114-133082
18
3.10. Mounting Hole Pattern
The cooling device must be clean and flat with no crowns or peaks in the mounting area. The recommended
mounting hole pattern (not to scale) is provided on the customer drawing for the LUMAWISE Drive and is
shown in Figure 6, Mounting Hole Pattern.
After the holes are drilled and tapped, the surface must be cleaned with isopropyl alcohol. It is recommended to
install a paste or phase-change type thermal interface material (TIM) onto the COB area of the cooling device.
Please note the holder is designed for flathead screws only.
Figure 6
3.11. Reflector and optic clip
The LUMAWISE Drive is compatible with the Z50 optic clip type 1 and type 2 (part numbers: 2213194 and
2213349) to attach a reflector to the LUMAWISE Drive in order to create a directional beam of light. For
assembly instructions, please refer to the application sheet of the optic clip.
3.12. Assembly
CAUTION
The LUMAWISE Drive is designed for use in a ventilated environment that allows volatile organic compound (VOC) escaping.
To avoid damage to the LED, reflection of LED light from a diffuser directly onto the surface of the LUMAWISE Drive must be
prevented as much as possible.
1. The LUMAWISE Drive is suitable for the following COB sizes: 16x19 mm, 19x19 mm, 20x24 mm,
24x24 mm. All with a nominal thickness of 1 mm.
2. Remove release liner of adhesive tape, insert the COB and ensure you do not press the light emitting
(yellow part) part of the COB. The LED polarity indicator must be observed when orienting the COB into
the COB opening. Light pressure need to be applied to the bottom of the COB to overcome the resistance
of the crush ribs, which ensures centralization of the COB in the LUMAWISE Drive. The COB will stay in
place thanks to the adhesive tape. See Figure 7, details A.
CAUTION
To avoid damage to the LED, the COB must be properly positioned and seated in the LUMAWISE Drive. If not, the COB could
crack when mounting the LUMAWISE Drive to the cooling device.