.5 28 33 80 97.5 125.5 55 158 153 80 4.5 8 Insulated Enclosures for Surface Mounting -- XTPAXENCS55..., XTPAXENCSEM... 158 80 116.5 Insulated Enclosures for Surface Mounting, XTPBXENAS... and XTPBXENCS... 80 T echn ic al de ta ils 158 116.5 177.2 Insulated Enclosures for Surface Mounting, XTPBXENASEK65 and XTPBXENASES65 158 80 116.5 129.5 Insulated Enclosures for Surface Mounting, XTPBXENASLEGS and XTPBXENASLOGS PG03407001U - June 2006 Technical details 141 Manual Motor Protectors, Insulated Enclosures, Surface mount, dimensional drawing (Continued) 181 160 240 47.5 100 104 160 134 181 Insulated Enclosures for Surface Mounting XTPAXENAS4 and XTPAXENCS41 181 197 Insulated Enclosures for Surface Mounting -- XTPAXENCSD65... 160 100 47.5 103 130 T echn ic al de ta ils Insulated Enclosures for Surface Mounting XTPAXENAS55..., XTPAXENASEM55..., XTPAXENC65..., XTPAXENCSEM65... 142 Technical details PG03407001U - June 2006 Manual Motor Protectors, Insulated Enclosures, Surface mount, dimensional drawing (Continued) 3 98 32 72 5.6 Dia. 72 240 193 160 186 28 142 30 T echn ic al de ta ils Insulated Enclosures for Surface Mounting -- XTPAXENCSD65... + XTPAXPAPL2, XTPAXENCSD65 PG03407001U - June 2006 Technical details 143 Manual Motor Protectors, Insulated Enclosures, Flush mount, dimensional drawing 69 129 90.2 93 115.2 Insulated Enclosures for Flush Mounting, XTPBXENCF... 69 129 90.2 93 115.2 175.9 Insulated Enclosures for Flush Mounting, XTPBXENCFEK55 and XTPBXENCFES55 69 129 90.2 93 115.2 T echn ic al de ta ils Insulated Enclosures for Flush Mounting, XTPBXENCFLE55 and XTPBXENCFLO55 144 Technical details PG03407001U - June 2006 Manual Motor Protectors, Insulated Enclosures, Flush mount, dimensional drawing (Continued) 69 55 129 85 80 96 124 98 30 30 28 58 21 129 55 85 80 96 124 T echn ic al de ta ils Insulated Enclosures for Flush Mounting, XTPAXENCF..., XTPAXENCF55... + XTPAXPL3 PG03407001U - June 2006 Technical details 145 Manual Motor Protectors, Insulated Enclosures, Drilling and Cutout, dimensional drawing 98 Drilling Dimensions 30 30 44 114 M4 28 33 181 55 171 160 M4 97 Drilling Dimensions - XTPAXENAS55..., XTPXENASEM55..., XTPAXENCS65..., XTPAXENCSEM65.. + XTPAXPL1 43 Dia. 64 48 4R 116 - 118 64 19.5 48 62 70 - 72 Mounting Depth: - 240 At least 100 up to Cover Hinge Mounting Cutout - XTPAXENCF... front edge of the panel door/cover T echn ic al de ta ils Rotary Handle Mechanism - XTPAXRHM... 146 Technical details PG03407001U - June 2006 Manual Motor Protectors, Eaton Numbering System XT PR 012 B C1 Designation Trip Class XT = XT IEC Power Control C1 = Class 10 Blank = Magnetic only (No thermal trip) Type PB = PR = PM = PT = Frame Size Manual Motor Protector -- Pushbutton Manual Motor Protector -- Rotary Manual Motor Protector -- Magnetic Only Manual Transformer Protector (High Mag.) B= 45 mm D = 55 mm Current Ratings B Frame P16 = P25 = P40 = P63 = 001 = 1P6 = 2P5 = 004 = 0.16A 0.25A 0.40A 0.63A 1A 1.6A 2.5A 4A 6P3 = 010 = 012 = 016 = 020 = 025 = 032 = 6.3A 10A 12A 16A 20A 25A 32A D Frame 16A 25A 32A 40A 050 = 50A 058 = 58A 063 = 63A T echn ic al de ta ils 016 = 025 = 032 = 040 = PG03407001U - June 2006 Technical details 147 Manual Motor Protectors, Frames B and D, Technical Data and Standards XTPBP16B - XTPB016B Standards General Climatic proofing Ambient temperature, C Storage Open Enclosed Temperature compensation to IEC/EN 60947, VDE 0660, C Operating range, C Temperature compensation residual error for T > 20C, %/K Mounting position XTPRP16B - XTPR032B XTPR016D - XTPR063D XTPMP16B -1) XTPM032B XTPTP16B - XTPT025B IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 -25 / 80 -25 / 55 -25 / 40 -25 / 80 -25 / 55 -25 / 40 -25 / 70 -25 / 55 -25 / 40 -25 / 80 -25 / 55 -25 / 40 -25 / 80 -25 / 55 -25 / 40 -5 / 40 -25 / 55 < 0.25 -5 / 40 -25 / 55 < 0.25 -5 / 40 -25 / 55 < 0.25 -5 / 40 -25 / 55 < 0.25 -5 / 40 -25 / 55 < 0.25 90 90 90 90 90 90 90 Direction of incoming supply Degree of protection Device Terminals Protection against direct contact Shock resistance half-sinusoidal shock 10 mS to IEC 60068-2-27 (g) Altitude (m) Terminal capacity Solid (mm2) Flexible with ferrule to DIN 46228, (mm2) Solid or stranded (AWG) Terminal screw tightening torque Main cable, Nm Control circuit cable, Nm As required As required 90 As required As required As required IP20 IP20 IP00 IP00 Finger- and back-of-hand proof 25 25 IP20 IP00 IP20 IP00 IP20 IP00 15 25 25 max. 2000 max. 2000 max. 2000 max. 2000 max. 2000 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 1 x (1 - 50) 2 x (1 - 35) 1 x (1 - 35) 2 x (1 - 35) 14 - 2 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 1 x (1 - 6) 2 x (1 - 6) 1 x (1 - 6) 2 x (1 - 6) 18 - 10 1.7 1 1.7 1 3 1.7 1 1.7 1 1 Main contacts Rated impulse withstand voltage (Uimp), V 6000 6000 6000 6000 6000 AC Overvoltage category / pollution degree Rated operational voltage (Ue), V AC III / 3 690 III / 3 690 III / 3 690 III / 3 690 III / 3 690 16 or current setting of the overcurrent release 40 - 60 6 32 or current setting of the overcurrent release 40 - 60 6 63 or current setting of the overcurrent release 40 - 60 22 32 or current setting of the overcurrent release 40 - 60 6 25 or current setting of the overcurrent release 40 - 60 6 50,000 50,000 25 100,000 100,000 40 30,000 30,000 40 100,000 100,000 40 100,000 100,000 40 T echn ic al de ta ils Rated uninterrupted current = rated operational current (Iu = Ie) in amperes Rated frequency, Hz Current heat loss (3-pole at operating temperature), W Lifespan, mechanical (ops) Lifespan, electrical (AC-3 at 400 V) (ops) Maximum operating frequency, operations/ hr Note: Single-phasing sensitivity to IEC/EN 60947-4-1, VDE 0660 Part 102. Can be snap-fit to IEC/EN 60715 top-hat (DIN) with 7.5 or 15 mm height. Service Factor (SF) -- Setting Ir of current scale in dependence of load factor: SF = 1.15 -> Ir = 1 x In mot SF = 1 -> Ir = 0.9 x In mot 1) When using the XTPM as short-circuit protection for motors with heavy starting duty, the rated operational current I must be derated during engineering with the following factors: e Class 5 = 1.0, Class 10 = 1.0, Class 15 = 0.82, Class 20 = 0.71 Class 25 = 0.63, Class 30 = 0.58, Class 35 = 0.53, Class 40 = 0.50 148 Technical details PG03407001U - June 2006 Manual Motor Protectors, Frames B and D, Technical Data and Standards (Continued) XTPBP16B - XTPB016B XTPRP16B - XTPR032B XTPR016D - XTPR063D XTPMP16B - XTPM032B XTPTP16B - XTPT025B 60 (up to XTPR016B) 40 (XTPR020B - XTPR032B) 60 60 (up to XTPM016B) 40 (XTPM020B - XTPR032B) 60 (up to XTPT016B) 40 (XTPT020B - XTPT025B) 63 63 (3 contacts in series) 0.6 - 1.0 32 25 -- 0.6 - 1.0 14 14 14 20% 20% -- 20% IEC/EN 60947-1-1, VDE 0660 Part 102 Main contacts (Continued) Short-circuit rating AC DC (kA) See Page 150. 60 Motor switching capacity AC-3 (up to 690 V) in amperes DC-5 (up to 250 V) in amperes 16 16 Overload release setting range (x Iu) 0.6 - 1.0 32 25 (3 contacts in series) 0.6 - 1.0 Fixed short-circuit release (x Iu) 14 14 Short-circuit release tolerance Phase-failure sensitivity 20% 20% IEC/EN 60947-1-1, VDE 0660 Part 102 Manual Motor Protectors, Auxiliary Contacts, Technical Data and Standards Description XTPAXSA_ _ Rated Impulse withstand voltage, Uimp (V AC) 6000 4000 6000 XTPA(B)XFAEM_ XTPAXSATR_ _ _ 4000 6000 Overvoltage category/pollution degree Rated operational voltage Ue (VAC) III/3 III/3 III/3 III/3 III/3 500 250 440 250 500 250 440 250 500 250 690 690 690 690 690 3.5 2 1 1 -- -- 3.5 2 1 1 -- -- 3.5 2 1 2 1.5 1 0.25 -- -- -- -- 2 1.5 1 0.25 -- -- -- -- 2 1.5 1 0.25 > 0.1 > 0.1 >5 > 0.1 > 0.01 > 0.05 > 0.1 >1 > 0.1 > 0.005 Ue (VDC) Safe isolation to VDE 0106 Part 101 and Part 101/A1 Between auxiliary contacts and main contacts (V AC) Rated operational current AC-15 220 - 240 V, Ie (A) 380 - 415 V, Ie (A) 440 - 500 V, Ie (A) DC-13 L/R < 100 ms 24 V, Ie (A) 60 V, Ie (A) 110 V, Ie (A) 220 V, Ie (A) XTPAXFA_ _ XTPAXCMSA_ _ Mechanical, operations (x 106) 6) Electrical, operations (x 10 Contact reliability (@ Ue = 24V DC, Umin - 17V, < 10-8 < 1 fault at 1 x 108 operations Imin = 5.4 mA, fault probability () Positively driven contacts to ZH 1/457 Short-circuit rating without welding Fuseless Fuse (A gG/gL) Terminal Capacity Yes - Yes - - FAZ-B4/1-HI 10 - 10 FAZ-B4/1-HI 10 - 10 FAZ-B4/1-HI 10 Solid or flexible conductor with ferrule (mm2) Solid or stranded (AWG) 0.75 -2.5 0.75 - 1.5 0.75 - 2.5 0.75 - 1.5 0.75 - 2.5 18 - 14 18 - 16 18 - 14 18 - 16 18 - 14 PG03407001U - June 2006 Technical details T echn ic al de ta ils Lifespan 149 Manual Motor Protectors, Undervoltage Release, Technical Data and Standards Description Cross-sections XTPAXUVR... Solid or flexible conductor with ferrule (mm2) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (18 - 14) 2 x (18 - 14) Solid or stranded (AWG) Main Contacts Rated operational voltage, Ue (V AC) 42 - 480 Rated operational voltage, Ue (V DC) 24 - 250 Pick-up voltage, x Us 0.85 - 1.1 Drop-out voltage, x Us 0.7 - 0.35 Power Consumption Pick-up AC (VA) Sealing AC (VA) 5 3 Manual Motor Protectors, Current Limiter, Technical Data and Standards Description Rated Impulse withstand Voltage (Uimp), V AC XTPAXCL 6000 Overvoltage Category/ Pollution Degree Rated operational voltage, Ue (V AC) III/3 690 Rated interrupted current = Rated operational current (lu = le) in amperes 63 Manual Motor Protectors, Shunt Release, Technical Data and Standards Description Cross-sections XTPAXSR __ Solid or flexible conductor with ferrule (mm2) 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) 1 x (18 - 14) 2 x (18 - 14) T echn ic al de ta ils Solid or stranded (AWG) 150 Main Contacts Rated operational voltage, Ue (V AC) 42 - 480 Rated operational voltage, Ue (V DC) 24 - 250 AC Operating Range, x Us 0.7 - 1.1 DC Operating Range, x Us (intermittent operation 5s) 0.7 - 1.1 Power Consumption Pick-up AC (VA) Sealing AC (VA) Pick-up DC (VA) Sealing DC (VA) 5 3 3 3 Technical details PG03407001U - June 2006 Manual Motor Protectors, Frames B and D, Time Current Curve Characteristics The time/current characteristic, the current limiting characteristics and the I2t characteristics were determined in accordance with DIN VDE 0660 and IEC 60 947. The tripping characteristic of the inverse-time delayed overload releases (thermal overload releases or "a" releases) for DC and AC with a frequency of 0 to 400 Hz also apply to the time/current characteristic. The characteristics apply to the cold state. At operating temperature, the tripping times of the thermal releases are reduced to approximately 25%. Under normal operating conditions, all three poles of the device must be loaded. The three main conducting paths must be connected in series in order to protect single-phase or DC loads. With 3-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is 20% and thus in accordance with DIN VDE 0165. The tripping characteristics for the instantaneous, electromagnetic overcurrent releases (short-circuit releases or "n" releases) are based on the rated current In, which is also the maximum value of the setting range for circuit-breakers with adjustable overload releases. If the current is set to a lower value, the tripping current of the "n" release is increased by a corresponding factor. The characteristics of the electromagnetic overcurrent releases apply to frequencies of 50/60 Hz. Appropriate correction factors must be used for lower frequencies up to 16-2/3 Hz, for higher frequencies up to 400 Hz and for DC. 2h 20 10 5 Minutes XTPB, XTPR Frame B 2 1 40 20 10 5 Seconds Seconds Minutes Time/current characteristics, current limiting characteristics and I2t characteristics are available on request. XTPT 2 1 200 200 50 20 50 20 5 5 2 2 1.5 2 6 8 10 15 20 3 4 x Rated Operational Current 30 1.5 2 6 8 10 15 20 3 4 x Rated Operational Current 30 MMP Tripping Characteristics -- XTPR Frame D T echn ic al de ta ils MMP Tripping Characteristics -- XTPB, XTPR Frame B and XTPT (not for XTPM) XTPR Frame D 2 1 40 20 10 5 1 Milli-seconds Milli-seconds 2 2h 20 10 5 PG03407001U - June 2006 Technical details 151 32 A 25 A 20 A 16 A 10 A/12 A 6.3 A 100 XTPR Frame D ^ ID [kA] 2 * cc 10 XTPB 8 XTPR Frame B ^ ID 6 XTPM [kA] 4 3 4.0 A 2* cc 2 1 0.8 0.6 2.5 A 0.4 0.3 1.6 A 0.2 1A 0.1 0.08 0.06 10 0.63 A 0.04 0.03 0.4 A 0.02 0.015 0.01 63/58 A 50/40/32 A 25 A 16 A Ue = 400 V 1 1.5 2 3 4 Ue = 400 V 0.25 A 6 8 10 15 20 3040 60 80100 cc rms [kA] 100 MMP Let-Through Tripping Characteristics -- XTPR Frame D av -w alf th 10 A 1s 2 1.5 104 8 6 10 XTPR Frame B 25 A XTPM 20 A 16 A e 106 8 i dt 6 2 [A s] 4 3 1 cc rms [kA] MMP Let-Through Tripping Characteristics -- XTPB, XTPR Frame B, XTPT XTPR Frame B, XTPT 2 1 6.3 A 4.0 A 4 3 2 2.5 A 1.5 103 8 6 1.6 A 4 3 T echn ic al de ta ils 2 152 1.5 102 1 1.5 2 Ue = 400 V 3 4 1.0 A 6 8 10 15 20 3040 6080100 cc rms [kA] MMP Let-Through Tripping Characteristics - XTPR Frame B, XTPM Technical details PG03407001U - June 2006 Manual Motor Protectors, Frames B and D, Short Circuit Ratings Iu uninterrupted current Iu = Rated operational current Ie. conditional short circuit current I q -- IEC/EN 60947-4-1. ultimate short circuit breaking capacity I cu -- IEC/EN 60947-2. operational short circuit breaking capacity I cs -- IEC/EN 60947-2. 