• North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and prod uct information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
1
Double-Balanced Mixer
Rev. V3
M6E-50
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
Features
• LO 5 TO 500 MHz
• RF 5 TO 500 MHz
• IF DC TO 500 MHz
• LO DRIVE +7 dBm (nominal)
• HIGH ISOLATION 40 dB (TYP.)
Description
The M6E-50 is a double balanced mixer, designed for use in
military, commercial and test equipment applications. The design
utilizes Schottky ring quad diodes and broadband ferrite baluns to
attain excellent performance. This mixer can also be used as a
phase detector and/or bi-phase modul ator since the IF port is DC
coupled to the diodes. Environmental screening available to
MIL-STD-883, MIL-STD-202, or MIL-DTL-28837, consult factory.
Ordering Information
Part Number Package
M6E-50 Relay Header
Electrical Specifications: Z0 = 50Ω Lo = +7 dBm (Downconverter application only)
Parameter Test Conditions Units Typical Guaranteed
+25ºC -54º to +85ºC
SSB Conversion Loss
(max) & SSB Noise
Figure (max)
fR = 10 to 100 MHz , fL = 10 to 100 MHz, fI = 10 to 100 MHz
fR = 100 to 200 MHz , fL = 100 to 200 MHz, fI = 10 to 200 MHz
fR = 5 to 500 MHz, fL = 5 to 500 MHz, fI = 0.5 to 500 MHz
dB
dB
dB
6.5
7.5
8.5
7.0
8.0
9.0
7.5
8.5
9.0
Isolation, L to R (min) fL = 5 to 50 MHz
fL = 50 to 500 MHz dB
dB 50
35 40
30 38
28
Isolation, L to I (min) fL = 5 to 50 MHz
fL = 50 to 500 MHz dB
dB 45
30 35
25 33
23
1 dB Conversion Comp.
Input IP3