Data sheet PROmax PRO MAX 180W 24V 7,5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com PROmax offers diverse solutions for demanding automation. Our high performance and durable PROmax switchmode power supply units are designed for especially demanding requirements. PROmax reliably copes with continuous overload of up to 20% or short-term peak loads of 300% occurring with high control cabinet temperatures. High boost capability and full power are also made possible in a wide temperature range. Our switch-mode power supply units can be used around the world and are also suitable for confined spaces thanks to their low width. Together with our uninterruptible DC USPs, the diode modules or CAP modules, you can create a power supply solution that is tailored to your requirements. General ordering data Type Order No. Version GTIN (EAN) Qty. PRO MAX 180W 24V 7,5A 1478120000 Power supply, switch-mode power supply unit, 24 V 4050118286045 1 pc(s). Creation date November 7, 2020 4:37:55 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 1 Data sheet PROmax PRO MAX 180W 24V 7,5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions and weights Width Height Depth Net weight 50 mm 130 mm 125 mm 950 g Width (inches) Height (inches) Depth (inches) 1.969 inch 5.118 inch 4.921 inch 5...95 %, no condensation -25 C -40 C -40 C...85 C Operating temperature, max. Storage temperature, max. Operating temperature 70 C 85 C -25 C...70 C Operating altitude AC input voltage range DC current consumption Frequency range AC Inrush current Recommended back-up fuse Surge protection Continous output current @ UNominal Nominal output current for Unom Output voltage Parallel connection option Rated output voltage Residual ripple, breaking spikes Temperatures Humidity at operating temperature Operating temperature, min. Storage temperature, min. Storage temperature Environmental Product Compliance REACH SVHC Lead 7439-92-1 Rated data UL Certificate No. (cURus) E255651 3000m, 3000-6000m derating, @ 6000m 75% Load Input AC current consumption Connection system DC input voltage range Input fuse (internal) Rated input voltage Standby power consumption, max. 1 A @ 230 V AC / 2 A @ 115 V AC Screw connection 80...370 V DC Yes 100...240 V AC (widerange input) 1W 85...277 V AC 1A @ 370 VDC / 2A @ 120 VDC 45...65 Hz max. 15 A 10 A, Char. B circuit breaker, 6...8 A, char. C circuit breaker Varistor Output Connection system Current capacity (pulse) @ UNominal Output power Output voltage Protection against inverse voltage Reserve capacity @ UNominal Screw connection 22,5 A (2ms) 180 W 22.5...29.5 V (adjustable via potentiometer) Yes 9 A (1 min), 11.25 A (4s) 9 A @ 45C, 5,6 A @ 70C 7,5 A @ 60 C 24 V yes, max. 5 24 V DC 1 % < 50 mVss @ UNenn, Full Load Creation date November 7, 2020 4:37:55 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 2 Data sheet PROmax PRO MAX 180W 24V 7,5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data General data AC failure bridging time @ Inom Degree of efficiency Earth leakage current, max. MTBF min. 20 ms 91.5% 3.5 mA >500.000h (25C, IEC 61709 (SN29500)) -25 C...70 C 1.8 W Operating temperature Power loss, idling Protection against reverse voltages from the load 30...35 V DC Series switching capability Yes Start-up Surge voltage category -40 C III Current limiting Derating Housing version Mounting position, installation notice Power factor (approx.) Power loss, nominal load Protection degree Short-circuit protection Status indication > 120% IN > 60C / 75% @ 70C Metal, corrosion resistant Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom for air circ. Can mount side by side with no space in between. > 0.95 @ 230 V AC 16.7 W IP20 Yes LED red/green and relay (21.6 V DC LED green, relay on/ 20.6 LED red, relay off) EMC / shock / vibration Noise emission in accordance with EN55032 Interference immunity test acc. to Vibration resistance IEC 60068-2-6 Class B Shock resistance IEC 60068-2-27 EN 55024, EN 55032, IEC61000-3-2,-3, IEC61000-4-2,-3,-4,-5,-6,-8,-11 2.3 g 30 g in all directions Insulation coordination Humidity at operating temperature Insulation voltage output / earth Pollution severity Surge voltage category 5...95 %, no condensation 0.5 kV 2 III Insulation voltage input / earth Insulation voltage, input/output Protection class 3.5 kV 4 kV I, with PE connection For use with electronic equipment Acc. to EN50178 / VDE0160 VDE0100-410 / acc. to DIN57100-410 Electrical safety (applied standards) Electrical machine equipment Protection against dangerous shock currents Safety extra-low voltage Acc. to EN60204 Acc. to VDE0106-101 SELV according to EN 60950, PELV according to EN 60204, IEC61204 Protective separation / protection against electrical shock Safety transformers for switch-mode power supplies According to EN 61558-2-16 Connection data (input) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, max. Wire connection cross section, flexible (input), max. 10 0.22 mm 0.18 mm 3 for L/N/PE 0.6 Nm 4 mm Conductor cross-section, AWG/kcmil , min. Conductor cross-section, rigid , max. Connection system Screwdriver blade Tightening torque, min. 26 6 mm Screw connection 0.8 x 4.0, PZ 1 0.5 Nm Creation date November 7, 2020 4:37:55 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 3 Data sheet PROmax PRO MAX 180W 24V 7,5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Connection data (output) Conductor cross-section, AWG/kcmil , max. Conductor cross-section, flexible , max. Conductor cross-section, rigid , max. Connection system Screwdriver blade Tightening torque, min. Conductor cross-section, AWG/kcmil , min. Conductor cross-section, flexible , min. Conductor cross-section, rigid , min. Number of terminals Tightening torque, max. Floating contact Institute (GERMLLOYD) Certificate No. (GERMLLOYD) Institute (cULus) Certificate no. (cULus) Institute (cULusEX) Certificate no. (cULusEX) Institute (cURus) Certificate No. (cURus) 12 4 mm 6 mm Screw connection 0.6 x 3.5 0.5 Nm 26 0.5 mm 0.5 mm 8 (++,---,11,13,14) 0.6 Nm Signalling Contact load (NO contact) Status indication max. 30 V DC / 1 A LED red/green and relay (21.6 V DC LED green, relay on/ 20.6 LED red, relay off) Yes Approvals TAA00000TT E258476 E470829 E255651 Classifications ETIM 6.0 eClass 9.0 eClass 10.0 EC002540 27-04-07-01 27-04-07-01 ETIM 7.0 eClass 9.1 EC002540 27-04-07-01 Creation date November 7, 2020 4:37:55 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 4 Data sheet PROmax PRO MAX 180W 24V 7,5A Technical data Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Approvals Approvals ROHS Conform Downloads Approval/Certificate/Document of Conformity Engineering Data Engineering Data User Documentation Declaration of Conformity EPLAN, WSCAD STEP Operating instructions Creation date November 7, 2020 4:37:55 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 5 Data sheet PROmax PRO MAX 180W 24V 7,5A Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Drawings Electric symbol Derating curve Derating curve Creation date November 7, 2020 4:37:55 PM CET Catalogue status 23.10.2020 / We reserve the right to make technical changes. 6