© 2018 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S134 Page 1
Series S134
DPDT Non-Latching
Commercial Electromechanical Relay
S134\082018\Q3
SERIES RELAY TYPE
S134 DPDT basic relay
S134D DPDT relay with internal diode for coil transient suppression
S134DD DPDT relay with internal diodes for coil transient suppression and polarity reversal protection
DESCRIPTION
The Series S134 Surface Mount Centigrid® Relay is an ultraminiature,
hermet ically s ealed, armatu re relay. T he low p rofile height (.360”) and .100
lead spacing make it ideal for applications where extreme packaging density
and/or close PC board spacing are required. The specially formed leads are
pre -t inne d to make t he rel ays idea l for mo st ty pes of s ur fac e mount s old er
reflow processes.
The basic design and internal construction are identical to the Series
134 Centigrid® relays, and are capable of meeting Teledyne Relays’
T2R® requirements. The following unique construction features and
manufacturing techniques provide overall high reliability and excellent
resistance to environmental ex tremes:
The S134 f ea t ur e:
• Al l wel de d c ons tr u ct i on.
• Hig h fo rc e /mas s ra ti os f or r esi st an c e to sh oc k an d vi br ati on.
• Unique uni-frame design providing high magnetic eff iciency and
mechanical rigidit y.
• Advanced cleaning techniques provide maximum assurance of
internal cleanliness.
• Prec i ou s met al a ll oy c ont a ct m ate r ial w it h g ol d pl ati ng as s ure s exce ll ent
hig h cu r re nt and d ry c ir c uit s wi tc hin g c ap ab ili t ie s.
The Series S134D and S134DD relays have internal discrete silicon
diodes for coil suppression and polarity reversal protection.
The s en sit ive s urfac e m ount C e nti gr i d ® r el ay has a hi gh r es is ta nc e
co il, t hus r eq uir i ng ex tr em el y low o p erat in g po wer (20 0 m w t yp ic a l). The
advant ag es of r ed uc e d heat d is si pat io n and p owe r sup ply d em and s ar e
a plus
INTERNAL CONSTRUCTION
CENTIGRID®
SURFACE MOUNT
COMMERCIAL RELAYS
SENSITIVE DPDT
Part Numbering System
S134 - 26 / R
Relay Series
Q = Solder-Coated Leads1
(Surface Mount Relays are
Solder-Coated by default)
R = RoHS Compliant Solder2
Nominal Coil Voltage
(26 = 26.5 V,
See Page 2 for more Voltages)
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Operating) –55°C to +85°C
Vibration
(General Note I) 30 g’s to 3000 Hz
Shock
(General Note I)
50 g’s,
6ms half sine
Acceleration 50 g’s
Enclosure Hermetically sealed
Weight 0.15 oz. (4.3g) max.
Reflow Temperature 260°C max. temp.
1 min. max
UPPER
STATIONARY
CONTACT
LOWER
STATIONARY
CONTACT MOVING
CONTACT
UNI-FRAME
ARMATURE
S134 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS
Series S134
DPDT Non-Latching
Commercial Electromechanical Relay
S134\082018\Q3
SERIES S134
GE NE RAL E LECT RI CAL SPECI FI CATI O NS (- 5 5 °C t o 8 5 °C un l es s o th e rw i se n ot e d. S e e n ot e s 2 & 3.)
Contact Arrangement 2 Form C (DPDT)
Rated Duty Continuous
Contact Resistance 0.10 Ω max.
Contact Load Rating (DC)
Resistive: 1 A/ 28 Vdc
Inductive: 200 mA/ 28 Vdc (320mH)
Lamp: 100 mA / 28 Vdc (320mH)
Low level: 10 to 50 μA @ 10 to 50 mV
Contact Load Rating (AC) Resistive: 250 mA / 115Vac, 60 and 400 Hz (Case not grounded)
100 mA / 115 Vac, 60 and 400 Hz (Case grounded)
Contact Life Ratings 10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5 A / 28 Vdc resistive
100,000 cycles min. at all other loads speci ed above
Contact Overload Rating 2 A / 28 Vdc Resistive (100 cycles min.)
Coil Operating Power 200 mW typical at nominal rated voltage
Contact Carry Rating Contact Factory
Operate Time 4.0 msec max. at nominal rated coil voltage
Release Time S134: 1.5 ms max. S134D, S134DD: 4.0 ms max.
Contact Bounce 1.5 msec max.
Intercontact Capacitance 0.4 pf typical
Insulation Resistance 10,000 MΩ min. between mutually isolated terminals
Dielectric Strength 500 Vrms (60 Hz) @ atmospheric pressure
Negative Coil Transient (Vdc) 1.0 Vdc Max.
Diode P.I.V. (Vdc) 100 Vdc Min.
