CSM_H7HP_DS_E_5_3
1
Total Counter/Time Counter (DIN 72 x 36)
H7HP
DIN 72 x 36-mm Total Counter/Time Counter with
Easy-to-read Displays and Water and Oil
Resistance Equivalent to IP66
Large, easy-to-read displays: 15-mm-high characters for 6-digit models;
12-mm-high characters for 8-digit models.
High-visibility, negative transmissive LCD display with built-in red LED
backlight at low power consumption.
IP66 with oil resistance and NEMA4 are achieved by unifying the front
with the casing case and using oil-resistant materials and parts.
Compact (66 mm) body.
Switch 6-digit models between total counter and time counter operation.
Just change a switch setting for either an NPN or PNP input.
Supports both external resetting and manual resetting.
Finger-protection terminal block cover prevents electrical shock and
conforms to VDE0106, Part 100.
Safety standards: UL, CSA, EMC (EN 61326), CE Marking.
Model Number Structure
Model Number Legend
1. Classification
A: Total counter/time counter
C: Total counter
2. Digits
None: 6 digits
8: 8 digits
3. Supply Voltage
None: 100 to 240 VAC
D: 12 to 24 VDC
4. Case Color
None: Light gray (Munsell 5Y7/1)
B: Black
Ordering Information
List of Models
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
1 2 3 4
H7HP-@@@@
Supply voltage 6-digit total counter/time counter 8-digit total counter
Light gray Black Light gray Black
100 to 240 VAC H7HP-A H7HP-AB H7HP-C8 H7HP-C8B
12 to 24 VDC H7HP-AD H7HP-ADB H7HP-C8D H7HP-C8DB
H7HP
2
Specifications
Ratings
Note: 1. Contains 20% ripple (p-p) max.
2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even
if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be
functional.
Item 6-digit total counter/time counter 8-digit total counter
H7HP-A H7HP-AD H7HP-C8 H7HP-C8D
Rated supply voltage 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1)
External power supply 50 mA at 12 VDC --- 50 mA at 12 VDC ---
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 100 to 240 VAC: 6.5 VA max.
12 to 24 VDC: 0.6 W max.
Dimensions 72 x 36 x 66 mm (W x H x D)
Mounting method Flush mounting
External connections Screw terminals
Degree of protection Panel surface: IP66 with oil resistance, NEMA 4 (indoors). Panel surface only: IEC IP66. IEC IP66
Display 7-segment, negative transmissive LCD (with red backlight)
Digits 6 digits (15-mm-high characters) 8 digits (12-mm-high characters)
Function Total counter/time counter (selected via DIP switch) Total counter
Input mode Up/down (individual) (total counter), or accumulative
(time counter)
Up/down (individual)
Max. counting speeds 30 Hz or 5 kHz (selected via DIP switch)
Counting range –99999 to 999999 –9999999 to 99999999
Time specification 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s
(selected via DIP switch)
---
Timing accuracy ±100 ppm (–10°C to 55°C) ---
Memory backup EEP-ROM (overwrites: 200,000 times min.) that can store data for 20 years min.
Input Input signals Count 1/start, count 2/gate, reset, and key protection (see note 2)
Input method No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch)
Count, start,
gate, reset
No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage: 2 VDC max.
Open (OFF) impedance: 100 kΩ min.
Voltage input (PNP transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
ON voltage: 9 to 24 VDC
OFF voltage: 5 VDC max.
Open (OFF) impedance: 100 kΩ min.
Key protection No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage: 0.5 VDC max.
Open (OFF) impedance: 100 kΩ min.
Input re-
sponse
speed
Reset Time counter: 20 ms; total counter: 20 ms or 1 ms (automatically switched according to counting speed)
Start Time counter: 20 ms
Key protection Approx. 1 s Approx. 1 s
Reset system External and manual resets
3
H7HP
Characteristics
Note: 1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2. UL508 and CAN/CSA-C22.2 No.14 certification conditions
Power supply 100 to 240VAC types
Ambient temperature 30°C Single mounting
Power supply 12 to 24VDC types
Ambient temperature 40°C Single mounting
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(AC model)
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(DC model)
2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model)
Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC
models)
Noise immunity ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals),
±480 V (between input terminals);
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Display: Malfunction: 8 kV
Destruction: 15 kV
DIP switch: Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions
Shock resistance Destruction: 294 m/s2 each in three directions
Malfunction: 196 m/s2 each in three directions
Ambient temperature Operating: –10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%
EMC (EMI) EN61326-1 (note 1.)
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61326-1 (note 1.)
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3);
2 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Approved standards UL508 (note 2), CSA C22.2 No.14 (note 2), conforms to EN61010-1, VDE0106/P100
Case color Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black)
Weight Approx. 115 g
H7HP
4
Connections
Terminal Arrangement
Note: 1. Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs.
