1
TRG10R SERIES
10W SWITCHING
ADAPTER
Features
* Universal Input: 90-264Vac
* Continuous Short Circuit Protection
* Interchangeable AC Plugs
* EMI Meets EN55022 Class “B” and CISPR/FCC Class B
* Meet CEC & ErP Level V
(Output cable length 1800mm)
* Over Voltage Protection
Ordering information
TRG10RXXX - XX X XX
Model No. DC Plug Type OVP DC Cable Length and Type
E: With OVP Option 01: 720mm
02: 1220mm
03: 1800mm
11: 720mm with Ferrite Core
12: 1220mm with Ferrite Core
13: 1800mm with Ferrite Core
* 18AWG / UL1185
MODEL OUTPUT
VOLTAGE
MAX.
LOAD
MIN.
LOAD
RIPPLE &
NOISE
VOLTAGE
ACCURACY
LINE
REGULATION
LOAD
REGULATION
(%) EFF.
(Typ.)
TRG10R050 5V 1600mA 0A 50mV ±2% ±1% ±4% 75%
TRG10R060 6V 1500mA 0A 1% ±2% ±1% ±3% 75%
TRG10R075 7.5V 1200mA 0A 1% ±2% ±1% ±3% 75%
TRG10R090 9V 1100mA 0A 1% ±2% ±1% ±2% 76%
TRG10R120 12V 850mA 0A 1% ±2% ±1% ±2% 76%
TRG10R136 13.6V 750mA 0A 1% ±2% ±1% ±2% 76%
TRG10R150 15V 700mA 0A 1% ±2% ±1% ±2% 77%
TRG10R180 18V 550mA 0A 1% ±2% ±1% ±2% 77%
TRG10R240 24V 400mA 0A 1% ±2% ±1% ±2% 77%
Specifications are subject to change without notice.
2
Specifications TRG10R Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Input Current ………………….……………..................................... 0.4A max.
Inrush Current ………………….……………................... 40A max. @240Vac
Conducted EMI ……………………………………………. CISPR/FCC Class
B
Leakage Current ……… …………………………………….…… 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10mS typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recover y)
Over Voltage Protection ………………................. TVS Component to Clamp NOTE:
Temperature Coefficient ……………………..............................… ±0.05%/ 1. Voltage setpoint at 60% full load
GENERAL SPECIFICATIONS: 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Isolation …………………………………………… Input to output = 4,242VDC Ripple & Noise measuring @20MHz BW.
Operating Temperature ............................. 0 ~ 60(see Derating Curve) 3. Line regulation is measured from 100Vac to 240Vac with full load.
Storage Temperature ………………………………..........……........ -20~85 4. Load regulation is measured from 60% to full load and from 60% to
Humidity …………………...….......……….... 93% RH max. Non condensing 20% load (60% +/- 40% load)
Cooling …………………………………………………….. Natural Convection 5. ”Various TR Series adapters are PSE certified. PSE certification
Switching Frequency ………………………………………….. 66KHz Typical alone is not sufficient for importation into Japan. A valid PSE mark
MTBF ……….… MIL-HDBK-217F, GB, 25/115VAC ……. 200K hrs min. must contain the name of the importer as shown in the example below.
Altitude …………………………………………………………………… 2000m If PSE mark is required, the name of the registered importer must be
Dimensions ………..…….. 2.858x1.823x1.402lnches (72.6x46.3x35.6mm) supplied to Cincon on order placement. Product labels will not contain
Weight ……………………………………………………… 130g(0.29 Pounds) PSE mark if importer name is not supplied. Consult factory or local
SAFETY AND EMC: representative for details”
Emission and lmmunity ……….… EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
Safety …………………………….…… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
Tolerance:Inches:X.XXX±0.02
All Dimensions are in inches(mm)
Millimeters:X.XX±0.5
DC Plug type: V+ ─●)─ V-
DC Plug:Right Angle(ψ5.5/ψ2.1)L12mm
18AWG / 1800mm
UNIT: inches(mm)
Typical at 25˚C, nominal line and 7 5 % load, unless otherwise Spec ified
0%
25%
50%
75%
100%
0 102030405060
Ambient Temperature(oC)
Rated Load(%)
20LFM(Natural Convection)