5145 Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 or C18 with Filter, Circuit Breaker TA45 Protection class I with shield C14 C18 70 C 70 C Protection class II without shield Approvals and Compliances Description - Panel Mount : Screw-on mounting from front side - 3 Functions : Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole , Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - All single elements are already wired Unwired versions available on request Circuit Breaker non-illuminated or illuminated Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 References Alternative: version without line filter 6145 We recommend for new applications the new type DF12 Unique Selling Proposition - Characteristics Compact power entry module with circuit breaker High configurability Easy assembly with prewired modules Protection class I or II Weblinks pdf datasheet, html-datasheet, General Product Information, DistributorStock-Check, Accessories, Detailed request for product, Microsite Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 15 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 C to 55 C 10/055/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 appliance inlet/-outlet Circuit Breakers Line Filter MTBF C14 or C18 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 C, 10 A, Protection Class I or II Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 100'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: 5145 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40035745 UL Approvals UL UL File Number: E72928 EMC Products 1 5145 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products 5145 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimension [mm] Detail A 2 0 36 29 +0.2 1 43 6.3x0.8mm o6 3.25 A 0 80 0.1 72 +0.1 0 80 91.5 R 3-0.5 6.3x0.8mm 50.7 M3/o 3.6 13.5 67.5* * --- Version TA45 with undervoltage release Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [M] 1 Standard Version 2 x 11 47 2.2 - 2 Standard Version 2x4 47 2.2 - 3 Standard Version 2 x 2.5 47 2.2 - 4 Standard Version 2 x 1.6 47 2.2 - 6 Standard Version 2 x 0.7 47 2.2 - 8 Standard Version 2 x 0.6 47 2.2 - 10 Standard Version 2 x 0.4 47 2.2 - 15 Standard Version 2 x 0.1 47 2.2 - 1 Medical Version (M5) 2 x 11 47 - 1 2 Medical Version (M5) 2x4 47 - 1 6 Medical Version (M5) 2 x 0.7 47 - 1 8 Medical Version (M5) 2 x 0.6 47 - 1 10 Medical Version (M5) 2 x 0.4 47 - 1 15 Medical Version (M5) 2 x 0.1 47 - 1 EMC Products 3 5145 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Diagrams Medical version (M5) L' L P1 PE Cy Cx L2 Cy N TA 45 L1 1) PE' N' L' L 2) L1 1) PE P2 Cx PE' R L2 N' N 1) Line 2) Load P1 TA 45 Standard version 2) P2 1) Line 2) Load Medical filter (M5) protection class II L' L P1 Cx TA 45 L1 1) R L2 N' N 2) P2 1) Line 2) Load Attenuation Loss - - - - 50 differential mode _____ 50 common mode Standard version 1A 2A 3A 4A 6A 8A 10 A 15A 4 EMC Products 5145 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Medical version (M5) 1A 2A 3A 4A 6A 8A 10 A 15A EMC Products 5 5145 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Table 1 Selection for type TA45 Order example ABT W * Circuit Breaker of Equipment * 2-pole, rocker actuated * Quick connect terminal Other types on request Diagram Thermal overload protection Without illumination With illumination 1-pole 2-pole P2 P2 P1 4 3 P1 3 6 220...240 V 110...120 V ABT ABD A12 A14 A32 A34 } Colours Switch front W B 6 Rocker black black black white black - - - orange transp. Rocker legend K printed / bedruckt L printed / bedruckt l printed / bedruckt white / weiss Position of the rocker legend e.g F Illustration M printed black P printed I O white printed I O black R Rated current circuit breaker of equipment In Code In Code In Code In Code 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 J01 J02 J03 J04 J05 J06 J07 J08 J09 J10 J11 J12 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,5 J13 J14 J15 J16 J17 J18 J19 J20 J21 J22 J23 J25 2,8 3,0 3,5 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 9,0 J28 030 035 040 045 050 060 065 070 075 080 090 10,0 11,0 12,0 13,0 14,0 15,0 20,0 100 110 120 130 140 150 200 Without release: code C0 Undervoltage release P2 P1 U< 6 P2 Remote trip release b U< P1 Colour of print l white / weiss embossed / Relief H Surface O l O black / schwarz F ON ON Colour of print OFF OFF Illustration O Surface P2 ba P1 P2 c P1 U< U E Z A Code Rated voltage Un * * * * 2 240 V AC * * * * 3 230 V AC * * * * 4 120 V AC EMC Products F 150 C0 5145 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A Tripping characteristics In >_ 3... <_ 15 A [ min ] [ sec ] 10'000 [ min ] [ sec ] 10'000 Type TA45 Rated current In < 3 A 60 2000 30 20 1000 10 Ambient temp. Type TA45 Rated current 1-pole protected 60 2-pole protected 30 2'000 20 +23 C 2-pole protected 1'000 10 500 I n > 3... < 15 A 1-pole protected +23 C Ambient temp. 500 5 5 200 200 100 100 1 1 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 Tripping time Tripping time 50 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10 [ x In ] Multiple of rated current 0,3 0,2 0,1 1,05 1,32 2 Multiple of rated current Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [C] Correction factor -10 0,89 - 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 Configuration code (example) Type Order code TA45 (2-pole rocker-switch without accessories) 5145 - ABTWF150C0 - 000 - 111 - 10 - 00 see table 1 3 4 5 8 10 [ x In ] * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. 1) Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at + 40 C ambient temperature 6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A Optional Variants 00 standard 21 V-Lock notch Terminal PE 0 without (PCII) 1 QC 6.3x0.8 Terminal L and N 1 QC 6.3x0.8, without connection to TA45 3 Connection to TA45 non insulated Metal Shield Filter 0 with metal shield (PCI) 1 without metal shield (PCI and PCII) Type of mains filter / capacitor / bleed resistor 1 standard X2,Y2 without 3 medical M5 X2 with 1) Not in conjunction with PC II 2) The rated current of the line-filter must be equal or more than the rated current of TA45. Rated current 1 1A 2 2A 3 3A 4 4A 5 6A 6 8A 7 10A 8 15A 1) 2) EMC Products 7 5145 Packaging unit Power Entry Modules with Line Filter https://www.schurter.com /PG06 20 Pcs Accessories Description Assorted Covers Rear Cover 0859.0074 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to 5145 Connector Overview complete 4782 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4022 Mounting: Power Supply Cord, 3 x 1.5 mm, Screw clamps, Connector: IEC C13 4022 4785 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm, Screw clamps, Connector: IEC C13 4012 Connector further types to 5145 ... Mating Outlets/Connectors shuttered Power Cord Overview complete Power cord with IEC connector C17, V-Lock, straight VAC17KS 02.12.2017 Power Cord further types to 5145 8 EMC Products The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schurter: 5-ABTWF150C0-811 5-ABTWF150C0-831 5-ABTWF050C0-531 5-ABTWF050C0-511 5-ABDWF150C0-811 5ABDWF150C0-831 5-ABDWF050C0-511 5-ABDWF050C0-531 5-ABDWF100C0-711 5145.ABDWF100C0.811 5145.0646.631