First Edition Oct 17, 2005 LCD Module Technical Specification Final Revision ****** Type No. F-51430NFU-FW-AEN Approved by (Quality Assurance Division) ) Checked by (ACI Engineering Division) ) Prepared by (ACI Engineering Division) Table of Contents 1. General Specifications .................................................................................................................................. 2 2. Electrical Specifications ............................................................................................................................... 3 3. Optical Specifications ................................................................................................................................... 8 4. I/O Terminal .................................................................................................................................................... 10 5. Test ................................................................................................................................................................... 12 6. Appearance Standards ................................................................................................................................ 13 7. Code System of Production Lot ............................................................................................................... 16 8. Type Number.................................................................................................................................................. 16 9. Applying Precautions .................................................................................................................................. 16 10. Precautions Relating Product Handling................................................................................................ 17 11. Warranty ........................................................................................................................................................ 18 Revision History Rev. Date Page F-51430NFU-FW-AEN (AE) No. 2005-0082 Comment OPTREX CORPORATION Page 1/18 1. General Specifications Operating Temp. : min. 0C ~max. 50C Storage Temp. : min. -20C ~max. 60C Dot Pixels : 640 (W) x 480 (H) dots Dot Size : 0.27 (W) x 0.27 (H) mm Dot Pitch : 0.30 (W) x 0.30 (H) mm Viewing Area : 198.0 (W) x 150.0 (H) mm Outline Dimensions : 260.0* (W) x 174.0 (H) x 8.3 max. (D) mm * Without CFL Cable Weight : 438.5g max. LCD Type : NTD-21140 ( F-STN / Black &White-mode / Transmissive ) Viewing Angle : 12:00 Data Transfer : 4-bit parallel data transfer x 2 Backlight : Cold Cathode Fluorescent Lamp (CFL) x 1 Drawings : Dimensional Outline RoHS regulation : UE-210259B To our best knowledge, this product satisfies material requirement of RoHS regulation. Our company is doing the best efforts to obtain the equivalent certificate from our suppliers. F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 2/18 2. Electrical Specifications 2.1. Absolute Maximum Ratings VSS=0V Parameter Symbol Conditions Min. Max. Units Supply Voltage VCC -V SS - -0.3 7.0 V VHH -V SS - -0.3 30.0 V VI - -0.3 VCC +0.3 V (Logic) Supply Voltage (LCD Drive) Input Voltage 2.2. DC Characteristics Ta=25C, VSS=0V Parameter Symbol Conditions Min. Typ. Max. Units Supply Voltage VCC -V SS - 4.5 - 5.5 V (Logic) Supply Voltage VHH -V SS Shown in 3.1 V (LCD Drive) High Level VIH VCC =4.5~5.5V 0.8xVCC - VCC V VOH IOH =-0.4mA VCC-0.4 - - V VIL VCC =4.5~5.5V 0 - 0.2xVCC V VOL IOH =0.4mA - - 0.4 V ICC VCC -V SS=5.0V - 0.7 1.0 mA IHH VHH -V SS=21.4V - 8.7 13.0 mA Input Voltage High Level output Voltage Low Level Input Voltage Low Level output Voltage Supply Current F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 3/18 2.3. AC Characteristics VCC =4.5~5.5V Parameter Symbol Min. Max. Units tWCK tWCKH tWCKL tDS tDH tWLPH tLD tSL tLS tLH tr, tf tSU tH tSD tWDL 71 - ns 23 - ns 23 - ns 10 - ns 20 - ns 23 - ns 0 - ns 25 - ns 25 - ns 25 - ns - 50 Note.1 ns 30 - ns 50 - ns 100 - ns 1.2 - s Shift Clock Period Shift Clock "H" Pulse Width Shift Clock "L" Pulse Width Data Setup Time Data Hold Time Latch Pulse "H" Pulse Width Shift Clock Rise to Latch Pulse Rise Time Shift Clock Fall to Latch Pulse Fall Time Latch Pulse Rise to Shift Clock Rise Time Latch Pulse Fall to Shift Clock Rise Time Input Signal Rise,Fall Time Data Setup Time Data Hold Time DISPOFF Removal Time DISPOFF Enable Pulse Width tSU tH FLM t WLPH LP t SL tLD t LS t LH t WCKL t WCKH CP tr tf tWCK DU0~DU3 DL0~DL3 t DS LAST DATA tWDL t DH TOP DATA t SD DISPOFF F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 4/18 2.4. Timing Chart T=0.0595ms typ. LP CP DU0 SEG SEG DU3 633~ 636 637~ 640 SEG SEG 1~ 4 5~ 8 DL0 SEG SEG SEG SEG DL3 1273~ 1276 1277~ 1280 641~ 644 645~ 648 SEG SEG #1 DATA 633~ 636 637~ 640 SEG SEG 1~ 4 5~ 8 SEG SEG SEG SEG #241 DATA 1273~ 1276 1277~ 1280 641~ 644 645~ 648 FLM LP (Reduction) 240 x T FLM (Reduction) M 2.5. Comparison of Display and Data SEG1 #1 DU3 SEG640 DU2 DU1 DU0 DU0 DL1 DL0 UPPER DATA DU0~ DU3 #240 #241 DU1 DL3 DL2 DL1 DL0 LOWER DATA DL0~ DL3 #480 SEG641 F-51430NFU-FW-AEN (AE) No. 2005-0082 SEG1280 OPTREX CORPORATION Page 5/18 2.6. Power Supply ON/OFF Sequence 2.6.1. ON Sequence 2.6.2. OFF Sequence LEVEL SIGNAL VCC VSS VCC 0 t VCC VSS SIGNAL 0 t VHH VSS VCC VHH 0 t VSS DISPOFF Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 6/18 2.7. Lighting Specifications Ta=25C Parameter Symbol Conditions Min. Typ. Max. Units Notes Lamp Voltage VL - - 340 - Vrms 1 Lamp Current IL - 5.5 6.0 6.5 mArms 2 VS - 855 - - Vrms 3 2 4 Starting Voltage Surface Luminance Average Life L IL=6.0mA - 110 - cd/m TAL IL=6.0mA - 10000 - hrs 5 Note 1 :The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for 3 minutes . Note 2 :The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after lighting for 3 minutes. Note 3 :The voltage at starting the electric discharge when the voltage is increased gradually from 0V. Note 4 :Surface Luminance is specified by the average of 9 luminance values measured at each point shown above after 20 minutes power on with the all ON pattern adjusted to maximum contrast and the dimming control of 100%. ( maximum brightness ) Note 5 : CFL Life is defined as time period that the actual luminance becomes 50% or lower of its initial value. The Average life time of CFL is defined as the time when half or more of the testing CFLs have become less bright than 50% of the initial brightness at continuous operation. Y=60 I N C VS VL V Y=580 P1 P2 P3 P4 P5 P6 P7 P8 P9 F L IL Y=320 X=60 X=240 X=420 Measurement Points CFL Testing Circuit Recommended Inverter : S-12565 ( Produced by ELEVAM ) CXA-M10A (DC 5.0V, Produced by TDK) CXA-M10L (DC 12.0V, Produced by TDK) F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 7/18 3. Optical Specifications 3.1. LCD Driving Voltage Parameter Symbol Recommended LCD Driving Voltage VHH -V SS Note 1 Conditions Min. Typ. Max. Units Ta= 0C - - 24.6 V Ta=25C 19.9 21.4 22.9 V Ta=50C 17.7 - - V Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. 3.2. Optical Characteristics Ta=25C, 1/240 Duty, 1/14 Bias, VOD =21.4V (Note 4), = 0C, =- Parameter Contrast Ratio Note 1 Symbol Conditions Min. Typ. Max. CR = 0C , =- - 10 - Viewing Angle Response Time Units Shown in 3.3 Rise Note 2 TON - - 180 270 ms Decay Note 3 TOFF - - 150 230 ms Note 1 :Contrast ratio is definded as follows. (CR = LON / LOFF) LON : Luminance of the ON segments LOFF: Luminance of the OFF segments Note 2 :The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 :The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 :Definition of Driving Voltage VOD Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage VOD is definded