www.clare.com
2
LCA710
R07
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Ratings Units
Blocking Voltage 60 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Absolute Maximum Ratings (@ 25˚C)
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current
AC/DC Configuration Continuous IL--1.0 A
DC Configuration 1.8
Peak Load Current 10ms ILPK - - 5.0 A
On-Resistance
AC/DC Configuration IL=1A RON -0.3 0.5 Ω
DC Configuration IL=1.8A 0.1 0.15
Off-State Leakage Current VL=60V ILEAK -- 1µA
Switching Speeds
Turn-On IF=10mA, VL=10V TON --2.5 ms
Turn-Off IF=10mA, VL=10V TOFF 0.25
Output Capacitance 0V; f=1MHz - - 105 - pF
Input Characteristics @ 25°C
Input Control Current IL=1A IF- - 10 mA
Input Dropout Current - IF0.4 0.7 - mA
Input Voltage Drop IF=10mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics @ 25°C
Input to Output Capacitance - CI/O -3 -pF
Electrical Characteristics