SPECIFICATION
MODEL
DC VOLTAGE
CURRENT 25CFM
25CFM
Convection
Convection
RATED
POWER
OUTPUT
LINE REGULATION
VOLTAGE ADJ. RANGE
(MAIN OUTPUT)
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
INPUT
FUNCTION
INRUSH CURRENT (Typ.)
WORKING HUMIDITY
WORKING TEMP.
5V STANDBY
FAN SUPPLY
PS-ON INPUT SIGNAL
POWER GOOD / POWER FAIL
OVER TEMPERATURE
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load
16ms/230VAC 12ms/115VAC at full load
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
PF>0.94/230VAC PF>0.98/115VAC at full load
92%
91.5%
16.5 ~ 19.5V
93.5% 93%
29.7 ~ 35.1V 39.6 ~ 46.8V
4.2A/115VAC 2.1A/230VAC
COLD START 40A/115VAC 80A/230VAC
105 ~ 135% rated output power
13.2 ~ 15.6V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-30 ~ +70 (Refer to "Derating Curve")℃
5VSB : 5V@0.6A without fan, 1A with fan 25CFM ; tolerance 2%, ripple : 120mVp-p(max.)±
12V@0.5A for driving a fan ; tolerance 10%±
Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"
500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal
goes low at least 1ms before Vo below 90% of rated value
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
194.1Khrs min. MIL-HDBK-217F (25 )℃
127*76.2*35mm (L*W*H)
0.39Kg; 36pcs/15Kg/1.03CUFT
±1.0%
±0.5%
±1.0%
±0.5% ±0.5%
±1.0% ±1.0%
±0.5%
±3.0% ±3.0% ±1.0% ±1.0%
120mVp-p
11.4~12.6V 14.3~15.8V 25.6 ~ 28.4V 34.2 ~37.8V
150mVp-p 200mVp-p 250mVp-p
15V 27V 36V
33.3A
20.8A
26.7A
16.7A
14.9A
9.3A
11.2A
7A
399.6W
249.6W 250.5W
400.5W
251.1W
402.3W
252W
403.2W
EPP-400-12
SAFETY STANDARDS
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
12V
EMC IMMUNITY
EMC EMISSION
LEAKAGE CURRENT
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Protection type : Shut down o/p voltage, re-power on to recover
94%
52.8 ~ 62.4V
±0.5%
±1.0%
±1.0%
45.6 ~50.4V
250mVp-p
48V
8.4A
5.3A
254.4W
403.2W
93%
26.4 ~ 31.2V
±0.5%
±1.0%
±2.0%
22.8~25.2V
200mVp-p
24V
16.7A
10.5A
252W
400.8W
±0.5%
±1.0%
±3.0%
17.1~18.9V
180mVp-p
18V
22.3A
13.9A
250.5W
401.4W
93%
19.8 ~ 23.4V
EPP-400-15 EPP-400-24 EPP-400-27 EPP-400-36 EPP-400-48
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3,CCC GB17625.1, GB/T9254, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020
UL62368-1, TUV EN62368-1,EN60335-1, IEC62368-1, .1, EAC TP TC 004 approvedCCC GB4943
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
<0.75mA / 240VAC
EPP-400 series
400W Single Output with PFC Function
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Touch current was measured from primary input to DC output.
6. with FGThe power supply is considered a component which will be installed into a final equipment. All the ( ) EMC test are beenClassⅠ
executed by mounting the unit on a mm* mm metal plate with 1mm of thickness. ( ) 360 360 The without FG EMC test is beenⅡClass
executed by mounting the unit on a 130mm 86.6mm metal plate with 1mm of thickness * . final equipment must be re-confirmed that it still
meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher ℃℃
than 2000m(6500ft).
OPERATING ALTITUDE
Note.7
5000 meters
File Name:EPP-400-SPEC 2019-10-21
EPP-400-18