230V Iq I cu I cs Fuse 400V Iq I cu I cs Fuse 2)3) A kA kA kA A 440V Iq I cu I cs 2)3) kA kA kA A XTPB with classification Type "1" and Type "2" 0.16 - 1 50 50 50 50 50 50 50 50 1.6 50 50 50 50 50 50 50 50 2.5 50 50 50 50 50 50 50 50 4 50 50 50 50 50 50 50 50 6.3 50 50 50 50 50 50 50 50 10 50 50 50 50 50 50 50 50 12 50 50 50 50 50 50 10 50 XTPR...BC1, XTPT, XTPM with classification Type "1" and Type "2" 0.16 - 1 150 1) 150 1) 150 1) N 150 1) 150 1) 150 1) N Fuse 500V Iq I cu I cs Fuse 2)3) 690V Iq I cu I cs kA kA kA A kA kA kA A 2)3) kA kA kA A 50 50 50 50 50 42 15 50 50 50 50 50 42 15 50 50 50 50 50 10 10 50 50 50 50 50 50 50 Fuse 2)3) 1) 1) 1) 50 1) 1) 1) N 1) 1) 1) N 1.6 150 1) 150 1) 150 1) N 150 1) 150 1) 150 1) N 1) 1) 1) 50 1) 1) 1) N 1) 1) 1) N 2.5 1) 1) 1) N 1501) 150 1) 150 1) N 1) 1) 1) 50 1) 1) 1) N 5 5 5 50 1) 150 1) 150 1) 1) 1) 1) 1) 1) 1) 1) 42 15 15 15 10 10 42 15 15 15 10 10 10 10 10 10 10 10 50 50 50 50 50 50 50 50 1) 150 1) 10 10 10 10 10 N N N 50 50 50 50 50 1) 42 42 15 15 6 6 6 42 42 15 15 6 6 6 6 6 6 6 6 6 6 N 50 50 50 50 50 50 50 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 N N 100 100 100 160 160 45 45 45 45 45 45 45 45 45 45 45 45 45 45 25 25 25 25 25 25 25 100 100 100 100 100 160 160 15 15 15 15 15 15 15 15 15 15 15 15 15 15 100 100 100 100 100 160 160 8 8 5 5 5 5 5 8 8 5 5 5 5 5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 100 100 100 100 100 160 160 150 150 1) 150 1) 1) N 150 150 150 150 4 6.3 150 1) 150 1) 1501) N 150 1) 150 1) 1) 1) 1) 10 N 150 150 150 1501) 1501) 12 50 50 50 10 50 50 16 50 50 10 50 50 50 20 50 50 10 50 50 50 25 50 50 10 50 50 50 32 50 50 10 50 50 50 XTPR...DC1 with classification Type "1" and Type "2" N 16 150 1) 1501) 150 1) 150 1) 25 1) 1) 25 N 25 150 150 150 1) 1501) 25 100 50 50 50 50 32 50 50 25 50 50 100 40 50 50 50 25 100 50 50 58 50 50 25 160 50 50 63 50 50 25 160 50 50 XTPR...BC1, XTPT, XTPM with Current Limiter XTPAXCL 1) 1) 1) 1) 1) N 0.16 - 1 150 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 20 N 1.6 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 20 N 2.5 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 20 20 20 N 4 6.3 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) N N 1) 1) N N 1) 1) N N 1) 1) 1) 50 N N 20 20 20 20 20 20 N N 10 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 20 N 20 20 20 N 12 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 20 N 5 5 2.5 N 16 20 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) N N 1) 1) N N 1) 1) N N 1) 1) 10 10 20 10 N N 5 5 5 5 2.5 N 2.5 N 25 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 10 10 10 N 5 5 2.5 N 1) 1) 1) 1) 1) 1) N 1) 1) 1) N 10 10 10 N 5 5 2.5 N N 1) 1) 1) N 1) 1) 1) N 1) 1) 20 N 1.6 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 20 N 2.5 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 40 40 20 N 4 6.3 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) N N 1) 1) N N 1) 1) N N 1) 1) 50 N N 40 20 40 20 20 20 N N 10 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 40 N 20 20 20 N 12 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 1) 1) 40 N 10 10 2.5 N 16 20 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) N N 1) 1) N N 1) 1) N N 1) 1) 20 20 40 20 N N 10 10 10 10 2.5 N 2.5 N 25 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 20 20 20 N 10 10 2.5 N 32 1) 1) 1) N 1) 1) 1) N 1) 1) 1) N 20 20 20 N 10 10 2.5 N 32 N XTPR...BC1, XTPT, XTPM with (2) Current Limiters XTPAXCL 1) 1) 1) 1) 1) 1) 0.16 - 1 N T echn ic al de ta ils Rated Rated Rated Rated 1) No upstream protective device required, as it is the auto-protected range (100/150 kA -- Frame B, 150 kA -- Frame D). 2) 3) N = Not required. XTPR...BC1, XTPT, XTPM -- Required back-up fuse if the short circuit current exceeds the rated conditional short circuit current (Icc > Iq); XTPB, XTPR...DC1 -- Fuse (A gG/gL) for enhancing the switching capacity of the motor protective circuit breaker to 100 kA. PG03407001U - June 2006 Technical details 153 Manual Motor Protectors, FramesB and D, Ratings for Goup Motor Applications - UL 508/CSA C22.2 No.14 Eaton list Number Rated Uninterrupted Current -- Iu (Amps) FLA Adjustment Range / Overload Release -- Ir (Amps) Short Circuit Release -- Irm (Amps) Maximum Protective Device for UL/CSA Group Protection Max. RMS Sym Current -- Maximum Fuse 600V (kA) Rating (A) w/Current w/Current Limiter -- Limiter -- XTPAXCL XTPAXCL XTPB -- Frame B, Manual Motor Protector with Thermal and Magnetic Trip XTPBP16BC1 0.16 0.1 - 0.16 2.2 50 -- XTPBP25BC1 0.25 0.16 - 0.25 3.5 50 -- XTPBP40BC1 0.4 0.25 - 0.4 5.6 50 -- XTPBP63BC1 0.63 0.4 - 0.63 8.8 50 -- XTPB001BC1 1 0.63 - 1 14 50 -- XTPB1P6BC1 1.6 1 - 1.6 22 50 -- XTPB2P5BC1 2.5 1.6 - 2.5 35 50 -- XTPB004BC1 4 2.5 - 4 56 50 -- XTPB6P3BC1 6.3 4 - 6.3 88 50 -- 50 XTPB010BC1 10 6.3 - 10 140 10 50 XTPB012BC1 12 8 - 12 168 10 XTPB016BC1 16 10 - 16 224 50 1) 10 1) T echn ic al de ta ils 2) 3) 154 600 1) 1) 600 1) 1) 600 1) 125 1)2) 600 1) XTPB025BC1 10 18 150 125 XTPR -- Frame B (all Screw and Spring Cage terminal options), Manual Motor Protector with Thermal and Magnetic Trip XTPRP16BC1 0.16 0.1 - 0.16 2.2 50 -- 600 -- 600 XTPRP25BC1 0.25 0.16 - 0.25 3.5 50 -- 600 -- 600 XTPRP40BC1 0.4 0.25 - 0.4 5.6 50 -- 600 -- 600 XTPRP63BC1 0.63 0.4 - 0.63 8.8 50 -- 600 -- 600 XTPR001BC1 1 0.63 - 1 14 50 -- 600 -- 600 XTPR1P6BC1 1.6 1 - 1.6 22 50 -- 600 -- 600 XTPR2P5BC1 2.5 1.6 - 2.5 35 50 -- 600 -- 600 XTPR004BC1 4 2.5 - 4 56 50 -- 600 -- 600 XTPR6P3BC1 6.3 4 - 6.3 88 50 -- 600 -- 600 XTPR010BC1 10 6.3 - 10 140 10 50 150 600 125 2) XTPR012BC1 12 8 - 12 168 10 50 150 600 125 XTPR016BC1 16 10 - 16 224 10 50 150 600 125 2) 600 1) XTPR020BC1 20 16 - 20 280 10 18 XTPR025BC1 25 20 - 25 350 10 18 XTPR032BC1 32 25 - 32 448 10 18 XTPR -- Frame D, Manual Motor Protector with Thermal and Magnetic Trip XTPR016DC1 16 10 - 16 224 10 -- XTPR025DC1 25 16 - 25 350 10 -- XTPR032DC1 32 25 - 32 448 10 -- XTPR040DC1 40 32 - 40 560 10 -- -- 700 40 - 50 50 XTPR050DC1 10 1) -- 812 50 - 58 58 XTPR058DC1 10 1) -- 882 55 - 63 65 XTPR063DC1 10 1) XTPT -- Frame D, Manual Motor Protector with Thermal and Magnetic Trip XTPTP16BC1 0.16 0.1 - 0.16 2.4 50 -- XTPTP25BC1 0.25 0.16 - 0.25 4.25 50 -- XTPTP40BC1 0.4 0.25 - 0.4 6.8 50 -- XTPTP63BC1 0.63 0.4 - 0.63 12 50 -- XTPT001BC1 1 0.63 - 1 20 50 -- XTPT1P6BC1 1.6 1 - 1.6 32 50 -- XTPT2P5BC1 2.5 1.6 - 2.5 50 50 -- XTPT004BC1 4 2.5 - 4 84 50 -- XTPT6P3BC1 6.3 4 - 6.3 141 50 -- XTPT010BC1 XTPT012BC1 XTPT016BC1 XTPT020BC1 XTPT025BC1 1) 150 1) -- -- -- -- -- -- -- -- -- 600 600 600 1) 20 25 10 12 16 20 25 16 - 20 20 - 25 6.3 - 10 8 - 12 10 - 16 16 - 20 20 - 25 280 350 224 224 358 380 420 10 18 1) 10 10 10 10 10 1) 600 600 600 600 600 600 600 600 600 125 2) 125 2) 1) 3) 1) -- -- -- -- -- -- -- -- -- 600 600 w/Current Limiter -- XTPAXCL 1) XTPB020BC1 3) 600 600 600 600 600 600 600 600 600 150 150 Circuit Breaker Max (A) 150 1) 50 50 50 18 18 125 150 150 150 600 600 600 125 125 125 600 600 600 600 600 600 600 -- -- -- -- -- -- -- 600 600 600 600 -- -- -- -- -- -- -- 600 1) 600 1) 600 1) 600 1) 600 1) 600 1) 600 600 600 600 600 600 600 600 600 -- -- -- -- -- -- -- -- -- 600 600 600 600 600 600 600 600 600 -- -- -- -- -- -- -- -- -- 150 150 150 150 150 600 600 600 600 600 125 2) 125 125 125 125 600 600 600 600 600 Rating is pending UL approval, available September 2005. Contact Eaton for availability. 22kA 600V AC IEC/EN 60947-4-1 Technical details -- -- -- -- -- -- -- -- -- 600 600 600 PG03407001U - June 2006 Manual Motor Protectors, MMC and Manual Motor Controllers MMC, Frames B and D, Ratings Short Circuit Release -- Irm (Amps) Rated Short Circuit Breaking Capacity (kA) 240V 480/277V 600/347V XTSC & XTSR Manual Motor Controllers (MMC) / Starter Combinations XTSCP25BB_ XTSRP25BB_ 0.25 0.16 - 0.25 XTSCP40BB_ XTSRP40BB_ 0.4 0.25 - 0.4 XTSCP63BB_ XTSRP63BB_ 0.63 0.4 - 0.63 XTSC001BB_ XTSR001BB_ 1 0.63 - 1 XTSC1P6BB_ XTSR1P6BB_ 1.6 1 - 1.6 XTSC2P5BB_ XTSR2P5BB_ 2.5 1.6 - 2.5 XTSC004BB_ XTSR004BB_ 4 2.5 - 4 XTSC6P3BB_ XTSR6P3BB_ 6.3 4 - 6.3 XTSC010BB_ XTSR010BB_ 10 6.3 - 10 XTSC012BB_ XTSR012BB_ 12 8 - 12 XTSC016BC_ XTSR016BC_ 16 10 - 16 XTSC020BC_ XTSR020BC_ 20 16 - 20 XTSC025BC_ XTSR025BC_ 25 20 - 25 XTSC032BC_ XTSR032BC_ 32 25 - 32 XTSC016DC_ XTSR016DC_ 16 10 - 16 XTSC025DC_ XTSR025DC_ 25 16 - 25 XTSC032DC_ XTSR032DC_ 32 25 - 32 XTSC040DD_ XTSR040DD_ 40 32 - 40 XTSC050DD_ XTSR050DD_ 50 40 - 50 XTSC058DD_ XTSR058DD_ 58 50 - 58 XTSC063DD_ XTSR063DD_ 63 55 - 63 3.5 5.6 8.82 14 22.4 35 56 88.2 140 168 224 280 350 448 224 350 448 560 700 812 882 50 50 50 50 50 50 50 50 50 50 18 18 18 18 50 50 50 50 50 50 50 50 50 50 50 50 50 42 42 18 18 18 50 50 50 50 50 1) 50 1) 50 1) 50 1) 1) 50 1) XTFC & XTFR Manual Motor Controllers (MMC), UL 508 Type F XTFCP25BB_ XTFRP25BB_ 0.25 0.16 - 0.25 XTFCP40BB_ XTFRP40BB_ 0.4 0.25 - 0.4 XTFCP63BB_ XTFRP63BB_ 0.63 0.4 - 0.63 XTFC001BB_ XTFR001BB_ 1 0.63 - 1 XTFC1P6BB_ XTFR1P6BB_ 1.6 1 - 1.6 XTFC2P5BB_ XTFR2P5BB_ 2.5 1.6 - 2.5 XTFC004BB_ XTFR004BB_ 4 2.5 - 4 XTFC6P3BB_ XTFR6P3BB_ 6.3 4 - 6.3 XTFC010BB_ XTFR010BB_ 10 6.3 - 10 XTFC012BB_ XTFR012BB_ 12 8 - 12 XTFC016BC_ XTFR016BC_ 16 10 - 16 XTFC020BC_ XTFR020BC_ 20 16 - 20 XTFC025BC_ XTFR025BC_ 25 20 - 25 XTFC032BC_ XTFR032BC_ 32 25 - 32 XTFC016DC_ XTFR016DC_ 16 10 - 16 XTFC025DC_ XTFR025DC_ 25 16 - 25 XTFC032DC_ XTFR032DC_ 32 25 - 32 XTFC040DD_ XTFR040DD_ 40 32 - 40 3.5 5.6 8.82 14 22.4 35 56 88.2 140 168 224 280 350 448 224 350 448 560 50 50 50 50 50 50 50 50 50 50 18 18 18 18 50 50 50 50 1) Rated Current -- Ie (Amps) FLA Adjustment Range / Overload Release -- Ir (Amps) 50 50 50 50 50 50 50 50 50 50 42 18 18 18 18 50 50 50 50 50 50 50 50 50 50 50 50 50 -- -- -- -- -- -- -- -- -- -- -- -- 50 50 50 50 50 50 50 50 50 -- -- -- -- -- -- -- -- -- T echn ic al de ta ils Eaton list number Non-reversing Reversing Ratings pending UL approval. Contact Eaton for availability. PG03407001U - June 2006 Technical details 155 Manual Motor Protectors, Frames B and D, Wiring diagrams Manual Motor Pprotectors with XTPAXSATR20 Signalling switch. Separate "Short-Circuit" and "Tripped" signals. Manual Motor Protectors with pushbutton or EMERGENCY-STOP button in the system. L1 L2 L3 N L1 L2 L3 N F1 Max. 10A F1 Max. 10A 1 3 5 F2 Max. 10A H1 H2 4.43 1 4.13 3 5 D1 07 U 2 4 4.44 6 Q1 4.14 2 S1 Q1 4 D2 08 6 F4 S1 S2 S3 1 H1: "Short-Circuit" Signal H2: "Tripped" Signal (MMP can be tripped by overload, short-circuit, or auxiliary releases) The undervoltage release with leading auxiliary contac prevents formation of parasitic voltages in the control when the MMP position is "OFF". In the tripped positio the MMP, opening of these contacts is not assured. H1; H2 F1 Q1 S1 F1; F2 Q1 F4 S1; S2; S3 3 5 I> I> I> 2 4 6 Indicator Lights Fuses MMP Signalling Contact 1 Fuses MMP Undervoltage Release OFF Pushbuttons in the System 3 5 I> I> I> 2 4 6 T echn ic al de ta ils Manual Motor Protectors, XTPB, XTPR 1P and 2P Circuits with DC and AC Current 156 Technical details PG03407001U - June 2006 Manual Motor Protectors, Protection of PVC insulated cables against thermal overload at Short Circuit Min. Cross-Section Protected 380-415V, 50 Hz, Cu mm2 4 2.5 1.5 1 Device Type 0.75 ... XTPRP16BC1 XTPR6P3BC1 XTPR010BC1 XTPR016BC1 XTPR020BC1 XTPR025BC1 XTPR016DC1 XTPR025DC1 XTPR032DC1 XTPR040DC1 XTPR050DC1 XTPR058DC1 XTPR063DC1 The table indicates which minimum cable cross-sections are protected by XTPR motor protective circuit breakers up to their rated conditional short circuit current I q . Manual Motor Protectors, Fuseless Installation with XTPR, Back-Up Protection Diagrams XTPR...B Inherently short-circuit-proof Back-up protection range with XTPAXCL Rated short-circuit breaking capacity range XTPR...B cn cc Inherently short-circuit proof cc rms [kA] 415V AC 50 30 20 16 XTPR...B + XTPAXCL 100 XTPR...B XTPR...B 10 6 0.16... 1016 20 25 Rated Current n [A] 100 XTPR...D + XTPAXCL 50 30 20 16 10 Inherently short-circuit-proof Rated short-circuit breaking capacity range XTPR...D cn cc Inherently short-circuit proof cc rms [kA] Back-up protection range with XTPAXCL Rated Current n [A] XTPR...D T echn ic al de ta ils XTPR...D 415V AC 6 16... 