©2014 Amprobe® For detailed specications and ordering go to www.Amprobe.com 6004306 AAmprobe® | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)
Feature VP-1000
Operating Voltage Range
90 Vac → 1000 Vac, 50/60 Hz
Sensitivity Lights at approx. 0.39 in (10 mm) distance from a wire carrying 120 Vac
Operating Temperature 32
°
F to 104
°
F (0
°
C to +40
°
C), ≤ 80% RH
Storage Condition 14
°
F to 122
°
F (-10
°
C to +50
°
C), ≤ 95% RH
Operating Altitude 2000 meters
Power Supply Two 1.5 V AAA batteries
Dimensions (L x W x H) 6.10 x 0.96 x 0.85 in (155 x 24.5 x 21.5 mm)
Weight
Approx. 0.11 lb (50 g) with batteries installed
Safety Compliance IEC 61010-1, UL 61010-1 2nd Ed. and CAN/CSA C22.2 No. 61010-1-04
EMC Compliance IEC 61326-1
Certication cCSAus and CE
Feature ST-102B
Operating Voltage
110 – 125 Vac, 50 – 60 Hz
Wattage 0.3 W
Actuator Black button
Indicator Red LED, three lights, neon
Lamp Lens Colors One red, two amber
Six Conditions Indicated Open ground, open neutral, open hot, hot/ground reverse, hot/neutral reverse, correct
Safety Compliance C22.2 No. 160-M1985 / UL 1436 – 4th Edition
Certication cCSAus
PK-110 Detailed Specifications
Feature AM-420 Best Accuracy
AC Voltage
200.0 / 250 V +/-(1.5% rdg + 4 LSD) @ 45 Hz to 400 Hz
DC Voltage 200 mV
2.000 / 20.00 / 200.0 / 250 V +/-(1.2% rdg + 2 LSD) @ 200 mV to 200 V
DC Current 200.0 µA
2.000 / 20.00 / 200.0 mA +/-(1.2% rdg + 5 LSD) @ 200 µA to 20 mA
Resistance
200.0 Ω
2.000 / 20.00 / 200.0 kΩ
2.000 MΩ
+/-(1.5% rdg + 5 LSD) @ 200 Ω to 200 kΩ
Continuity Beeps at ≤10 Ω, off at >70 Ω
Diode Test Open-circuit voltage is around 1.5V.
Normal voltage is around 0.5V to 0.8V for silicon PN junction.
Battery Test 1.5 V, 9 V +/-(8.0% rdg + 1 LSD)
Data Hold
•
General Specications:
Maximum Display 1999, updates 2 to 3/sec
Range Manual-ranging
Operating Temperature 32°F ~ 104°F (0°C ~ +40°C)
Relative Humidity
32°F ~ 86°F (0°C ~ +30°C) ≤75%; 86°F ~ 104°F (+30°C ~ +40°C) ≤50%
Operating Altitude
≤ 2000 m
Storage Temperature
14°F ~ 122°F (-10°C ~ +50°C)
Electromagnetic Compatibility
In an RF led of 1V/m = Specied accuracy ± 5%. RF eld > 1V/m is not specied.
Over-range Indication
“ 1 “, “-1” or maximum display reading
Battery
One 9V alkaline battery (6LF22, 6LR61, MN1604) or equivalent
Battery Life
Alkaline: 100 hours typical
Low Battery Indication
Overvoltage Category
CAT II 250V safety rated
Safety Compliance
IEC 61010-1, UL 61010-1 2nd Ed. and CAN/CSA C22.2 No. 61010-1-04 Update No.1:2008
EMC Compliance
IEC 61326-1
Certication
cCSAus and CE
Dimensions (L x W x H)
4.5 x 2.6 x 1.6 in (115 x 65 x 40 mm)
Weight Approximately 0.61 lb (275 g) with battery installed