as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum. VO-P ( B-2 )xVO-P / B 1 / ( f Fx A ) F-51430NFU-FW-AEN (AE) No. 2005-0082 1 / fF OPTREX CORPORATION Page 8/18 3.3. Definition of Viewing Angle and Optimum Viewing Area *Point * shows the point where contrast ratio is measured. : = 0, = - *Driving condition : 1/240 Duty, 1/14 Bias, VOD =21.4V, fF =70Hz 90 45 135 180 10 20 30 40 50 90 ( = 0) 180 225 0 315 270 270 *Area shows typ. CR2 3.4. System Block Diagram Temperature Chamber Rotation Table ( , ) Photometer #1980A WB LCD Optical Fiber Computer Control Unit & Waveform Generator Halogen bulb F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 9/18 4. I/O Terminal 4.1. Pin Assignment CN1 No. Symbol Function 1 FLM First Line Marker 2 LP Data Latch Signal 3 CP Clock Signal for Shifting Data 4 DISPOFF 5 VCC Power Supply for Logic 6 VSS Power Supply (0V, GND) 7 VHH Power Supply for LCD Drive 8 DU0 Display Upper Data 9 DU1 Display Upper Data 10 DU2 Display Upper Data 11 DU3 Display Upper Data 12 DL0 Display Lower Data 13 DL1 Display Lower Data 14 DL2 Display Lower Data 15 DL3 Display Lower Data Display Control Signal H : Display on L : Display off CN2 No. Symbol Function 1 CFL OUT1 (HOT) 2 NC Non-connection 3 NC Non-connection 4 CFL OUT2 (GND) Power Supply for CFL (HOT) Power Supply for CFL (GND) 4.2. Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. \ VHH VHH (+Voltage) Tr R1 VR MODULE R2 VSS VSS (0V) VCC VCC (+Voltage) R1+R2+VR=10~ 20K F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 10/18 4.3. Block Diagram 4 DU0~DU3 CP DISPOFF LP Column Driver NT7701 x 4 or equivalent FLM 640 240 M Cir. Row Driver NT7701 x 3 or equivalent M LCDP 240 640 x 480 dots 640 Column Driver NT7701 x 4 or equivalent 4 DL0~DL3 VHH Bias Circuit To LSI VSS VCC CFL OUT1(HOT) To LSI Logic CFL Backlight CFL OUT2(GND) F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 11/18 5. Test No change on display and in operation under the following test condition. Conditions: No. Unless otherwise specified, tests will be conducted under the following condition. Temperature: 205C Humidity : 655%RH tests will be not conducted under functioning state. Parameter Conditions Notes 1 High Temperature Operating 50C2C, 96hrs (operation state) 2 Low Temperature Operating 0C2C, 96hrs (operation state) 1 3 High Temperature Storage 60C2C, 96hrs 2 4 Low Temperature Storage -20C2C, 96hrs 1,2 5 Damp Proof Test 40C2C,90~95%RH, 96hrs 1,2 6 Vibration Test Total fixed amplitude : 1.5mm 3 Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. Dropping method corner dropping F E G B D A corner : once Edge dropping C A 60cm B,C,D edge : once Face dropping E,F,G face : once Concrete Surface Note 1 :No dew condensation to be observed. Note 2 :The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after removed from the test chamber. Note 3 :Vibration test will be conducted to the product itself without putting it in a container. F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 12/18 6. Appearance Standards 6.1. Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45against perpendicular line. 45 6.2. Definition of applicable Zones A Zone Bezel Flame B Zone C Zone A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area F-51430NFU-FW-AEN (AE) No. 2005-0082 OPTREX CORPORATION Page 13/18 6.3. Standards No. 1 Parameter Black and Criteria (1) Round Shape White Spots, Foreign Substances Zone Acceptable Number Dimension (mm) A B C D 0.1 * * * 0.1 < D 0.2 3 5 * 0.2 < D 0.3 2 3 * 0.3 < D 0.35 0 1 * 0.35< D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone X (mm) Acceptable Number Y (mm) A B C - 0.03 W * * * 2.0 L 0.05 W 4 4 * 1.0 L 0.1 W 4 4 * - 0.1 < W X : Length Y : Width In the same way (1) * : Disregard Total defects shall not exceed 7. 2 Air Bubbles (between glass & polarizer) Zone Dimension (mm) Acceptable Number A B C D1, D20.3 * * * 0.3