25 PG03407001U - June 2006 32 40 50 63 Rated Current n [A] Technical details 157 8 Technical details Manual Motor Controllers Manual Motor Controllers Frame B, Dimensional drawing 95.7 49.7 TO TERMINALS 36.3 TO TERMINALS 45 209.2 Manual Motor Controllers Frames B and D, technical data and Specifications T echn ic al de ta ils Factory Assembled Motor Protective Device with Thermal and Magnetic Trip + Contactor(s) Eaton list number FLA Adjustment Assembled Manual/ Manual Assembled Manual/ Manual Range / Motor Controller -- Motor Controller -- Overload Non-reversing 4) Reversing 4) Release -- Ir (Amps) XTSC & XTSR Manual Motor Controllers (MMC) / Starter Combinations XTSCP25BB_ XTSRP25BB_ 0.16 - 0.25 XTSCP40BB_ XTSRP40BB_ 0.25 - 0.4 XTSCP63BB_ XTSRP63BB_ 0.4 - 0.63 XTSC001BB_ XTSR001BB_ 0.63 - 1 XTSC1P6BB_ XTSR1P6BB_ 1 - 1.6 XTSC2P5BB_ XTSR2P5BB_ 1.6 - 2.5 XTSC004BB_ XTSR004BB_ 2.5 - 4 XTSC6P3BB_ XTSR6P3BB_ 4 - 6.3 XTSC010BB_ XTSR010BB_ 6.3 - 10 XTSC012BB_ XTSR012BB_ 8 - 12 XTSC016BC_ XTSR016BC_ 10 - 16 XTSC020BC_ XTSR020BC_ 16 - 20 XTSC025BC_ XTSR025BC_ 20 - 25 XTSC032BC_ XTSR032BC_ 25 - 32 XTSC016DC_ XTSR016DC_ 10 - 16 XTSC025DC_ XTSR025DC_ 16 - 25 XTSC032DC_ XTSR032DC_ 25 - 32 XTSC040DD_ XTSR040DD_ 32 - 40 XTSC050DD_ XTSR050DD_ 40 - 50 XTSC058DD_ XTSR058DD_ 50 - 58 XTSC063DD_ XTSR063DD_ 55 - 63 Maximum Motor Ratings -- P 1) Maximum Motor kW Rating AC-3 -- P (kW) Three-Phase 220-240V 380-415V 440V 500V 660-690V -- 0.06 0.09 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 5.5 7.5 4 5.5 7.5 11 14 17 18.5 0.06 0.12 0.25 0.37 0.75 1.1 2.2 3 4 5.5 9 12.5 15 22 9 12.5 17.5 22 30 37 37 0.12 0.18 0.25 0.55 1.1 1.5 3 4 7.5 11 12.5 15 22 30 12.5 22 22 30 45 55 55 0.06 0.09 0.18 0.25 0.55 0.75 1.5 2.2 4 5.5 7.5 9 11 15 7.5 12.5 15 20 25 30 34 0.06 0.12 0.18 0.25 0.55 1.1 1.5 3 4 5.5 9 11 12.5 15 9 12.5 17.5 22 30 37 37 1) Select Manual Motor Protectors by full load amperes. Maximum Motor Ratings (kW) are for reference only. 2) 3) 4) 158 In this range, calculate motor rating according to rated current. Specified values to NEC Table 430-150. Ratings pending UL approval. Contact Eaton for availability. Underscore (_) indicates Coil Suffix required. Technical details PG03407001U - June 2006 Manual Motor Controllers, Eaton Numbering System XT SC 012 B B A Design Coil Voltage X = XT IEC Power Control Type Manual Motor Controller -- FVNR Manual Motor Controller -- FVR Manual Motor Controller, UL 508 Type F -- FVNR Manual Motor Controller, UL 508 Type F -- FVR Rated Current of MMP B-Frame P16 = P25 = P40 = P63 = 001 = 1P6 = 2P5 = 004 = 6P3 = 010 = 012 = 016 = 020 = 025 = 032 = 0.16A 0.25A 0.40A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 12A 16A 20A 25A 32A D-Frame 016 = 025 = 032 = 040 = 050 = 058 = 060 = 40A 58A 60A 16A 20A 25A 32A 110V 50 Hz, 120V 60 Hz 220V 50 Hz, 240V 60 Hz 415V 50 Hz, 480V 60 Hz 550V 50 Hz, 600V 60 Hz 208V 50 Hz 230V 50 Hz 190V 50 Hz, 220V 60 Hz 240V 50 Hz, 277V 60 Hz 380V 50 Hz, 440V 60 Hz 400V 50 Hz 380V 60 Hz 12V 50/60 Hz 24V 50/60 Hz 24V 50 Hz 42V 50 Hz, 48V 60 Hz 48V 50 Hz 120V DC 220V DC 12V DC 24V DC 48V DC Frame Size -- Contactor B = 45 mm, 7 to 15A C = 45 mm, 18 to 32A D = 55 mm, 40 to 65A Frame Size -- MMP B = 45 mm, 0.1 to 32A D = 55 mm, 16 to 63A T echn ic al de ta ils SC = SR = FC = FR = A= B= C= D= E= F= G= H= L= N= P= R= T= U= W= Y= AD = BD = RD = TD = WD = PG03407001U - June 2006 Technical details 159 8 Technical details User's Guide to IEC Type 1 and Type 2 Coordination What is it? The International Electrotechnical Commission (IEC) developed short circuit performance criteria for contactors and starters called Type 1 coordination and Type 2 coordination. This defines motor controller protection levels following a short circuit fault. In order to achieve this performance, the combination of a motor controller (contactor or starter) and short circuit protective device (manual motor protector, circuit breaker or fuse) must meet the following criteria as specified by IEC 609474-1 -- Low voltage switchgear and controlgear -- Part 4-1: Contactors and motor-starters -- Electromechanical contactors and motor-starters: Type 1 Coordination requires that under short circuit conditions, the contactor or starter shall cause no danger to persons or installation and may not be suitable for further service without repair and replacement of parts. In this case, significant damage is allowed to the contactor/starter (e.g. contact welding, burning, or disintegration) and the overload relay (e.g. component harm or heater element burn-out). Type 2 Coordination requires that under short circuit conditions, the contactor or starter shall cause no danger to persons or installation and shall be suitable for further use. The risk of contact welding is recognized, in which case the manufacturer shall indicate the measures to be taken as regards to the maintenance of the equipment. In this case, the contactor/starter is able to continue use after the occurrence of a short circuit fault. Light contact burning or tack welding may occur provided the contacts are easily separable. Who benefits and why? Achieving an acceptable level of short circuit coordination requires knowledge about the application, product standards, installation codes and the attributes of the many short circuit protective devices (SCPDs) that are available. Extensive testing must be completed and certified in order to achieve a Type 1 or 2 rating. IEC 60947-4-1 offers precise definitions of allowable damage in order to guide users to the right product with the right protection. Generally speaking, most users expect Type 2 protection in their applications. With certifying agencies varying from countryto-country and continent-to-continent, users will sometimes mistakenly assume that Type 2 coordination has been achieved if their motor branch circuit components are CE marked, UL Listed Type E or F and/or CSA Certified. This is not necessarily true. At the forefront of Type 2 benefits comes the assurance that the device poses no threat of danger to the person or installation. Furthermore, with increased emphasis placed on reducing downtime to increase productivity, proper application and selection of motor branch circuit devices is more important than ever. By selecting the proper type of protection, the working environment and employees can be protected against hazardous fault conditions and the performance of contactors and overload relays in the branch circuit can be maximized. Type 2 protection provides confidence that motor control components will be operable following a short circuit fault. This reusability translates into hundreds or even thousands of pounds in savings due to reduced downtime and replacement costs. TYPE 2 Coordination = Safety + Less Downtime =Pounds How does Eaton comply? It is important to understand the short circuit testing pass/fail criteria of the applicable product standards (UL 508, CSA C22.2 No. 14 and IEC 60947) when specifying products for each application. Each standard requires that devices are capable of withstanding minimum short circuit currents (based on the starter's rating). UL and CSA refer to the minimum rating as the Standard Fault Short Circuit Current Rating. IEC 60947-4-1 and 60947-6-2 refer to these ratings as Ir and Icr respectively. T echn ic al de ta ils Standard Fault Short Circuit Current Rating (Derived from UL 508): The minimum short circuit current, based on horsepower rating, that a starter must be capable of withstanding in accordance with the applicable pass/fail criteria. Denoted as Ir by IEC 60947-4-1 and Icr by IEC 60947-6-2. 160 Manufacturers may also specify short circuit ratings exceeding the minimum ratings required by standards. UL and CSA refer to these as the High-Available Fault Short Circuit Current Rating. IEC 60947-4-1 and 60947-6-2 refer to these ratings as Iq and Ics respectively. High-Available Fault Short Circuit Current Rating (Derived from UL 508): The short circuit current rating specified by the manufacturer of a motor controller, which is greater than the standard short circuit current rating. The motor controller is capable of withstanding the high-available short circuit current in accordance with the applicable pass/fail criteria. Denoted as Iq by IEC 60947-4-1 and Ics by IEC 60947-6-2. Following is a summary of short circuit testing pass/fail criteria applicable to magnetically operated direct-on-line contactors and starters. Standards should be referenced for exact wording and all specific pass/fail criteria. UL and IEC criteria are summarized for standard and high-available short circuit currents. CSA criteria are summarized for high-available short circuit currents. Technical details PG03407001U - June 2006 Defining Pass/Fail Criteria: UL 508/CSA C22.2 No. 14 and IEC 60947-4-1 UL and CSA Fault Current Enclosure Terminals and Conductors Contactor/Starter Housing Short Circuit Protective Device (SCPD) Contactor/Starter Contacts Overload Relay Contactor/Starter Operation Type 2 Fault current is successfully interrupted and no arcing to enclosure or proximity barrier is indicated by an open ground wire or fuselink. No substantial damage to the enclosure. It may be deformed but it must be possible to open the door. Live parts shall not be accessible. No damage to conductors or terminals. Conductors must not be separated from the terminals. No cracking or breaking of the contactor/starter housing that impairs the integrity of the mounting of live parts. The circuit breaker or switch must be capable of being operated manually. SCPD is not separated from its mounting means. Fuses must not rupture. Welding and complete Welding acceptable. Welding acceptable provided disintegration acceptable. contacts can be easily separated. Electronic overload relays must be Damage acceptable. No damage, tripping operable; tripping characteristics characteristics must be verified. must be verified (UL). Mechanical overload relays may be damaged, if so, device must include markings indicating that (UL). May be inoperable. May be inoperable. Must be operable, verified by 10 operations after short circuit test. No discharge of parts from No discharge of parts from No discharge of parts from enclosure. No risk of fire. enclosure. Must pass 2X rated enclosure. Must pass 2X rated voltage, 1000V minimum dielectric voltage, 1000V minimum dielectric test. test. T echn ic al de ta ils Other IEC 60947-4-1 Type 1 PG03407001U - June 2006 Technical details 161 What feeder circuit devices do you need for Type 2? Achieving Type 2 is straightforward when using the following selection tables. Follow these steps to ensure that Type 2 coordination is in place: Step 1: Determine the motor kW (single or three phase) or full load motor current from the motor nameplate. Step 2: Verify the motor full load amps are less than or equal to the operational current (Ie) listed next to the kW in the table. Step 3: Manual Motor Controllers (MMC): Read across the tables horizontally for catalogue numbers of the Manual Motor Protector (MMP) and contactor (customer assembly) or pre-assembled Manual Motor Controller. Note: For certain kW ratings at 480V and 600V, a current limiter must be used to achieve the maximum Type 2 rating (shown in the following tables). Customers can either order the MMP and Current Limit Contactors or an assembled MMC and current limiter. Circuit breaker combination controllers: Read across the tables horizontally to determine the catalogue numbers of the circuit breaker to be used in conjunction with the contactor and overload relay listed (customer assembly) or the pre-assembled motor starter. Fused combination controllers: Read across the tables horizontally to determine what amperage size fuse (customer to specify brand) and the catalogue numbers of the contactor and overload relay or the pre-assembled motor starter. Manual Motor Controller Combinations 400/415V Type 2 Coordination, MMC T echn ic al de ta ils P (kW) 162 Ie (A) Iq (kA) MMP Eaton list number Contactor Eaton list number 2) MMC Eaton list number 2) 0.06 0.21 50.00 (150.00) 1) XTPRP25BC1 XTCE007B10_ XTSCP25BB_ 0.09 0.31 50.00 (150.00) 1) XTPRP40BC1 XTCE007B10_ XTSCP40BB_ 0.12 0.41 50.00 (150.00) 1) XTPRP63BC1 XTCE007B10_ XTSCP63BB_ 0.18 0.60 50.00 (150.00) 1) XTPRP63BC1 XTCE007B10_ XTSCP63BB_ 0.25 0.80 50.00 (150.00) 1) XTPR001BC1 XTCE007B10_ XTSC001BB_ 0.37 1.10 50.00 (150.00) 1) XTPR1P6BC1 XTCE007B10_ XTSC1P6BB_ 0.55 1.50 50.00 (150.00) 1) XTPR1P6BC1 XTCE007B10_ XTSC1P6BB_ 0.75 1.90 50.00 (150.00) 1) XTPR2P5BC1 XTCE007B10_ XTSC2P5BB_ 1.10 2.60 50.00 (150.00) 1) XTPR004BC1 XTCE007B10_ XTSC004BB_ 1.50 3.60 50.00 (150.00) 1) XTPR004BC1 XTCE007B10_ XTSC004BB_ 2.20 5.00 50.00 (150.00) 1) XTPR6P3BC1 XTCE007B10_ XTSC6P3BB_ 3.00 6.60 50.00 (150.00) 1) XTPR010BC1 XTCE018C10_ XTSC010BC_ 4.00 8.50 XTCE018C10_ XTSC010BC_ 11.30 16.00 21.70 29.30 50.00 (150.00) 1) 50.00 50.00 50.00 50.00 XTPR010BC1 5.50 7.50 11.00 15.00 XTPR012BC1 XTPR016BC1 XTPR025BC1 XTPR032BC1 XTCE018C10_ XTCE018C10_ XTCE025C10_ XTCE032C10_ XTSC012BC_ XTSC016BC_ XTSC025BC_ XTSC032BC_ 5.50 7.50 11.00 15.00 18.50 22.00 30.00 34.00 11.30 16.00 21.70 29.30 36.00 41.00 55.00 63.