2. Non-contact input is also available.
Operation
DIP Switch Settings
Switches 1 to 4 are all set to OFF before shipping.
H7HP-A@
H7HP-C@
Note: When the setting has been changed, turned power off and on
to continue. The display will show “0” when the power is turned
back on.
12 VDC0 V
5678910 11
1234
0 V
5678910 11
1234
12 VDC0 V
567891011
1234
0 V
567891011
1234
NPN mode
Unused Unused Unused
PNP mode
100 to 240 VAC
AC Models
H7HP-A
Unused Unused Unused
12 to 24 VDC
NPN mode
PNP mode
Unused Unused
Unused Unused Unused
NPN mode
PNP mode
100 to 240 VAC
Unused Unused Unused
12 to 24 VDC
NPN mode PNP mode
Unused Unused
H7HP-C8
H7HP-C8D
DC Models
H7HP-AD
External power supply
12 VDC 50 mA max.
Power
supply
Power
supply
Key
protection
input
Reset
input
Count 1
input or
start input
Count 2
input or
gate input
Power
supply
Key
protection
input
Reset
input
Count 1
input or
start input
Count 2
input or
gate input
External power supply
12 VDC 50 mA max.
Power
supply
Power
supply
Key
protection
input
Reset
input
Count 2
input
Power
supply
Key
protection
input
Reset
input
Count 1
input
Count 2
input
Count 1
input
Pin no. Item OFF ON
1 Function Total counter Time counter
2 Counting speed
(note)
30 Hz 5 kHz
Time range (note) 99999.9 h 99 h 59 min 59 s
3 Input mode (note) NPN PNP
4Unused --- ---
Pin no. Item OFF ON
1Unused --- ---
2 Counting speed
(note)
30 Hz 5 kHz
3 Input mode (note) NPN PNP
4Unused --- ---
5
H7HP
Operating Modes
Nomenclature
0
0.0 h
CP1
CP2
Total Counters
Time Counters
Reset input
Display
Display
display
Reset input
Gate input
Start input
999999
(see note)
99999
(see note)
99999.9h *
Note: Display values are shown for a 6-digit model.
The count value will return to "0" when "999999" is exceeded.
The display and output are turned OFF when the power
supply turns OFF, but the count value is stored internally.
Note: The count value will return to "0" when "99999.9" is exceeded.
The display and output are turned OFF when the power supply
turns OFF, but the count value is stored internally.
* Display values are shown for full scale set to 99999.9 h.
2
13
1. Reset Key
Resets the count value, but will not operate while the keys are protected.
2. Key Protection Indicator
Lit while the keys are protected (Reset Key is disabled.).
3. DIP Switch
Use to change a setting. Refer to DIP Switch Settings for details.
(The figure shows the DIP switch
label stuck to the rear of the case.)
H7HP
6
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Panel Cutouts
With Flush Mounting Bracket
Terminal cover (provided)
Panel
M3.5 terminal screw
H7HP-A
H7HP-C8
Panel cutouts are as shown below
(according to DIN43700).
Note: 1. The mounting panel thickness should
be 1 to 6 mm.
2. Water resistance will be lost if Counters
are mounted side-by-side.
Y92S-33 rubber
packing (provided)
Y92F-33 flush mounting
adaptor (provided)
7
H7HP
Connections (Common)
Input Connections
Note: The following is common for all H7GP/H7HP models.
No-voltage Input (NPN Input Mode)
Voltage Input (PNP Input Mode)
0 V
0 V
Reset, Count 1, Count 2, Start, and Gate Inputs
Reset, Count 1, Count 2, Start, and Gate Inputs Specification
Note: Two-wired sensors cannot be used.
Key Protection Input
Key Protection Inputs Specification
Note: Two-wired sensors cannot be used.
Sensor
Sensor
Reset input
Count 1 input
Count 2 input
Start input
Gate input
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage: 2 VDC max.
Current flow for 0-Ω short-circuit: Approx. 2 mA
Open (OFF) impedance: 100 kΩ min.
Key
protection
input
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage: 0.5 VDC max.
Current flow for 0-Ω short-circuit: Approx. 0.5 mA
Open (OFF) impedance: 100 kΩ min.
12 VDC
Reset input
Count 1 input
Count 2 input
Start input
Gate input
Sensor
H7GP/H7HP
Voltage Output
H7GP/H7HP
12 VDC
Key
protection
input
Sensor
Open Collector Output
Voltage Output Open Collector Output
12 VDC
(12 to 24 VDC)
12 VDC
0 V
0 V
12 VDC
Reset, Count 1, Count 2, Start, and Gate Inputs
Reset, Count 1, Count 2, Start, and Gate Inputs Specification
Note: Two-wired sensors cannot be used.
