SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE Note.5
EFFICIENCY (Typ.)
INPUT
FUNCTION
INRUSH CURRENT (Typ.)
OVER TEMPERATURE
WORKING TEMP.
OUTPUT OK SIGNAL
REMOTE ON/OFF CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
CURRENT (AT NO LOAD)
500ms, 50ms at full load
19 ~ 72VDC
24.2A/19VDC 24.8A/24VDC 12A/48VDC
Max. 0.2A/48VDC
60A/48VDC
105 ~ 125% rated output power
Protection type : Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover
16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V 16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +60 (Refer to "Derating Curve")
Please refer to function manual
Open collector signal low when PSU turns on, max. sink current :10mA
20 ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.02%/ (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
196.3K hrs min. MIL-HDBK-217F (25)
215*115*50mm (L*W*H)
1.15Kg; 12pcs/14.8Kg/0.92CUFT
86% 88% 89% 87%
8A/72VDC 6A/96VDC
60A/96VDC
Max. 0.1A/96VDC
89% 90%
±0.5% ±0.5% ±0.5% ±0.5%
72 ~ 144VDC
±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mVp-p
11 ~ 15V
150mVp-p
23 ~ 30V
150mVp-p
46 ~ 60V
150mVp-p
11 ~ 15V
150mVp-p 150mVp-p
23 ~ 30V 46 ~ 60V
12V
40A
0 ~ 40A
480W
24V
21A
0 ~ 21A
504W
48V
10.5A
0 ~ 10.5A
504W
12V
40A
0 ~ 40A
480W
24V 48V
21A 10.5A
0 ~ 21A 0 ~ 10.5A
504W 504W
SD-500L-12 SD-500L-24 SD-500L-48 SD-500H-12 SD-500H-24 SD-500H-48



  
    


 
SAFETY STANDARDS IEC60950-1 CB approved by TUV, approved EAC TP TC 004
Compliance to EN55032 (CISPR32) Class B, EAC TP TC 020
Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A, EAC TP TC 020
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION











500W Single Output DC-DC Converter SD-500 series
File Name:SD-500-SPEC 2018-01-12
EMC IMMUNITY
EMC EMISSION
Mechanical Specification
Derating Curve Static Characteristics
Case No. 912A Unit:mm
LOAD (%)
INPUT VOLTAGE (VDC)
19 24 36 48 72 96 144
90
for SD-500L for SD-500H
100
80
75
70
60
50
40
Block Diagram
AMBIENT TEMPERATURE ()
LOAD (%)
20
40
60
80
100
-20 0 10 20 30 40 45 50 60 70
BOOST fosc : 65KHz
PWM fosc : 110KHz
FAN
O.V.P.
-V
+V
RECTIFIERS
&
FILTER
-S
+S
CIRCUIT
DETECTION
POWER
AUX
REMOTE
CONTROL ON/OFF
OUTPUT
LIMITING
ACTIVE
CURRENT
INRUSH
CONTROL
ING
I/P SWITCH-
POWER
FILTER
EMI
PWM
BOOST
BOOST
CONTROL
O.T.P.
O.L.P.
Control Pin No. Assignment (CN3) : HRS DF11-6DP-2DS or equivalent
Pin No. Pin No.
1
5
4
2
3 6
Assignment Assignment
+S
-S
OUTPUT OK RCG
RC
GND
Mating Housing
or equivalent
HRS DF11-6DS
Terminal
JST SPHD-002T-P0.5
or equivalent
DC Input Terminal Pin No. Assignment
Pin No. Pin No.
1 4,5
3
2 6,7
Assignment Assignment
FG
DC INPUT V- +V
DC INPUT V+ -V
16
15
C
L
4-M4 L=5mm
5-M3 L=3mm
27.5 177.5
32.5 150
117.5
10 95
50
32.5
50.5
115
47.7
38.95
32.5 150
215
6-M4 L=5mm
25
50
Air flow
direction
14 max.
135
LED
+V ADJ.
CN3
2 1
6 5
5
4
6
7
1
2
3
8.6
10
only for SD-500L-12
500W Single Output DC-DC Converter SD-500 series
(HORIZONTAL)
File Name:SD-500-SPEC 2018-01-12
1.Remote ON/OFF
(1)Remote ON/OFF control becomes available by applying voltage in CN3
(2)Table 1.1 shows the specification of Remote ON/OFF function
(3)Fig.1.2 shows the example to connect Remote ON/OFF control function
Table 1.1 Specification of Remote ON/OFF
Fig.1.2 Examples of connecting remote ON/OFF
Connection Method
Output on SW Open
Fig. 1.2(A)
Output off SW Close
1KΩ
RCG
RC
SW
5V 1KΩRC
V
RCG
(A)Using external voltage source (B)Using external voltage source
2.Output OK signal
"Output OK" is an open collector signal.
It indicates the output status of the PSU. It can operate
in two ways : One is sinking current from external signal ;
the other is sending out a voltage signal.
2-1 Sink current :
The maximum sink current is 10mA and the maximum
external voltage is 13V.
2-2 Voltage signal :
Between O/P OK(pin3) and GND(pin4)
0 ~ 0.5V
12 ~ 13V
Output Status
ON
OFF
V=0~0.8Vdc
V=4~10Vdc
Fig. 1.2(B)
Function Description of CN3
Function Manual
Pin No. Function Description
1
3
5
6
4
2
+S
O/P OK
RC
RCG
GND
-S
Open collector signal, reference to pin4(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum
external voltage is 13V.
Remote ON/OFF
Remote ON/OFF ground
These pins connect to the negative terminal (-V).
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
500W Single Output DC-DC Converter SD-500 series
+S
1
-S
2
O/P OK
RC
GND RCG
CN3 5
6
+V ADJ.
+Vo +Vo -Vo -Vo TB1
CN3
1 5
2 6
File Name:SD-500-SPEC 2018-01-12
500W Single Output DC-DC Converter SD-500 series
The remote sensing compensates voltage drop on the
load wiring up to 0.5V.
3.Remote Sense
+S
1
-S
2
O/P OK
RC
GND RCG
CN3 5
6
+V ADJ.
+Vo +Vo -Vo -Vo TB1
CN3
1 5
2 6
-
+
LOAD -S
(pin2)
Sense lines should
be twisted in pairs
+S
(pin1)
File Name:SD-500-SPEC 2018-01-12