https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page1/8
Router-PSI-MODEM-GSM/ETH-2313355
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Industrial GSM router with GPRS/EDGE for mounting on EN DIN rail. GSM and GPRS/EDGE. 850 + 900 + 1800
+ 1900 MHz. Ethernet interface. Firewall and VPN support. 6 alarm inputs and 4 switching outputs. 24 V DC
supply voltage.
Your advantages
Configuration via web-based management
Up to three VPN tunnels simultaneously
Can be used worldwide
Starting of VPN via call
High electromagnetic compatibility
Starting of VPN via SMS
Authentication with X.509 certificates
Firewall
Encryption of SIM card PINs
Autocrossing
10/100 Mbps automatic detection
IPsec and OpenVPN support
NAT table
6 digital switching inputs: for sending freely configurable text messages (SMS, FAX, e-mail) and starting user-defined functions
Four switching outputs: can be activated via SMS and Ethernet and for GSM and connection diagnostics
Key Commercial Data
Packing unit 1 pc
GTIN
GTIN 4046356438827
Weight per Piece (excluding packing) 286.100 g
Custom tariff number 85176200
https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page2/8
Router-PSI-MODEM-GSM/ETH-2313355
Country of origin Germany
Technical data
Note
Utilization restriction EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width 35 mm
Height 99 mm
Depth 114.5 mm
Ambient conditions
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 75 °C
Permissible humidity (operation) 30 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 30 % ... 95 % (non-condensing)
Altitude 5000 m (For restrictions see manufacturer's declaration)
Degree of protection IP20
Noise immunity EN 61000-6-2:2005
General
Electrical isolation VCC // GSM // Ethernet // PE
Test voltage data interface/data interface 500 V (50 Hz, 1 min.)
Test voltage data interface/power supply 500 V (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with R&TTE directive 1999/5/EC
Net weight 291 g
Housing material PA 6.6-FR
Color green
Conformance CE-compliant
UL, USA/Canada cULus listed UL 508
Power supply
Nominal supply voltage 24 V DC ±5 % (as an alternative or redundant, via backplane bus contact
and system current supply)
Supply voltage range 10 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Typical current consumption < 360 mA (24 V DC)
< 90 mA (stand by)
Serial interface
Interface 1 Ethernet interface, 10/100Base-T(X) in acc. with IEEE802.3u
Interface Ethernet
Connection method RJ45 socket, shielded
https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page3/8
Router-PSI-MODEM-GSM/ETH-2313355
Technical data
Serial interface
Transmission length 100 m (shielded twisted pair)
Protocols supported TCP/IP, UDP/IP, FTP, HTTP
Auxiliary protocols ARP, DHCP, PING (ICMP), SNMP V1, SMTP
Serial transmission speed 10/100 Mbps, auto negotiation
Wireless interface
Interface description GSM / GPRS / EDGE
Frequency 850 MHz (2 W (EGSM))
900 MHz (2 W (EGSM))
1800 MHz (1 W (EGSM))
1900 MHz (1 W (EGSM))
Data rate ≤ 210 kbps (EDGE)
Antenna 50 Ω impedance SMA antenna socket
SIM interface 1 1.8 volt, 3 volt
GPRS Class 12, Class B
CS1 ... CS4
EDGE Multislot Class 10
Network function
4 time slots for receiving data, 4 time slots for transmitting data. The PIN
is saved in the modem. After a voltage interruption, there is automatic
redialing into the network. Integrated TCP/IP stack, firewall and VPN
support, independent connection establishment.
