1
12-2017, Rev. 1217
www.te.com
© 2017 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
Micro Relay A/VFMA
Automotive Relays
Plug-in Micro ISO Relays
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC or 27VDC for 24VDC load voltages.
2) For a load current duration of maximum 3s for a make/break ratio of 1:10.
3) Current and time are compatible with circuit protection by a typical automotive fuse.
Relay will make, carry and break the specified current.
4) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
5) Electrical endurance data is not valid for diode versions. Any diode or pn-junction
parallel to the coil (internal or external) will significantly decrease the electrical lifetime,
especially when used for inductive loads.
6) Not applicable for polarity reverse loads like power windows
■ High current version with limiting continuous current 30A at 85°C
■ Pin assignment according to ISO 7588 part 3
■ Customized versions on request
– 24VDC versions with special contact gap
– Integrated components (e.g. diode)
– Customized marking
– Special covers (e.g. notches, release features)
– For latching version refer to Micro Relay Latching
– For low noise version refer to Micro Relay Low Noise
– For high current version refer to part number table
Typical applications
Cross carline up to 30A for example: ABS control, blower fans, cooling fan,
door control, door lock, fuel pump, heated front screen, immobilizer, interior
lights, seat control, seatbelt pretensioner, sun roof, trunk lock, valves,
window lifter, wiper control.
Max. DC load breaking capacity
Load limit curve 1: arc extinguishes during transit time (CO contact).
Load limit curve 2: safe shutdown, no stationary arc (NO contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
Contact Data Form A Standard Form C Form A HC Form C HC
Contact arrangement 1 form A, 1 form A, 1 form C, 1 form C, 1 form A, 1 form C
1 NO 1 NO 1 CO 1 CO 1 NO 1 CO
Rated voltage 12VDC 24VDC 12VDC 24VDC6) 12VDC 12VDC
Limiting continuous current, form A/form B NO/NC NO/NC
23°C 30A 30A 30/20A 30/20A 35A 35/25A
85°C 25A 25A 25/15A 25/15A 30A 30/20A
125°C 10A 10A 10/8A 10/8A 15A 15/10A
Limiting making current1)2), A/B (NO/NC) 120A 120A 120/40A 120/20A 120A 120/40A
Limiting breaking current 30A 20A 30/15A 20/10A 30A 30/20A
Limiting short-time current,
overload current, ISO 8820-33) 1.35 x 25A, 1800s 1.35 x 25A, 1800s 1.35 x 30A, 1800s
2.00 x 25A, 5s 2.00 x 25A, 5s 2.00 x 30A, 5s
3.50 x 25A, 0.5s 3.50 x 25A, 0.5s 3.50 x 30A, 0.5s
6.00 x 25A, 0.1s 6.00 x 25A, 0.1s 6.00 x 30A, 0.1s
Jump start test 24VDC for 5min conducting nominal current at 23°C
Contact material silver based
Min. recommended contact load4) 1A at 5VDC
Initial voltage drop
NO contact at 10A, typ./max. 15/200mV
NC contact at 10A, typ./max. 20/250mV
Frequency of operation 6 ops./min (0.1Hz)
Electrical endurance5)
resistive load at 14VDC >1x105 ops. >1x105 ops. >1x105 ops.
25A 25A (NO) 30A
resistive load at 28VDC >1x105 ops. >1x105 ops.
15A 15A (NO)
>1x105 ops.
10A (NC)
Mechanical endurance typ. 107 ops.
F074_fcw1_bw
FVFMA_fcw1c