Artikelnummer / part number : 82.556.170
Bezeichnung :
description : 0603 SMD VARISTOR SMD size: 0603
BASIC TEST
Characteristics
ENVIRONMENTAL RELIABILITY TEST
High Temperature Storage
Step Temperature Period
1 -40±3℃30Min±3
2Room
Temperature 1~2 hours
3 85±2℃30Min±3
4
Temperature 1~2 hours
Freigabe erteilt / Kunde / customer
general release:
Datum / date Unterschrift / signature
JP. PENLOU High Temperature Load 06-07-31
Würth Elektronik
JP. PENLOU New P/N 06-06-02
JP. PENLOU Operating temp. Range 05-11-30
JP. PENLOU Lead free soldering 05-11-04
Geprüft / checked 2006-06-02 Kontrolliert / approved JP. Penlou
Name Änderung / modification Datum / date
Kunde / customer :
http://www.we-online.com
E
Testbedingungen / test conditions :
Test Method/Description
Environmental condition under which every measuring is done without doubt on the measuring results.
Unless specially specified, temperature, relative humidity are 5 to 35℃, 45 to 85﹪RH.
Standard Test Condition
Maximum steady-state DC operating voltage the device can maintain and typical leakage current at 25℃
not exceed 50 µA.
Max. Clamping Voltage
The shift of TVS voltage after suffering the specified surge current.Surge Shift △V/V
Characteristic
Varistor Voltage
Typical leakage current at 25℃<50µALeakage Current
Surge Current
Device Capacitance measured with zero voltage bias 0.5VRMS and 1KHZ
Maximum peak voltage across the TVS measured at a specified pulse current(A)and waveform 8/20µs.
The temperature cycle of specified temperature shall be repeated five times and then stored at room
temperature and humidity for one or two hours. the change of varistor voltage shall be within 10 ﹪and
mechanical damage shall be examined.
Temperature Cycle
Maximum energy which may be dissipated with a specified waveform 10/1000µs.without device failure. Energy Absorption
Spezifikation für Freigabe / specification for release
Maximum peak current which may be applied with the specified waveform 8/20µs without device failure.
Max. Working Voltage
With the specified measuring current of 1mA DC applied.
Typical Capacitance
D-74638 Waldenburg · Max-Eyth-Straße 1 - 3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400
Test method and description
The specimen shall be subjected to 150 ± 2℃ for 1000 ± 12 hours in a thermostatic bath without load and
then stored at room temperature and humidity for 1 to 2 hours. The change of varistor voltage shall be
within 10 ﹪.
Low Temperature Storage
After being continuously applied the maximum allowable voltage at 85 ± 2℃ for 1000± 2 hours, the
specimen shall be stored at room temperature and humidity for one or two hours, the change of varistor
voltage shall be within 10﹪.
The specimen should be subjected to 40 ± 2℃, 90 to 95 ﹪RH environment , and the maximum allowable
voltage applied for 1000 hours, then stored at room temperature and humidity for one or two hours. the
change of varistor voltage shall be within 10﹪
The specimen should be subjected to 40 ± 2℃, without load for 1000 hours and then stored at room
temperature for one or two hours. the change of varistor voltage shall be within 10 ﹪
High Temperature Load
Damp Heat Load/Humidity Load
Würth Elektronik eiSos GmbH & Co.KG - Radialex department
Würth Elektronik eiSos GmbH & Co.KG - Radialex departmentWürth Elektronik eiSos GmbH & Co.KG - Radialex department
Würth Elektronik eiSos GmbH & Co.KG - Radialex department
PAGE/SEITE 5 - TO/VON 5