Network check LED to show data signal quality
Function
Web-based management yes
Management Web-based management, SNMP
Digital outputs
Output name Digital output
Number of outputs 4
Voltage output signal 10 V DC ... 30 V DC (depending on the operating voltage)
Current output signal ≤ 50 mA (Short-circuit-proof)
Digital inputs
Description of the input Digital input
Number of inputs 6
Voltage input signal 10 V DC ... 30 V DC
Standards and Regulations
Electromagnetic compatibility Conformance with R&TTE directive 1999/5/EC
Type of test Free fall in acc. with IEC 60068-2-32
https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page4/8
Router-PSI-MODEM-GSM/ETH-2313355
Technical data
Standards and Regulations
Test result 1 m
Type of test Vibration resistance in acc. with EN60068-2-6/IEC60068-2-6
Test result 5g, 150 Hz, 1.5 h, in XYZ direction
Type of test Shock in acc. with EN60068-2-27/IEC60068-2-27
Test result Operation: 15g, 11 ms period, half-sine shock pulse
Type of test Shock in acc. with EN60068-2-27/IEC60068-2-27
Test result Storage: 30g, 11 ms period, half-sine shock pulse
Noise immunity EN 61000-6-2:2005
Standards/regulations EN 61000-4-2
Contact discharge ± 6 kV
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 3 GHz
Standards/regulations EN 61000-4-4
Comments Criterion A
Standards/regulations EN 61000-4-5
EN61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Conformance CE-compliant
UL, USA/Canada cULus listed UL 508
Noxious gas test ISA-S71.04-1985 G3 Harsh Group A
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page5/8
Router-PSI-MODEM-GSM/ETH-2313355
Connection diagram
I3I4I5I6
O1O2
24V0VI1I2
O3O4
-
+
Switching inputs
Dimensional drawing
120
35
99
PSI-MODEM-GSM/ETH
Ord.-No. 23 13 355
LAN
VCC
RD
TD
ALR
NET
DCD
SIM
AA
VPN
ACT
LNK
ANT
Schematic diagram
PSI-MODEM-GSM/ETH
Ord.-No. 23 13 355
LAN
VCC
RD
TD
ALR
NET
DCD
SIM
AA
VPN
ACT
LNK
ANT
3
12
4
5
Front view
Schematic diagram
O1 O2
24V 0V I1 I2
O3 O4
I3 I4 I5 I6
24 V
0 V
I3 I4 I5 I6
O1 O2
24V 0V I1 I2
O3 O4
Device connections
https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page6/8
Router-PSI-MODEM-GSM/ETH-2313355
Schematic diagram
A
LAN
NET
DCD
SIM
AA
VPN
ACT
LNK
C
LAN
NET
DCD
SIM
AA
VPN
ACT
LNK
B
Insert the SIM card
Classifications
eCl@ss
eCl@ss 4.0 27230207
eCl@ss 4.1 27230207
eCl@ss 5.0 27230207
eCl@ss 5.1 19030100
eCl@ss 6.0 19060500
eCl@ss 7.0 19060590
eCl@ss 8.0 19060590
eCl@ss 9.0 19060590
ETIM
ETIM 2.0 EC000310
ETIM 3.0 EC000310
ETIM 4.0 EC000740
ETIM 5.0 EC000740
ETIM 6.0 EC000740
UNSPSC
UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page7/8
Router-PSI-MODEM-GSM/ETH-2313355
Classifications
UNSPSC
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 43222628
Accessories
Accessories
Antenna
Antenna-PSI-GSM/UMTS-QB-ANT-2313371
GSM UMTS antenna, with omnidirectional characteristic, 2 m antenna cable with SMA round connector
Antenna-TC ANT MOBILE WALL 5M-2702273
Multiband mobile communication antenna with mounting bracket for outdoor installation, 5 m antenna cable with SMA
circular connector, suitable for LTE/4G
Coaxial cable
Antenna cable-PSI-CAB-GSM/UMTS- 5M-2900980
Mobile network antenna cable, 5m in length, SMA (male) -> SMA (female), 50ohm impedance
Antenna cable-PSI-CAB-GSM/UMTS-10M-2900981
Mobile network antenna cable, 10m in length, SMA (male) -> SMA (female), 50ohm impedance
https://www.phoenixcontact.com/us/products/2313355
10/19/2018Page8/8
Router-PSI-MODEM-GSM/ETH-2313355
Accessories
DIN rail connector
Electronic housing-ME 17,5 TBUS 1,5/ 5-ST-3,81 GN-2709561
DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.
Power supply
Power supply unit-MINI-SYS-PS-100-240AC/24DC/1.5-2866983
Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A
Surge protection for transceiver systems
Surge protection device-CSMA-LAMBDA/4-2.0-BS-SET-2800491
Attachment plug with Lambda/4 technology as surge protection for coaxial signal interfaces. Connection: Male/female
SMA connectors.
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com