GECA40
40 Watt Series
Commercial Wide-Range Input
AC Input
Universal Input 90-264 VAC, 47-63 Hz single phase.
Input Current
Maximum input current at 120 VAC, 60 Hz with full rated output load:
Multiple models 1.7 A, Single models 1.0 A.
Hold-Up Time
10 ms minimum with 40 W load, nominal line (120 VAC).
Output Power
40 W continuous, 45 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Overload Protection
Fully protected against short circuit and output overload. Short circuit
protection is cycling type power limit on V1 and V2, foldback type on V3.
Overvoltage Protection
On V1 is 120% to 160%. See chart.
Efficiency
75 to 80% at full rated load, nominal input voltage, depending on model
and load distribution.
Turn-on Time
Less than 2 seconds.
Input Protection
Internal AC fuse provided. Designed to blow only if a catastrophic failure
occurs in the unit. Fuse does not blow on overload or short circuit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 VAC under cold
start conditions will not exceed 37A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Temperature Range
Designed for 0 to 45°C operation at full rated output power; derate output
current and total output power by 2.5% per °C above 45°C.
• Wide-Range AC Input 90-264 VAC
• Industry Standard Footprint - 3”x 5”x 1.25”
• Conducted EMI Exceeds FCC Class B and
CISPR 22 Class B
• Single and Multiple Outputs
• Approved to UL60950-1: 2003, CSA-22.2 No. 60950-1-03,
IEC and EN60950-1
• CB Report Available
• RoHS Compliant
Marked to LVD
2 Year Warranty
Output Noise
0.5% rms, 1% pk-pk typical (see chart), 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output terminals of the
power supply with load terminated with 0.1 μF capacitor.
Transient Response
Main output—500 μs typical response time for return to within 0.5% of
final value for a 50% load step change. i/ t<0.2 A/μs. Maximum voltage
deviation is 3.5%. Startup/ shutdown overshoot less than 3%.
Switching Frequency
70 kHz +/-10 kHz.
Voltage Adjustment
Provided on V1. Adjustable voltages are preset at factory. Outputs are
capable of minimum +/- 5% change from nominal setting. Multiple output
models - V2 voltage will track V1 adjustment.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions
requirements:
EMI SPECIFICATIONS COMPLIANCE LEVEL
Conducted Emissions EN55022 Class B; FCC Class B
Static Discharge EN61000-4-2, Level 3
RF Field Susceptibility EN61000-4-3, Level 3
Fast Transients/Bursts EN61000-4-4, Level 3
Surge Susceptibility EN61000-4-5, Level 3
Safety Approvals
SL Power Electronics, Corp. declares under our sole responsibility
that all GECA models are in conformity with the applicable requirements of
EN60950 following the provisions of the Low Voltage Directive 73/23/EEC.
All GECA models are approved to UL60950-1: 2003,
CSA-22.2 No. 60950-1-03, IEC and EN60950-1
MTBF
120kHrs.
Specifications
SL Power Electronics, Corp. 6050 King Drive Ventura CA, 93003 Phone:805.486.4565 Fax:805.487.8911 Email:info@slpower.com www.slpower.com
Unless otherwise noted, all parameters are nominal values measured at 120 VAC @25˚C and 0-95%
relative humidity, non-condensing. For limits at unusual operatiing conditions, consult factory.
GECA40
40 Watt Series
Commercial Wide-Range Input
Commercial Output Output Current Current Line Load V1 OVP Ripple &
Model No. (V) Minimum Maximum Regulation Regulation Set Point Noise(P-P)
GECA40AG V1 +5 V 0.35 A 3.5 A +/-0.5% +/-3% 6.6 +/-0.9 V 50 mV
V2 +12 V 0 A 2 A +/-1% +/-10% 120 mV
V3 -12 V 0 A 0.3 A +/-1% +/-5% 120 mV
GECA40BG V1 +5 V 0.35 A 3.5 A +/-0.5% +/-3% 6.6 +/-0.9 V 50 mV
V2 +12V 0 A 2 A +/-1% +/-10% 120 mV
V3 -5 V 0 A 0.3 A +/-1% +/-5% 50 mV
GECA40HG V1 +3.3 V 0.4 A 4 A +/-0.5% +/-3% 4.4 +/-0.6 V 50 mV
V2 +12 V 0 A 2 A +/-1% +/-10% 120 mV
V3 -12 V 0 A 0.3 A +/-1% +/-5% 120 mV
GECA40DG V1 +5 V 0.35 A 3.5 A +/-0.5% +/-3% 6.6 +/-0.9 V 50 mV
V2 +24 V 0 A 1.2 A +/-1% +/-10% 240 mV
V3 -12 V 0 A 0.3 A +/-1% +/-5% 120 mV
GECA40-5G V1 5 V 0 A 7 A +/-0.5% +/-3% 7.0 +/-1.0 V 50 mV
GECA40-12G V1 12 V 0 A 3.3 A +/-0.5% +/-3% 16.8 +/-2.4 V 120 mV
GECA40-15G V1 15 V 0 A 2.7 A +/-0.5% +/-3% 21.0 +/-3.0 V 150 mV
GECA40-24G V1 24 V 0 A 1.7 A +/-0.5% +/-3% 33.6 +/-4.8 V 240 mV
CON 1:
MOLEX P/N 26-60-4030, w/center PIN Removed
0.156 [3.96 mm] CTR Header
CON 2:
MOLEX P/N 26-60-4060, 0.156 [3.96 mm] CTR Header
Input J1
PIN 1) AC Line
PIN 3) AC Neutral
Output J2
Multiple Output Single Output
Models Models
PIN 1) Output 2 Output 1
PIN 2) Common Output 1
PIN 3) Common Output 1
PIN 4) Output 1 Common
PIN 5) Output 1 Common
PIN 6) Output 3 Common
Mating Connector Housing P/N Contacts P/N
MOLEX
Input 09-50-3031 08-52-0072
Output 09-50-3061 08-52-0072
Note: 5A maximum recommended current per Connector PIN
Weight
1.0 lbs Max [0.45 kg Max.]
Tolerance
X.XX=0.030
X.XXX=0.010 [0.mm]
GECA40 Series Mechanical Specifications
ENVIRONMENT OPERATING NON-OPERATING
Temperature (A) 0 to 45°C -40 to +85°C
Humidity (A) 20 to 90% RH 10 to 95% RH
Shock (B) 20 gpk 40 gpk
Altitude -500 to 10,000 ft -500 to 40,000 ft
Vibration (C) 1.5 grms’ 0.0032 g2/Hz 5 grms’ 0.026 g2/Hz
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction,
3 orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.
Environmental Specifications
SL Power Electronics, Corp. 6050 King Drive Ventura CA, 93003 Phone:805.486.4565 Fax:805.487.8911 Email:info@slpower.com www.slpower.com
Data Sheet © 2006 SL Power Electronics, Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Rev.8/30/06