Features 2:1 Wide Input Voltage Range 30 Watts Output Power 1.6kVDC Isolation Fixed Operating Frequency Six-Sided Continuous Shield International Safety Standard Approvals UL 1950 Component Recognized Standard 50.8 x40.6x10.2mm Package Efficiency to 90% Selection Guide 12V, 24V and 48V Input Types Input Range VDC Output Voltage VDC Output Current mA Input (4) Current mA Efficiency(5) % Capacitive(6) Load max. F RP30-121.5SE 9-18 1.5 6000 1014 78 85800 RP30-121.8SE 9-18 1.8 6000 1169 81 65000 RP30-122.5SE 9-18 2.5 6000 1582 83 33000 RP30-123.3SE 9-18 3.3 6000 2037 85 19500 RP30-1205SE 9-18 5 6000 3012 87 10200 RP30-1212SE 9-18 12 2500 2976 88 3240 RP30-1215SE 9-18 15 2000 2976 88 1100 RP30-241.5SE 18-36 1.5 6000 493 80 85800 RP30-241.8SE 18-36 1.8 6000 580 82 65000 RP30-242.5SE 18-36 2.5 6000 780 84 33000 RP30-243.3SE 18-36 3.3 6000 1010 86 19500 RP30-2405SE 18-36 5 6000 1490 88 10200 RP30-2412SE 18-36 12 2500 1470 89 3300 Part Number RP30-2415SE 18-36 15 2000 1470 89 1100 RP30-481.5SE 36-75 1.5 6000 244 81 85800 RP30-481.8SE 36-75 1.8 6000 290 83 65000 RP30-482.5SE 36-75 2.5 6000 390 85 33000 RP30-483.3SE 36-75 3.3 6000 500 87 19500 RP30-4805SE 36-75 5 6000 740 89 10200 RP30-4812SE 36-75 12 2500 730 90 3300 RP30-4815SE 36-75 15 2000 730 90 1100 RP30-1212DE 9-18 12 1250 3012 87 1020 RP30-1215DE 9-18 15 1000 3012 87 675 RP30-2412DE 18-36 12 1250 1488 88 1020 RP30-2415DE 18-36 15 1000 1488 88 675 RP30-4812DE 36-75 12 1250 744 88 1020 RP30-4815DE 36-75 15 1000 744 88 675 POWERLINE DC/DC-Converter RP30S_DE Series 30 Watt Single & Dual Output Description The E-Series of DC/DC Converters are fully certified to EN 60950: 2000. This makes them ideal for all Telecom and safety applications where approved isolation is required. They also meet UL 1950 and CSA 950 standards. 240 April-2005 www.recom-international.com POWERLINE RP30-S_DE Series DC/DC-Converter Derating-Graph (Ambient Temperature) RP30-4805SEW With Heat Sink RP30-4805SE 125 125 100 100 50 75 Natural Convection Output Power (%) Output Power (%) 75 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (C) Natural Convection 50 25 0 -40 -25 -10 0 80 90 100 50 60 70 Ambient Temperature Range (C) 62C 80 90 100 71C Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at info@recom-development.at 93 92 91 90 89 88 87 86 85 84 83 82 RP30-4805SE RP30-4805SE Efficiency VS Input Voltage Efficiency VS Output Load Efficiency (%) Efficiency (%) Typical Characteristics 36 40 45 50 55 60 65 70 75 92 90 89 88 87 86 85 84 80 78 76 74 1 2 3 4 5 6 Output Load (A) Intput Voltage (V) Specifications (typical at nominal input and 25C unless otherwise noted) Input Voltage Range Under Voltage Lockout 12V nominal input 24V nominal input 48V nominal input 12V input DC-DC ON DC-DC OFF 24V input DC-DC ON DC-DC OFF 48V input DC-DC ON DC-DC OFF Input Filter (see note 1) L-C Type Input Voltage Variation dv/dt (Complies with ETS300 132 part 4.4) Input Surge Voltage (100 ms max.) 12V Input 24V Input 48V Input Input Reflected Ripple (nominal Vin and full load) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (see note 7) Remote OFF input current 9-18VDC 18-36VDC 36-75VDC 9VDC 8VDC 17.8VDC 16VDC 36VDC 33VDC 5V/ms max 36VDC 50VDC 100VDC 30mAp-p DC-DC ON DC-DC OFF Nominal input 25ms typ. Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V 2.5mA continued on next page www.recom-international.com April-2005 241 RP30-S_DE Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25C unless otherwise noted) Output Power 30W max. Output Voltage Accuracy (full Load and nominal Vin) 1% Voltage Adjustability Minimum Load Line Regulation (LL-HL at full load) Load Regulation (25% to 100% FL) Cross Regulation (Note 9) Ripple and Noise (20MHz bandwith) (Measured with a 1004pF/50V MLCC) 10% Single & Dual Single Dual Single Dual Single 1.5, 1.8, 2.5, 3.3, 5V Single 12, 15V Dual 5, 12, 15V Temperature Coefficient 0.02%/C, max. Transient Response (25% load step change) Over Voltage Protection Zener diode clamp (only single) 0% 0.2% 0.5% 0.5% 1% 5% 50mVp-p 75mVp-p 100mVp-p 300S 1.5, 1.8, 2.5, 3.3V 5V 12V 15V Over Load Protection (% of full load at nominal Vin) 3.9V 6.2V 15V 18V 150% typ Short Circuit Protection Hiccup, automatic recovery Efficiency see Selection Guide" table Isolation Voltage 1.600VDC min. Isolation Resistance 109 min. Isolation Capacitance 1000pF max. Operating Frequency 300kHz typ. Approved to Safety Standards UL 1950, EN60950 Operating Temperature Range -40C to +85C(with derating) Maximum Case Temperature +100C Storage Temperature Range -55C to +105C Over Temperature Protection Thermal Impedance Natural convection Natural convection with Heat Sink Thermal Shock 115C typ. 10C/Watt 8.24C/Watt MIL-STD-810D Vibration 10-55Hz, 2G, 30 Min. along X, Y and Z Relative Humidity 5% to 95% RH Case Material Nickel-Coated copper Base Material Non-conductive black plastic Potting Material Conducted Emissions Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Epoxy (UL94-V0) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Class A Class A Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 continued on next page 242 April-2005 www.recom-international.com RP30-S_DE Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25C unless otherwise noted) Weight 48g Dimensions 50.8 x 40.6 x 10.2mm 1.535 x 106 Hours MTBF (see note 2) Notes : 1. An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current for 48V/24V models. RECOM suggest: Nippon chemi-con KMF series, 220F/100V, ESR 90m . 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40C (Ground fixed and controlled environment). 3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control pin voltage is referenced to negative input 8. Heat sink is optional and P/N: 7G-0011A. 9. See application notes for EMI-filtering. Package Style and Pinning (mm) 3rd angle projection 50.80 40.60 10.20 5.6 dia. 1.0 Pin Connections Pin # 1 2 4 5 6 7 8 45.70 5 Bottom View 15.20 Dual +Vin -Vin CTRL +Vout Com -Vout Trim Pin Pitch Tolerance 0.35 mm 17.80 5.10 Single +Vin -Vin CTRL No Pin +Vout -Vout Trim 1 10.20 12.70 6 External Output Trimming 2 7 4 10.20 17.80 Output can be externally trimmed by using the method shown below. ( ) for dual output trim 8 7(7) Trim Up 8(8) RD RU 8(8) www.recom-international.com April-2005 Trim Down 6(5) 243