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 XTPR016DC1 XTPR016DC1 XTPR025DC1 XTPR032DC1 XTPR040DC1 XTPR050DC1 XTPR058DC1 XTPR063DC1 XTCE018C10_ XTCE018C10_ XTCE025C10_ XTCE032C10_ XTCE040D00_ XTCE050D00_ XTCE065D00_ XTCE065D00_ XTSC016DC_ XTSC016DC_ XTSC025DC_ XTSC032DC_ XTSC040DD_ XTSC050DD_ XTSC058DD_ XTSC063DD_ 1) Values in parentheses ( 2) ) are for Type 1 Coordination. Underscore (_) indicates coil suffix required. Technical details PG03407001U - June 2006 400/415V Contactor and Overload Relay (Motor Starter) with Fused Disconnect P (kW) Ie (A) Iq (kA) Fuses Class gG/gL Contactor Eaton list number1) Overload Relay Eaton list number Assembled Starter Eaton list number 1) XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE009B10_ XTCE018C10_ XTCE018C10_ XTCE025C10_ XTCE032C10_ XTCE040D00_ XTCE050D00_ XTCE065D00_ XTOBP60BC1 XTOB001BC1 XTOB001BC1 XTOB1P6BC1 XTOB1P6BC1 XTOB2P4BC1 XTOB004BC1 XTOB004BC1 XTOB006BC1 XTOB010BC1 XTOB010BC1 XTOB016CC1 XTOB016CC1 XTOB024CC1 XTOB032CC1 XTOB040DC1 XTOB057DC1 XTOB057DC1 XTAE007B10_P60 XTAE007B10_001 XTAE007B10_001 XTAE007B10_1P6 XTAE007B10_1P6 XTAE007B10_2P4 XTAE007B10_004 XTAE007B10_004 XTAE007B10_006 XTAE007B10_010 XTAE009B10_010 XTAE018C10_016 XTAE018C10_016 XTAE032C10_024 XTAE032C10_032 XTAE040D00_040 XTAE065D00_057 XTAE065D00_057 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 15.00 18.50 22.00 30.00 37.00 0.41 0.60 0.80 1.10 1.50 1.90 2.60 3.60 5.00 6.60 8.50 11.30 16.00 21.70 29.30 36.00 41.00 55.00 68.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 2 2 4 4 4 6 6 6 10 16 20 25 32 40 63 63 80 100 125 XTCE080F00_ 2) XTOB070GC1 2) XTAE080F00_070 2) 45.00 81.00 100.00 160 XTCE095F00_ 2) 2) XTAE095F00_100 2) 55.00 99.00 100.00 200 XTCE115G00_ 2) XTOB100GC1 2) XTAE115G00_100 2) 75.00 134.00 100.00 200 90.00 110.00 132.00 161.00 196.00 231.00 100.00 100.00 100.00 250 315 400 XTCE150G00_ 2) XTCE185L22_ XTCE225L22_ XTCE250L22_ XTOB150GC1 2) XTOB220LC1 XTOB220LC1 XTOB250LC1 XTAE150G00_150 2) XTAE185L22_220 XTAE225L22_220 XTAE250L22_250 XTOB100GC1 1) Underscore (_) indicates coil code required. 2) Contactor frames F and G to be released in June 2006. Contact Eaton for final Type 2 combinations. P (kW) Ie (A) Iq (kA) Fuses Class gG/gL Contactor Eaton list number1) Overload Relay Eaton list number Assembled Starter Eaton list number 1) 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 15.00 18.50 22.00 30.00 37.00 45.00 55.00 75.00 90.00 110.00 132.00 160.00 0.33 0.48 0.70 0.90 1.20 1.50 2.10 2.90 4.00 5.30 6.80 9.00 12.10 17.40 23.40 28.90 33.00 44.00 54.00 65.00 79.00 107.00 129.00 157.00 184.00 224.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 2 2 2 2 4 4 6 6 10 16 16 20 25 32 50 50 63 80 100 125 160 200 200 250 250 315 XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE009B10_ XTCE009B10_ XTCE012B10_ XTCE018C10_ XTCE025C10_ XTCE040D00_ XTCE040D00_ XTCE050D00_ XTCE065D00_ XTCE080F00_ 2) XTCE095F00_ 2) XTCE115G00_ 2) XTCE185L22_ XTCE185L22_ XTCE185L22_ XTCE185L22_ XTCE225L22_ XTOBP40BC1 XTOBP60BC1 XTOB001BC1 XTOB001BC1 XTOB1P6BC1 XTOB1P6BC1 XTOB2P4BC1 XTOB004BC1 XTOB006BC1 XTOB006BC1 XTOB010BC1 XTOB010BC1 XTOB016CC1 XTOB024CC1 XTOB024DC1 XTOB040DC1 XTOB040DC1 XTOB057DC1 XTOB070GC1 2) XTOB070GC1 2) XTOB100GC1 2) XTOB125LC1 XTOB125LC1 XTOB160LC1 XTOB220LC1 XTOB250LC1 XTAE007B10_P40 XTAE007B10_P60 XTAE007B10_001 XTAE007B10_001 XTAE007B10_1P6 XTAE007B10_1P6 XTAE007B10_2P4 XTAE007B10_004 XTAE007B10_006 XTAE009B10_006 XTAE009B10_010 XTAE012B10_010 XTAE018C10_016 XTAE025C10_024 XTAE040D00_024 XTAE040D00_040 XTAE050D00_040 XTAE065D00_057 XTAE080F00_070 2) XTAE095F00_070 2) XTAE115G00_100 2) XTAE185L22_125 XTAE185L22_125 XTAE185L22_160 XTAE185L22_220 XTAE225L22_250 T echn ic al de ta ils 500V Type 2 Coordination, Contactor and Overload Relay (Motor Starter) with Fused Disconnect 1) Underscore (_) indicates coil code required. 2) Contactor frames F and G to be released in June 2006. Contact Eaton for final Type 2 combinations. PG03407001U - June 2006 Technical details 163 690V Type 2 Coordination, Contactor and Overload Relay (Motor Starter) with Fused Disconnect P (kW) Ie (A) Iq (kA) Fuses Class gG/gL Contactor Eaton list number 1) Overload Relay Eaton list number Assembled Starter Eaton list number1) 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 15.00 18.50 22.00 30.00 37.00 45.00 55.00 75.00 90.00 110.00 132.00 160.00 0.24 0.35 0.50 0.70 0.90 1.10 1.50 2.10 2.90 3.80 4.90 6.50 8.80 12.60 17.00 20.90 23.80 32.00 39.00 47.00 58.00 78.00 93.00 114.00 134.00 162.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 1 2 2 2 4 4 4 6 10 10 16 16 20 25 32 32 50 63 80 80 100 160 160 200 250 250 XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE007B10_ XTCE009B10_ XTCE012B10_ XTCE018C10_ XTCE025C10_ XTCE032C10_ XTCE040D00_ XTCE040D00_ XTCE065D00_ XTCE080F00_ 2) XTCE080F00_ 2) XTCE080F00_ 2) XTCE095F00_ 2) XTCE115G00_ 2) XTCE185L22_ XTCE185L22_ XTCE185L22_ XTOBP40BC1 XTOBP40BC1 XTOBP60BC1 XTOB001BC1 XTOB001BC1 XTOB1P6BC1 XTOB1P6BC1 XTOB2P4BC1 XTOB004BC1 XTOB004BC1 XTOB006BC1 XTOB010BC1 XTOB010CC1 XTOB016CC1 XTOB024CC1 XTOB024DC1 XTOB040DC1 XTOB040DC1 XTOB050GC1 2) XTOB050GC1 2) XTOB070GC1 2) XTOB100GC1 2) XTOB100GC1 2) XTOB125LC1 XTOB160LC1 XTOB220LC1 XTAE007B10_P40 XTAE007B10_P40 XTAE007B10_P60 XTAE007B10_001 XTAE007B10_001 XTAE007B10_1P6 XTAE007B10_1P6 XTAE007B10_2P4 XTAE007B10_004 XTAE007B10_004 XTAE009B10_006 XTAE012B10_010 XTAE018C10_010 XTAE025C10_016 XTAE032C10_024 XTAE040D00_024 XTAE040D00_040 XTAE065D00_040 XTAE080F00_050 2) XTAE080F00_050 2) XTAE080F00_070 2) XTAE095F00_100 2) XTAE115G00_100 2) XTAE185L22_125 XTAE185L22_160 XTAE185L22_220 1) Underscore (_) indicates coil code required. Contactor frames F and G to be released in June 2006. Contact Eaton Corporation for final Type 2 combinations. T echn ic al de ta ils 2) 164 Technical details PG03407001U - June 2006 400/415V Contactor and Overload Relay (Motor Starter) with Circuit Breaker 1) P (kW) Ie (A) Iq (kA) Circuit Breaker Contactor Eaton list number2) Overload Relay Eaton list number Assembled Starter Eaton list number2) 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 11.00 15.00 18.50 22.00 30.00 37.00 45.00 55.00 75.00 90.00 110.00 132.00 160.00 0.41 0.60 0.80 1.10 1.50 1.90 2.60 3.60 5.00 6.60 8.50 11.30 16.00 21.70 29.30 36.00 41.00 55.00 68.00 81.00 99.00 134.00 161.00 196.00 231.00 279.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 15.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 50.00 HMCPE003A0C HMCPE003A0C HMCPE003A0C HMCPE003A0C HMCPE003A0C HMCPE007C0C HMCPE007C0C HMCPE007C0C HMCPE007C0C HMCPE015E0C HMCPE015E0C HMCPE015E0C HMCPE030H1C HMCPE030H1C HMCPE050K2C HMCPE100R3C HMCPE100R3C HMCPE100R3C HMCPJ250D5L HMCPJ250F5L HMCPJ250G5L HMCPJ250G5L HMCPJ250W5L HMCPL600N HMCPL600R HMCPL600X XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE018C10_ XTCE025C10_ XTCE032C10_ XTCE040D00_ XTCE050D00_ XTCE065D00_ XTCE080F00_ 3) XTCE095F00_ 3) XTCE115G00_ 3) XTCE150G00_ 3) XTCE185L22_ XTCE300M22_ XTCE300M22_ XTCE300M22_ XTOBP60CC1 XTOB001CC1 XTOB001CC1 XTOB1P6CC1 XTOB1P6CC1 XTOB2P4CC1 XTOB004CC1 XTOB004CC1 XTOB006CC1 XTOB010CC1 XTOB010CC1 XTOB016CC1 XTOB024CC1 XTOB024CC1 XTOB032CC1 XTOB040DC1 XTOB057DC1 XTOB065DC1 XTOB070GC1 3) XTOB100GC1 3) XTOB125GC1 3) XTOB150GC1 3) XTOB220LC1 XTOT240C3S XTOT290C3S XTOT400C3S XTAE018C10_P60 XTAE018C10_001 XTAE018C10_001 XTAE018C10_1P6 XTAE018C10_1P6 XTAE018C10_2P4 XTAE018C10_004 XTAE018C10_004 XTAE018C10_006 XTAE018C10_010 XTAE018C10_010 XTAE018C10_016 XTAE032C10_024 XTAE032C10_024 XTAE032C10_032 XTAE040D00_040 XTAE065D00_057 XTAE065D00_065 XTAE080F00_070 3) XTAE095F00_100 3) XTAE115G00_125 3) XTAE150G00_150 3) XTAE185L22_220 XTAE300M22_240 XTAE300M22_290 XTAE300M22_400 1) All Type 2 circuit breaker combinations are pending KEMA certification. 3) Underscore (_) indicates coil code required. Contactor frames F and G to be released in June 2006. Contact Eaton for final Type 2 combinations. T echn ic al de ta ils 2) PG03407001U - June 2006 Technical details 165 Master Coil Suffix Selection Table Frame Size Coil Voltage 50Hz 60Hz DC Suffix Code2) 120V 220V 12V 24V 48V A B F T C D E G H L N P R U W Y AD 1) BD 1) RD 1) TD 1) WD 1) Frame A - B 110V 220V 230V 24V 415V 550V 190V 240V 380V 400V 12V 24V 42V 48V 120V 240V 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V Frame C - F 110V 220V 230V 24V 415V 550V 190V 240V 380V 400V 12V 24V 42V 48V 120V 240V A B F T C D E G H L N P R U W Y 24V 480V 600V 208V 220V 277V 440V 380V 12V 48V 60 Hz 110 - 130V AD 1) 200 - 240V BD 1) 12 - 14V RD 1) 24 - 27V TD 1) 48 - 60V WD 1) Frame G T echn ic al de ta ils 100 - 120V 190 - 240V 24V 480 - 500V 380 - 440V 42 - 48V A B T C L W 24 - 27V TD 1) 110 - 130V AD 1) 200 - 240V BD 1) 48 - 60V WD 1) 110 - 250V A C 48 - 110V Y 1) 24 - 48V TD 1) B Frame L - N 110 - 250V 250 - 500V 48 - 110V Frame P - R 1) 2) 166 100 - 120V 190 - 240V 24V 480 - 500V 380 - 440V 42 - 48V 220 - 250V 110 - 250V 250 - 500V 48 - 110V 220 - 250V 250 - 500V With DC operation: Integrated diode-resistor combination, coil rating 2.6W. Add suffix in place ofunderscore (_) to Eaton List number. Technical details PG03407001U - June 2006 XTAE007B01_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE007B10_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE009B01_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE009B10_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE012B01_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE012B10_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE015B01_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE015B10_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE018C01_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE018C10_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE025C01_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE025C10_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE032C01_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE032C10_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE040D00_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE050D00_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE065D00_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 XTAE080F00_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE095F00_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE115G00_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE150G00_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE185L22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE225L22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE250L22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE300M22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE400M22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE500M22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE580N22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAE650N22_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XTAR007B21_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR009B21_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR012B21_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR018C21_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR025C21_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR032C21_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR040D11_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR050D11_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR065D11_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR115G11_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTAR150G11_ _ . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 XTCE007B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE007B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE007B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE007B10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE007B10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE009B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE009B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE009B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE009B10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE009B10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE012B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE012B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE012B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE012B10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE012B10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE015B01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE015B10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE018C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE018C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE018C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE018C10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE018C10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE025C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE025C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE025C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE025C10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE025C10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE032C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 XTCE032C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE032C01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE032C10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 PG03407001U - June 2006 XTCE032C10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCE040D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE040D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE040D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE040D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE040D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE040D10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE050D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE050D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE050D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE050D10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE065D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE065D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE065D00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE065D10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE080F00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE080F00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE080F00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE080F00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE080F10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE095F00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE095F00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE095F10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE115G00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE115G00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE115G00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE115G10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE150G00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE150G00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE150G00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE150G10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCE185L00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE185L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE185L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE185L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE185L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE225L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE225L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE225L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE250L00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE250L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 XTCE250L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE250L22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE300M00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE300M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCE300M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE300M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE400M00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE400M00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE400M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCE400M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE400M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE500M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCE500M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE500M22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCE580N00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE580N00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE580N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCE580N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE580N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE650N00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE650N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCE650N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE650N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE750N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCE750N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE750N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE820N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCE820N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCE820N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCEC10N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCEC10N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCEC10N22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTCEC14P22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCEC20R22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 XTCERENARC185 . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENARC225 . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENARC250 . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENARC300 . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENARC400 . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENARC500 . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILCA . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCAD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCB . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCBD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCC . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCD . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCE . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCF . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCG . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCH . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCL . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCN . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCP . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCR . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCRD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCT . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCTD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCU . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCW . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCWD . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILCY . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDA . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDAD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDB . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDBD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDC . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDD . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDE . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDF . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDG . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDH . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDL . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDN . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDP . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDR . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDRD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDT . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDTD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDU . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDW . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDWD . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILDY . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFA . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFAD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFB . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFBD . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFC . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFD . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFE . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFF . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFG . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFH . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFL . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFN . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFP . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFR . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFT . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFTD . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFU . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFW . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILFWD . . . . . . . . . . . . . . . . . . . . . . . . . .33 Eaton list number index Eaton list number index Eaton list number index 167 Eaton list number index Eaton list number index 168 XTCERENCOILFY . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 XTCERENCOILGA . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGAD . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGB . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGBD . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGC . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGL . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGT . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGTD . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGW . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILGWD . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILLA . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILLC . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILLTD . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILLY . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILMA . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILMC . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILMTD . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILMY . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILNA . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILNC . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCOILNY . . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCONTACTD . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCONTACTL . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENCONTACTM . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENVACT580 . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENVACT650 . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENVACT750 . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCERENVACT820 . . . . . . . . . . . . . . . . . . . . . . . . . .34 XTCEX4P35D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 XTCEX4P35D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 XTCEX4P35D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 XTCEXCLK3B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXCLK4B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXCLK5B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXCNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXCNG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXFAC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXFAC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXFAC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAC40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFAC40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFACC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFACC04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFACC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFACC13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFACC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Eaton list number index