SCP1000 DEMO KIT
User Manual
All accessible SCP1000 registers are listed in Table 5 below, please refer to the document
"SCP1000 Product Family Specification 8260800" for more detailed information on SCP1000
registers. The register address is always in hex format unless otherwise noted.
Table 5. List of SCP1000 direct and indirect access registers and EEPROM registers.
Address
SPI TWI Name Description Mode
(R, W, RW)
Register
access Width
[bits]
00 REVID ASIC revision number R Direct 8
01 DATAWR Indirect register access data RW Direct 8
02 ADDPTR Indirect register access pointer RW Direct 8
03 OPERATION Operation register RW Direct 8
04 OPSTATUS Operation status R
Direct 8
06 RSTR ASIC software reset W Direct 8
07 STATUS ASIC top-level status R Direct 8
1F 7F DATARD8 Pressure output data (MSB) or
8 bit data read from EEPROM R Direct 8
20 80 DATARD16 Pressure output data (LSB) or
8-bit data read from indirect register R Direct 16
21 81 TEMPOUT 14-bit temperature output data R Direct 16
00 CFG Configuration register RW Indirect 8
05 TWIADD TWI address W Indirect 8
09 CFG2 MISO configuration RW Indirect 8
2D MODTEST2 Noise level configuration W Indirect 8
29 USERDATA1
User data RW EEPROM 8
2A USERDATA2 User data RW EEPROM 8
2B USERDATA3
User data RW EEPROM 8
2C USERDATA4 User data RW EEPROM 8
Register address in hex format.
RW – Read / Write register, R – Read only register.
6 Using two SCP1000 demo kits simultaneously
In some applications, such as air conditioning controlling or air flow measurements, differential
pressure measurement is required. To support these kinds of applications two (or even more)
SCP1000 demo kits can be used simultaneously on one PC.
In order to use two SCP1000 demo kits simultaneously follow the steps below:
1. Install the GUI software and USB driver as instructed above (see section 2).
2. Connect the 1st SCP1000 demo kit to PC.
3. Start the GUI software.
4. When the 1st SCP1000 demo kit and it's GUI software is running, connect the 2nd SCP1000
demo kit to PC.
5. Install the USB driver if required (the USB driver has to be installed separately for each
USB port, see inst ructions in section 2).
6. Find the location of the SCP1000 demo kit GUI software exe-file (the default installation
path is C:\Program Files\SCP1000-USB-DEMO-VER.2.5).
7. Copy the file "SCP1000-USB-DEMO-VER.2.5.exe" to other name (for example
"Copy of SCP1000-USB-DEMO-VER.2.5.exe").
8. Start the GUI software for the 2nd SCP1000 demo kit by running the
"Copy of SCP1000-USB-DEMO-VER.2.5.exe".
When both demo kits are connected to one PC, the SCP1000 data can be logged to separate files
as instructed in section 4.1.3. If the both demo kits are used for data logging purposes, the data
can be synchronized with the time stamp in the result file (time is from the PC's system clock). The
Windows HyperTerminal can also be used with two SCP1000 demo kits (open own HyperTerminal
connection for each demo kit).
Please notice, that the two demo kits may not work simultaneously if they are connected to PC via
an USB hub (in such case, try connecting the demo kits directly to PC with out USB hub).
VTI Technologies Oy 14/19
www.vti.fi Doc.Nr. 8268000.03 Rev.0.03