BASE PART NUMBERS
(S134, S134D, S134DD)
S134-5
S134D-5
S134DD-5
S134-6
S134D-6
S134DD-6
S134-9
S134D-9
S134DD-9
S134-12
S134D-12
S134DD-12
S134-18
S134D-18
S134DD-18
S134-26
S134D-26
S134DD-26
Coil Voltage Nom. 5.0 6.0 9.0 12.0 18.0 26.5
Max. 7.5 10.0 15.0 20.0 30.0 40.0
Coil Resistance
(Ohms ±10% @25°C) S134, S134D 100 200 400 800 1600 3200
S134DD 64 125 400 800 1600 3200
Coil Curent (S134DD)
(mAdc@25°C) (Note 5) Min. 56.8 36.3 18.1 12.5 9.6 7.2
Max. 78.1 48.9 23.6 16.0 12.2 9.0
Pick-up Voltage
(Vdc, Max) S134, S134D 3.5 4.5 6.8 9.0 13.5 18.0
S134DD 3.7 4.8 8.0 11.0 14.5 19.0
Drop-out Voltage
(Vdc)
S134,
S134D Min. 0.12 0.18 0.35 0.41 0.59 0.89
Max. 2.5 3.2 4.9 6.5 10.0 13.0
S134DD Min. 0.7 0.8 0.9 1.0 1.1 1.3
Max. 2.6 3.0 4.5 5.8 9.0 13.0
DETAILED ELECTRICAL SPECIFICATIONS (-55 °C to 85 °C unless otherwise noted. See note 3.)
© 2018 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S134 Page 3
Series S134
DPDT Non-Latching
Commercial Electromechanical Relay
S134\082018\Q3
TYPICAL DC CONTACT RATING (RESISTIVE)
LOAD VOLTAGE (VDC)
0
.1
.2
.3
.4
10
20
30
40
50
60
70
.01 0.5 .1 .5 1.0
FREQUENCY (GHz)
FIGURE 1
TYPICAL RF PERFORMANCE
1.92
1.22
1.07
1.02
1.01
1.00
1.00
VSWR
dB
RETURN LOSS (VSWR)
ISOLATION ACROSS CONTACTS
ISOLATION ACROSS POLES
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
FIGURE 2
INSERTION LOSS
GENERAL NOTES
1. Relay contacts will exhibit no chatter in
excess of 10 μsec or transfer in excess
of 1 μsec.
2. “Typical” characteristics are based on
available data and are best estimates.
No on-going verification tests are
performed.
3. Unless otherwise specified, parameters
are initial values.
4. Relays can be supplied with a spacer
pad. See appendix.
PERFORMANCE CURVES (Note 2)
SERIES S134
OUTLINE DI MENSI ONS
SCHEMATIC DIAGRAMS
S134 S134D S134DD
(Viewed From Terminals)
1
2
3
4
5
6
78
3
4
8
7
62
1
53
4
8
7
62
1
5
.335 MAX
(8.51)
.375 MAX
(9.53) .460 MAX
(11.68)
Ø.017 REF
(.43) 2° ±2° TYP
.378 +.030
–.020 TYP
9.60 +.76
–.51
()
.031 REF (.79)
4° MAX TYP
4° MAX TYP
.035 REF
(.89)
.045 MIN 8 PL
(1.14)
.100 4 PL
(2.54)
.200
(5.08)
.100 TYP (2.54)
.200
(5.08)
(Note 6)
.375 SQ MAX
(9.53)
.200
(5.08)
.410 MIN
(10.41)
NOTES:
1. RELAY CONTACTS WILL EXHIBIT NO CHATTER IN EXCESS OF 10 MSEC OR TRANSFER IN EXCESS OF 1 MSEC.
2. “TYPICAL” CHARACTERISTICS ARE BASED ON AVAILABLE DATA AND ARE BEST ESTIMATES. NO ON-GOING VERIFICATION TESTS ARE PERFORMED.
