www.clare.com
2R04
CPC1972
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Operating Voltage Range - VL5 - 550 Vrms
Load Current
Continuous - IL5 - 250 mArms
Peak t = 10ms ITSM -- 2A
P
Off State Leakage Current VL=800VP I
LEAK -- 1µA
On-State Voltage Drop IL = 250mArms VON -- 3V
rms
Critical Rate of Rise - dV/dt 500 - - V/µs
Holding Current IF=5mA IH- 300 - µA
Switching Speeds
Turn-on IF=5mA ton - - 0.5 cycles
Turn-off toff - - 0.5
Zero-Cross Turn-On Voltage 11st half-cycle - - 5 20 V
Subsequent half-cycle - - 1 - V
Operating Frequency - - 20 - 500 Hz
Load Power Factor for Guaranteed Turn-On 2f=60Hz PF 0.25 - - -
Input Characteristics
Input Control Current 3-I
F-- 5mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Input Drop-out Voltage - - 0.8 - - V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Input to Output Capacitance - CI/O -3 -pF
1 Zero Cross 1st half-cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 For high noise environment use at least 10mA LED current
Parameter Ratings Units
Blocking Voltage 800 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Package Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC