Current Transducer HX 03..50-P For the electronic measurement of currents: DC, AC, pulsed, mixed, with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 3 .. 50 A All data are given with RL = 10 kW Electrical data Primary nominal current rms IPN (A) Primary current measuring range IPM (A) 3 5 10 15 20 25 50 9 15 30 45 60 75 150 VOUT ROUT RL VC VC Features Primary conductor Type diameter x turns (mm) Galvanic isolation between primary and secondary circuit Hall effect measuring principle Isolation voltage 3000V Low power consumption Extended measuring range (3 x IPN) Power supply from 12V to 15V Isolated plastic case recognized according to UL 94-V0. HX 03-P HX 05-P HX 10-P HX 15-P HX 20-P HX 25-P HX 50-P 0.6d x 20T 0.8d x 12T 1.1d x 6T 1.4d x 4T 1.6d x 3T 1.6d x 2T 1.2 x 6.3 x 1T Output voltage (Anarog) @ IPN, RL = 10 kW, TA = 25 C Output internal resistance Load resistance Supply voltage ( 5 %) 1) Current consumption 4 < 50 10 15 < 15 V W kW V mA Accuracy - Dynamic performance data X Accuracy @ IPN , TA = 25C (xcluding offset) < 1 % of IPN Linearity error (0 .. I ) < 1 % of IPN L PN VOE Electorical offset voltage @ IP = 0, TA = 25C < 40 mV VOH Hysteresis offset voltage @ IP = 0 after an excursion of 1 x IPN < 15 mV TCVOE Temperature coefficient of VOE < 1.5 mV/K TCVOUT Temerature coefficient of VOUT (% of reading) 0.1 %/K tr Response time to 90% of IPN step 3 s BW Frequency bandwidth (- 3 dB) 2) 50 kHz General data TA TS m Ambient operating temperature Ambient storage temperature Mass ... Standards Note: 1) 2) - 25 .. + 85 C - 25 .. + 85 C 8 g EN 50178: 1997 Also operate at 12V power supples, measuring range reduced to 2.5 x IPN. Small signal only to avoid excssive heating of the magnetic cores. Advantages Low insertion losses Easy to mount with automatic handling system Small size and space saving Only one design for wide current ratings range High immunity to external interference Applications AC variable speed drives DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Electrical appliances Application domain Industrial Page 1/3 110523/14 . LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Current Transducer HX 03..50-P Isolation characteristics Vd Ve Vw Rms voltage for AC isolation test, 50 Hz, 1 min Partial discharge extinction voltage rms @ 10 pC Impulse withstand voltage 1.2/50 s > 3 1 6 kV kV kV dCp dCI CTI Creepage distance Clearance distance Comparative Tracking Index (group I) 5.5 5.5 600 mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: Over voltage category OV 3 Pollution degree PD2 Non-uniform field EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Basic insulation 600 V 600 V Reinforced insulation 300 V 150 V dCp, dCI,Vw Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 110523/14 . LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HX 03..50-P.(in mm. 1 mm = 0.0394 inch) HX03...25-P 03..25-P HX 50-P HXHX 50-P 19 Max. 19 Max. Terminal Pin Identification 20 Max. 20 Max. 10.85 3 3.5 0.5 0.5 3.5 3.5 3 1 ..... -15 V 2 ..... 0 V 3 ..... +15 V 4 ..... Output 5 ..... Primary input Current (+) 6 ..... Primary input Current (-) 3 8.8 5.4 Primary conductor diameter d 5 5 3 +V 2 0 1 -V or 0 1.3 5 3-P=2.54 1 -V or 0 6 2 0 6 4 OUT 15.4 Max. 6 3 +V 15.4 Max. 3-P=2.54 4 OUT HX 03-P 05-P 10-P 15-P d 0.6 0.8 1.1 1.4 HX 20-P 25-P 50-P d 1.6 1.6 1.2 x 6.3 1.2 3 3 10.85 Top view 8.8 5.4 Secondary pins dimension 0.5 x 0.25 HX 05-P CN2 410123 41123 Lot No. Mechanical characteristics General tolerance 0.5 mm Page 3/3 110523/14 . LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com