http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TMR 2WI Series 2 Watt
Input Specifications
Input current at no load (nominal input) 24 Vin models: 20 mA typ.
48 Vin models: 15 mA typ.
Input current at full load (nominal input) 24 Vin models: 110 mA typ.
48 Vin models: 55 mA typ.
Surge voltage (100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Reverse voltage protection 0.5 A max.
Input Filter capacitor type
Start up time <1ms (at nominal input and resistive load)
Output Specifications
Voltage set accuracy ±2 %
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 25 – 100 % single output models: 0.75 % max.
dual output models: 2.0 % max. (balanced load)
Minimum load 25 % of rated max current (operation at lower
load condition is safe but a higher output ripple
will be experianced)
Temperature coefficient ±0.02 %/°C max.
Ripple and noise (20 MHz Bandwidth) 50 mVpk-pk max
Transient response (25 % load step change) 300 µs max.
Short circuit protection continuous (automatic recovery)
Capacitive load 3.3 VDC models: 2’200 µF max.
5 VDC models: 1’000 µF max.
12 VDC models: 170 µF max.
15VDC models: 110 µF max.
±5 VDC models: 470 µF max. (each output)
±12 VDC models: 100 µF max. (each output)
±15 VDC models: 47 µF max. (each output)
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case temperature +90°C max.
– Storage –55°C to +105°C
Derating (convection cooling) 2.9 %/K above 65°C
Humidity (non condensing) 95 % rel. H max.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >1 Mio h
Isolation voltage (60 sec.) – Input/Output 1’500 VDC
Isolation capacitance – Input/Output 500 pF max.
Isolation resistance – Input/Output (500 VDC) >1‘000 M Ohm
Switching frequency 100 to 650 kHz (PFM)
Remote On/Off control – On: <0.6 VDC or open circuit
– Off: 2.9 to 15 VDC
– Off stand by input current 1 mA typ / 3 mA max.
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU