cui.com
CUI Inc │ SERIES: VF-S320-XXA │ DESCRIPTION: AC-DC POWER SUPPLY date 04/23/2013 │ page 2 of 5
INPUT
parameter conditions/description min typ max units
voltage 90-132/180-264 auto selectable 90/180 132/264 Vac
frequency 47 63 Hz
current at 100~120 Vac, cold start
at 200~240 Vac, cold start
6
3
A
A
inrush current at 115 Vac, cold start
at 230 Vac, cold start
35
70
A
A
power factor Compliant to EN 61000-3-2 class A
OUTPUT
parameter conditions/description min typ max units
line regulation low line to high line ±1 %
load regulation all other outputs ±1 %
temperaturecoefcient 0.25 mV/°C
transient response Output voltage returns to within 1% in less than 2.5 ms for a 50% load change.
Peak transient does not exceed 5%.
start-up time At 120 Vac 1 s
rise time 0.2 20 ms
hold-up time At 120 Vac and 80% of rated maximim load 20 ms
adjustability ±5 %
power good
Designated as PG on the CN3.
This signal goes TTL high 100-500 ms after the output reaches regulation.
It goes low at least 1 mS before loss of regulation.
fan drive 12 Vdc / 400 mA for external fan
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection ACinputneedstoberesettorestartthepowersupply. 130 %
over current protection automaticallyrecovers 110 140
short circuit protection shortcircuitcanbecontinuous,recoversautomaticallyuponremovalofshort
over temperature protection autorecovery 85 °C
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
applied for 3 seconds at 10 mA max.
primarytosecondary
primarytotransformercore
primarytoearthchassis
3,000
1,500
1,500
Vac
Vac
Vac
safetyapprovals UL 60950-1, CSA C22.2 No. 60950-1-03, TUV EN 60950-1, CE Mark (LVD)
EN 61000-3-(2,3) & IEC 61000-4 Series regulations and CB
EMI/EMC pass FCC Part 15, CISPR 22 class B, conducted
leakage current at 240 Vac
at 120 Vac
500
300
μA
μA
RoHS compliant yes
MTBF according to MIL-HDBK-217 at 30 ºC 100,000 hrs