Sensor
Reset input
Count 1 input
Count 2 input
Start input
Gate input
Short-circuit (ON) impedance: 1 kΩ max.
ON voltage: 9 to 24 VDC
OFF voltage: 5 VDC max.
Open (OFF) impedance: 100 kΩ min.
Input impedance: Approx. 3.8 kΩ
12 VDC
0 V
H7HP
8
Safety Precautions (Common)
Refer to Safety Precautions for All Counters.
Note: The following is common for all H7GP/H7HP models.
Precautions for Safe Use
Observe the following items to ensure the safe use of this product.
Environmental Precautions
Store the H7GP/H7HP within the specified ratings. If the H7GP/
H7HP has been stored at temperatures 10°C or lower, let it stand
for 3 hours or longer at room temperature before turning ON the
power supply.
Use the H7GP/H7HP within the specified ratings for operating
temperature and humidity.
Do not operate the H7GP/H7HP in locations subject to sudden or
extreme changes in temperature, or locations where high humidity
may result in condensation.
Do not use the H7GP/H7HP in locations subject to vibrations or
shock. Extended use in such locations may result in damage due to
stress.
Do not use the H7GP/H7HP in locations subject to excessive dust,
corrosive gas, or direct sunlight.
Install the H7GP/H7HP well away from any sources of static
electricity, such as pipes transporting molding materials, powders,
or liquids.
The H7GP/H7HP is not waterproof or oil resistant.
Do not use it in locations subject to water or oil.
The life expectancy of internal components may be reduced if the
H7GP/H7HP is mounted side-by-side.
Do not use organic solvents (such as paint thinner or benzine),
strong alkaline, or strong acids because they will damage the
external finish.
Usage Precautions
Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly indicate its
function.
Be sure to wire the terminals correctly.
Do not install input lines in the same duct or conduit as power
supply or other high-voltage lines. Doing so may result in
malfunction due to noise. Separate the input lines from high-
voltage lines.
Internal elements may be destroyed if a voltage outside the rated
voltage is applied.
Maintain voltage fluctuations in the power supply within the
specified range.
Use a switch, relay, or other contact so that the rated power supply
voltage will be reached within 0.1 s. If the power supply voltage is
not reached quickly enough, the H7GP/H7HP may malfunction or
outputs may be unstable.
Although the H7GP/H7HP power supply (primary side) is isolated
from control circuits (secondary side) by a transformer, the primary
and secondary sides of the transformer are linked by a capacitor,
making it possible for high-frequency components to leak to the
secondary side. Take adequate precautions against electrical
shock. Do not connect input circuits to exposed parts (such as the
machine body) and be sure that the power supply is turned off
before wiring.
Flush Mounting
The panel surface is water-resistive (conforming to NEMA 4 and
IP66). In order to prevent the internal circuit from water penetration
through the space between the counter and operating panel, attach a
rubber packing between the counter and operating panel and secure
the rubber packing with the Y92F-3@ flush-mounting adaptor.
Be sure the rubber packing is installed in the correct direction. The
wider portion must be facing the panel when installed, as shown in
the following illustration. Using a flat-head screwdriver, press in the
Mounting Adapter until it cannot be pressed in any further in order to
ensure water-resistive performance.
Other
Oil resistance is not applicable to all types of oil. Be sure to test any
specific oils before actual application.
This may occasionally cause electric shock, fire, or malfunction.
Never disassemble, repair, or modify the H7GP/H7HP.
This may occasionally cause electric shock, fire, or malfunction.
Do not allow metal fragments or lead wire scraps to fall inside the
H7GP/H7HP.
Control
circuit
Display
circuit
Input
circuit
Adapter
Panel
Wider portion
facing panel
9
H7HP
Precaution for Correct Use
Power Supplies
When turning the power ON and OFF, input signal reception is
possible, unstable, or impossible as shown in the diagram below.
Apply the power supply voltage through a relay or switch in such a
way that the voltage reaches a fixed value immediately.
Self-diagnostic Function
The following displays will appear if an error occurs.
Labels
Unit labels are included with the H7GP/H7HP and DIP switch labels
are included with the H7HP. Attach these labels as shown in the
following illustrations.
Display Error Correction
---- Less than –99999
(H7HP, 6-digit model)
Less than –99999999
(H7HP, 8-digit model)
Press RST Key or reset
input
e1 CPU Press RST Key or turn
power OFF and then ON
e2 Memory
200 ms 5 ms
Input Impossible
Unstable
Possible ImpossibleUnstable
0 to 90 ms 0 to 2 s
ON
OFF
Power
supply
Unit Labels
H7GP
H7HP
DIP Switch Labels
H7HP
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.