A3P
15
Ordering Information
Tools
Specifications
Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Standard Load: 5 A at 125 VAC
3 A at 250 VAC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
CCC (GB14048.5)
Standard Load: 3 A at 250 VAC
4 A at 30 VDC
Microload: 0.1 A at 125 VAC
0.1 A at 30 VDC
Ratings
Contact Ratings
Silver Alloy Contacts (for Standard Loads)
Note: 1. The above values are for steady-state currents.
2. Inductive load: Power factor = 0.4; time constant = 7 ms.
3. The lamp load has an inrush current of 10 times the steady-state current.
4. The motor load has an inrush current of 6 times the steady-state current.
Standard testing condition
(1) Ambient temperature: 20 ± 2°C
(2) Ambient humidity: 65 ± 5%RH
(3) Operating frequency: 20 times/min.
Gold Alloy Contacts (for Microloads)
LED and Incandescent Lamp Ratings
LED for LED-lighted Models
LED for Chameleon Models
Incandescent Lamp
LED Lamp (for LED Lamp-lighted Models)
Characteristics
*1. With alternate operation models, 60 operations/minute max. One operation
cycle consists of set and reset operations.
*2. 600 VAC for microloads.
*3. With no incandescent lamp or LED lamp mounted.
Name Appearance Classification Model Application precautions
Extractor
--- A3PJ-5080 • Use to extract components when
replacing the Pushbutton.
Rated
voltage
(V)
Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5
3
0.7
0.5
3
2
1.3
0.8
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5
5
4
0.4
0.2
2
2
2
0.05
0.03
4
4
3
0.4
0.2
3
3
3
0.05
0.03
Rated voltage (V) 0.1 A at 30 VDC (resistive load);
0.1 A at 125 VAC (resistive load)
Minimum applicable load 1 mA at 5 VDC
Model A3PJ/M2PJ
A3PA/M2PA
Rated current Rated current
Applied
voltage
Rated
voltage
Single
screen
2-split
screen
Single
screen
2-split
screen
5 VDC±5% 5 VDC 80 mA --- 80 mA ---
12 VDC±5% 12 VDC 40 mA --- 40 mA ---
24 VDC±5% 24 VDC 20 mA 15 mA × 2 20 mA 13 mA × 2
Applied voltage Rated voltage Rated current
Green Red
12 VDC±5% 12 VDC 26 mA 20 mA
24 VDC±5% 24 VDC 13 mA 10 mA
Item Standard lamp Low-power lamp
Applied voltage Rated voltage Rated current
Model
Rated current
Model
5 VDC
6 V 200 mA SLL-06 100 mA
SLL-06H
12 VDC
14 V 80 mA SLL-14 40 mA
SLL-14H
24 VDC
28 V 40 mA SLL-28 25 mA
SLL-28H
Type
Applied voltage
Rated voltage Rated current
Model
DC only
5 VDC±5% 5 VDC 30 mA SLL-05E@
12 VDC±5% 12 VDC 15 mA SLL-12E@
24 VDC±5% 24 VDC 12.5 mA SLL-24E@
Operating frequency Mechanical 120 operations/minute max. *1
Electrical 30 operations/minute max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric
strength
Between terminals of same polarity
1,000 VAC, 50/60 Hz for 1 minute
*
2
Between terminals of different polarity
2,000 VAC, 50/60 Hz for 1 minute
Between current-carrying metal part and
ground
2,000 VAC, 50/60 Hz for 1 minute
Between each terminal and
non-current-carrying metal part
2,000 VAC, 50/60 Hz for 1 minute
Between lamp terminals
1,000 VAC, 50/60 Hz for 1 minute *3
Vibration resistance Malfunction
10 to 55 Hz, 1.5 mm double amplitude
Shock resistance Destruction 500 m/s2
Malfunction 200 m/s2
Life expectancy Mechanical
Momentary operation models:
1,000,000 operations min.
Alternate operation models:
200,000 operations min.
(One operation consists of set and
reset operations.)
Electrical 100,000 operations min.
Weight Approx. 30 g
Inrush current
NC
Silver contact: 10 A max.
NO
Silver contact: 10 A max.
Ambient operating temperature
LED-lighted models:
−
10
°
C to 40
°
C
(with no icing or condensation)
Incandescent lamp-lighted models:
−
10
°
C to 50
°
C
(with no icing or condensation)
Ambient operating humidity 35% to 85%RH
Ambient storage temperature −25°C to 65°C
Degree of protection IP40
Electric shock protection class Class II
PTI (proof tracking index) 175
Pollution degree 3 (IEC947-5-1)