Switch Mode Power Supply Model PAM150 Medical Grade Certifications H.A.L.T. 150 Watts max output power Power Factor Correction TESTED Highly Accelerated Life Testing Single Output Electrical Specifications Input Voltage: 85-132/180-264 VAC, 47-63 Hz, 1 phase Input Current: <3.2A RMS @ 115 VAC @ full load <1.6A RMS @ 230 VAC @ full load Inrush Current: <25A, pk @ 132 VAC @ cold start <50A, pk @ 265 VAC @ cold start Power Factor: Meets Class A requirements Harmonic Distortion: Meets EN61000-3-2 for Class A EMI Filtering: Meets CISPR 11 and 22 and FCC Part 15 Class B (conducted) Input Protection: Internal AC line fuse; 250 VAC, 6.3A Surge Withstand: Meets EN61000-4-5 Level 3 Output Power: 150W with 15CFM air; 80W Convection Line Regulation: 0.3% Load Regulation: 0.5% PARD: <1% or 50mV; 20MHz bandwidth Thermal Shutdown Standard DC OK: Standard; Open Collector Turn-on Delay: <1 second after application of AC Input Stability: <0.1% for 8 hours after 1/2-hour warm up Isolation: >20 M @ 100 VDC between output terminals and chassis ground Hold-up Time: 20 ms @ full load (120 VAC) Output Polarity: Output is floating Minimum Load: 0% of rated load AC Power Fail: Transient Response: 3% for 25% load change @ 1A/s; 50% duty cycle 50/60 Hz TTLLOW logic "0" at least 2 ms before output drops 5%; Open Collector Overvoltage Protect: Output Rise Time: <100 ms (10% to 90%) Factory set, 125% 5%, cycle AC to reset Current Limit: 105-130% of rated current; Hiccup Reverse Voltage: Remote Sense: Compensates for up to 250mV of total cable drop Output has reverse voltage protection; Reverse current limited to 100% of output rating Remote On/Off: Optional Efficiency: Up to 85% Leakage Current: < 300 A MTBF: MIL-STD-HDBK 217E >200,000 hours @ 25C Highly Accelerated Life Testing Available Voltage Outputs* Voltage Codes Voltages (Volts) Continuous Current (Amps) -2 3.3 30 -3 -4 -5 -6 5.0 12.0 15.0 24.0 30 12.5 10.5 6.5 -7 28.0 5.5 -8 36.0 4.5 48.0 3.5 -9 * Consult factory for other voltages and OEM quantities. Note: Standard models are shown bold PART # STRUCTURE: MODEL VOLTAGE CODE OPTION CODES (See back) V1 PAM150 X ABC.... Example: Part Number PAM150-6-CK= 150W Power Factor Corrected, 24V @ 6.5A with a fan assembly and a Molex connector. CLICK HERE TO SEE THE PAM150 CODE TABLE AND AVAILABLE OPTIONS. Model PAM150 Options (code) 12V@0.5A Aux./Fan Drive (A) Fan Assembly (C) PF Invert (F) Single Wire Current Share 5% (I) Molex Connector (K) OR-ing Diode (O) Remote On/Off Invert (S) Droop Current Share 10% (B) DC OK Invert (E) Field-Configurable (G) Square Current Limit (J) Metric Mounting (M) Remote On/Off (R) Certifications NRTL* * * Recognition to UL60601-1 CSA C22.2 No. 601.1 BAUART Certification to EN60601-1 CB Test Report in Accordance with IEC60601-1 CE Declaration to Low Voltage Directive 2006/95/EC Compliance EN61000-4-5 Level 3 EN61000-4-2 Level 2 EN61000-3-2 for Class A EN61000-4-2 Level 3 (Air Only) EN61000-4-4 Level 3 EN61000-4-11 CISPR 11 and 22 FCC Part 15 Class B (conducted) Physical Specifications Dimensions: (HxWxL) 1.5" x 4.0" x 6" Operating Temp: 0 to 70C; rated power to 50C derate linearly to 50% at 70C. Relative Humidity: 5% to 90%, non-condensing Storage: -50 to 85C/20-90% RH Altitude: 6531 40,000' storage * * * Nationaly Recognized Test Laboratory (c) Copyright 2011 TAMURA CORPORATION OF AMERICA. Specifications subject to change without notice. TAMURA CORPORATION OF AMERICA 1040 South Andreasen Drive, STE. 100 Escondido, CA 92029-1951 (951) 699-1270 / Fax: (951) 676-9482 (800) 472-6624 www.tamuracorp.com FM 32227