XTCEXFACC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFACC31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFACC40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFACC40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFAG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFAG22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFAGC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFALC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFALC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFALCC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFALCC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFATC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFATC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFATC20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFATC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFBG02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBG04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXFBG11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXFBG13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBG20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBG22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBG22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXFBG22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXFBG31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBG40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBGC04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBGC13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBGC31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBGC32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBGC40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBLG22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFBLGC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXFCC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFCC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFCCC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFCCC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFCLC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFCLCC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXFDC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXFDCC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 XTCEXITB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXLBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXMLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXMLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXMLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXMLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXMLG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXMLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXMLN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXP75D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 XTCEXP75D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 XTCEXP75D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 XTCEXPBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXPBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXPLKB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXPLKC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXPLKD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXPLKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXPLKL185 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXRBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXRBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXRLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXRLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSBLN11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXSBN11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXSBNC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXSCC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXSCN11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXSCNC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 XTCEXSDB400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDB500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDBD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXSDLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXSDLB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXSDLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 XTCEXSDLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXSDLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXSDLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTCEXSDLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXSDLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXSDLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXSDLF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXSDLF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXSDLG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXSDLG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTCEXSDLL250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXSDLL250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXSDLL250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXSDLM400 . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXSDLM400 . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXSDLM400 . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTCEXTCWG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 XTCEXTED100C11A . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED100C11B . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED100C11T . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED10C11A . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED10C11B . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED10C11T . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED1C11A . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED1C11B . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTED1C11T . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTEEC11T . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTEEC11T . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTEEC11T . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTESHRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTEYC20A . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTEYC20B . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTEYC20T . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 XTCEXTFB650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXTFB820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXTL500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXTL650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXTL820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXTLA225 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXTLA400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 XTCEXTS400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 XTCEXTS500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 XTCEXTS650 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 XTCEXTS820 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 XTCEXVIBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVIBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVIBW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVICA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVICB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVICW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVIGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVIGB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 PG03407001U - June 2006 XTCEXVIGW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 XTCEXVSBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSBW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSFW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSLBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSLBW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSLCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSLCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSLFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCEXVSLFW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 XTCF020B00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 XTCR007B21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR009B21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR012B21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR018C21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR025C21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR032C21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR040D11_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR050D11_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR065D11_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 XTCR080F11_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 XTCR095F11_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 XTCR115G11_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 XTCR150G11_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 XTMC6A01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMC6A10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMC9A01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMC9A01_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 XTMC9A10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 XTMC9A10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 XTMC9A10_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMCC6A0_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMCC6A1_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMCC9A0_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMCC9A1_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMCXCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 XTMCXFA02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFA04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFA11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFA13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFA20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFA22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFA31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFA40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFA40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFAC04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFAC04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFAC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFAC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFAC13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFAC13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFAC31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFAC31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFAC40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFAC40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 PG03407001U - June 2006 XTMCXFAL11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFAL11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFAL22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFAL22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 XTMCXFC02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 XTMCXFC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFCC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFCLC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMCXFCLC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFD11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXFDC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTMCXML . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 XTMCXPLK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 XTMCXRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 XTMCXRSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXRSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXRSCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXRSCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXRSCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXRSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXSDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXSDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXSHROUD . . . . . . . . . . . . . . . . . . . . . . . . . . .17 XTMCXVSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXVSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXVSCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXVSCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXVSCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXVSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMCXVSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 XTMF9A00_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMR6A21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMR9A21_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 XTMT6A30S11B . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 XTMT6A60H11B . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 XTMT6A60H70B . