1www.xilinx.com DS019 (v1.5) January 13, 2000
Device and Packa ge Support
XC1700 Seri al PROMs
XC1800 Seri al PROMs
XC9500/XL CPLDs
Supports all Xilinx package types
Programm er Accessories
Universal power supply
Power cord options for US/Asia, UK, European and
Japanese standards.
Serial download cable and adapters
•Users manual
Programmer interface software
Vacuum handling tool
Interface Software and System
Requirements
The programmer software operates on a Windows 32-bit
platform. Table 1 indicates the minimum system require-
ments for each. In all cases, a CD-ROM drive and an
RS-232 serial port are required. A mouse is recommended.
Programmer Func tio nal S peci fications
Device programming, erasing and verification
CPLD security control
Serial PROM reset polarity control
Checksum calculation and comparison
Blank check and signature ID tests
Master device upload
File transfer and comparison
Self check and auto calibration
Programming Socket Adapters
Supports all package styles: PLCC, PQFP, TQFP,
VQFP, HQFP, BGA, SOIC, VOIC, CSP and DIP.
Purchase as needed for specific package support.
Electrical Req uirements and Physical
Specifications
Operating voltage: 100-250 VAC, 50-60 Hz
Power consumption: 0.5 Amp
Dimensions: 6" x 8" x 2" programmer, 3" x 5" x 1.75"
power supply
Weight: 1.2 lb. programmer, 1.3 lb. power supply
Safety standards: approved by UL, CSA, TUV, CE
Ne w Pr ogramming Algorithm Su pport
The new programmer algorithms are av ailab le via the Xilinx
WEB site:
To access programmer software from the Xilinx WEB
site, go to www.xilinx.com. The URL for the index of
HW-130 software can be found at:
www.xilinx.com/techdocs/htm_index/sw_programmer.htm
0
HW-130 Programmer
DS019 (v1.5) January 13, 2000 08*
Product Specification
R
Table 1: Interface Software and System Requirements
Requirements Windows 95 Windows 98 Windows NT
Memory Needed 8 MB 16 MB 16 MB
Hard Disk Space 15 MB 15 MB 15 MB
HW-130 Host
Software 4.00
or greater 4.10
or greater 3.1 or gre ate r
R
HW-130 Programmer
2DS019 (v1.5) January 13, 2000
1) Xilinx has manufactured two versions of the HW-133-PQ160 adapte r. The current and correct adapter for programming
XC9500 devices has CPLD written on the front label, at the top left side, under the Xilinx logo.
Revision Control
Adapter Selection Table
Product Family Package Types Adapter P/N
XC9500/XL PLCC44 HW-133-PC44
XC9500 VQFP 44 HW-133-VQ44
XC9500/XL CSP 48 HW-133-CS48
XC9500XL VQFP 64 HW-133-VQ64
XC9500 PLCC 84 HW-133-PC84
XC9500 PQFP 100 HW-133-PQ100
XC9500/XL TQFP 100 HW-133-TQ100
XC9500XL CSP 144 HW-133-CS144
XC9500XL TQFP 144 HW-133-TQ144
XC95001PQFP 160 HW-133-PQ160
XC9500/XL PQFP/HQFP 208 HW-133-HQ208
XC9500/XL BGA 352 HW-133-BG352
XC1700 & XC17S00 DIP 8 HW-137-DIP8
XC1700 & XC17S00 PLCC20/SO8/VO8 HW-137-PC20/SO8
XC1700 & XC17S00 SO20 HW-137-SO20
XC1700 PLCC 44/VQFP 44 HW-137-LCC44/VQ44
XC1800 PLCC 44/VQFP 44 HW-137-LCC44/VQ44
Calibration Adapter - HW-130-CAL
Date Version Revision
6/13/98 1.3 Added Windows 98 system requirements, added HW-137-LCC44/VQ44 to Adapter se-
lection table.
11/27/98 1.4 Removed DOS and Windows 3.1 support. Revised the Physical Specifications to include
the power supply dimensions and weight. Removed the obsolete XC7200/7300 product
families. Added package adapters for the XC9500/XL series in CSP 48, VQ FP 64, CSP
and TQFP 144 packages.
01/13/00 1.5 Added DS number, and XC1800 Serial PROM adapters. Added version column to revi-
sion control table.