Special Features
Electrical Specs
15 Watts
AK42A Dual
• Surface mount
• High power density 15W/Cu. in.
• Full power capability without
external heat sink
• Input differential and
common mode filtering
• Hot insertable with inrush current limit
• Ability to limit inrush current in
an external input capacitor
• Input undervoltage lockout with hysteresis
• Output overvoltage protection
• Remote shutdown
• Loadsharing on dual outputs
Operating ambient temperature range:
-40 to +75° C (no derating)
Cooling method: Convection
MTBF: 7.5 MHrs
Storage temperature: -55 to +125 C
UL 1950
IEC 950
CSA C22.2-9.50
CB 52719-106
Input
Input Range: 36 to 75 VDC for 48V
18 to 36 VDC for 24V
Maximum Inrush
Current Limit: 1.0 A Max.
Maximum External
Capacitor to Limit
Inrush Current to 1.0 A: 4.0mF
Low Input Shutdown: 34.0 +/- 2.0 V for 48V
17.0V +/- 1.0V for 24 V
Auto Recovery: 37.0V +/- 2.0 V for 48V
18.5V +/- 1.0 V for 24V
Hysteresis: 3 V +/- 1 V for 48V
1.5V +/- 0.5V for 24V
Efficiency: 85%
Enable: Open Circuit or up to 0.5V max.
Disable: 4V min., 75V max.
Output
Voltage Tolerance: ± 3% for single output
± 5% for dual output
Noise/Ripple: 75mV rms max.
Output Voltage
Adjust Range: ±10% for single output
dual output non adjustable
Output Voltage
Protection Self-limiting Clamp, 140% max.
Short Circuit
Protection Continuous Auto Start
Switching Frequency: 200kHz nominal
Environmental
Total Power: 15 Watts
Input Voltages: 48V, 24 VDC
No. of Outputs: Dual
Safety
Astec Conventional Power
America’s (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662
68