Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
Input Diode
VF Forward Voltage - - 1.8 V
IF = 40 mA, TA = 25° C
IR Reverse Current - - 100 μA VR = 2.0 V, TA = 25° C
Output Photologic® Sensor
VCC Operating DC Supply Voltage 4.75 - 5.25 V
ICCL
Low Level Supply Current:
Buffered Totem-Pole Output(5)(6)
Buffered Open-Collector Output(5)(6)
-
-
-
-
10
10
mA
mA
Vcc = 5.25 V, If = 0 mA (output open)
Inverted Totem-Pole Output(5)
Inverted Open-Collector Output(5)
-
-
-
-
10
10
mA
mA Vcc = 5.25 V, If = 0 mA (output open)
ICCH
High Level Supply Current:
Buffered Totem-Pole Output(5)(6)
Buffered Open-Collector Output(5)
-
-
-
-
10
10
mA
mA
Vcc = 5.25 V, If = 25 mA (output open)
Inverted Totem-Pole Output(5)(6)
Inverted Open-Collector Output(5)(6)
-
-
-
-
10
10
mA
mA Vcc = 5.25 V, If = 0 mA (output open)
IOH
High Level Output Voltage:
Buffered Open-Collector Output
-
-
-
-
100
100
µA
µA
Vcc = 4.5 V, If = 25 mA, VOH = 30 V,
TA=25°C
Inverted Open-Collector Output - - 100 µA Vcc = 4.5 V, If = 0 mA, VOH = 30 V, TA =
25°C
Absolute Maximum Ratings (TA=25°C unless otherwise noted)
Supply Voltage, VCC (not to exceed 3 seconds) 10 V
Storage Temperature Range -40° C to +85° C
Operating Temperature Range -40° C to +70° C
Lead Soldering Temperature (1/16” inch (1.6 mm) from case for 5 seconds with soldering iron)(1) 260° C
Input Diode Power Dissipation(2) 100 mW
Output Photologic® Power Dissipation(3) 200 mW
Total Device Power Dissipation(4) 300 mW
Voltage at Output Lead (Open Collector Output) 35 V
Diode Forward DC Current 40 mA
Diode Reverse DC Voltage 3 V
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 seconds maximum when flow soldering.
(2) Derate linearly 2.22 mW/°C above 25° C.
(3) Derate linearly 4.44 mW/°C above 25° C.
(4) Derate linearly 6.66 mW/°C above 25° C.Normal application would be with light source blocked, simulated by IF=0 mA.
(5) Tested at d = 0.080” (mm) from a 90% diffuse white test surface.
(6) Normal application would be with light source blocked, simulated by IF = 0 mA.
(7) All parameters tested using pulse technique.