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 XTMXCFAC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 XTMXCFAC22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 XTOB 001 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 001 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 004 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 004 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 006 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 006 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 010 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 010 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 010 DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 012 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 016 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 016 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 016 DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 024 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 024 DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 032 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 035 GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 035 GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 040 DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 050 GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 050 GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 057 DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 065 DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 070 GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 070 GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 070 LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 100 GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 100 GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 100 LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 125 GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 125 GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 125 LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 150 GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 150 GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 160 LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 1P6 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 1P6 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB 220 LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 250 LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOB 2P4 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB 2P4 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB P16 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB P16 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB P24 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB P24 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB P40 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB P40 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB P60 BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 XTOB P60 CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 XTOB...BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTOB...BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTOB...BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTOB...CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTOB...CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTOB...CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTOB...DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTOB...DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTOB...DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTOB...FC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTOB...FC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTOB...GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTOB...GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTOB...LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTOB...LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTOB...LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTOB001BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB001CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB004BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB004CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB006BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB006CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB010BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB010CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB010DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB012BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB016BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB016CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB016DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB024CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB024DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB032CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB035GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB035GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB040DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB050GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB050GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB057DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB065DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB070GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB070GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB070LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB100GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB100GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB100LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB125GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB125GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB125LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB150GC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB150GC1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB160LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB1P6BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB1P6CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Eaton list number index Eaton list number index Eaton list number index 169 Eaton list number index Eaton list number index 170 XTOB220LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB250LC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOB2P4BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOB2P4CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP16BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP16CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP24BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP24CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP40BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP40CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP60BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBP60CC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 XTOBXDINC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 XTOBXDIND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 XTOBXTSCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 XTOBXTSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 XTOM001AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOM004AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOM006AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOM009AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOM012AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOM1P6AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOM2P4AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOMP16AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOMP24AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOMP40AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOMP60AC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 XTOT 063 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT 090 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT 125 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT 160 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT 240 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT 290 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT 400 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT 540 C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTOT...C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTOT063C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOT090C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOT125C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOT160C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOT240C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOT290C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOT400C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTOT540C3S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 XTPAXCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXCLKA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKA2D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKA3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKA3D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKA4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKA4D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKA5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKB2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKB3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKB4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKB5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKC2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXCLKC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXENCF40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 XTPAXENCF55B . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 XTPAXENCF55RY . . . . . . . . . . . . . . . . . . . . . . . . . . .63 XTPAXENCS40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCS41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCS55B . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Eaton list number index XTPAXENCS55RY . . . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCS65B . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCS65RY . . . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCSD65B . . . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCSD65RY . . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCSEM55B . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCSEM55RY . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCSEM65B . . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXENCSEM65RY . . . . . . . . . . . . . . . . . . . . . . . .62 XTPAXFA10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXFA11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXFAC01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXFAC10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXFAEM20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 XTPAXILGB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILGC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILRB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILRN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILWC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXILWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPAXMCG20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXMCG25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXMCG32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXMCG32G . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXMDG20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXMDG25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXMDG32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 XTPAXPL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 XTPAXPL2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 XTPAXPL3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 XTPAXRHM165B . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXRHM265RY . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXRHM365B . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXSA11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXSA12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXSA21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXSAC11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 XTPAXSATR02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 XTPAXSATR20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 XTPAXSR110V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR110VDC . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR120V60H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR125VDC . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR208V60H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR220V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR220VDC . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR230V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR240V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR240V60H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR24V50H . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR24VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR250VDC . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR380V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR400V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR415V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR440V60H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR480V60H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR48V50H . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR48VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSR60VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSRC230V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSRC24VDC . . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXSW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXTEA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 XTPAXTPCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXTPCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXTPCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXTPCPB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXTPCRB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXTPCRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXTPCRD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXTPCRPB . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 XTPAXUTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXUTSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 XTPAXUVR110V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR120V60H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR208V60H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR220V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR230V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR240V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR240V60H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR24V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR24V60H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR380V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR400V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR415V50H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR440V60H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR480V60H . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR48V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVR60V50H . . . . . . . . . . . . . . . . . . . . . . . . . .58 XTPAXUVRC230V50H . . . . . . . . . . . . . . . . . . . . . . . .58 XTPB001BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB004BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB010BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB012BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB016BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB020BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB025BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB1P6BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB2P5BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPB6P3BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPBP16BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPBP25BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPBP40BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPBP63BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 XTPBXENCF40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCF55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCFEK55 . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCFES55 . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCFLE55 . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCFLO55 . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCS40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCS65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCSEK65 . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCSES65 . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCSLE65 . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXENCSLO65 . . . . . . . . . . . . . . . . . . . . . . . . . . .61 XTPBXFAEM20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 XTPM001B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM004B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM010B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM012B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM016B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM020B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM025B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM032B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM1P6B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM2P5B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPM6P3B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPMP16B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPMP25B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPMP40B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPMP63B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 XTPR001BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR004BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR010BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR012BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 PG03407001U - June 2006 Eaton list number index PG03407001U - June 2006 XTSC012BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSC016BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC016DC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC020BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC025BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC025DC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC032BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC032DC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC040DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC050DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC058DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC063DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 XTSC1P6BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSC2P5BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSC6P3BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSCP25BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSCP40BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSCP63BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSR001BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR004BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR010BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR012BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR016BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR016DC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR020BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR025BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR025DC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR032BC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR032DC_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR040DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR050DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR058DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR063DD_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR1P6BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR2P5BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSR6P3BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSRP25BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSRP40BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTSRP63BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 XTTR6A60S51B . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Eaton list number index XTPR016BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR016DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR020BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR025BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR025DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR032BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR032DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR040DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR050DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR058DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR063DC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR1P6BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR2P5BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPR6P3BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPRC001BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC001BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC004BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC004BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC010BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC010BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC012BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC012BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC016BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC016BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC020BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC025BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC1P6BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC1P6BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC2P5BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC2P5BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRC6P3BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRC6P3BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRCP16BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRCP16BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRCP25BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRCP25BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRCP40BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRCP40BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRCP63BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRCP63BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 XTPRP16BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPRP25BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPRP40BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPRP63BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 XTPRSC001BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSC004BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSC010BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSC012BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSC016BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSC1P6BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSC2P5BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSC6P3BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSCP16BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSCP25BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSCP40BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTPRSCP63BC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 XTRE10B22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRE10B31_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRE10B40_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTREC10B22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTREC10B31_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTREC10B40_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRM10A22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRM10A31_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRM10A40_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRMC10A22_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRMC10A31_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTRMC10A40_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 XTSC001BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSC004BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 XTSC010BB_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 Eaton list number index 171 In the electrical industry, Eaton is a global leader in electrical control, power distribution, and industrial automation products and services. Through advanced product development, world class manufacturing methods and global engineering services and support, Eaton provides customer-driven solutions under brand names such as Cutler-Hammer(R), Powerware, Durant(R), Heinemann(R), Holec(R), and MEM(R), which globally serve the changing needs of the industrial, utility, light commercial, residential, and OEM markets. For more information, visit www.eatonelectrical.com. Eaton Corporation is a diversified industrial manufacturer with 2005 sales of $11.1 billion. Eaton is a global leader in electrical systems and components for power quality, distribution and control; fluid power systems and services for industrial, mobile and aircraft equipment; intelligent truck drivetrain systems for safety and fuel economy; and automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety. Eaton has 59,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com. Eaton Electric Limited Eaton Electric BV Reddings Lane PO Box 23 Birmingham B11 3EZ 7550 AA Hengelo United Kingdom The Netherlands Customer Support Centre Customer Support Centre Tel: +44 (0)8700 545 333 Tel: +31 (0)74 246 7066 Fax: +44 (0)8700 540 333 Fax: +31 (0)74 246 7070 email: ukcommorders@eaton.com email: c-heuropesupport@eaton.com (c) 2006 Eaton Electric Limited All rights reserved Printed in UK Form No PG03407001U June 2006