3. UNLESS OTHERWISE SPECIFIED, PARAMETERS ARE INITIAL VALUES.
4. FOR REFERENCE ONLY. COIL RESISTANCE NOT DIRECTLY MEASURABLE AT RELAY TERMINALS DUE TO INTERNAL SERIES DIODE.
5. MEASURED AT NOMINAL VOLTAGE FOR 5 SEC. MAX.
6. POSITION OF LEADS AS THEY EMERGE FROM RELAY BASE.
7. LEADS WILL FIT NOTED PAD LAYOUT WITH NO OVERHANG.
8. LEAD ENDS ARE COPLANAR WITHIN .008” WIDE TOLERANCE ZONE.
9. TERMINALS COATED WITH SN60 OR SN63 SOLDER PER QQ-S-571. KOVAR EXPOSED AT SHEARED END OF LEADS.
Page 4 (800) 284-7007 • www.teledynerelays.com • +44 (0) 1236 453124 • www.teledyne-europe.com © 2016 TELEDYNE RELAYS
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M4” Pad for TO-5
ER412, ER412D, ER412DD .295 (7.49)
712, 712D, 712TN,
RF300, RF310, RF320
RF700, RF703
.300 (7.62)
ER420, ER420D, ER420DD, 421,
ER421D, ER421DD, ER422, ER422D,
ER422DD, 722, 722D, RF341
.305 (7.75)
ER431T, ER432T,
ER432, ER432D, ER432DD .400 (10.16)
732, 732D, 732TN, RF303, RF313,
RF323 .410 (10.41)
RF312, RF332
SI800, SI803 .350 (8.89)
“M4” Pad for TO-5
ER411, ER411D, ER411DD, ER411T .295 (7.49)
ER431, ER431D, ER431DD .400 (10.16)
RF311 .300 (7.62)
RF331 .410 (10.41)
“M4” Pad for Centigrid®
172, 172D .305 (7.75)
ER114, ER114D, ER114DD,
J114, J114D, J114DD .300 (7.62)
ER134, ER134D, ER134DD,
J134, J134D, J134DD .400 (10.16)
RF100 .315 (8.00)
RF103 .420 (10.67)
“M9” Pad for Centigrid®
122C, A152 .320 (8.13)
ER116C, J116C .300 (7.62)
ER136C, J136C .400 (10.16)
RF180 .325 (8.25)
A150 .305 (7.75)
Notes:
1. Spacer pad material: Polyester lm.
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering
example in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010” (.25 mm).
5. Add 10 mΩ to the contact resistance shown in the datasheet.
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
Ø.150
[3.81]
(REF)
Dim H
MAX
Dim H
MAX
Dim H
MAX
.156
[3.96]
(REF)
.256
[6.5]
(REF)
Dim H
MAX
APPENDIX: Spacer Pads
© 2016 TELEDYNE RELAYS SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 5
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M” Pad 5/ 6/
ER411T, J411T, ER412, ER412D
ER412DD, J412, J412D, J412DD
ER412T, J412T
.388 (9.86)
712, 712D, 712TN .393 (9.99)
ER431T, J431T, ER432, ER432D
ER432DD, J432, J432D, J432DD
ER432T, J432T
.493 (12.52)
732, 732D, 732TN .503 (12.78)
ER420, J420, ER420D, J420D
ER420DD, J420DD, ER421, J421
ER421D, J421D, ER421DD
J422D, ER422DD, J422DD, 722
.398 (10.11)
“M2” Pad 7/ 8/
ER411T
ER412, ER412D, ER412DD
J412, J412D, J412DD .441 (11.20)
712, 712D .451 (11.46)
ER421, ER421D, ER421DD
722, 732D .451 (11.46)
ER431T
ER432, ER432D, ER432DD .546 (13.87)
732, 732D .556 (14.12)
“M3” Pad 5/ 6/ 9/
ER411, ER411D, ER411DD, ER411TX
ER412X, ER412DX, ER412DDX
ER412TX
.388 (9.86)
712X, 712DX, 712TNX .393 (9.99)
ER420X, ER420DX, ER420DDX
ER421X, ER421DX, ER421DDX
ER422X, ER422DX
ER422DDX, 722X, 722DDX
.398 (10.11)
ER431, ER431D, ER431DD
ER431TX
ER432X, ER432DX, ER432DDX
ER432TX
.493 (12.52)
732X, 732DX, 732TNX .503 (12.78)
Notes:
1. Spreader pad material: Diallyl Phthalate.
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example
in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010” (0.25 mm).
5/. Add 25 mΩ to the contact resistance shown in the datasheet.
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
7/. Add 50 mΩ to the contact resistance shown in the datasheet.
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
.390 [9.91]
SQ
.300
[7.62]
.100
[2.54]
.300
[7.62]
.100
[2.54] .150
[3.81]
.150
[3.81]
.130
[3.3]
Dim H
MAX
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
APPENDIX: Spreader Pads
Page 6 (800) 284-7007 • www.teledynerelays.com • +44 (0) 1236 453124 • www.teledyne-europe.com © 2016 TELEDYNE RELAYS
.100
[2.54]
.100
[2.54]
.100
[2.54]
"Y" POSITION
"Z" POSITION
.100
[2.54]
.100
[2.54]
.100
[2.54]
"W" POSITION
"U" POSITION
(ER116C and ER136C only)
"X" POSITION
"Z" POSITION
"Y" POSITION
.050
[1.27]
36°±3°
Ø.200
[Ø5.08]
"Z" POSITION
"Y" POSITION
"X" POSITION
45°±3°
"Z" POSITION
"Y" POSITION
Ø.200
[Ø5.08]
Centigrid® Relays:
RF100, RF103, ER114, ER134, 172
Centigrid® Relays:
RF180, ER116C, 122C, ER136C
TO-5 Relays:
ER411T, ER412, ER412T, ER420, ER421, ER422,
ER431T, ER432, ER432T, 712, 712TN, 400H, 400K,
400V, RF300, RF303, RF341, RF312, RF332, RF310,
RF313, RF320, RF323, SI800, SI803, RF700, RF703
TO-5 Relays:
ER411, ER431, RF311, RF331
NOTES
1. Terminal views shown
2. Dimensions are in inches (mm)
3. Tolerances: ± .010 (±.25) unless otherwise speci ed
4. Ground pin positions are within .015 (0.38) dia. of true position
5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref.
6. Lead dia. 0.017 (0.43) nom.
Indicates ground pin position
Indicates glass insulated lead position
Indicates ground pin or lead position
depending on relay type
APPENDIX: Ground Pin Positions
Loopback Relays:
LB363
“Z” Position
“Y” Position