PC-R302 Series
LOW PROFILE 30 Watt Sine Wave Telephone Ring Generator
PowerDsine Ltd. Tel: +972-9-775-5100 • Fax: +972-9-775-5111 • Email: sales@powerdsine.com
PowerDsine, Inc. Tel: +1 -631-756-4680 • Fax: +1-631-756-4691 • Email: sales@powerdsineusa.com
PowerDsine Europe Tel: +49 -6187-900-849 • Fax: +49-6187-292848 • Email: europe@powerdsine.com
FEATURES
♦ External Digital Frequency Selection 17, 20, 25 and 50Hz
♦ External Digital/Analog Output Voltage Control 45-86Vrms 1
♦ Overload Protection with Advanced Output Power Control
♦ Output Short Circuit Protection
♦ Isolated Cadence Remote On/Off Control
♦ Soft Transition (Zero Crossing) Turn On & Off
♦ Isolated Zero Crossing Synchronization Output
♦ Isolated Output Good Indication Output
♦ Internal Thermal SOA Protection
♦ Input Under/Over Voltage Protection
♦ Internal RFI Filter
♦ UL1950, CSA C22.2 No. 950 and EN60950 Approved
♦ Four Quadrant Switch Mode Topology
♦
♦ High Reliability using SMD and Planar Magnetic Components
♦ Five Year Warranty
♦ PC-R301-XXX Series Compatibility
APPLICATIONS
♦ PBX, PABX, DLC and Key Systems
♦ Rural Telephony Systems
♦ Wireless Local Loop Systems
♦ Short/Long Loop POTS Applications
♦ Satellite Telephone and V SAT Terminals
♦ Test Equipment
DESCRIPTION
The PC-R302 Series Telephone Ring Generators offer a line of high
performance sine wave ring generators with an advanced constant
output power driving stage. The device is internally controlled by a
unique micro-controller, which enables flexibility in setting both the
output frequency in the range of 15 to 50Hz and output amplitude in
the range of 45 to 86Vrms 1. The internal controller automatically
adjusts and recovers the output amplitude for overload, over-
temperature, and short circuit.
At power connection or start -up by the Inhibit terminal, the device
turns it' output On and Off at the sine wave zero crossing, and
provides an isolated zero crossing synchronization output. The PC-
R302 Series advanced four-quadrant power topology delivers high
efficiency over the entire input voltage range of 36-72Vdc, and
operates at -40°C to +85°C.
Automatic Overload Control
Loads exceeding the maximum rated load by 1% to 20% activate the
Overload Protection. While the Overloa d Protection is active, the ring
generator automatically reduces its output amplitude and raises its
output current limit in order to sustain output power of approximately
30 Watt. The ring generator gradually reduces its output amplitude
from any set nominal amplitude until it reaches 45Vrms 2 for an
unlimited period. For handling overload that requires voltage lower
than 45Vrms, the device reduces its output amplitude to 30Vrms and
remains at this level for duration limited only by the thermal
protection. The device will shut off for a maximum duration of 2
seconds if the output current exceeds approximately 1Arms. While
the output is disabled, the Test output changes to a low logic level.
After a maximum delay of 2 seconds, the ring generator automatically
reverts to normal operation depending on its existing load condition.
This unique procedure ensures continuous service during overload
conditions.
1 The PC-R302-825 offers an extended output voltage control of 50-
95Vrms.
2 The minimum output voltage of the PC-R302 -825 is 50Vrms.
Output Overvoltage Protection
An independent internal protection circuitry shuts down the ring
generator in the event that the output voltage tries to exceed its
defined operating range. This feature allows meeting international
safety standards. The ring generator automatically recovers when the
output voltage returns to its safe operating range. An external
Transient Voltage Suppressor device should be used for external
high voltage transient protection.
Input Under/Over Voltage Protection
The input voltage protection circuitry shuts down the ring generator
when the input voltage is under/over the defined operating range.
The ring generator automatically reverts to normal operation when
the input voltage returns to its defined operating range.
Thermal Protection
An internal thermal protection automatically reduces the ring
generator output power, according to an internally programmed Safe
Operating Area, in the event that the internal temperature exceeds a
preset threshold. The ring generator automatically reverts to full
output power once the internal temperature reduces to the specified
operating temperature range.
Digital On/Off Control
The Inhibit control terminal (pin 7) functions to shut down the output
and reduces the device current consumption to an idling level. TTL
logic levels referenced to the FGND terminal (pin 6) operate the
Inhibi t terminal. When this input is disconnected or tied to a TTL low
level, the output is enabled. A logic high level inhibits the output and
minimizes the device's current consumption to an idling level. Turn
On and Off functions are executed during the outpu t sine wave zero
crossing, improving reliability.
Note that the Inhibit control can be used to generate the ringing
signal's On/Off intervals. Inhibit control eliminates the need for
additional external components in cadence implementation.