LC3-CP 10 (4710)
LC3-CP 11 (4711)
32
*a recess for optional unmating preventer LC3-CX 90
according to NEC 2008 NFPA 70
*b marking + on LC3-CP ...-1, - bei LC3-CP ...-2
*c nut enclosed separately
LC3-CP 10 LC3-CP 11
Photovoltaic chassis receptacle, with crimp contact, for front
mounting
LC3-CP 10: plug
LC3-CP 11: socket
1. Temperature range -40 °C/+85 °C
(+110 °C upper limit temperature)
2. Materials
Body/housing TPU, V0 according to UL 94
halogen-free, UV-resistant
Contact pin/bush CuZn, pre-nickeled and tinned
Contact protection (plugs only) PA 6.6, V0 according to UL 94
Sleeve (sockets only) CuZn, nickeled
Hexagonal nut PA 6.6 GF
3. Mechanical data
Insertion force160 N
Withdrawal force165 N
Mating with photovoltaic connectors LC3
Protection degree2IP 68
Connectable conductors crimp terminal
Section LC3-CP 10-... 2.5 2.5 mm
2(AWG 14)
Section LC3-CP 10-... 4.0 4.0 mm
2(AWG 12)
Section LC3-CP 10-... 6.0 6.0 mm
2(AWG 10)
4. Electrical data (at Tamb 20 °C)
Contact resistance 5.0 m
Rated current LC3-CP ... 2.5 22 A at Tamb 85 °C
Rated current LC3-CP ... 4.0 35 A at Tamb 85 °C
Rated current LC3-CP ... 6.0 40 A at Tamb 85 °C
Rated voltage31000 V DC
Overvoltage category3III (8 kV)
Material group3I (CTI 600)
Creepage distance 12.5 mm
Clearance 12.5 mm
Insulation resistance > 10 G
1measured with a proper counterpart
21 m/24 h, only in mated condition with a proper counterpart
IP X8 requirements under agreement between manufacturer and user
3according to DIN EN 60664/IEC 60664
®
under
preparation
®
Wiring solutions for photovoltaic power systems
LC3®-CP – Connector Parts without cable
33
LC3®
Composition of type designation
Series: LC3 or LC4
Type of product
CP Connector Part
Configuration
10 chassis plug
11 chassis socket
Polarity
-1 +
-2
Cable section
2.5 2.5 mm²
4.0 4.0 mm²
6.0 6.0 mm²
LC3-CP 10-1 4.0 chassis plug + 4.0
LC3-CP 10-1 6.0 chassis plug + 6.0
LC3-CP 11-2 4.0 chassis socket 4.0
LC3-CP 11-2 6.0 chassis socket 6.0
LC3-CP 10-1 4.0
Package unit: 100 pieces in a cardboard box
Designation Description Polarity Section
(mm2)
Typical examples
Features and benefits
chassis receptacles for sys-
tem components such as
inverters,
generator isola-
tion housings or
accumu-
lation boxes
quick and easy assembly
manual tool and crimping
machine allow for cost-
effective assembly of small
and high volumes
rugged and durable for
permanently reliable sys-
tem operation
optional locking according
to NEC 2008 NFPA 70
with contact-voltage pro-
tection
highest protection degree
IP 68
UV and ozone-resistant
halogen-free
protective caps available
for transport or spare
receptacles