4
RY SERIES
n SPECIFICATIONS
High 500 mW High Continuous
Sensitive Type Dielectric 2 A Type (MBB)
Item Type Strength Type
RY-( ) W-K RY-( ) WZ-K RY-( ) WF-K RY-( ) WFZ-K RY-( ) D-K
Contact Arrangement 2 form C (DPDT)
2 Form D (2 MBB)
Material Gold overlay silver-palladium Gold overlay
Gold overlay
silver-nickel
silver-palladium
Style Bifurcated (cross bar) Single
Resistance(initial) Maximum100mΩ(at1A6VDC)
MaximumCarryingCurrent 1.25A 2A 0.6A
Rating (resistive) 1 A 24 VD
1 A 24 VDC 2 A 30 VDC 0.15 A 48 VDC
0.5 A 120 VAC
0.25 A 120 VAC 0.5 A 125 VAC 0.3 A 120 VAC
MaximumSwitchingPower 60VA/24W 30VA/24W 62.5VA/60W36VA/7.2W
MaximumSwitchingVoltage 120VAC,60VDC
125 VAC, 150 VDC 120 VAC, 60 VDC
MaximumSwitchingCurrent 1A 2A 0.6A
Minimum Switching Load*1 0.01 mA 10 mVDC
0.1 mA 10 mVDC
Capacitance(at10MHz) Approx.0.9pF(betweenopencontacts)1.4pF(adjacentcontacts)
Approx.1.9pF(betweencoilandcontacts)
Coil Nominal Power (at 20°C) 150 to 300 mW 500 to 580 mW 450 to 460 mW 500 to 580 mW 450 to 480 mW
Operate Power (at 20°C) 75 to 140 mW 125 to 145 mW 200 to 210 mW 200 to 324 mW 200 to 210 mW
Operating Temperature (No frost)
–30°Cto+90
°C–30°Cto+60°C(refer to the CHARACTERISTIC DATA)
–30°Cto+70°C
(*+80ºC) (*2+65ºC)
TimeValue Operate(atnominalvoltage) Maximum6ms
Release(atnominalvoltage) Maximum3ms
Life Mechanical
2 × 107 ops. min.
1 × 107 operations minimum
1 × 106 ops. min.
Electrical (at contact rating)
2 × 105 ops. min. (0.5 A 120 VAC)
5 × 105 ops. min. 1 × 105 ops. min. 2 × 105 opsmin.
5 × 105 ops. min. ( 1 A 24 VD C)
(0.25 A 120 VAC (2 A 30 VDC) (0.3 A 120 VAC)
1 A 24 VDC 5 × 105 ops. min.
(0.15 A 48 VDC)
Other Vibration Misoperation 10 to 55 Hz (double amplitude of 1.5 mm)
Resistance Endurance 10 to 55 Hz (double amplitude of 4.5 mm)
ShockMisoperation 100m/s2 (11±1 ms)
ResistanceEndurance 1,000m/s2 ( 6±1 ms)
Weight Approximately5g
*1Minimumswitchingloadsmentionedabovearereferencevalues.Pleaseperformtheconrmationtestwiththeactualload
beforeproductionsincereferencevaluesmayvaryaccordingtoswitchingfrequencies,environmentalconditionsandex-
pected reliability levels.
*2 48VDC type
Item Sensitive 500mW High Isolation 2A MBB
Isolation (initial) Minimum1,000MΩ(at500VDC)
Dielectric
Strength
open contact 500VAC 1 min., 1,000VAC 1 min., 500VAC 1 min.,
coilandcontact/
adjacentcontacts
1,000VAC 1 min.,
Surge Voltage 1500V(coil-contact)(10/160µsstandardwave)
n INSULATION